Fokker 50/60 AMM 0050 Printed on: Jun 24/10 20:15
Cust: Peru Navy Issue Date: Sep 01/09
TASK 21-00-00-040-822-A - Cool Fan INOP Light - Deactivation (Refer to MMEL 21-26-4)
EFFECTIVITY: 001999
NOTE: Do this procedure when the COOL FAN INOP indication does not operate.
1.. Materials
Placard 1
2.. Special Tools and Equipment
Not applicable
3.. Standard Tools and Equipment
Not applicable
4.. Consumable Materials
Not applicable
5.. Expendable Parts
Not applicable
6.. Referenced Procedures
24-00-00-861-812 Pageblock 201
7.. Procedure
SUBTASK 21-00-00-001-042-A00
A. Make sure electrical power is available (Refer to Task 24-00-00-861-812 for more data) .
SUBTASK 21-00-00-001-052-A01
B. Make sure the circuit breaker(s) are closed:
FLOW SENSOR COOLING P1 CB1824A
INSTRUMENT COOLING P1 CB1804A
AVIONICS RACK COOLING P2 CB0180A
SUBTASK 21-00-00-001-062-A02
C. (Refer to Fig. 21-00-00-990-032-A01)
Do a check of the instrument cooling fans for correct operation
(1.) On the Maintenance and Test Panel (MTP), make sure the INSTR FAN magnetic indicator shows black (no fault).
(2.) On the MTP, make sure the AVIONICS FAN magnetic indicator shows black (no fault).
SUBTASK 21-00-00-001-072-A00
D. Remove the electrical power (Refer to Task 24-00-00-861-812 for more data) .
SUBTASK 21-00-00-001-082-A00
E. Install the placard on the avionics switching panel in the flight compartment
Page 1 of 2
Fokker 50/60 AMM 0050 Printed on: Jun 24/10 20:15
Cust: Peru Navy Issue Date: Sep 01/09
TASK 21-00-00-040-822-A - Cool Fan INOP Light - Deactivation (Refer to MMEL 21-26-4)
EFFECTIVITY: 001999
Component Information
Figure 21-00-00-990-032-A01
Page 2 of 2