If the nPS activation in the did time is reached, switch off and on the instrument to 11.

11. INSTALLATION AND MOUNTING


restart normal regulation. Instrument XR30CX shall be mounted on vertical panel, in a
odc Compressor status with door open: no, Fan = normal; CPr; F_C = Compressor OFF. 29x71 mm hole, and fixed using the special bracket supplied.
rrd Outputs restart after doA alarm: no = outputs not affected by the doA alarm; yES =
The temperature range allowed for correct operation is 060
outputs restart with the doA alarm;
°C. Avoid places subject to strong vibrations, corrosive
HES Temperature increase during the Energy Saving cycle : (-30,0°C30,0°C/-22÷86°F)
gases, excessive dirt or humidity. The same
it sets the increasing value of the set point during the Energy Saving cycle.
recommendations apply to probes. Let air circulate by the
OTHER cooling holes.
Adr Serial address (1÷244): Identifies the instrument address when connected to a
ModBUS compatible monitoring system.
PbC Type of probe: it allows to set the kind of probe used by the instrument: PbC = PBC 12. ELECTRICAL CONNECTIONS
probe, ntc = NTC probe. The instrument is provided with screw terminal block to connect cables with a cross section up
onF on/off key enabling: nu = disabled; oFF = enabled; ES = not set it. to 2,5 mm2. Before connecting cables make sure the power supply complies with the
dP1 Thermostat probe display instrument’s requirements. Separate the probe cables from the power supply cables, from the
dP3 Third probe display- optional. outputs and the power connections. Do not exceed the maximum current allowed on each
dP4 Fourth probe display. relay, in case of heavier loads use a suitable external relay.
rSE Real set point: (readable only), it shows the set point used during the energy saving
cycle or during the continuous cycle. 12.1 PROBE CONNECTION
rEL Software release for internal use. The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid
Ptb Parameter table code: readable only. infiltration. It is recommended to place the thermostat probe away from air streams to correctly
measure the average room temperature. Place the defrost termination probe among the
8. DIGITAL INPUT (ENABLED WITH P3P = N)
evaporator fins in the coldest place, where most ice is formed, far from heaters or from the
The free voltage digital input is programmable in different configurations by the “i1F” warmest place during defrost, to prevent premature defrost termination.
parameter.
13. HOW TO USE THE HOT KEY
8.1 DOOR SWITCH INPUT (i1F = dor)
It signals the door status and the corresponding relay output status through the “odc” 13.1 HOW TO PROGRAM A HOT KEY FROM THE INSTRUMENT (UPLOAD)
parameter: no, Fan = normal (any change); CPr, F_C = Compressor OFF. 1. Program one controller with the front keypad.
Since the door is opened, after the delay time set through parameter “did”, the door alarm is 2. When the controller is ON, insert the “Hot key” and push o key; the "uPL" message
enabled, the display shows the message “dA” and the regulation restarts is rtr = yES. The appears followed a by flashing “End”
alarm stops as soon as the external digital input is disabled again. With the door open, the 3. Push “SET” key and the End will stop flashing.
high and low temperature alarms are disabled. 4. Turn OFF the instrument remove the “Hot Key”, then turn it ON again.
8.2 GENERIC ALARM (i1F = EAL) NOTE: the “Err” message is displayed for failed programming. In this case push again o key
As soon as the digital input is activated the unit will wait for “did” time delay before signalling if you want to restart the upload again or remove the “Hot key” to abort the operation.
the “EAL” alarm message. The outputs status don’t change. The alarm stops just after the
digital input is de-activated. 13.2 HOW TO PROGRAM AN INSTRUMENT USING A HOT KEY
(DOWNLOAD)
8.3 SERIOUS ALARM MODE (i1F = bAL)
1. Turn OFF the instrument.
When the digital input is activated, the unit will wait for “did” delay before signalling the “CA” 2. Insert a programmed “Hot Key” into the 5 PIN receptacle and then turn the
alarm message. The relay outputs are switched OFF. The alarm will stop as soon as the Controller ON.
digital input is de-activated. 3. Automatically the parameter list of the “Hot Key” is downloaded into the Controller
memory, the “doL” message is blinking followed a by flashing “End”.
8.4 PRESSURE SWITCH (i1F = PAL) 4. After 10 seconds the instrument will restart working with the new parameters.
If during the interval time set by “did” parameter, the pressure switch has reached the number 5. Remove the “Hot Key”..
of activation of the “nPS” parameter, the “CA” pressure alarm message will be displayed. The
compressor and the regulation are stopped. When the digital input is ON the compressor is NOTE the message “Err” is displayed for failed programming. In this case turn the unit off and
always OFF. then on if you want to restart the download again or remove the “Hot key” to abort the
If the nPS activation in the did time is reached, switch off and on the instrument to operation.
restart normal regulation.
14. ALARM SIGNALS
8.5 START DEFROST (i1F = dFr) Message Cause Outputs
It starts a defrost if there are the right conditions. After the defrost is finished, the normal “P1” Room probe failure Compressor output acc. to par. “Con” and
regulation will restart only if the digital input is disabled otherwise the instrument will wait until “COF”
the “MdF” safety time is expired.
“P3” Third probe failure Outputs unchanged
8.6 INVERSION OF THE KIND OF ACTION: HEATING-COOLING (i1F = Htr) “P4” Fourth probe failure Outputs unchanged
“HA” Maximum temperature alarm Outputs unchanged.
This function allows to invert the regulation of the controller: from cooling to heating and
“LA” Minimum temperature alarm Outputs unchanged.
viceversa.
"HA2" Condenser high temperature It depends on the “Ac2” parameter
8.7 ENERGY SAVING (i1F = ES) "LA2" Condenser low temperature It depends on the “bLL” parameter
The Energy Saving function allows to change the set point value as the result of the SET+ “dA” Door open Compressor according to rrd
HES (parameter) sum. This function is enabled until the digital input is activated. “EA” External alarm Output unchanged.
“CA” Serious external alarm All outputs OFF.
8.8 DIGITAL INPUTS POLARITY (i1F=bAL)
The digital input polarity depends on the “i1P” parameter. “CA” Pressure switch alarm All outputs OFF
i1P=CL: the input is activated by closing the contact. (i1F=PAL)
i1P=OP: the input is activated by opening the contact
14.1 ALARM RECOVERY
9. TTL SERIAL LINE – FOR MONITORING SYSTEMS
Probe alarms P1”, “P3” and “P4” start some seconds after the fault in the related probe; they
The TTL serial line, available through the HOT KEY connector, allows by means of the automatically stop some seconds after the probe restarts normal operation. Check
external TTL/RS485 converter, XJ485-CX, to connect the instrument to a monitoring system connections before replacing the probe.
ModBUS-RTU compatible such as the X-WEB500/3000/300. Temperature alarms “HA”, “LA” “HA2” and “LA2” automatically stop as soon as the
temperature returns to normal values.
10. X-REP OUTPUT – OPTIONAL
Alarms “EA” and “CA” (with i1F=bAL) recover as soon as the digital input is disabled.
As optional, an X-REP can be connected to the instrument, trough the HOY Alarm “CA” (with i1F=PAL) recovers only by switching off and on the instrument.
KEY connector. The X-REP output EXCLUDES the serial connection.
To connect the X-REP to the 14.2 OTHER MESSAGES
instrument the following Pon Keyboard unlocked.
connectors must be used CAB- PoF Keyboard locked
51F(1m), CAB-52F(2m), CAB-
noP In programming mode: none parameter is present in Pr1
55F(5m),
On the display or in dP2, dP3, dP4: the selected probe is nor enabled
noA None alarm is recorded.

1592020030 XR30CX GB m&M r1.1 27.03.2015 XR30CX 3/4