Data sheet for Smart Line Modules Booksize
Article No. : 6SL3130-6TE21-6AA4
Figure similar
Client order no. : Item no. :
Order no. : Consignment no. :
Offer no. : Project :
Remarks :
Electrical data Rated data
Input Infeed power
Number of phases 3 AC Rated value 16.0 kW (18.0 hp)
Line voltage 342 ... 528 V for S6 duty 21.0 kW
Line frequency 47 ... 63 Hz Maximum 35.0 kW
Short-circuit strength 1) 65 kA Regenerative feedback power
Line power factor Rated value 16.0 kW (18.0 hp)
Fundamental power factor, minimal 0.96 for S6 duty 21.0 kW
Total 0.65 ... 0.90 Maximum 35.0 kW
Overvoltage category Class III DC-link current
DC link voltage 2) at 540 V DC 30.0 A
DC-link voltage 1.35 × line voltage at 600 V DC 27.0 A
Electronics power supply with DC 24 V (-15 % / 20 %) for S6 duty 35.0 A
Maximum 59.0 A
Connections
Input current
Line side
at 380 V AC 3-phase 29.0 A
Design screw-type terminal (X1)
at 400 V AC 3-phase 27.5 A
Conductor cross-section 2.5 ... 10 mm² (AWG 14 ... AWG 8)
at 480 V AC 3-phase 24.5 A
PE conductor M5 screw
at 400 V S6 duty 35.0 A
Cable shield connection plate integrated
Shield connecting kit into the connector at 400 V, maximum 57.5 A
Line length, max. Current requirement at 24 V DC,
0.95 A
maximum
Shielded 630 m (2,066.93 ft)
Ampacity of the busbars
Unshielded 850 m (2,788.71 ft)
for electronics power supply at
20 A
24 V DC
Mechanical data
for DC-link connection 100 A
Degree of protection IP20 / UL open type
DC link capacitance
Type of construction Booksize
of the Smart Line Module 710 µF
Net weight 7.0 kg (15.43 lb)
of the drive system, maximum 20,000 µF
Dimensions
Width 100 mm (3.94 in) General technical specifications
Height 380 mm (14.96 in) Sound pressure level 60 dB
Depth 270 mm (10.63 in) Losses 4) 0.190 kW
Standards Ambient conditions
Compliance with standards CE, cULus Ambient temperature in operation 0 ... 40 °C (32 ... 104 °F)
Cooling air throughput 0.016 m³/s (0.565 ft³/s)
Installation altitude 1,000 m (3,280.84 ft)
Type of cooling Internal air cooling
Standard: No radio interference
suppression; With line filter: Category
RI suppression C2 to EN 61800‑3 Total cable length up
to 350 m (1148 ft) (shielded)
1) in conjunction with the recommended Class J fuse, or circuit breaker according to UL489 / CSA 22.2 No. 5-02
2) The DC link voltage is maintained at the mean value of the rectified line voltage.
4) Power loss of the Smart Line Module with rated power including losses of the 24 V DC electronics power supply
Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 1 Generated Wed Sep 25 14:21:15 CET 2024