PROJECT SUMMARY

11 SHELLEY ST, HEIDELBERG


HEIGHTS
4 X TOWNHOUSES

DRAWING LIST - TOWN PLANNING


NO. SHEET TITLE REV. DATE Current Revision Description

TP.00 PROJECT SUMMARY D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.200 GROUND FLOOR PLAN D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.201 FIRST FLOOR PLAN D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.202 ROOF PLAN D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.300 ELEVATIONS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.301 ELEVATIONS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.302 FINISHES SCHEDULE D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.400 CATCHMENT PLAN D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.500 GARDEN AREA PLAN D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.600 9AM SHADOWS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.601 10AM SHADOWS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.602 11AM SHADOWS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.603 12PM SHADOWS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.604 3PM SHADOWS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.700 LANDSCAPE PLAN D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.900 SWEPT PATHS D AUG 2024 Issue in response to Council RFI dated 22.08.2024
TP.901 ESD PLANS D AUG 2024 Issue in response to Council RFI dated 22.08.2024

DEVELOPMENT SUMMARY
Name Area

TOTAL SITE AREA 604.19 m²

SITE COVERAGE
Name Area % OF SITE

SITE COVERAGE 289.17 m² 47.86%

PERMEABILITY
Name Area % SITE
D.01 AREA SCHEDULE D.02 AREA SCHEDULE D.03 AREA SCHEDULE D.04 AREA SCHEDULE
PERMEABLE AREA 216.59 m² 35.8%
Name Area Name Area Name Area Name Area
216.59 m² 35.8%
D.01 GARAGE 22.20 m² D.02 GF 49.91 m² D.03 GF 45.58 m² D.04 GF 60.84 m²
D.01 GF 27.53 m² D.02 GARAGE 21.00 m² D.03 TANDEM 12.74 m² D.04 CARPORT 33.00 m²
D.01 FF 56.28 m² D.02 FF 52.18 m² CARSPACE D.04 FF 57.49 m² GARDEN AREA
106.00 m² D.02 TANDEM 12.74 m² D.03 FF 41.49 m² 151.33 m² Name Area % OF SITE
CAR SPACE 99.81 m²
135.83 m² GARDEN AREA 182.41 m² 30.19%

D.01 OPEN SPACE SCHEDULE D.02 OPEN SPACE SCHEDULE D.03 OPEN SPACE SCHEDULE D.04 OPEN SPACE SCHEDULE
Name Area Name Area Name Area Name Area

D.01 FOS 31.76 m² D.02 BALCONY 9.87 m² D.03 POS 42.54 m² D.04 POS 38.28 m²
D.01 BALCONY 11.89 m² D.02 FOS 26.96 m² D.03 FOS 12.46 m² D.04 FOS 3.63 m²
43.65 m² D.02 POS 16.41 m² 55.00 m²
D.02 TANDEM 12.74 m²
CAR SPACE
65.98 m²

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title PROJECT SUMMARY Drawing Number TP.00 - Concept Issue 27/02/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 A Issue to Lodge 19/03/2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 person without the prior written consent of the company.

Drawn by KE C Issue in response to council RFI dated 16.07.2024 JULY 2024


All dimensions must be verified on site prior to commencement of
D Issue in response to Council RFI dated 22.08.2024 AUG 2024 work or establishment of any shop drawings. Figured dimensions
Checked by GM
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
LEGEND
LANDSCAPING (INDICATIVE ONLY)
REFER TO LANDSCAPING PLAN FOR DETAILS

AHD. 00.000
FINISH FLOOR LEVEL TO AHD.

CONC.
XWAY
74
EXTERNAL LIGHT WITH MOTION DETECTOR. WALL

.82
MOUNTED.

R
MAIL MAIL BOX

76
MB METER BOX

.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET GM GAS METER

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK, WM WATER METER

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE 1230
SINGLE STOREY BRICK RESIDENCE F1 TIMBER PAILING FENCE

CONCRETE PATH
F2 VERTICAL ALUMINIUM BLADE FENCE AT 1.2m HEIGHT
HW

VERANDAH
HW TAP TAP
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H FW FLOOR WASTE
74.81 S TOP OF WALL
HW 76.27 2975
MD METAL DECK ROOFING
72.48 H HW

72
HW 72.48 H ROOF SLOPE

.25
70.83 S SCREENED D.01, D.02 & D.04 SHARED BIN AREA
70.69 S

E
71.66 H 3 x 120L BINS (GENERAL RUBBISH),

S.P.O.S TOP OF WALL 71.14 S


3 x 240L BINS (RECYCLING),
3 x 240L BINS (FOOD & GARDEN ORGANICS),

CONC. KERB & CHANNEL


TP.300 TP.301
73.16 3 x BINS (GLASS). CAPACITY TBC.
FLOOR ABOVE
S.P.O.S 900mm HIGH ALUMINIUM BATTEN FENCING &

.94
2.0M HIGH PALING FENCE

.71

.83
CONCRETE PAVING TO BIN AREA.

.94
S.P.O.S

.88

69
D.03 BIN AREAS
TREE 14

.81

.65
3 3

69

69
69

.71
BALCONY ABOVE

69
1 x 120L BINS (GENERAL RUBBISH),

1000

69

69

.74
1 x 240L BINS (RECYCLING),

69
00 1 x 240L BINS (FOOD & GARDEN ORGANICS),
87° 13' 00" 35.26M

69
20 2500

EASEMENT
PROPOSED CONCRETE CROSSOVER
R 24 R
1 x BINS (GLASS). CAPACITY TBC.
SITE BOUNDARY TO BE CONSTRUCTED TO THE SATISFACTION EASEMENT

1830
00 Z TO BOUNDARY

0
SR SPLAY OF THE RESPONSIBLE AUTHORITY
SCREEN PLANTING

00
TPZ

R1
.68
TO BOUNDARY SELECTED PERMEABLE PAVING
SCREEN PLANTING
1.7M HIGH PALING FENCE

69

300
PEDESTRIAN VISIBILITY SPLAY

EASEMENT
4900 THE SPLAYS MUST BE AT LEAST 50% CLEAR OF

DRIVEWAY
300

1830
ANY VISUAL OBSTRUCTIONS (STRUCTURES, SELECTED CONCRETE DRIVEWAY (PERMEABLE)

3000
ACE PERMEABLE

4360
D.03 TANDEM CAR SP
VEGETATION AND THE LIKE). THE SPLAYS MAY

CONC.
3955

XWAY
TP.301

EASEMENT
INCLUDE AN ADJACENT ENTRY OR EXIT LANE
PAVING
4.9m x 2.6m

1.8M FENCE
DRIVEWAY: WHERE MORE THAN ONE LANE IS PROVIDED,
SELECTED TIMBER DECKING

1830

4205
2600
& GATE
TO BE FINISHED IN MUTED TONES OR ADJACENT LANDSCAPED AREAS, PROVIDED

3300
80 1:80 MAX. SLOPE

DRIVEWAY
TO SOFTEN APPEARANCE & BLEND THE LANDSCAPING IN THESE AREAS IS LESS
46 AY

2870
6

4180

3205
WITH VEGETATION. THAN 900MM IN HEIGHT.
EW SELECTED TIMBER FLOOR BOARDS
FSD ABOVE IV 1:80 MAX. SLOPE
DR
S.P.O.S
D.01-D.04
450mm PROJECTION MB
WINDOW H: 1800mm MONA LISA D.01-D.04 MAIL MAILBOXES D.01-D.04
2KL BIKE RACK SELECTED FLOOR TILES

AC
EV 5240 & WM DIMENSIONS, PLACEMENT & NUMBERING TO COMPLY

400
RWT WITH AUTRALIA POST - LETTERBOX SECURITY &
3625 CHARGER
.70 1.9 HIGH C'BOND FENCE

SPLAY
SPECIFICATION AS PUBLISHED ON AUSTRALIA POST

2000
VB 1200 2500 SELECTED CARPET
SCREEN PLANTING TO BOUNDARY

WEBSITE TO THE SATISFACTION OF RESPONSIBLE

1000

500
8370 AUTHORITY.
WC
HWU D.01 PATH SPLAY 2 TP.101
15 SHR

1535
D.03 POS 20 SELECTED GARDEN BED

SLIDING DOOR H: 2700mm


SK
DRIVEWAY:
ENS WIR

1085
WM/DM FW
R
3 LOT 2 MILTON COURT FSD ABOVE TO BE FINISHED IN MUTED TONES

450mm PROJECTION
675mm PROJECTION LDRY

WINDOW H: 1800mm
1310 1600
42.54 m² 450mm PROJECTION TO SOFTEN APPEARANCE & BLEND
1 TP.300
D.03 FOS SELECTED GRASS

3235
DOUBLE STOREY BRICK & REND
WINDOW H: 1800mm WITH VEGETATION.

ASD ABOVE:
ASD ABOVE

EV CHARGER

.80
D

.94
12.46 m² 6565 6000 D.01 FOS

.89
RESIDENCE

69
LIVING, KITCHEN & DINING BED 01 1 TP.301

69
5400

69
1HW DRIVEWAY MONA LISA
31.76 m²
NOTES.
ASD
TP.300 2 AHD 70.000
69

450mm PROJECTION BIKE RACK 600

SHELLEY STREET
6m3 STORAGE

74.90 H WINDOW H: 180mm 3000


D.03 GF D.01 GARAGE

.79
74.40 S

SITE BOUNDARY
2KL

900
TP.301 2 COL

.70
NO FRONT FENCE PROPOSED
COL

3700
D.01 GF - DOUBLE GLAZING (OR BETTER) TO BE USED TO ALL HABITABLE AREAS

69
SK 45.58 m² UNDERGROUND
300mm PROJECTION
ASD ABOVE

WINDOW H: 600mm

22.20 m²

69
HW

D.03 PATH
AHD 70.000 RWT
AHD 69.850 27.53 m²
SITE BOUNDARY

RH

D.01 PORCH
900
5 6

D.03 PORCH
TP.300 16

72.00 H OV DW
8305 15

1200
UP
76

6m3 STORAGE
71.00 S UP
600 750 600 900 1
.68

14
ECT LDRY 1
UNDER STAIRS 2
PDR
BANYULE LIVEABLE HOUSING
R

F/FREZ 2 13 12 11 10 9 8 7 6 5 4
P 600 1205 4725
CLOTHESLINE
3
0
600

CONCRETE PATH
16 15 14 13 12 11 10 9 8 7 6 5 4
OHC 4890
HWU R 33 21
3
75

HW 00 HT 6M
DESIGN GUIDELINES
R

180° 00' 00" 18.29M


Z
.16

SR
1.8M FENCE DRIVEWAY 9
10 11 2000
74.93 H
RH HWU 600 TPZ

D.04 PATH
D.04 FOS
E

3
600

CLOTHESLINE 15 14 13 12 11 10 9 8 7 6 5 4 8
700
LDRY WC

1000
ECT P 2 12
ENS
0° 00' 00" 16.03M

73.96 S F/FREZ

D.04 PORCH
3.63
R m²
SK 7

TREE 1
300mm PROJECTION

2120 600 900 1

2250
UP 5155
6 13

450mm PROJECTION
13

WINDOW H: 1800mm
WINDOW H: 600mm

OV
15 900 NOMINATED DWELLING COMPLIANT WITH BANYULE LIVEABLE HOUSING DESIGN GUIDELINES
1100

5 14
BED 01

3000
DW 4 15
ASD ABOVE

D.02 FOS

ASD ABOVE:
D.04 GF COL

1095
1090
VB FW

ROBE
3 16
CLEARANCE AREA

300mm PROJECTION
6700 VB

4090
WINDOW H: 600mm
60.84 m²
2 SHR
26.96 m²
6m3 STORAGE

D 1
900

AHD 70.000 UP LDRY

ASD ABOVE

LINEN
72.07 H BED 02 WM/ 3600 1. ACCESS TO THE DWELLING

CONC.
SK

XWAY
DM
5450

A CONTINUOUS ACCESSIBLE PATH OF TRAVEL FROM THE STREET TO THE DWELLING ENTRANCE.
D.04 POS
72

LIVING, KITCHEN & DINING BATH 3000


D.02 GF
HWU A CONTINUOUS ACCESSIBLE PATH OF TRAVEL FROM CAR PARKING AREAS TO THE MAIN
76

1200

D.02 PORCH
.39

38.28 m² AHD 70.000 900 PEDESTRIAN VISIBILITY SPLAY


870
ENTRANCE OR ANOTHER DWELLING ENTRY.
SLIDING DOOR H: 2700mm
.68

SPLAY
2710 THE SPLAYS MUST BE AT LEAST 50% CLEAR OF
E

ROBE 49.91 m²

2000
SCREEN PLANTING TO BOUNDARY

3 LOT 3 MILTON COURT


ANY VISUAL OBSTRUCTIONS (STRUCTURES,
D.02 PATH THE PATH OF TRAVEL MUST BE MINIMUM 1000 mm WIDE AND AT A MAXIMUM GRADIENT OF 1:14

.67
R

675mm PROJECTION

.78
CLOTHESLINE
VEGETATION AND THE LIKE). THE SPLAYS MAY

69
NOMINATED 3135 INCLUDE AN ADJACENT ENTRY OR EXIT LANE AND WITH A CROSSFALL NO GREATER THAN 1:40.

69
DOUBLE STOREY BRICK & REND 11.2m 2 BEDROOM D.04 CARPORT EV CHARGER 6000 COL 5755 WHERE MORE THAN ONE LANE IS PROVIDED,
ASD ABOVE

2500
ENS
HW OR ADJACENT LANDSCAPED AREAS, PROVIDED

6000
2.0M HIGH C'BOND FENCE

33.00 m²

1435
RESIDENCE

5
FW

.81
THE LANDSCAPING IN THESE AREAS IS LESS
2. ENTRANCE

.8
MONA LISA SPLAY
71.97 H 5600 500 4900 THAN 900MM IN HEIGHT.

69

69
VB WC 900
BIKE RACK
AT LEAST ONE LEVEL (STEP FREE) ENTRANCE INTO THE DWELLING THAT PROVIDES:
BED 01 SHR
D.02 GARAGE
70.92 S

3500
3450 DIRECT ACCESS FROM THE ACCESSIBLE PATH OF TRAVEL DESCRIBED ABOVE.
ROBE
1W
3500
EXISTING CONCRETE CROSSVER
AC
3200 D.02 POS 21.00 m² TO BE RETAINED. A LEVEL LANDING AREA OF 1200 mm x 1200mm, EXCLUSIVE OF THE SWING OF THE DOOR.
74.94 H 2KL RWT PERMEABLE PAVING

2600
AHD 69.850 A MINIMUM DOORWAY WIDTH OF 850mm.
450mm PROJECTION

MONA LISA
ASD ABOVE

16.41 m²
WINDOW H: 1800mm

3800
74.42 S BIKE RACK THE HEIGHT DIFFERENCE BETWEEN ABUTTING SURFACES MUST BE NO GREATER THAN 5 mm.
2030

2065
5500
D.02 TANDEM CAR SPACE
COL 2KL

.86
6m3 STORAGE 4.9m x 2.6m 3. CORRIDORS

AC
ENCROACHMENT

CONC.
EV CHARGER

.79
RWT

XWAY

.72
5800

69

.79
SCREEN PLANTING TO BOUNDARY

69
THE WIDTH OF INTERNAL CORRIDORS MUST BE A MINIMUM OF 1000 m.

69

69
.53
.64
SITE BOUNDARY 270° 53' 30" 35.22M R1

300
2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE 000

.63
.79
.51

.64

69
69
80
R 2 HT 3M

69
4 4 0

69
69
4. DOORWAYS
69

69
75

72

Z SR
P Z
.18

.08

T THE WIDTH OF DOORWAYS MUST BE A MINIMUM WIDTH OF 850 mm


E

TP.300 TP.301 .
TREE 2

.98
5. TOILET
71

69
.81

A TOILET ON GROUND FLOOR THAT PROVIDES:


E

S.P.O.S A CLEAR WIDTH OF 900mm AND A SPACE OF 1200mm (LENGTH) FORWARD OF THE PAN
CARPORT (EXCLUSIVE OF THE SWING OF THE DOOR) IF TOILET IS LOCATED IN A SEPARATE ROOM.
SHED REINFORCED WALLS TO ALLOW FOR FUTURE INSTALLATION OF GRAB RAILS.

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50

6. BATHROOM AND SHOWER


R

ACCESS TO A SHOWER ON THE GROUND FLOOR THAT PROVIDES:

.73
75

72

.62
A STEP FREE SHOWER AREA OF AT LEAST 900 mm x 900mm IN WIDTH AND LENGTH.

69
.00

RL AD
.59

69
S
A CLEAR SPACE IN FRONT OF THE SHOWER THAT IS 1200 mm x 1200mm IN WIDTH AND LENGTH.
R

INE
WE HE
TOP OF WALL REINFORCED WALLS TO ALLOW FOR FUTURE INSTALLATION OF GRAB RAILS.
75

D
.26

72.98 NHW HW (NOTE: IF THE TOILET AND SHOWER AREA ARE LOCATED IN THE SAME ROOM THE ABOVE

PO VER
E

72.30 H 72.134 H DIMENSIONS AND FEATURES SHOULD BE MAINTAINED FOR BOTH THE SHOWER AND THE TOILET.)
71.76 S 71.04 S

O
D 7. BEDROOM
71.97 H A ROOM ON THE GROUND FLOOR THAT COULD BE USED AS A BEDROOM THAT IS AT LEAST 10m 2

1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
12030
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE

.70
.77

.73

.60
69
69

69

69
13445

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title GROUND FLOOR PLAN Drawing Number TP.200 - Concept Issue 27/02/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 A Issue to Lodge 19/03/2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 person without the prior written consent of the company.

Drawn by KE C Issue in response to council RFI dated 16.07.2024 JULY 2024


All dimensions must be verified on site prior to commencement of
D Issue in response to Council RFI dated 22.08.2024 AUG 2024 work or establishment of any shop drawings. Figured dimensions
Checked by GM
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
LEGEND
LANDSCAPING (INDICATIVE ONLY)
REFER TO LANDSCAPING PLAN FOR DETAILS

AHD. 00.000
FINISH FLOOR LEVEL TO AHD.

CONC.
XWAY
74
EXTERNAL LIGHT WITH MOTION DETECTOR. WALL

.82
MOUNTED.

R
MAIL MAIL BOX

76
MB METER BOX

.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET GM GAS METER

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK, WM WATER METER

69
85 LOT 2 SOUTHERN ROAD 1230

TIMBER & TILE RESIDENCE


SINGLE STOREY BRICK RESIDENCE F1 TIMBER PAILING FENCE

CONCRETE PATH
F2 VERTICAL ALUMINIUM BLADE FENCE AT 1.2m HEIGHT
HW

VERANDAH
HW TAP TAP
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H FW FLOOR WASTE
74.81 S TOP OF WALL
HW 76.27 MD METAL DECK ROOFING
72.48 H HW 2975

72
HW 72.48 H ROOF SLOPE

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


TP.300 TP.301
73.16 FLOOR ABOVE
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
3 3

69

69
69

.71
BALCONY ABOVE

69

69

69

.74

69
87° 13' 00" 35.26M

69
SITE BOUNDARY EASEMENT

.68
SELECTED PERMEABLE PAVING
1.7M HIGH PALING FENCE

69

3945
3890
SELECTED CONCRETE DRIVEWAY (PERMEABLE)

3440

CONC.
XWAY
SELECTED TIMBER DECKING

4390
4150
FSD ABOVE
450mm PROJECTION

3490

4260
3285
SELECTED TIMBER FLOOR BOARDS

4015
WINDOW H: 600mm

450mm PROJECTION
WINDOW H: 1800mm
S.P.O.S
SELECTED FLOOR TILES

ASD ABOVE
.70 1.9 HIGH C'BOND FENCE

FSD 5800 1995

1000mm PROJECTION
EAVES ABOVE

SLIDING DOOR H: 2700mm


3840 250mm SHROUD PROJECTION 4800 SELECTED CARPET

D.01 BALCONY
WINDOW H: 600mm
VB 6265 900 VB LIVING, KITCHEN & DINING 2 TP.101
900 SELECTED GARDEN BED

11.89 m²
WC

3 LOT 2 MILTON COURT


WC

1400

1560
FW FW
ENSUITE
FW
BATH 1

900
TP.300 SELECTED GRASS

10345
DOUBLE STOREY BRICK & REND
SHR
SHR
SHR

0
250mm SHROUD PROJECTION
D

ROBE

.94

.8
.89
RESIDENCE

2385

69
ROBE WC 1 TP.301

69
GREY HATCH DENOTES 3600

69
5825
1HW BATH BED 02 D.01 FF AHD 73.010
NOTES.
TP.300 2 EXTENT OF RAKED CEILING
69

3475

SITE BOUNDARY
WINDOW H: 600mm
VB

SHELLEY STREET
ABOVE BED 01 & ENS
74.90 H 3000

5635
56.28 m²

800
AHD 73.000

.79
74.40 S TP.301 2 DW AHD 73.000

.70
- DOUBLE GLAZING (OR BETTER) TO BE USED TO ALL HABITABLE AREAS

69
BED 02

69
3225
HW
SITE BOUNDARY

3510

FSD
D.03 FF RCL

300mm PROJECTION
3670

1625
BED 01

WINDOW H: 600mm
5 TP.300 6 16

ROBE
72.00 H
300mm PROJECTION

41.49 m² DN
WINDOW H: 600mm

15
600 1365 600 900

ASD ABOVE
76

71.00 S
.68

OV 14
ASD ABOVE

1 SK F/FREZ

AC
ECT P

BANYULE LIVEABLE HOUSING


R

DN

600
2

180° 00' 00" 18.29M


13 12 11 10 9 8 7 6 5 4
RH

CONCRETE PATH
16 15 14 13 12 11 10 9 8 7 6 5 4
3 4725
75

HW HT 6M
DESIGN GUIDELINES
.16

9 RH P F/FREZ
ROBE OHC

600
10 11
74.93 H FSD
E

3
16 15 14 13 12 11 10 9 8 7 6 5 4 8 ECT
0° 00' 00" 16.03M

250mm SHROUD PROJECTION SK


DN 2 12
73.96 S 1
WINDOW H: 600mm
4850
7
6 13
600 1010
OV
600 900

1100
5 14 AHD 73.010 NOMINATED DWELLING COMPLIANT WITH BANYULE LIVEABLE HOUSING DESIGN GUIDELINES
3000 DN
BED 02 D.04 FF AHD 73.000
4 15
300mm PROJECTION
WINDOW H: 600mm

2110 1000

D.02 BALCONY
16
CLEARANCE AREA
3510

250mm SHROUD PROJECTION


57.49 m²

700
4090
DW
D

9.87 m²
ASD ABOVE

300mm PROJECTION
VB
BED 03

WINDOW H: 600mm
72.07 H 3000 1400 LIVING, KITCHEN & DINING D.02 FF 1. ACCESS TO THE DWELLING

WINDOW H: 600mm

CONC.
XWAY
BED 03 A CONTINUOUS ACCESSIBLE PATH OF TRAVEL FROM THE STREET TO THE DWELLING ENTRANCE.

ASD ABOVE
52.18 m²

5955
BATH BED 04
72

A CONTINUOUS ACCESSIBLE PATH OF TRAVEL FROM CAR PARKING AREAS TO THE MAIN

4090
GREY HATCH DENOTES ROBE
76

.39

5570
2500

ROBE

EXTENT OF RAKED CEILING ENTRANCE OR ANOTHER DWELLING ENTRY.


.68

WC 3000
E

FSD
3000

7845
ABOVE BED 02 & ENS ASD ABOVE:
3 LOT 3 MILTON COURT THE PATH OF TRAVEL MUST BE MINIMUM 1000 mm WIDE AND AT A MAXIMUM GRADIENT OF 1:14

.67
R

900

.78
SHR 675mm PROJECTION

69
ENSUITE 900 SLIDING DOOR H: 2700mm AND WITH A CROSSFALL NO GREATER THAN 1:40.

69
DOUBLE STOREY BRICK & REND
900

FW
1580

FW
BATH
HW 3600 6685
2.0M HIGH C'BOND FENCE

1435
RESIDENCE

.85
WC FW

.81
VB
ROBE 2. ENTRANCE
71.97 H WC AHD 73.000

69
SHR 1650

69
3675 VB
SHR
5290
6170 AT LEAST ONE LEVEL (STEP FREE) ENTRANCE INTO THE DWELLING THAT PROVIDES:
70.92 S 6175 DIRECT ACCESS FROM THE ACCESSIBLE PATH OF TRAVEL DESCRIBED ABOVE.
1W A LEVEL LANDING AREA OF 1200 mm x 1200mm, EXCLUSIVE OF THE SWING OF THE DOOR.
74.94 H
2875

A MINIMUM DOORWAY WIDTH OF 850mm.


74.42 S
2375

2375

THE HEIGHT DIFFERENCE BETWEEN ABUTTING SURFACES MUST BE NO GREATER THAN 5 mm.

2140

1800

.86
3. CORRIDORS

CONC.
.79

XWAY

.72
69

.79
69
THE WIDTH OF INTERNAL CORRIDORS MUST BE A MINIMUM OF 1000 m.

69

69
.53
.64
SITE BOUNDARY 270° 53' 30" 35.22M 2.0M HIGH PALING FENCE

7
1.9M HIGH PALING FENCE

.63
.79
1

.64

.8

69
69
.5

HT 3M

69
4 4

69
69
4. DOORWAYS
69

69
75

72
.18

.0

THE WIDTH OF DOORWAYS MUST BE A MINIMUM WIDTH OF 850 mm


8E
E

TP.300 TP.301 .

.98
5. TOILET
71

69
.81

A TOILET ON GROUND FLOOR THAT PROVIDES:


E

S.P.O.S A CLEAR WIDTH OF 900mm AND A SPACE OF 1200mm (LENGTH) FORWARD OF THE PAN
CARPORT (EXCLUSIVE OF THE SWING OF THE DOOR) IF TOILET IS LOCATED IN A SEPARATE ROOM.
SHED REINFORCED WALLS TO ALLOW FOR FUTURE INSTALLATION OF GRAB RAILS.

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50

6. BATHROOM AND SHOWER


R

ACCESS TO A SHOWER ON THE GROUND FLOOR THAT PROVIDES:

.73
75

72

.62
A STEP FREE SHOWER AREA OF AT LEAST 900 mm x 900mm IN WIDTH AND LENGTH.

69
.00

RL AD
.59

69
S
A CLEAR SPACE IN FRONT OF THE SHOWER THAT IS 1200 mm x 1200mm IN WIDTH AND LENGTH.
R

INE
WE HE
TOP OF WALL REINFORCED WALLS TO ALLOW FOR FUTURE INSTALLATION OF GRAB RAILS.
75

D
.26

72.98 NHW HW (NOTE: IF THE TOILET AND SHOWER AREA ARE LOCATED IN THE SAME ROOM THE ABOVE

PO VER
E

72.30 H 72.134 H DIMENSIONS AND FEATURES SHOULD BE MAINTAINED FOR BOTH THE SHOWER AND THE TOILET.)
71.76 S 71.04 S

O
D 7. BEDROOM
71.97 H A ROOM ON THE GROUND FLOOR THAT COULD BE USED AS A BEDROOM THAT IS AT LEAST 10m 2

1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET 12030


SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE

.70
.77

.73

.60
69
69

69

69
13445

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title FIRST FLOOR PLAN Drawing Number TP.201 - Concept Issue 27/02/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 A Issue to Lodge 19/03/2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 person without the prior written consent of the company.

Drawn by KE C Issue in response to council RFI dated 16.07.2024 JULY 2024


All dimensions must be verified on site prior to commencement of
D Issue in response to Council RFI dated 22.08.2024 AUG 2024 work or establishment of any shop drawings. Figured dimensions
Checked by GM
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
LEGEND
LANDSCAPING (INDICATIVE ONLY)
REFER TO LANDSCAPING PLAN FOR DETAILS

AHD. 00.000
FINISH FLOOR LEVEL TO AHD.

CONC.
XWAY
74
EXTERNAL LIGHT WITH MOTION DETECTOR. WALL

.82
MOUNTED.

R
MAIL MAIL BOX

76
MB METER BOX

.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET GM GAS METER

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK, WM WATER METER

69
85 LOT 2 SOUTHERN ROAD 1230
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE F1 TIMBER PAILING FENCE

CONCRETE PATH
F2 VERTICAL ALUMINIUM BLADE FENCE AT 1.2m HEIGHT
HW

VERANDAH
HW TAP TAP
71.91 H 71.91 H 1W 2975

70.76 S 70.91 S 75.38 H FW FLOOR WASTE


74.81 S TOP OF WALL
HW 76.27 MD METAL DECK ROOFING
72.48 H HW

72
HW 72.48 H ROOF SLOPE

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


TP.300 TP.301
73.16 FLOOR ABOVE
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
3 3

69

69
69

.71
BALCONY ABOVE

69

69

69

.74

69
69
87° 13' 00" 35.26M EASEMENT
SITE BOUNDARY

SITE BOUNDARY
.68
SELECTED PERMEABLE PAVING
1.7M HIGH PALING FENCE

69
SELECTED CONCRETE DRIVEWAY (PERMEABLE)

CONC.
XWAY
TP.301
SELECTED TIMBER DECKING
6
SELECTED TIMBER FLOOR BOARDS

180° 00' 00" 18.29M


S.P.O.S
EAVES GUTTER SELECTED FLOOR TILES
.70 1.9 HIGH C'BOND FENCE

SELECTED CARPET
EAVES GUTTER 2 TP.101
SELECTED GARDEN BED

25°
3 LOT 2 MILTON COURT

25°
1 TP.300 SELECTED GRASS
DOUBLE STOREY BRICK & REND

.80
D

.94

.89
RESIDENCE ROOF FINISH TO MEET A

69
2° 1 TP.301

69

69
BOX GUTTER
1HW MAX. SOLAR ABSORPTANCE
EAVES GUTTER NOTES.
TP.300 2
69

SHELLEY STREET

74.90 H (SA) OF 0.70
SITE BOUNDARY

.79
74.40 S TP.301 2

.70
- DOUBLE GLAZING (OR BETTER) TO BE USED TO ALL HABITABLE AREAS

69
25°

69
HW ROOF FINISH TO MEET A
5 TP.300 6

25°
72.00 H MAX. SOLAR ABSORPTANCE
76

(SA) OF 0.70

BOX GUTTER
71.00 S
.68


BANYULE LIVEABLE HOUSING
R

CONCRETE PATH
BOX GUTTER
75

HW HT 6M
DESIGN GUIDELINES
0° 00' 00" 16.03M
.16

74.93 H BOX GUTTER


E

73.96 S ROOF FINISH TO MEET A


MAX. SOLAR ABSORPTANCE ROOF FINISH TO MEET A NOMINATED DWELLING COMPLIANT WITH BANYULE LIVEABLE HOUSING DESIGN GUIDELINES
(SA) OF 0.70 MAX. SOLAR ABSORPTANCE
(SA) OF 0.70
CLEARANCE AREA

25°
D
EAVES GUTTER


72.07 H 1. ACCESS TO THE DWELLING

CONC.
EAVES GUTTER

XWAY
25° 25° A CONTINUOUS ACCESSIBLE PATH OF TRAVEL FROM THE STREET TO THE DWELLING ENTRANCE.
72

A CONTINUOUS ACCESSIBLE PATH OF TRAVEL FROM CAR PARKING AREAS TO THE MAIN
76

.39

ENTRANCE OR ANOTHER DWELLING ENTRY.


.68

3 LOT 3 MILTON COURT THE PATH OF TRAVEL MUST BE MINIMUM 1000 mm WIDE AND AT A MAXIMUM GRADIENT OF 1:14

.67
R

.78

69
AND WITH A CROSSFALL NO GREATER THAN 1:40.

69
25°

DOUBLE STOREY BRICK & REND


HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
2. ENTRANCE

.8

71.97 H

69

69
EAVES GUTTER BOX GUTTER AT LEAST ONE LEVEL (STEP FREE) ENTRANCE INTO THE DWELLING THAT PROVIDES:
70.92 S BOX GUTTER DIRECT ACCESS FROM THE ACCESSIBLE PATH OF TRAVEL DESCRIBED ABOVE.
1W A LEVEL LANDING AREA OF 1200 mm x 1200mm, EXCLUSIVE OF THE SWING OF THE DOOR.
74.94 H A MINIMUM DOORWAY WIDTH OF 850mm.

74.42 S THE HEIGHT DIFFERENCE BETWEEN ABUTTING SURFACES MUST BE NO GREATER THAN 5 mm.

.86
3. CORRIDORS

CONC.
.79

XWAY
EAVES GUTTER EAVES GUTTER

.72
69

.79
69
THE WIDTH OF INTERNAL CORRIDORS MUST BE A MINIMUM OF 1000 m.

69

69
.53
.64
SITE BOUNDARY 270° 53' 30" 35.22M 2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE

.63
.79
.51

.64

69
69
HT 3M

69
4 4

69
69
4. DOORWAYS
69

69
75

72
.18

.08

THE WIDTH OF DOORWAYS MUST BE A MINIMUM WIDTH OF 850 mm


E

TP.300 TP.301 .

.98
5. TOILET
71

69
.81

A TOILET ON GROUND FLOOR THAT PROVIDES:


E

S.P.O.S A CLEAR WIDTH OF 900mm AND A SPACE OF 1200mm (LENGTH) FORWARD OF THE PAN
CARPORT (EXCLUSIVE OF THE SWING OF THE DOOR) IF TOILET IS LOCATED IN A SEPARATE ROOM.
SHED REINFORCED WALLS TO ALLOW FOR FUTURE INSTALLATION OF GRAB RAILS.

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50

6. BATHROOM AND SHOWER


R

ACCESS TO A SHOWER ON THE GROUND FLOOR THAT PROVIDES:

.73
75

72

.62
A STEP FREE SHOWER AREA OF AT LEAST 900 mm x 900mm IN WIDTH AND LENGTH.

69
.00

RL AD
.59

69
S
A CLEAR SPACE IN FRONT OF THE SHOWER THAT IS 1200 mm x 1200mm IN WIDTH AND LENGTH.
R

INE
WE HE
TOP OF WALL REINFORCED WALLS TO ALLOW FOR FUTURE INSTALLATION OF GRAB RAILS.
75

D
.26

72.98 NHW HW (NOTE: IF THE TOILET AND SHOWER AREA ARE LOCATED IN THE SAME ROOM THE ABOVE

PO VER
E

72.30 H 72.134 H DIMENSIONS AND FEATURES SHOULD BE MAINTAINED FOR BOTH THE SHOWER AND THE TOILET.)
71.76 S 71.04 S

O
D 7. BEDROOM
71.97 H A ROOM ON THE GROUND FLOOR THAT COULD BE USED AS A BEDROOM THAT IS AT LEAST 10m 2

1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND 12050

RESIDENCE

.70
.77

.73

.60
69
69

69

69
13445

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title ROOF PLAN Drawing Number TP.202 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by Author D Issue in response to Council RFI dated 22.08.2024 AUG 2024
All dimensions must be verified on site prior to commencement of
Checked by Checker work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
FINISHES LEGEND
LEGEND A
MATERIAL SELECTED RENDER
D.02 D.01 D.03 D.04 PRODUCT -
COLOUR COLORBOND BASALT
FINISH PAINT
AHD 77.751 DEPTH OF EXTERNAL SHADING DEVICES
TO BE AT LEAST 25% OF THE DISTANCE
FROM THE BOTTOM OF GLAZING TO LEGEND B

BOUNDARY

BOUNDARY
375
AHD 76.843 AHD 76.843

375
SHADING DEVICE.

BOUNDARY

BOUNDARY
D MATERIAL SELECTED RENDER
AHD 76.300 D PRODUCT -
PARAPET D.01 & D.02 ASD: 675mm ASD:
PROJECTION
PARAPET D.03 & D.04 B 300mm PROJECTION
WINDOWS H: 600mm
H COLOUR LIGHT GREY
SSL 76.300
600

B B SSL 76.100 FINISH PAINT

600
FIRST SCL D.01 & D.02 C B
FIRST SCL D.03 & D.04 B C C

600

600
SSL 75.700 LEGEND C
SSL 75.500 ASD:
MATERIAL SELECTED ALUMINIUM FRAMED GLAZING
2700

2500
675mm PROJECTION
SLIDING DOOR H: 2700mm
FRAME COLOUR COLORBOND MONUMENT

7750
AHD 73.300

1700

1700
ASD: AHD 73.400
F
675mm PROJECTION FRAME FINISH POWDERCOAT
A F

6845
6300 ASD: 450mm ASD: 450mm SLIDING DOOR H: 2700mm
FIRST PROJECTION PROJECTION
FIRST GLAZING CLEAR
A E E A
300

300
SSL 73.000 SSL 73.000
ASD:
GROUND SCL B GROUND SCL C A 300mm PROJECTION
C
ASD:
LEGEND D
A A A WINDOWS H: 600mm
450mm PROJECTION

4000
WINDOW H: 1800mm
SSL 72.700 G I B SSL 72.700 MATERIAL SELECTED TIMBER BATTENS/POSTS
3300

3300
I PRODUCT -
2700

2700
C C

600
C C C C COLOUR NATURAL
FINISH -

900
GROUND GROUND GROUND
NGL NGL
SSL 70.000 SSL 70.000 SSL 70.000
AHD 69.870 AHD 69.686 LEGEND E
AHD 69.932
AHD 69.544 MATERIAL SELECTED VERTICAL RENDER
PRODUCT -
COLOUR LIGHT GREY
FINISH PAINT
DWG REF. VIEW NAME. DWG REF. VIEW NAME.
1 EAST ELEVATION 2 WEST ELEVATION
DWG NUMBER. SCALE. LEGEND F
DWG NUMBER. SCALE.
MATERIAL SELECTED BALUSTRADE GLAZING
A.200 1 : 100 A.200 1 : 100 FRAME COLOUR MONUMENT
FRAME FINISH POWDERCOAT
GLAZING CLEAR

LEGEND G
MATERIAL SELECTED GARAGE DOOR, SHROUDS,
D.01 DEPTH OF EXTERNAL SHADING DEVICES D.04 D.03 D.04 D.03 DOWNPIPES, FASCIAS & GUTTERS
TO BE AT LEAST 25% OF THE DISTANCE DEPTH OF EXTERNAL SHADING DEVICES
FROM THE BOTTOM OF GLAZING TO TO BE AT LEAST 25% OF THE DISTANCE COLOUR MONUMENT
SHADING DEVICE. FROM THE BOTTOM OF GLAZING TO FINISH POWDERCOAT
AHD 77.751 SHADING DEVICE.

AHD 76.843 AHD 76.843


H AHD 76.843 AHD 76.843

BOUNDARY

BOUNDARY
LEGEND H
AHD 76.300
MATERIAL SELECTED METAL DECK ROOFING
BOUNDARY

PARAPET D.01 & D.02 H AHD 75.876


AHD 76.100
PARAPET D.03 & D.04 PARAPET D.03 & D.04 PRODUCT STAND SEAM
SSL 76.300 5°
600

FSD
B A B AHD 75.476 SSL 76.100 SSL 76.100 COLOUR LIGHT GREY

600

600
450mm PROJECTION FSD FSD B A B

BOUNDARY
FSD: FSD:
250mm PROJECTION 250mm PROJECTION FINISH -
FIRST SCL D.01 & D.02 A 250mm PROJECTION 250mm PROJECTION
B
C C C B FIRST SCL D.03 & D.04 FIRST SCL D.03 & D.04
600

600

600

600

600

600

600
SSL 75.700 AHD 74.500
SSL 75.500 SSL 75.500 LEGEND I

1800
2700

2500

2500
C MATERIAL SELECTED ENTRY DOOR
7750

AHD 73.400 D AHD 73.400


1700

1700

1700

1700

1700

1700

1700
AHD 73.300
6300

PRODUCT -
F AHD 73.150

6845

6845
COLOUR MONUMENT
FIRST FIRST FIRST ASD:

500
A FSD FSD
450mm PROJECTION
FINISH POWDERCOAT
B A
300

300

300
WINDOW H: 1800mm
SSL 73.000 450mm PROJECTION 450mm PROJECTION SSL 73.000 SSL 73.000

5755
GROUND SCL A A GROUND SCL
4500

B C GROUND SCL A A J
600

C C LEGEND

900

900
SSL 72.700 SSL 72.700
3400

SSL 72.700 MATERIAL SELECTED TIMBER PALING FENCE

1800
D.04 CARPORT
2700

2700

2700
D.04 CARPORT
PRODUCT -

900

900
-
1700

COLOUR NATURAL
AHD 70.000 FINISH -
GROUND GROUND GROUND

600

600

600
NGL
SSL 70.000 SSL 70.000 SSL 70.000
AHD 69.911 AHD 69.790
AHD 69.719 AHD 69.690
NOTES.

DWG REF. VIEW NAME. DWG REF. VIEW NAME. DOUBLE GLAZING (OR BETTER) TO BE USED TO ALL HABITABLE AREAS
3 NORTH ELEVATION 5 INTERNAL EAST ELEVATION
DWG NUMBER. SCALE. DWG NUMBER. SCALE.
A.200 1 : 100 A.200 1 : 100

DEPTH OF EXTERNAL SHADING DEVICES


TO BE AT LEAST 25% OF THE DISTANCE
D.04 D.02 D.01 FROM THE BOTTOM OF GLAZING TO D.02
SHADING DEVICE.

AHD 77.751

AHD 76.843 AHD 76.843

BOUNDARY
B

BOUNDARY
AHD 76.300 AHD 76.300
AHD 75.876 H PARAPET D.01 & D.02 PARAPET D.01 & D.02
PARAPET D.03 & D.04 ASD:
BOUNDARY

5° SSL 76.300 SSL 76.300

BOUNDARY

600

600
SSL 76.100 AHD 75.476 B B B 450mm PROJECTION
A
ASD: ASD:
B
600

WINDOW H: 1800mm 300mm PROJECTION 300mm PROJECTION


WINDOW H: 600mm WINDOW H: 600mm

A FIRST SCL D.01 & D.02


FIRST SCL D.03 & D.04 B C C C FIRST SCL D.01 & D.02
600

600

600

600

600

600
900
SSL 75.700
SSL 75.500 SSL 75.700
AHD 74.000

2700

2700
2500

900
ASD:
1700

1700

1700

1700

1700

1700
AHD 73.300 AHD 73.400 525mm PROJECTION AHD 73.400
6845

F WINDOW H: 2100mm
AHD 72.790
6300

FIRST FIRST FIRST

600
A
700

A A
300

300

300
SSL 73.000 SSL 73.000 SSL 73.000
GROUND SCL A A GROUND SCL A A A
C GROUND SCL
4000

1050

1050
600

WA
900

WA
SSL 72.700 LL LL O SSL 72.700
3400

AV ON NB
SSL 72.700 D.04 CARPORT
3115

MA G H BO D.04 CARPORT AVG OU


2815

2845
2860

ND
2700

2700

2700

2700
MA HEIG
3050

X H EIG UN ARY
3145

DA XH H
C EIG HT EIG T: 28
900

: RY

400 1050

400 1050
HT 30 HT: 50m
1700

: 3 97m 286 m
14 0mm
5m m
m
GROUND GROUND GROUND
600

SSL 70.000 NGL 6330 SSL 70.000 SSL 70.000


4055 AHD 69.690 AHD 69.790
D.02 GARAGE ON BOUNDARY
D.04 WALL ON BOUNDARY AHD 69.879
AHD 69.541

DWG REF. VIEW NAME. DWG REF. VIEW NAME.


4 SOUTH ELEVATION 6 INTERNAL WEST ELEVATION
DWG NUMBER. SCALE. DWG NUMBER. SCALE.
A.200 1 : 100 A.200 1 : 100

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title ELEVATIONS Drawing Number TP.300 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / As indicated read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
FINISHES LEGEND
LEGEND A
MATERIAL SELECTED RENDER
D.02 D.01 PRODUCT -
COLOUR COLORBOND BASALT
FINISH PAINT

D.03 D.04
AHD 77.751 DEPTH OF EXTERNAL SHADING DEVICES
TO BE AT LEAST 25% OF THE DISTANCE

BOUNDARY

BOUNDARY
FROM THE BOTTOM OF GLAZING TO FFL 76.843 LEGEND B
SHADING DEVICE.

BOUNDARY

BOUNDARY
D MATERIAL SELECTED RENDER
AHD 76.300 D
ASD: H
PRODUCT -
PARAPET D.01 & D.02 ASD: 675mm
PROJECTION
PARAPET D.03 & D.04 300mm PROJECTION
WINDOWS H: 600mm

SSL 76.300 B SSL 76.100


COLOUR LIGHT GREY
600

B FINISH PAINT

FIRST SCL D.01 & D.02 C B FIRST SCL D.03 & D.04 C C B
SSL 75.700 SSL 75.500 ASD: LEGEND C
675mm PROJECTION
MATERIAL SELECTED ALUMINIUM FRAMED GLAZING
2700

SLIDING DOOR H: 2700mm


FFL 73.400

1700

1700
ASD:
FRAME COLOUR COLORBOND MONUMENT

7750
AHD 73.300 675mm PROJECTION

6845
SLIDING DOOR H: 2700mm
6300
FRAME FINISH POWDERCOAT
F ASD: 450mm A ASD: 450mm F FIRST
FIRST PROJECTION PROJECTION
A GLAZING CLEAR
E E
SSL 73.000 A
A
300

SSL 73.000 ASD:


ASD:
B GROUND SCL C
300mm PROJECTION
C 450mm PROJECTION
GROUND SCL G A A A SSL 72.700
WINDOWS H: 600mm
WINDOW H: 1800mm LEGEND D

4000

3300
MATERIAL SELECTED TIMBER BATTENS/POSTS
SSL 72.700 I B
3300

I C C C PRODUCT -
2700

C C C COLOUR NATURAL
FINISH -
GROUND
GROUND SSL 70.000 NGL
NGL
SSL 70.000
AHD 69.870 LEGEND E
AHD 69.932 AHD 69.544
MATERIAL SELECTED VERTICAL RENDER
PRODUCT -
COLOUR LIGHT GREY
DWG REF. VIEW NAME. FINISH PAINT
DWG REF. VIEW NAME.
1 EAST ELEVATION (COLOUR) 2 WEST ELEVATION (COLOUR)
DWG NUMBER. SCALE. LEGEND F
DWG NUMBER. SCALE.
A.200 1 : 100 MATERIAL SELECTED BALUSTRADE GLAZING
A.200 1 : 100 FRAME COLOUR MONUMENT
FRAME FINISH POWDERCOAT
GLAZING CLEAR

LEGEND G
MATERIAL SELECTED GARAGE DOOR, SHROUDS,
DEPTH OF EXTERNAL SHADING DEVICES DOWNPIPES, FASCIAS & GUTTERS
TO BE AT LEAST 25% OF THE DISTANCE
FROM THE BOTTOM OF GLAZING TO FSD DEPTH COLOUR MONUMENT

FFL 77.751 D.01 SHADING DEVICE.


D.04 D.03 FINISH POWDERCOAT

H FFL 76.843 FFL 76.843


LEGEND H
FFL 76.300 65 65
MATERIAL SELECTED METAL DECK ROOFING
BOUNDARY

BATTEN GAP
PARAPET D.01 & D.02 AHD 75.876 PARAPET D.03 & D.04 PRODUCT STAND SEAM

WINDOW HEIGHT
SSL 76.300 FSD B A B AHD 75.476 SSL 76.100 COLOUR LIGHT GREY
450mm PROJECTION FSD FSD

BOUNDARY
250mm PROJECTION 250mm PROJECTION FINISH -
FIRST SCL D.01 & D.02 A
FFL 74.500 C C B FIRST SCL D.03 & D.04 DEPTH OF EXTERNAL SHADING DEVICES
SSL 75.700 C SSL 75.500 TO BE AT LEAST 25% OF THE DISTANCE LEGEND I
FROM THE BOTTOM OF GLAZING TO
A MATERIAL SELECTED ENTRY DOOR
7750

FFL 73.400 FFL 73.300 SHADING DEVICE.


B D
6300

PRODUCT -
F

6845

6845
COLOUR MONUMENT
FIRST FIRST
A FSD FSD FINISH POWDERCOAT
SSL 73.000 450mm PROJECTION 450mm PROJECTION A SSL 73.000

5755
GROUND SCL A A
4500

B C GROUND SCL LEGEND J


SSL 72.700 C C
3400

SSL 72.700 MATERIAL SELECTED TIMBER PALING FENCE


D.04 CARPORT
PRODUCT -
-
COLOUR NATURAL

GROUND GROUND FINISH -


NGL
SSL 70.000 SSL 70.000

AHD 69.939
NOTES.
AHD 69.719

DWG REF. VIEW NAME. DOUBLE GLAZING (OR BETTER) TO BE USED TO ALL HABITABLE AREAS
3 NORTH ELEVATION (COLOUR)
DWG NUMBER. SCALE.
A.200 1 : 100 FFL

DWG REF. VIEW NAME.


5 TYPICAL SECTION DETAIL - FIXED SHADING DEVICES
DWG NUMBER. SCALE.
1 : 20

D.04 D.02
FFL 76.843
FFL 76.300

AHD 75.876 PARAPET D.01 & D.02


PARAPET D.03 & D.04
BOUNDARY

SSL 76.300

BOUNDARY
FIRST SCL D.01 & D.02

600
SSL 76.100 AHD 75.476 B B
A SSL 75.700
FIRST SCL D.03 & D.04 B B
C C C
SSL 75.500 FFL 74.000

2700
500

D.01-D.04 METER BOXES


1700

1700

1700

FFL 73.300 FFL 73.400


6845

F
AHD 72.790
6300

FIRST FIRST 1000


A

300
SSL 73.000 A SSL 73.000 D.01-D.04 MAIL BOXES

GROUND SCL

D.01-D.04 METER BOXES


A
C GROUND SCL
4000

WA WA
SSL 72.700 LL LL O
3400

B
3300

D.01-D.04 MAIL BOXES


AV ON NB
SSL 72.700
3115

G AVG OU

1500
BO
2815

2845
2860

ND

2700
MA HE MA HEIG
3050

UN ARY
3145

X H IGH XH
C EIG T: 3
DA
RY EIG HT: 28
HT 097 HT: 50m

900
: 3 mm 286 m
14 0mm
5
GROUND GROUND GROUND
SSL 70.000 NGL 6330 SSL 70.000 SSL 70.000
4055
D.02 GARAGE ON BOUNDARY
D.04 WALL ON BOUNDARY AHD 69.879
AHD 69.541

DWG REF. VIEW NAME.

DWG REF. VIEW NAME.


6 ELEVATION - D.01-D.04 MAIL AND METER BOXES
4 SOUTH ELEVATION (COLOUR) DWG NUMBER.
A.200
SCALE.
1 : 50
DWG NUMBER. SCALE.
A.200 1 : 100

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title ELEVATIONS Drawing Number TP.301 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / As indicated read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
FINISHES LEGEND
LEGEND A
MATERIAL SELECTED RENDER
PRODUCT -

A. C. F. E.
COLOUR COLORBOND BASALT
FINISH PAINT

LEGEND B
MATERIAL SELECTED RENDER
PRODUCT -
COLOUR LIGHT GREY
FINISH PAINT

LEGEND C
MATERIAL SELECTED ALUMINIUM FRAMED GLAZING
FRAME COLOUR COLORBOND MONUMENT
FRAME FINISH POWDERCOAT
GLAZING CLEAR

LEGEND D
MATERIAL SELECTED TIMBER BATTENS/POSTS
PRODUCT -
COLOUR NATURAL
FINISH -

LEGEND E
MATERIAL SELECTED VERTICAL RENDER
PRODUCT -
COLOUR LIGHT GREY
FINISH PAINT

LEGEND
MATERIAL
FRAME COLOUR
F
SELECTED BALUSTRADE GLAZING
MONUMENT
B. D. G.
FRAME FINISH POWDERCOAT
GLAZING CLEAR

LEGEND G
MATERIAL SELECTED GARAGE DOOR, SHROUDS,
DOWNPIPES, FASCIAS & GUTTERS
COLOUR MONUMENT
FINISH POWDERCOAT

LEGEND H
MATERIAL SELECTED METAL DECK ROOFING
PRODUCT STAND SEAM
COLOUR LIGHT GREY
FINISH -

LEGEND I
MATERIAL SELECTED ENTRY DOOR
PRODUCT -
COLOUR MONUMENT
FINISH POWDERCOAT

LEGEND J
MATERIAL SELECTED TIMBER PALING FENCE
PRODUCT -
-
COLOUR NATURAL
FINISH -

NOTES.
H . I. J.
DOUBLE GLAZING (OR BETTER) TO BE USED TO ALL HABITABLE AREAS

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title FINISHES SCHEDULE Drawing Number TP.302 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 50 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
WSUD NOTES

WATER EFFICIENCY
RAINWATER TANKS
2000L RAINWATER TANKS TO BE PROVIDED TO EACH DWELLING.

CONC.
XWAY
RAINWATER TANKS ARE TO BE CONNECTED TO:

74
• SANITARY FLUSHING SYSTEMS

.82
• IRRIGATION

R
TAPS TO BE PROVIDED TO EACH DWELLING'S POS/FOS.

76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK,

69
85 LOT 2 SOUTHERN ROAD 1230
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W 2975

70.76 S 70.91 S 75.38 H


74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
HW 72.48 H

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


73.16
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
69

69
69

.71
69

69

69

.74

69
69
87° 13' 00" 35.26M
SITE BOUNDARY

.68
1.7M HIGH PALING FENCE

69
PERMEABLE DRIVEWAY & D.01 PATH

CONC.
XWAY
27.02m 2
PERMEABLE AREA

S.P.O.S
2KL
RWT DRIVEWAY & PATHWAYS
.70 1.9 HIGH C'BOND FENCE

94.29m 2
UNTREATED

3 LOT 2 MILTON COURT D.01 BALCONY


DOUBLE STOREY BRICK & REND 6.74m2
UNTREATED

.80
D

.94

.89
RESIDENCE D.03 ROOF D.01 ROOF

69
69

69
1HW 48.40m 2 64.32m 2
69

SHELLEY STREET
74.90 H TREATED TO RWT TREATED TO RWT

.79
74.40 S 2KL

SITE BOUNDARY

.70
69
UNDERGROUND

69
HW
SITE BOUNDARY

RWT

72.00 H
76

71.00 S
.68
R

CONCRETE PATH
75

HW HT 6M
.16

180° 00' 00" 18.29M


74.93 H
E

0° 00' 00" 16.03M

73.96 S

D.02 BALCONY
6.93m2
D D.04 ROOF UNTREATED
72.07 H 98.88m 2 D.02 ROOF

CONC.
XWAY
TREATED TO RWT 65.37m 2
72

TREATED TO RWT
76

.39
.68

3 LOT 3 MILTON COURT

.67
R

.78

69
69
DOUBLE STOREY BRICK & REND
HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
.8
71.97 H

69

69
70.92 S
1W D.02 DRIVEWAY & PATH
74.94 H 2KL RWT 18.23m 2
74.42 S PERMEABLE AREA

2KL

.86

CONC.
.79

XWAY
RWT

.72
69

.79
69

69

69
.53
.64
2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE

.63
SITE BOUNDARY 270° 53' 30" 35.22M

.79
.51

.64

69
69
HT 3M

69

69
69
69

69
75

72
.18

.08
E

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50
R

.73
75

72

.62
69
.00

RL AD
.59

69
S
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW

PO VER
E

72.30 H 72.134 H
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND 12050

RESIDENCE

.70
.77

.73

.60
69
69

69

69
13445

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title CATCHMENT PLAN Drawing Number TP.400 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
CONC.
XWAY
74
.82
R
76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK,

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H
74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
HW 72.48 H

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


73.16
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69
TREE 14

.81

.65
69

69
69

.71
69

1000

69

69

.74

69
00

69
R 24 20 87° 13' 00" 35.26M
R RY
00 Z SIT BOUNDA
ERY GARDEN AREA

0
SR TO BOU NDA
SCREEN PLANTING

00
TPZ

R1
18.14 m²

.68
TO BOU NDARY
SCREEN PLANTING
1.7M HIGH PALING FENCE

69
ACE PERMEABLE
D.03 TANDEM CAR SP

CONC.
XWAY
PAVING
4.9m x 2.6m

3140
2870
S.P.O.S
LINE OF FLOOR ABOVE
3625 4195
.70 1.9 HIGH C'BOND FENCE

LINE OF BALCONY ABOVE


SCREEN PLANTING TO BOUNDARY

1000
LINE OF FLOOR ABOVE

3 LOT 2 MILTON COURT 1805

DOUBLE STOREY BRICK & REND

.80
D

.94

.89
RESIDENCE GARDEN AREA GARDEN AREA

69
69

69
1HW

SITE BOUNDARY
11.69 m² 54.47 m²
69

SHELLEY STREET
74.90 H

.79
74.40 S

.70
LINE OF PORCH

69

69
HW
SITE BOUNDARY

GARDEN AREA
72.00 H
81.90 m²
76

71.00 S

11285
.68

180° 00' 00" 18.29M


R

1190 00

CONCRETE PATH
R 33 21
75

HW 00 R Z HT 6M
.16

TPZ SR
74.93 H
E

0° 00' 00" 16.03M

73.96 S 1205
TREE 1

D
72.07 H

CONC.
XWAY
72
76

.39

LINE OF BALCONY ABOVE


.68

7845
SCREEN PLANTING TO BOUNDARY

3 LOT 3 MILTON COURT

.67
R

.78

69
69
DOUBLE STOREY BRICK & REND D.04 CARPORT
HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
.8
71.97 H

69

69
70.92 S 3450
1W 5690
74.94 H PERMEABLE PAVING
74.42 S GARDEN AREA

2065
2030

2030

D.02 TANDEM CAR SPACE


16.22 m²

.86
4.9m x 2.6m

CONC.
.79

XWAY
4415

.72
69

.79
SCREEN PLANTING TO BOUNDARY

69

69

69
.53
.64
9110 2.0M HIGH PALING FENCE SITE BOUNDARY 270° 53' 30" 35.22M R1

.87
1.9M HIGH PALING FENCE 000

.63
.79
.51

.64

69
69
R2 HT 3M S 800

69

69
69
69

69
75

72

Z RZ
TP
.18

.08
E

TREE 2

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50
R

.73
75

72

.62
69
.00

RL AD
.59

69
S
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW

PO VER
E

72.30 H 72.134 H
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE
GARDEN AREA

.70
.77

.73
Name Area % OF SITE

.60
69
69

69

69
GARDEN AREA 182.41 m² 30.19%

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title GARDEN AREA PLAN Drawing Number TP.500 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
CONC.
XWAY
74
.82
R
76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK,

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H
74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
HW 72.48 H

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


73.16
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
69

69
69

.71
69

69

69

.74

69
69
.68
1.7M HIGH PALING FENCE

69

CONC.
XWAY
EXISTING BUILDING OUTLINE
S.P.O.S
.70 1.9 HIGH C'BOND FENCE

25°
3 LOT 2 MILTON COURT

25°
DOUBLE STOREY BRICK & REND

.80
D

.94

.89
RESIDENCE

69

69

69
1HW
69

SHELLEY STREET

74.90 H

.79
74.40 S

.70
69
25°

69
HW

25°
72.00 H
76

71.00 S
.68


R

CONCRETE PATH
75

HW HT 6M
.16

74.93 H
E

73.96 S


25°
D 5°


72.07 H

CONC.
XWAY
25° 25°
72
76

.39
.68

3 LOT 3 MILTON COURT

.67
R

.78

69
69
25°

DOUBLE STOREY BRICK & REND


HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
.8

71.97 H

69

69
70.92 S
1W
74.94 H

74.42 S

.86

CONC.
.79

XWAY

.72
69

.79
69

69

69
.53
.64
2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE

.63
.79
.51

.64

69
69
HT 3M

69

69
69
69

69
75

72
.18

.08
E

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50
R

.73
75

72

.62
69
.00

RL AD
.59

69
S
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW

PO VER
E

72.30 H 72.134 H
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE

.70
.77

.73

.60
69
69

69

69
LEGEND

EXISTING SHADOW

PROPOSED SHADOW

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title 9AM SHADOWS Drawing Number TP.600 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
CONC.
XWAY
74
.82
R
76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK,

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H
74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
HW 72.48 H

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


73.16
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
69

69
69

.71
69

69

69

.74

69
69
.68
1.7M HIGH PALING FENCE

69

CONC.
XWAY
EXISTING BUILDING OUTLINE
S.P.O.S
.70 1.9 HIGH C'BOND FENCE

25°
3 LOT 2 MILTON COURT

25°
DOUBLE STOREY BRICK & REND

.80
D

.94

.89
RESIDENCE

69

69

69
1HW
69

SHELLEY STREET

74.90 H

.79
74.40 S

.70
69
25°

69
HW

25°
72.00 H
76

71.00 S
.68


R

CONCRETE PATH
75

HW HT 6M
.16

74.93 H
E

73.96 S


25°
D 5°


72.07 H

CONC.
XWAY
25° 25°
72
76

.39
.68

3 LOT 3 MILTON COURT

.67
R

.78

69
69
25°

DOUBLE STOREY BRICK & REND


HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
.8

71.97 H

69

69
70.92 S
1W
74.94 H

74.42 S

.86

CONC.
.79

XWAY

.72
69

.79
69

69

69
.53
.64
2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE

.63
.79
.51

.64

69
69
HT 3M

69

69
69
69

69
75

72
.18

.08
E

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50
R

.73
75

72

.62
69
.00

RL AD
.59

69
S
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW

PO VER
E

72.30 H 72.134 H
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE

.70
.77

.73

.60
69
69

69

69
LEGEND

EXISTING SHADOW

PROPOSED SHADOW

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title 10AM SHADOWS Drawing Number TP.601 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 C Issue in response to council RFI dated 16.07.2024 JULY 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D D Issue in response to Council RFI dated 22.08.2024 AUG 2024 person without the prior written consent of the company.

Drawn by GM/RL
All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
CONC.
XWAY
74
.82
R
76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK,

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H
74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
HW 72.48 H

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


73.16
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
69

69
69

.71
69

69

69

.74

69
69
.68
1.7M HIGH PALING FENCE

69

CONC.
XWAY
EXISTING BUILDING OUTLINE
S.P.O.S
.70 1.9 HIGH C'BOND FENCE

25°
3 LOT 2 MILTON COURT

25°
DOUBLE STOREY BRICK & REND

.80
D

.94

.89
RESIDENCE

69

69

69
1HW
69

SHELLEY STREET

74.90 H

.79
74.40 S

.70
69
25°

69
HW

25°
72.00 H
76

71.00 S
.68


R

CONCRETE PATH
75

HW HT 6M
.16

74.93 H
E

73.96 S


25°
D 5°


72.07 H

CONC.
XWAY
25° 25°
72
76

.39
.68

3 LOT 3 MILTON COURT

.67
R

.78

69
69
25°

DOUBLE STOREY BRICK & REND


HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
.8

71.97 H

69

69
70.92 S
1W
74.94 H

74.42 S

.86

CONC.
.79

XWAY

.72
69

.79
69

69

69
.53
.64
2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE

.63
.79
.51

.64

69
69
HT 3M

69

69
69
69

69
75

72
.18

.08
E

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50
R

.73
75

72

.62
69
.00

RL AD
.59

69
S
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW

PO VER
E

72.30 H 72.134 H
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE

.70
.77

.73

.60
69
69

69

69
LEGEND

EXISTING SHADOW

PROPOSED SHADOW

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title 11AM SHADOWS Drawing Number TP.602 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 C Issue in response to council RFI dated 16.07.2024 JULY 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D D Issue in response to Council RFI dated 22.08.2024 AUG 2024 person without the prior written consent of the company.

Drawn by GM/RL
All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
CONC.
XWAY
74
.82
R
76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK,

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H
74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
HW 72.48 H

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


73.16
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
69

69
69

.71
69

69

69

.74

69
69
.68
1.7M HIGH PALING FENCE

69

CONC.
XWAY
EXISTING BUILDING OUTLINE
S.P.O.S
.70 1.9 HIGH C'BOND FENCE

25°
3 LOT 2 MILTON COURT

25°
DOUBLE STOREY BRICK & REND

.80
D

.94

.89
RESIDENCE

69

69

69
1HW
69

SHELLEY STREET

74.90 H

.79
74.40 S

.70
69
25°

69
HW

25°
72.00 H
76

71.00 S
.68


R

CONCRETE PATH
75

HW HT 6M
.16

74.93 H
E

73.96 S


25°
D 5°


72.07 H

CONC.
XWAY
25° 25°
72
76

.39
.68

3 LOT 3 MILTON COURT

.67
R

.78

69
69
25°

DOUBLE STOREY BRICK & REND


HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
.8

71.97 H

69

69
70.92 S
1W
74.94 H

74.42 S

.86

CONC.
.79

XWAY

.72
69

.79
69

69

69
.53
.64
2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE

.63
.79
.51

.64

69
69
HT 3M

69

69
69
69

69
75

72
.18

.08
E

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50
R

.73
75

72

.62
69
.00

RL AD
.59

69
S
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW

PO VER
E

72.30 H 72.134 H
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE

.70
.77

.73

.60
69
69

69

69
LEGEND

EXISTING SHADOW

PROPOSED SHADOW

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title 12PM SHADOWS Drawing Number TP.603 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
CONC.
XWAY
74
.82
R
76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK,

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H
74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
HW 72.48 H

.25
70.83 S
70.69 S

E
71.66 H
S.P.O.S TOP OF WALL 71.14 S

CONC. KERB & CHANNEL


73.16
S.P.O.S

.94
2.0M HIGH PALING FENCE

.71

.83
.94
S.P.O.S

.88

69

.81

.65
69

69
69

.71
69

69

69

.74

69
69
.68
1.7M HIGH PALING FENCE

69

CONC.
XWAY
EXISTING BUILDING OUTLINE
S.P.O.S
.70 1.9 HIGH C'BOND FENCE

25°
3 LOT 2 MILTON COURT

25°
DOUBLE STOREY BRICK & REND

.80
D

.94

.89
RESIDENCE

69

69

69
1HW
69

SHELLEY STREET

74.90 H

.79
74.40 S

.70
69
25°

69
HW

25°
72.00 H
76

71.00 S
.68


R

CONCRETE PATH
75

HW HT 6M
.16

74.93 H
E

73.96 S


25°
D 5°


72.07 H

CONC.
XWAY
25° 25°
72
76

.39
.68

3 LOT 3 MILTON COURT

.67
R

.78

69
69
25°

DOUBLE STOREY BRICK & REND


HW
2.0M HIGH C'BOND FENCE

RESIDENCE

.81
.8

71.97 H

69

69
70.92 S
1W
74.94 H

74.42 S

.86

CONC.
.79

XWAY

.72
69

.79
69

69

69
.53
.64
2.0M HIGH PALING FENCE

.87
1.9M HIGH PALING FENCE

.63
.79
.51

.64

69
69
HT 3M

69

69
69
69

69
75

72
.18

.08
E

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


69

69
.50
R

.73
75

72

.62
69
.00

RL AD
.59

69
S
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW

PO VER
E

72.30 H 72.134 H
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S
1W
74.99 H
74.53 S
76
.52
R

9 SHELLEY STREET
SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
RESIDENCE
DOUBLE STOREY BRICK & REND
RESIDENCE

.70
.77

.73

.60
69
69

69

69
LEGEND

EXISTING SHADOW

PROPOSED SHADOW

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title 3PM SHADOWS Drawing Number TP.604 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / 1 : 100 read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
LANDSCAPING LEGEND

EXISTING TREE TO BE RETAINED


OR EXISTING STREET TREE

CONC.
XWAY
74
.82
R
76
.02
83 SOUTHERN ROAD

.91
R

.89
69
SINGLE STOREY BRICK 13 SHELLEY STREET

69

.83

.73
RESIDENCE

69
DOUBLE STOREY BRICK, TREE TO BE

69
85 LOT 2 SOUTHERN ROAD
TIMBER & TILE RESIDENCE DEMOLISHED
SINGLE STOREY BRICK RESIDENCE

CONCRETE PATH
HW

VERANDAH
HW
71.91 H 71.91 H 1W
70.76 S 70.91 S 75.38 H
74.81 S TOP OF WALL
HW 76.27
72.48 H HW

72
72.48 H
HW TREE

.25
70.83 S SCREENED D.01, D.02 & D.04 SHARED BIN AREA
70.69 S

E
71.66 H 3 x 120L BINS (GENERAL RUBBISH),

S.P.O.S TOP OF WALL 71.14 S


3 x 240L BINS (RECYCLING),
3 x 240L BINS (FOOD & GARDEN ORGANICS),

CONC. KERB & CHANNEL


73.16 3 x BINS (GLASS). CAPACITY TBC.

S.P.O.S 900mm HIGH ALUMINIUM BATTEN FENCING & WaC (9)

.94
2.0M HIGH PALING FENCE

.71

.83
CONCRETE PAVING TO BIN AREA.

.94
S.P.O.S

.88

69
D.03 BIN AREAS
TREE 14

.81

.65
69

69
69
WaC (9)

.71
69
1 x 120L BINS (GENERAL RUBBISH),

69

69

.74
1 x 240L BINS (RECYCLING),

69
PnFF (1)
00 1 x 240L BINS (FOOD & GARDEN ORGANICS), PnFF (1)

69
R 24 20 1 x BINS (GLASS). CAPACITY TBC. 87° 13' 00" 35.26M
00 R Z SITE BOUNDARY

SITE BOUNDARY
TO BOUNDARY
TPZ SR SCREEN PLANTING
PnFF (1) PnFF (1) RiSp (9)
PnFF (1)

.68
TO BOU NDARY
SCREEN PLANTING
1.7M HIGH PALING FENCE BaiRC (1) BaiRC (1) BaiRC (1) BaiRC (1)

69
RiSp (11)
SHRUBS
PEDESTRIAN VISIBILITY SPLAY
PnFF (1) PnFF (1) BaiRC (1) PERMEABLE THE SPLAYS MUST BE AT LEAST 50% CLEAR OF
PnFF (1)

CONC.
ANY VISUAL OBSTRUCTIONS (STRUCTURES,

XWAY
BaiRC (1) PAVING VEGETATION AND THE LIKE). THE SPLAYS MAY
WaC (9) BaiRC (1) BaiRC (1) RiSp (10) INCLUDE AN ADJACENT ENTRY OR EXIT LANE
WHERE MORE THAN ONE LANE IS PROVIDED,
WaC (11) OR ADJACENT LANDSCAPED AREAS, PROVIDED

180° 00' 00" 18.29M


THE LANDSCAPING IN THESE AREAS IS LESS
THAN 900MM IN HEIGHT.
S.P.O.S BaiRC (1) DRIVEWAY:
BaiRC (1) TO BE FINISHED IN MUTED TONES
GROUNDCOVER

MAIL
GrL (1)

MAIL
MB

MAIL
MAIL
TO SOFTEN APPEARANCE & BLEND
.70 1.9 HIGH C'BOND FENCE

WITH VEGETATION. MB W
W W
W
WaC (3) GrL (1)
MB
PnFF (1) MB

BaiRC (1)
3 LOT 2 MILTON COURT CONCRETE PAVING
BaiRC (1) BaiRC (1)
DOUBLE STOREY BRICK & REND (HARD, IMPERVIOUS)

.80
D

.94
RiSp (8) EuD (1) GrL (1)

.89
RESIDENCE

69
69

69
1HW WaC (6)
RiSp (6)
69

BaiRC (1)

SHELLEY STREET
74.90 H WaC (6)
STORAGE

BaiRC (1)

.79
74.40 S

.70
PERMEABLE CONCRETE PAVING

69
WaC (5)

69
HW
SITE BOUNDARY

BaiRC (1)
72.00 H CacE (1)
76

SCREEN PLANTING TO BOUNDARY

71.00 S
.68

RiSp (5)
GrL (1)
R

GrL (1) WaC (6) 0


0
GRASS (LAWN)

CONCRETE PATH
R 33 21
75

HW 00 R Z HT 6M
.16

WaC (3) BaiRC (1) WaC (7)


TPZ SR
74.93 H GrL (1)
E

0° 00' 00" 16.03M

RiSp (6)
73.96 S
PnFF (1) GrL(1)(1)
BaiRC
BaiRC (1) TREE 1
BaiRC (1) PLANTER BED
D BaiRC (1)
STORAGE

72.07 H PnFF (1) BaiRC (1)

CONC.
EuHa (1)

XWAY
BaiRC (1)
BaiRC (1)
72

EuD (1) WaC (5)


76

.39

WaC (6) EDGING - RECYCLED PLASTIC


.68

3 LOT 3 MILTON COURT GARDEN EDGING TO BE PROVIDED

.67
R

.78
RiSp (6) GrL (1)

69
69
DOUBLE STOREY BRICK & REND BaiRC (1) BETWEEN ALL GARDEN BEDS,
HW
2.0M HIGH C'BOND FENCE

RESIDENCE

5
LAWN AND GRAVEL PATHS AT

.81
PnFF (1)

.8
71.97 H WaC (8)

69

69
BaiRC (1)
70.92 S WaC WaC
(2) (2)
RiSp (7) 100MM DEEP.
1W PEDESTRIAN VISIBILITY SPLAY
BaiRC (1) WaC (4) PERMEABLE PAVING
74.94 H THE SPLAYS MUST BE AT LEAST 50% CLEAR OF
ANY VISUAL OBSTRUCTIONS (STRUCTURES,

74.42 S PnFF (1) BaiRC (1) BaiRC (1)


VEGETATION AND THE LIKE). THE SPLAYS MAY
INCLUDE AN ADJACENT ENTRY OR EXIT LANE
WHERE MORE THAN ONE LANE IS PROVIDED,
BaiRC (1) OR ADJACENT LANDSCAPED AREAS, PROVIDED
PnFF (1)

.86
STORAGE ENCROACHMENT THE LANDSCAPING IN THESE AREAS IS LESS

CONC.
.79

XWAY

.72
WaC (15)

69

.79
SCREEN PLANTING TO BOUNDARY THAN 900MM IN HEIGHT.

69

69

69
.53
.64
2.0M HIGH PALING FENCE R1

.87
1.9M HIGH PALING FENCE SITE BOUNDARY 270° 53' 30" 35.22M 000

.63
.79
.51

.64

69
69
80
R 2 HT 3M

69
0

69
69
69

69
75

72

Z SR
P Z
.18

.08

T
E

TREE 2

.98
71

69
.81
E

S.P.O.S CARPORT
SHED

.83
HT 2M

.75
72

CONC. KERB & CHANNEL


NOTE:

69

69
.50
R

WIDTH OF PLANTING HOLE TO BE EITHER 3

.73
TIMES ROOTBALL D.I.A. IN HIGHLY
75

72

.62
COMPACTED SOILS OR 2 TIMES ROOT BALL

69
.00

RL AD
.59

69
S
D.I.A. MIN. IN ALL OTHER SOIL TYPES
R

INE
WE HE
TOP OF WALL
75

D
.26

72.98 NHW HW NEW TREE TO BE A HEALTHY, WELL

PO VER
E

GROWN SPECIMEN AND WATERED PRIOR


72.30 H 72.134 H TO PLANTING
71.76 S 71.04 S

O
D
71.97 H
1W S.P.O.S
75.02 H HT 5M
74.53 S PLANTING SCHEDULE
1W
74.99 H ABBREV. BOTANICAL NAME COMMON NAME D/E HxW SUPPLY SIZE DENSITY COUNT
74.53 S TREES 50MM WIDE CANVAS TIE IN FIGURE 8 LOOP
76

SECURED TO STAKES WITH GALVANISED


.52

EuD Eucalyptus Euky Dwarf E 4.0-10.0m x 3.0-4.0m 33cm Pots - 2 NAILS


R

leucoxylon 9 SHELLEY STREET


EuHa Eucalyptus Scribbly Gum E 12-15m x 10-15m Min. Height 1.6m, 1 SINGLE STOREY BRICK

CONC.
5 LOT 2 MILTON COURT

XWAY
haemostoma 40L Container RESIDENCE 50 X 50 X 2400MM HARDWOOD STAKES
DOUBLE STOREY BRICK & REND 3
EXTENDED 600MM INTO GROUND OUTSIDE
ROOTBALL
RESIDENCE STRAPPY LEAFED
WaC Dianella Tasmanica Tasman Flax Lily E 15-50 cm x 15cm 140mm Pots - 116 75MM ORGANIC MULCH TO FORM SHALLOW
MOUNDED BERM AWAY FROM BASE OF
NEW GROUNDCOVERS TO BE HEALTHY,
116 TRUNK

.70
.77
WELL-GROWN SPECIMENS AND WELLWATERED

.73

.60
69
69

69
SHRUBS PRIOR TO PLANTING NEW SHRUB TO BE A HEALTHY, WELL BACKFILL EXCAVATED FROM SITE

69
GROWN SPECIMEN AND WATERED PRIOR
CacE Callistemon citrinus Endeavour E 2 -3 m x 1.5 - 2 m 20cm 1 TO PLANTING
ROOT BALL
DIAGONAL PLANTING IN ROWS TO ENSURE A NEAT
'Endeavour' Bottlebrush AND CONSISTENT LAYOUT IS ACHIEVED WITHIN MOUNDED BERM
GrL Grevillea Lanigera Mt Tamboritha E 1.0 -3.0 m x 2.0 - 3.0m 140mm Pots - 7 EACH GARDEN-BED 75MM ORGANIC MULCH EXISTING SUB-GRADE

PnFF Protea nerilifolia Protea Frosted Fire E 1.5 m x 1.5m 20cm Pot - 14 ROOT BALL
BREAK UP SIDES AND BASE OF HOLE
22 TREE STAKES EXTENDED 200MM MIN. INTO
UNDISTURBED SOIL
200MM NEW TOPSOIL TO BE CULTIVATED INTO
GROUND COVER EXISTING SUB-GRADE @ 275MM MIN. DEPTH

BaiRC Banksia integriflora Rollercoaster E 0.2m x 1-3m 140mm Pots 30 EXISTING SUB-GRADE
DWG REF. VIEW NAME.
'Roller Coaster' Banksia DWG REF. VIEW NAME. DWG REF. VIEW NAME.
RiSp Rhaphiolepis indica Indian Hawthorn E 0.8 x 1m 140mm Pots - 76 3 Groundcover Planting 2 Shrub Planting 1 Tree Planting Guide
'Spring Pearl' DWG NUMBER. SCALE.
DWG NUMBER. SCALE. DWG NUMBER. SCALE.
106 1 : 20
1 : 20 1 : 20

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title LANDSCAPE PLAN Drawing Number TP.700 A Issue to Lodge 19/03/2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D C Issue in response to council RFI dated 16.07.2024 JULY 2024 person without the prior written consent of the company.

Drawn by KE D Issue in response to Council RFI dated 22.08.2024 AUG 2024


All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / As indicated read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
LEGEND
INGRESS
4900 4900
300 300

EGRESS

300

300
3000

3000
ACE ACE
D.03 TANDEM CAR SP D.03 TANDEM CAR SP
4.9m x 2.6m 4.9m x 2.6 m

2600

2600
VEHICLE B85:

3205

3205
85th PERCENTILE (5.75M RADIUS)

0
400

400

R 575
R
D.03 POS D.03 POS

R
R

57
57
57

50
42.54 m² 50

50
42.54 m²
D.03 FOS D.03 FOS
12.46 m² D.01 FOS 12.46 m² D.01 FOS
31.76 m² 31.76 m²

D.03 GF D.01 GARAGE D.03 GF D.01 GARAGE


45.58 m² D.01 GF 45.58 m² D.01 GF
22.20 m² 22.20 m²
27.53 m² 27.53 m²

D.04 FOS D.04 FOS


D.04 GF D.04 GF
3.63 m² 3.63 m²
60.84 m² 60.84 m²
D.02 FOS D.02 FOS

D.04 POS 26.96 m² D.04 POS 26.96 m²


D.02 GF D.02 GF
38.28 m² 38.28 m²
49.91 m² 49.91 m²

D.04 CARPORT D.04 CARPORT


6000

6000
33.00 m² 33.00 m²
500 4900 500 4900
D.02 GARAGE D.02 GARAGE
21.00 m² 21.00 m²

2600

2600
3000

3000
D.02 POS D.02 POS
5500 D.02 TANDEM CAR SPACE 5500 D.02 TANDEM CAR SPACE
16.41 m² 16.41 m²
4.9m x 2.6m 4.9m x 2.6m

300

300
DWG REF. VIEW NAME. DWG REF. VIEW NAME.
1 D.01 INGRESS & EGRESS 2 D.03 INGRESS & EGRESS
DWG NUMBER. SCALE. DWG NUMBER. SCALE.
TP.300 1 : 100 TP.300 1 : 100

4900 4900
300 300
300

300
3000

3000
AC E ACE
D.03 TANDEM CAR SP D.03 TANDEM CAR SP
4.9m x 2.6m 4.9m x 2.6m
2600

2600
3205

3205
400

400
D.03 POS 750 D.03 POS
R5
R
57

42.54 m² 42.54 m²
50

R5
750
D.03 FOS D.03 FOS
12.46 m² D.01 FOS 12.46 m² D.01 FOS
31.76 m² 31.76 m²

D.03 GF D.01 GARAGE D.03 GF D.01 GARAGE


R5
45.58 m² D.01 GF 45.58 m² 750 D.01 GF
22.20 m² 22.20 m²
27.53 m² 27.53 m²

D.04 FOS
D.04 FOS 3.63 m²
D.04 GF D.04 GF
3.63 m²
60.84 m² 60.84 m²
D.02 FOS D.02 FOS

D.04 POS 26.96 m² D.04 POS 26.96 m²


D.02 GF D.02 GF
38.28 m² 38.28 m²
49.91 m² 49.91 m²

D.04 CARPORT D.04 CARPORT


6000

6000
33.00 m² 33.00 m²
500 4900 500 4900
D.02 GARAGE D.02 GARAGE
21.00 m² 21.00 m²
2600

2600
3000

3000
D.02 POS D.02 POS
5500 D.02 TANDEM CAR SPACE 5500 D.02 TANDEM CAR SPACE
16.41 m² 16.41 m²
4.9m x 2.6m 4.9m x 2.6m
300

300
DWG REF. VIEW NAME. DWG REF. VIEW NAME.
3 D.04 INGRESS & EGRESS 4 D.04 INGRESS & EGRESS
DWG NUMBER. SCALE. DWG NUMBER. SCALE.
TP.300 1 : 100 TP.300 1 : 100

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title SWEPT PATHS Drawing Number TP.900 B Issue in Response to Council RFI dated 21.05.2024 JUNE 2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 C Issue in response to council RFI dated 16.07.2024 JULY 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D D Issue in response to Council RFI dated 22.08.2024 AUG 2024 person without the prior written consent of the company.

Drawn by GM/RL
All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / As indicated read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.
ESD LEGEND
SCREENED D.01, D.02 & D.04 SHARED BIN AREA
3 x 120L BINS (GENERAL RUBBISH),
3 x 240L BINS (RECYCLING),
3 x 240L BINS (FOOD & GARDEN ORGANICS),
AUTOMATIC EXTERNAL LIGHTS (SENSOR)
3 x BINS (GLASS). CAPACITY TBC.
900mm HIGH ALUMINIUM BATTEN FENCING &
CONCRETE PAVING TO BIN AREA. AC AIR CONDITIONING CONDENSER
D.03 BIN AREAS
1 x 120L BINS (GENERAL RUBBISH),
1 x 240L BINS (RECYCLING),
1 x 240L BINS (FOOD & GARDEN ORGANICS),
HWU INSTANTANEOUS HOT WATER UNIT
1 x BINS (GLASS). CAPACITY TBC.

DOWNLIGHTS (10-13 WATTS) TO ACHIEVE A 4 W/m 2 EFFICIENCY

BAR LIGHT

D.03 TANDEM CAR SPACE EXTERNAL WALL LIGHTS


4.9m x 2.6m

1.8M FENCE
& GATE
DEPTH OF EXTERNAL SHADING DEVICES 1:80 MAX. SLOPE
TO BE AT LEAST 25% OF THE DISTANCE FSD DEPTH RWT RAINWATER TANK IN ACCORDANCE WITH WSUD PLAN
FSD ABOVE FROM THE BOTTOM OF GLAZING TO
450mm PROJECTION
MONA LISA SHADING DEVICE. DG DOUBLE GLAZING
WINDOW H: 1800mm
2KL BIKE RACK

AC
EV
RWT FSD ABOVE TAP
CHARGER 450mm PROJECTION mona lisa BIKE RACK - 'MONA LISA' WALL MOUNTED
WINDOW H: 1800mm VB bike rack
TAP DG
U-VALUE: 3.2 WC 65 65
SHGC: 0.49
HWU SHR
BATTEN GAP TAP
SLIDING DOOR H: 2700mm

SK DG
WM/DM FW ENS WIR

WINDOW HEIGHT
DG U-VALUE: 3.2

450mm PROJECTION
675mm PROJECTION

LDRY

WINDOW H: 1800mm
U-VALUE: 3.2 SHGC: 0.49 DP DP
DOWNPIPE
SHGC: 0.49

ASD ABOVE:
ASD ABOVE

EV CHARGER
DG CROSS-FLOW VENTILATION
U-VALUE: 3.2 LIVING, KITCHEN & DINING BED 01
SHGC: 0.49 DG ASD MONA LISA DEPTH OF EXTERNAL SHADING DEVICES
BIKE RACK FLOOR-WASTE
U-VALUE: 3.2 450mm PROJECTION TO BE AT LEAST 25% OF THE DISTANCE
6m3 STORAGE

SHGC: 0.49 WINDOW H: 180mm FW

D.01 FROM THE BOTTOM OF GLAZING TO


D.03
2KL
CL

NO FRONT FENCE PROPOSED


SK UNDERGROUND SHADING DEVICE. OUTDOOR CLOTHES LINE
300mm PROJECTION
ASD ABOVE

WINDOW H: 600mm

RWT NATHERS RATING: 7.2 STARS


RH NATHERS RATING: 7.9 STARS

D.01 PORCH
D.03 PORCH
OV DW S MOTION DETECTORS
6m3 STORAGE
ECT LDRY UNDER STAIRS DG
ELECTRIC VEHICLE CHARGER.
DG F/FREZ PDR U-VALUE: 3.2

CLOTHESLINE U-VALUE: 3.2 P SHGC: 0.49 A MIN. CAPACITY OF LEVEL 2 (MODE 3) 7kW 32 Amp EV CAR
SHGC: 0.49 OHC HWU CHARGING STATION
1.8M FENCE RH HWU
CLOTHESLINE
ECT P LDRY WC
DG
F/FREZ ENS

D.04 PORCH
SK U-VALUE: 3.2
300mm PROJECTION

DG

450mm PROJECTION
SHGC: 0.49

WINDOW H: 1800mm
WINDOW H: 600mm

OV U-VALUE: 3.2

BESS INITIATIVES
DW SHGC: 0.49 BED 01
D.04
ASD ABOVE

ASD ABOVE:
VB FW

ROBE
DG

300mm PROJECTION
VB

WINDOW H: 600mm
U-VALUE: 3.2 SHR
6m3 STORAGE

SHGC: 0.49 NATHERS RATING: 7.4 STARS


LDRY

ASD ABOVE

LINEN
BED 02 MANAGEMENT
WM/
SK DM

-
LIVING, KITCHEN & DINING
D.02
HWU
BATH

D.02 PORCH
DG
SLIDING DOOR H: 2700mm

U-VALUE: 3.2
SHGC: 0.49
ROBE NATHERS RATING: 7.3 STARS
675mm PROJECTION

CLOTHESLINE
NOMINATED
11.2m 2 BEDROOM EV CHARGER WATER EFFICIENCY
D.04 CARPORT
ASD ABOVE

ENS
FW
MONA LISA
RAINWATER TANKS
DG
VB WC
U-VALUE: 3.2 BIKE RACK
SHGC: 0.49 BED 01 SHR 2000L RAINWATER TANKS TO BE PROVIDED TO EACH DWELLING.
TAP
ROBE

AC TAP
2KL RWT FFL RAINWATER TANKS ARE TO BE CONNECTED TO:
DG
• SANITARY FLUSHING SYSTEMS
450mm PROJECTION

MONA LISA
ASD ABOVE

WINDOW H: 1800mm

U-VALUE: 3.2
SHGC: 0.49 BIKE RACK • IRRIGATION
D.02 TANDEM CAR SPACE
2KL
6m3 STORAGE 4.9m x 2.6m

AC
EV CHARGER RWT REFER TO WSUD FOR FURTHER INFORMATION.

WATER FIXTURES, FITTINGS & CONNECTIONS


SHOWERHEADS 3 STAR WELS (>= 7.5 BUT <=9.0)
DWG REF. VIEW NAME. DWG REF. VIEW NAME.
KITCHEN TAPS >= 5.0 STAR WELS RATING
1 ESD PLAN - GROUND FLOOR 3 TYPICAL SECTION DETAIL - FIXED SHADING DEVICES
DWG NUMBER. SCALE. DWG NUMBER. SCALE. BATHROOM TAPS >= 5.0 STAR WELS RATING
TP.300 1 : 100 1 : 20 WC >= 3.0 STAR WELS RATING

DISHWASHERS >= 4.0 STAR WELS RATING

ENERGY EFFICIENCY
THERMAL PERFORMANCE
ALL DWELLINGS TO ACHIEVE AN AVERAGE MINIMUM NATHERS RATING OF 6.5 STARS

ENERGY USAGE
HEATING SYSTEM REVERSE CYCLE SPACE (MIN. 4-STAR)

COOLING SYSTEM REFRIGERATIVE SPACE (MIN. 4-STAR)

HOT WATER SYSTEM ELECTRIC INSTANTANEOUS


DEPTH OF EXTERNAL SHADING DEVICES FSD ABOVE
TO BE AT LEAST 25% OF THE DISTANCE 450mm PROJECTION CLOTHES DRYING OUTDOOR CLOTHES LINES
WINDOW H: 600mm
FROM THE BOTTOM OF GLAZING TO
450mm PROJECTION
WINDOW H: 1800mm

SHADING DEVICE. EXTERNAL LIGHTING LED WITH MOTION DETECTORS/TIMERS


ASD ABOVE

DG
DG
FSD U-VALUE: 3.2
U-VALUE: 3.2
ILLUMINATION LED LIGHTING

1000mm PROJECTION
EAVES ABOVE
SHGC: 0.49

SLIDING DOOR H: 2700mm


250mm SHROUD PROJECTION
WINDOW H: 600mm
SHGC: 0.49
ADJUSTABLE SHADING DEVICE TO EAST & WEST ELEVATIONS
VB VB LIVING, KITCHEN & DINING FIRST FLOOR ASD'S TO BE OPERABLE FROM WITHIN THE DWELLING.
WC
WC DG
DG
FW FW U-VALUE: 3.2
BATH STORMWATER MANAGEMENT
FW U-VALUE: 3.2
ENSUITE SHR SHGC: 0.49
SHGC: 0.49
SHR
SHR
250mm SHROUD PROJECTION

REFER TO WSUD.
ROBE

ROBE WC
BATH BED 02 DG
U-VALUE: 3.2
WINDOW H: 600mm

VB

D.01
DG SHGC: 0.49
U-VALUE: 3.2
SHGC: 0.49
INDOOR ENVIRONMENT QUALITY
D.03
DG DW
U-VALUE: 3.2 NATHERS RATING: 7.2 STARS DOUBLE GLAZING APPLICABLE TO ALL HABITABLE ROOM WINDOWS
BED 02
FSD

SHGC: 0.49 RCL


300mm PROJECTION

BED 01
WINDOW H: 600mm

NATHERS RATING: 7.9 STARS


ROBE
300mm PROJECTION
WINDOW H: 600mm

ASD ABOVE

OV TRANSPORT
ASD ABOVE

SK F/FREZ
AC

DG ECT P
U-VALUE: 3.2
SHGC: 0.49 RH BICYCLE PARKING TO BE PROVIDED WITHIN THE GARAGES / CARPORTS
RH P F/FREZ
ROBE OHC
DG
U-VALUE: 3.2
DG
U-VALUE: 3.2
FSD
250mm SHROUD PROJECTION SK
ECT URBAN ECOLOGY
SHGC: 0.49 SHGC: 0.49 WINDOW H: 600mm
DG OV
DG
VEGETATION MIN. 30% OF THE SITE IS TO BE COVERED IN VEGETATED AREA
D.04
U-VALUE: 3.2
DG SHGC: 0.49 U-VALUE: 3.2
SHGC: 0.49
BED 02 U-VALUE: 3.2
TAPS IN COURTYARD TAPS TO BE PROVIDED TO EACH DWELLING'S POS/FOS
300mm PROJECTION
WINDOW H: 600mm

SHGC: 0.49
NATHERS RATING: 7.4 STARS
250mm SHROUD PROJECTION

DG DW
ASD ABOVE

U-VALUE: 3.2
300mm PROJECTION

VB
BED 03
WINDOW H: 600mm

SHGC: 0.49
LIVING, KITCHEN & DINING
WINDOW H: 600mm

BED 03
ASD ABOVE

BATH BED 04
ROBE
ROBE

WC
FSD

ASD ABOVE:
SHR 675mm PROJECTION
SLIDING DOOR H: 2700mm
FW
ENSUITE FW
BATH
D.02
DG
WC FW
SHR
VB U-VALUE: 3.2
SHGC: 0.49
ROBE WC VB
SHR NATHERS RATING: 7.3 STARS

DG
U-VALUE: 3.2
SHGC: 0.49

DWG REF. VIEW NAME.


2 ESD PLAN - FIRST FLOOR
DWG NUMBER. SCALE.
TP.300 1 : 100

[email protected] Project Address 11 SHELLEY ST, HEIDELBERG HEIGHTS Project Number 231860 M3 Design (VIC) Pty. Ltd. is the owner of the copyright subsisting in
Rev Description Date
these drawings, plans, designs and specifications. They must not
Unit 2, 1 Bik Lane, Fitzroy North 3068 Drawing Title ESD PLANS Drawing Number TP.901 C Issue in response to council RFI dated 16.07.2024 JULY 2024 be used, reproduced or copied, in whole or in part, nor may the
Drawing Issue TOWN PLANNING Issue Date JULY 2024 D Issue in response to Council RFI dated 22.08.2024 AUG 2024 information, ideas and concepts therein contained (which are
confidential to M3 Design (VIC) Pty. Ltd)) be disclosed to any
Client - Revision Issue D person without the prior written consent of the company.

Drawn by GM/RL
All dimensions must be verified on site prior to commencement of
Checked by GM work or establishment of any shop drawings. Figured dimensions
must take precedence over scaled dimensions. All scaled
Scale A3 / dimensions must be verified on site. These drawings are to be
A1 / As indicated read in conjunction with all specifications, schedules, all other
consultants documentation Town Planning endorsed plans and
Planning Permit.