Hybrid Inverter

Technical Data
SUN-5K SUN-6K SUN-7.6K SUN-8K SUN-10K SUN-12K
Model
-SG02LP1-EU -SG02LP1-EU -SG02LP1-EU -SG02LP1-EU -SG02LP1-EU -SG02LP1-EU
U

SUN-5/6/7.6/8K-SG02LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion

SUN-10/12K-SG02LP1-EU
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 120 135 190 190 220 250
Max. Discharging Current (A) 120 135 190 190 220 250
External Temperature Sensor Yes
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 6500 7800 9880 10400 13000 15600
Rated PV Input Voltage (V) 370 (125-500)
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Full Load DC Voltage Range (V) 300-425 200-425
PV Input Current (A) 13+13 26+13 26+26 26+26 26+26+26 26+26+26
Max. PV ISC(A) 22+22 44+22 44+44 44+44 44+44+44 44+44+44
No.of MPP Trackers 2 3
No.of Strings per MPP Tracker 1+1 2+1 2+2 2+2 2+2+2 2+2+2
AC Output Data
Rated AC Output Active Power (W) 5000 6000 7600 8000 10000 12000
Max AC Output Active Power (W) 5500 6600 8360 8800 11000 13200
AC Output Rated Current (A) 22.8/21.8 27.3/26.1 34.6/33.1 36.4/34.8 45.5/43.5 54.6/52.2
Max. AC Output Current (A) 25/24 30/28.7 38/36.4 40/38.3 50/47.9 60/57.4
Max. Continuous AC Passthrough (A) 35 40 50 50 60 60
Peak Power (off grid) 2 time of rated power, 10 S
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Power Factor 1
Output Frequency and Voltage 50 / 60Hz; L/N/PE 220/230Vac
Grid Type Split Phase; 2/3 phase; Single Phase
Total Harmonics Current Distortion (THDi) <3% (of nominal power)
DC Current Injection <0.5% In
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency 99.90%
Protection
Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Integrated Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge Protection
Over Voltage Category DC Type II/AC Type III
Certifications and Standards

Grid Regulation VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1,


G98, G99, C10-11, UNE217002, NBR16149/NBR16150
Colorful touch LCD, IP65 protection degree
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range ( ) -40 to +60℃, >45℃ Derating
DC AC Normal Alarm

AC couple to retrofit existing solar system Cooling Smart Cooling


Noise (dB) ≤30 dB
Communication with BMS RS485; CAN
16 Max. 16 pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel Weight (kg) -
Cabinet Size (WxHxD mm) 420×670×233 (Excluding Connectors and Brackets)
Protection Degree IP65
250 Max. charging/discharging current of 250A Installation Style Wall-mounted
Warranty 5 Years (10 Years Optional)

6 6 time periods for battery charging/discharging

Support storing energy from diesel generator