0% found this document useful (0 votes)
108 views2 pages

AG Series Brackish Water RO Elements

RO MEMBRANE

Uploaded by

dodi eko nanda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views2 pages

AG Series Brackish Water RO Elements

RO MEMBRANE

Uploaded by

dodi eko nanda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AG Series

FACT SHEET

Standard Brackish Water Reverse Osmosis Elements


The AG-Series standard brackish water reverse Table 2: Element Properties (4)
osmosis elements are characterized by high flux and
Model Membrane Outer Part
high sodium chloride rejection. AG Series elements Area Wrap Number
are selected when high rejection and operating ft2 (m2)
pressures as low as 200 psi (1,379 kPa) are desired.
AG2540TM 27 (2.5) Tape 1206729
These elements are considered a standard in the
industry. AG4025T 60 (5.6) Tape 1206754
AG4026T 60 (5.6) Tape 1206756
Table 1: Element Specification AG4040FM 85 (7.9) Fiberglass 3032513

Membrane AG Series, thin-film membrane (TFM) AG4040TM 85 (7.9) Tape 3032514


AG8040F 365 (33.9) Fiberglass 3032515
Model Average Average Minimum AG8040F-400 400 (37.2) Fiberglass 3032518
Permeate NaCl NaCl
Flow Rejection Rejection AG8040F-440 440 (40.9) Fiberglass 3194307
gpd (m3/day) (2)(3) (2)(3)
(1)(3)

AG2540TM 750 (2.8) 99.65% 99.4%


AG4025T 1,600 (6.1) 99.65% 99.4%
AG4026T 1,600 (6.1) 99.65% 99.4%
AG4040FM 2,400 (9.1) 99.65% 99.4%
AG4040TM 2,400 (9.1) 99.65% 99.4%
AG8040F 10,000 (37.9) 99.65% 99.4% Figure 1: Element Dimensions Diagram – Female
AG8040F-400 11,000 (41.6) 99.65% 99.4%
AG8040F-440 12,000 (45.4) 99.65% 99.4%

(1) Individualflow rate may vary ±20%.


(2) Stabilizedsalt rejection after 24 hours of operation.
(3) Testing conditions: 2,000 ppm NaCl solution at 225 psi (1,551
kPa) operating pressure, 77°F (25°C), pH 7.5 and 15% recovery.

Figure 2: Element Dimensions Diagram – Male

WATER TECHNOLOGIES
AG Series

(4)
Table 3: Dimensions and Weight Table 4: Operating and CIP Parameters (4)

Dimensions, inches (cm) Boxed Typical 200 psi (1,379 kPa)


Operating
Model Type Weight Pressure
A B C lbs.
(kg) Typical 10-20GFD (15-35 LMH)
Operating Flux
40.0 0.75 2.4 7
AG2540TM Male
(101.6) (1.90) (6.1) (3) Maximum Tape: 450 psi (3,103 kPa)
Operating Other outerwrap: 600 psi (4,137 kPa)
25.0 0.625 3.9 7
AG4025T Female Pressure
(1.59) (9.9) (3)
(63.5)
26.0 0.625 3.9 9 Maximum Continuous operation: 122°F (50°C)
AG4026T Female Temperature Clean-In-Place (CIP): 122°F (50°C)
(66.7) (1.59) (9.9) (4)

40.0 0.75 3.9 11 pH Range Optimum rejection: 7.0-7.5,


AG4040FM Male Continuous operation: 2.0-11.0,
(101.6) (1.90) (9.9) (5)
Clean-In-Place (CIP): 1.0-13.0 (5)
40.0 0.75 3.9 11
AG4040TM Male Maximum Tape: 7 psi (48 kPa) over an element,
(101.6) (1.90) (9.9) (5)
Pressure Drop 25 psi (172 kPa) over the vessel
40.0 1.125 7.9 35 Cage and FRP: 15 psi (103 kPa) over the
AG8040F Female
(101.6) (2.86) (20.1) (16) element, 60 psi (413 kPa) over the vessel
40.0 1.125 7.9 35 Chlorine 1,000+ ppm x hours,
AG8040F-400 Female
(101.6) (2.86) (20.1) (16) Tolerance dechlorination recommended
40.0 1.125 7.9 35 Feedwater NTU < 1
AG8040F-440 Female
(101.6) (2.86) (20.1) (16) SDI15 < 5

*Trademark of Veolia; may be registered in one or more countries. ©2023 Veolia. All rights reserved. FS1262EN.docx Sep-23
(4) Element properties and parameters are indicative numbers.
Specific values by element may vary within normal element
manufacturing tolerances.
(5) Refer to Cleaning Guidelines Technical Bulletin TB1194

Veolia Water Technologies


Please contact us via:
www.veoliawatertechnologies.com 2

You might also like