TL Jones M150 & SP150
Elevator Entrance Light Curtains
High performance and ++ High impact vandal resistant
materials
competively priced, the
M150 and SP150 elevator ++ Tested to CE requirements
entrance light curtains ++ Tested to exceed requirements
of EN81-70 and GB7588-2003
are suitable for both side-
opening or centre opening ++ Two power supply options: 10-
30V DC or 10-40V DC
doors
++ Optically isolated solid state
relay output. Two versions
++ Suitable for dynamic or static
available: N/O or N/C contacts
installations
++ IP65/NEMA 4 water and dust
resistant
++ No on-site adjustment required Key Features
++ No special cables required ++ Suitable for dynamic and static
++ Immune to interference from installations
reflection or sunlight
++ 154 criss-cross beams
++ SMT electronics with proven
technology and reliability ++ Easy installation without need to
expose componentry
++ Easy installation without need to
expose componentry ++ No on-site adjustment required
Fig. 1 Centre Opening
Fig. 2 Side opening
Fig. 3 Side opening, showing combination of M and SP units
Technical Specification
Size M150 12mm (deep) x 1978mm (high) x 25mm (wide)
SP150 12mm (deep) x 1978mm (high) x 25mm (wide)
Number of diodes/beams 32/154 (5 way scanning)
Distance between diodes Distance between diodes is 58mm
Highest beam 1823mm (complies with EN81-70: 5.2.4)
Lowest beam 25mm (complies with EN81-70: 5.2.4)
Maximum recommended opening 3000mm
Minimum recommended opening 0mm
Vertical displacement at 0mm ± 20mm
Horizontal displacement at 0mm ± 10mm
Angular displacement at 0mm
Longitudinal ± 25°
Transversal ± 5°
Maximum response time 48mS
Light immunity at 2500mm Sunlight 100,000 Lux
IP rating RX & TX unit IP65 (IEC60529: 2001)
Electromagnetic Compatibility
Emission BS EN 12015: 2004 — Lifts, escalators and passenger conveyors
Immunity BS EN 12016: 2004 — Lifts, escalators and passenger conveyors
Cable reliability IEC 60227-2: 2003
Vibration IEC 60068-2-64: 1993
Free fall IEC 60068-2-32: 1975
Composite temperature/humidity IEC60068-2-38: 1974
cyclic test
Power Supply Options
Option 1: 10-30V DC Maximum current consumption 120mA
Option 2: 10-40V DC Maximum current consumption 120mA
Optically isolated solid state relay. Maximum load 200mA / 40V DC
Two output options Maximum load 100mA / 53V DC
available: N/O or N/C contact
With Optional AC Power Supply (MS720):
IP Rating IP65 (IEC 60529: 2001)
Rated Voltage 100 - 240V AC
Operating Voltage Range 93 - 276V AC
Output Voltage 12V DC. Regulated and short circuit protected
M150-SP150 DS V01 (GB)
Contact Type Single pole change over. Voltage free
Contact Rating 5A/250V AC, 10A/24V DC
This product is designed for use in elevators with powered automatic doors where the closing force is 25N/mm or less as per EN81 requirements. It should be installed
by qualified personnel only, therefore any use outside of this application is at the installer’s own risk and should be assessed appropriately.
As a result of our policy of continual improvement, the information in this document is subject to change without notice and it is intended only as general guidance on
product performance and suitability. This information shall not form part of any contract.
Avire Ltd
Unit 1, The Switchback T: 01628 540100
Gardner Road F: 01628 621 947
Maidenhead E: [email protected]
TL Jones is a brand of Avire Berkshire W: www.tljones.com
SL6 7RJ, UK W: www.avire-global.com