SRI983 Positioner Product Spesifications
SRI983 Positioner Product Spesifications
Product Specifications
04.2019 PSS EVE0103 A-(en)
The SRI983 Positioner is for operation of pneumatic valve actuators from control systems and electrical
controllers with electric control signals. It is used to reduce the adverse effects of valve friction, for higher thrust
and shorter positioning time.
FEATURES
• Independent adjustment of stroke range and zero • Mounting according to IEC 534, part 6 (NAMUR)
• Adjustable amplification and damping • Rotation adapter for angles up to 120 °
• Split range up to 3-fold possible • Mounting onto any linear or rotary actuator
• One version for 4-20 mA input • Explosion protection:
• Supply pressure up to 6 bar (90 psig) II 2 G Ex d and II 1 G Ex ia according to ATEX, or
explosion proof, intrinsic safety acc. to FM and
• Low vibration effect in all directions CSA, and CU TR
• EMC in accordance with the international standards
and laws (CE)
Connection Mounting
Pneumatic .............................. Female threads Type of mounting................... for attaching to
Q 1/4-18 NPT diaphragm actuators
acc. to DIN 45 141 acc. IEC 534-6 (NAMUR)
Electric ....................for attaching to
Line entry rotary actuators
Explosion protection Mounting orientation.............. any
acc. to ATEX Ex d........... Female threadM20 x 1.5
acc. to FM and CSA ....... Female threadQ1/2-14NPT Gauges
Note the section “Safety requirements” Indicating range
Terminals ............................ Screw terminals Internal I/P-output .................. 0 to 1.6 bar (0 to 23 psig)
Output ..................................... 0 to 10 bar (0 to 150 psig)
Error limit ................................ class 1.6
SAFETY REQUIREMENTS
Safety .................................... safety class III In the case of operation of the positioner in explosion
as per DIN EN 61010-1 / DIN IEC 61010-1 / VDE 0411 part 1 hazardous areas with an ambient temperature of more than
overvoltage category ............ 1 60 °C, it must be ensured that the connecting cable and
cable entry meet the increased thermal demands (max.
internal fuses ......................... none
ambient temperature plus 10 K).
external fuses ........................ Limitation of power supplies
Electrical connection with cable and wiring entry glands in
for fire protection has to be
accordance with special certification to explosion proof
observed due to EN 61010-1
classification EN 50 018, using suitable cable and wiring or
9.3. ff.
with conduit in accordance with special certification to
Electrical Classification 1) 2) explosion proof classification EN 50 018. A spark barrier
Type of protection “flameproof”, ATEX sealing compound must be applied directly at the point of
Type of protection ................. II 2 G Ex d IIB+H2 T6 entry.
Certificate of conformity ........ FM 14 ATEX 0022 X See Certificate of Conformity EX EVE0103 A
Ta = –40°C to +75°C
Type of protection “Intrinsically Safe”, ATEX Explosion protection according to FM
Type of protection ................. II 1 G Ex ia IICT4 IS / I, II, III / 1 / ABCDEFG / T4
Certificate of conformity ........ FM 14 ATEX 0022 X I / 0 / A Ex ia IIC/ T4
Ta = –55°C to +85°C NI / I / 2 / ABCD / T4
S / II, III / 2 / EFG T4
Type of protection “dust”, ATEX I / 2 / IIC / T4
Type of protection ................. II 2 D Ex tD A21 IP65 T85°C XP / I / 1 / BCD/ T6
Certificate of conformity ........ FM 14 ATEX 0022 X DIP / II, III / 1 / EFG / T6
Ta = –40°C to +75°C I / 1 / A Ex d IIB+H2 / T6
Type of protection “non incendive”, ATEX 21 / A Ex tD / T85°C
Type of protection ................. II 3 G Ex nA nL IIC T6 Type 4X, IP65
Certificate of conformity ........ FM 14 ATEX 0023 X
Ta = –55°C to +85°C Explosion protection according to CSA
Type of protection ................. II 3 G Ex nL IICT4 IS / I, II, III / 1 / ABCDEFG / T4
Certificate of conformity ........ FM 14 ATEX 0023 X I / 0 / Ex ia IIC/ T4
Ta = –55°C to +85°C NI / I / 2 / ABCD / T4
II, III / 2 / EFG / T4
XP / I / 1 / BCD/ T6
DIP / II, III / 1 / EFG / T6
I / 1 / Ex d IIB+H2 / T6
Type 4X, IP65
1 .6 9
4 3
2 1
2 .1 3
2 .1 3
5 4
5 4
2 .8 0
2 .8 0
7 1
7 1
9 9
6 .8 5
1 7 4
4 9 ,5
1 .9 5
F e e d b a c k le v e r
C o d e E B Z G -A N , -F N , -G N
C o d e E B Z G - B N ( e x te n d e d v e r s io n )
2 ,5
.1 0
7 .1 7
1 8 2
6 8 3 7 2 1 4
.2 4 3 .2 7 2 .8 3 .5 5
7 ,9 + 0 ,2
.3 1 + .0 1
.7 8
2 0
1 0
.3 9
9 1 4 9 1 1 5
3 .5 8
M o u n tin g b r a c k e t
a c c o r d in g to IE C 5 3 4 - 6 ( N A M U R )
fo r C o d e E B Z G -G N , F N
9 6
3 .7 8 8 m m
in
9 4 .3 1
.3 5 4 3 .1 6
1 .6 9
2 0
C o r r ie r b o lt
3 0
1 .6 9
4 3
fo r a tta c h m e n t to v a lv e s te m
.3 5
9
.3 5
9
7 ,8 -0 ,0 5
.3 1 -.0 0 2
4 .5 7
1 1 6
M 6
1 6
2 .0 5
5 2
2 .8 0
7 1
1 0
6 5 .3 9
2 .5 6
.4 3
1 1
6 ,5
.2 6
.8 3
2 1
7 2
2 .8 3
.3 1
8
8 0
3 .1 5
PSS EVE0103 A-(en)
SRI983 ATTACHMENT KITS Page 7
W ith s h a ft
( a c c o r d in g to V D I/V D E 3 8 4 5 ) H o u s in g d im e n s io n s
C o d e E B Z G -Z N A tta c h m e n t k it w ith s h a ft C o d e E B Z G - Z N
r e s p . w ith o u t fla n g e C o d e E B Z G - N N
4 3 9 5
1 .6 9 3 .7 4
1 4 1 ,5
5 .5 7
5 0 M 6
M 6 x 1 4 (2 x )
D IN 9 1 2 1 .9 7
D e ta il Z
1 4
1 .1 8
3 0
2 .5 2
.5 5
6 4
.4 7
1 2
3 .9 0
9 9
1 .1 0 + .0 2
2 8 + 0 ,5
4 ,5
.1 8
1 6 H 8
.6 3
4
.3 1
8
.1 6
6
.5 3 1 6 7
6 .5 7
1 3 ,5
.5 3
W ith o u t fla n g e
C o d e E B Z G -N N , -P N
H o u s in g d im e n s io n s
A tta c h m e n t k it w ith o u t fla n g e
C o d e E B Z G -P N
1 4 1 ,5
5 .5 7
4 3 9 5
1 .6 9 3 .7 4
4 5 0 ,2
1 .7 7 .0 1
1 .1 8
6 ,5 1 4 - 6
3 0
/
.2 6 .5 5 - .2 4
D e ta il Y 1 1
.4 3
2 .5 2
6 4
.4 7
1 ,2
.0 5
1 2
3 .9 0
9 9
2 2
.8 7
.0 1
A d a p tio n o f th e a c tu a to r d r iv e s h a ft e n d
0 ,2
a n d c o r r e c t a x ia l lo c a tio n b y c lie n t !
.5 9
1 5
1 4 ... 1 5 ,5 1 6 7
M 6
1 6 .5 5 ... .6 1 6 .5 7
.4 7
1 2
.6 3
W ith fla n g e
C o d e E B Z G -J N
1 8 1 ,5
7 .1 5
.4 7
1 2
.3 9
1 0
.0 1
0 ,2
2 .7 6
.0 1
0 ,2
7 0
2 .9 5
7 5
.2 0
5
2 .3 6
6 0
m m 6
.2 4 5 0
.1 2
4 7
3
in
1 .9 7
1 .8 5
5 4
5
6,
.3 9
1 0
2 .1 3
.2
6 3
2 .4 8
8 6
3 .3 9 R o ta tio n a n g le m a x 1 2 0 ° ; to r q u e r e q u ir e m e n t 1 4 N m
PSS EVE0103 A-(en)
Page 8 SRI983
DIMENSIONS, CONNECTIONS
1 1 1 1 0 5
8 ,8 5 8 (9 3 **)
4 .3 7
m m 4 .1 3
6 2 ,5
.3 5 2 .2 8 (3 .6 6 * * ) in 2 .4 6
4 7 ,5
1 .8 7
2 .8 3
7 2
3 .9 4
1 0 0
7 .1 7
1 8 2
.6 7
1 7
.6 7
1 7
4
2 .9 3
7 4 ,5
1 0 6 ,5
1 3 8 4 .1 9
5 .4 3
5 1 6 7 8 9
1 1
.4 3
Schneider Electric Systems USA, Inc. Global Customer Support Copyright 2010-2019 Schneider Electric
38 Neponset Avenue Inside U.S.: 1-866-746-6477 Systems USA, Inc. All rights reserved.
Foxboro, MA 02035 Outside U.S.:1-508-549-2424
United States of America https://pasupport.schneider-electric.com **Schneider Electric is a trademark** of
http://www.schneider-electric.com Schneider Electric Systems USA, Inc., its
subsidiaries, and affiliates. All other trademarks
are the property of their respective owners.