Ex. Steam Rankine cycle ทำงานความดัน 30 bar และ 0.
7 bar สมมติเป็น standard cycle จงห
7 bar สมมติเป็น standard cycle จงหาประสิทธิภาพวัฏจักร
water
R2545fa(dry)
Parameter Value Units R2545fa(dry)
Pump efficiency 1 cond.1
Cp 1.23 kJ/kg-C
Q_Evaporator 244 kW
m_dot_evap 1.00 kg/s
W_Turbine 43.45 kW
Q_Condensor 219 kW
m_dot_cond 1.00 kg/s
W_Pump 0.71 kW
Thermal efficiency 9.39 %
Parameter Value Units R2545fa(dry)
Pump efficiency 1.00 cond.2
Cp 1.15 kJ/kg-C
Q_Evaporator 238.30 kW
m_dot_evap 1.00 kg/s
W_Turbine 34.89 kW
Q_Condensor 215.60 kW
m_dot_cond 1.00 kg/s
W_Pump 0.73 kW
Thermal efficiency 7.69 %
Parameter Value Units R2545fa(dry)
Pump efficiency 1 cond.3
Cp 1.24 kJ/kg-C
Q_Evaporator 228.8 kW
m_dot_evap 1.62 kg/s
W_Turbine 36.97 kW
Q_Condensor 210.9 kW
m_dot_cond 1.12 kg/s
W_Pump 0.77 kW
Thermal efficiency 8.41 %
Parameter Value Units water(wet)
Pump efficiency 1.00 example
Cp 4.46 kJ/kg-C
Q_Evaporator 238.30 kW
m_dot_evap 0.13 kg/s
W_Turbine 57.22 kW
Q_Condensor 215.60 kW
m_dot_cond 0.09 kg/s
W_Pump 0.29 kW
Thermal efficiency 12.60 %
Parameter Value Units R2545fa(dry)
Pump efficiency 1 cond.1
Cp 1.23 kJ/kg-C
Q_Evaporator 244 kW
m_dot_evap 1.00 kg/s
W_Turbine 43.45 kW
Q_Condensor 219 kW
m_dot_cond 1.00 kg/s
W_Pump 0.71 kW
Thermal efficiency 9.39 %
R2545fa(dry)
cond.1
R123(dry)
cond.1
R2545fa(dry)
cond.2
R123(dry)
cond.2
R2545fa(dry)
cond.3
R123(dry)
cond.3
state P(kPa) T h s Ja FOM
1 70 89.93173 376.7522 1.192074 1.15 0.472113
2 3000 233.8531 1008.345 1.192074
3 3000 233.8531 1008.345 2.645549
4 70 89.93173 376.7522
Parameter Value Units
Cp_water 1.15 kJ/kg-C
Pump efficiency
Mass flow rate
W_Pump
Q_Evaporator
W_Turbine
Q_Condensor
Thermal efficiency
state P(kPa) T h s Cp Ja
1 1097.1 93.7 329.96 1.4046 1.5521 4.776104
2 1097.1 116 498.09 1.8607 1.1968
3 227.4 71.546 465.81 1.8607 0.99691
4 227.38 37.1 248.64 1.1664 1.3499
Parameter Value Units
Pump efficiency 1
Cp 1.15 kJ/kg-C
Q_Evaporator 244 kW
m_dot_evap 1.33 kg/s
W_Turbine 288.84 kW
Q_Condensor 219 kW
m_dot_cond 1 kg/s
W_Pump 168.13 kW
Thermal efficiency 0.26
T P(kPa) De h s Cp
1 93.7 1097.1 1118.9 329.96 1.4046 1.5521
2 116 1097.1 54.458 498.09 1.8607 1.1968
3 71.546 227.4 11.193 465.81 1.8607 0.99691
4 37.1 227.38 1305 248.64 1.1664 1.3499
5 28 165.47 1330.4 236.44 1.1267 1.3287
6
T P(kPa) De h s Cp
1 40.147 609.6 1297.7 252.85 1.179 1.3557
2 70 609.6 33.82 455 1.7736 1.1474
3 70 609.6 1204.4 294.59 1.3062 1.4466
4 45.062 250.46 13.797 438.82 1.7736 1.0053
5 40 250.46 1296.7 252.57 1.179 1.357
6
T P(kPa) De h s Cp
1 28.336 1097.1 1332.5 237.15 1.1267 1.3261
2 93.72 1097.1 1118.8 329.99 1.4047 1.5522
3 93.72 1097.1 62.291 470.51 1.7877 1.3006
4 116 1097.1 54.458 498.09 1.8607 1.1968
5 37.1 53.165 2.8125 437.23 1.8607 0.9044
6 28 165.47 9.4963 424.97 1.7527 0.9652
7 28 165.47 1330.4 236.44 1.1267 1.3287
T P(kPa) De h s Cp
1 28.344 1120 1332.5 237.17 1.1267 1.326
2 94.619 1120 1115.3 331.38 1.4084 1.5573
3 94.619 1120 63.7 471.06 1.7883 1.308
4 107.8 1120 58.44 487.71 1.8327 1.229
5 37 80.396 4.2955 436.33 1.8327 0.91668
6 28 165.47 9.4963 424.97 1.7527 0.9652
7 28 165.47 1330.4 236.44 1.1267 1.3287
T P(kPa) De h s Cp
1 28.327 1074 1332.4 237.13 1.1267 1.3261
2 92.798 1074 1122.5 328.57 1.4009 1.5471
3 92.798 1074 60.877 469.95 1.7872 1.2932
4 97 1074 59.126 475.31 1.8018 1.2629
5 37 125.02 6.7903 434.95 1.8018 0.93881
6 28 165.47 9.4963 424.97 1.7527 0.9652
7 28 165.47 1330.4 236.44 1.1267 1.3287
T P(kPa) De h s Cp
1 90.116 3000 966.55 379.79 1.1921 4.1989
2 233.85 3000 821.9 1008.3 2.6455 4.7186
3 233.85 3000 15.001 2803.2 6.1856 3.6119
4 256 3000 13.889 2874.7 6.3238 2.9717
5 89.932 70 0.51801 2240 6.3238 Undefined
6 89.932 70 0.42287 2659.4 7.479 2.0427
7 89.932 70 965.34 376.75 1.1921 4.2052
T P(kPa) De h s Cp
1 28.336 1097.1 1332.5 237.15 1.1267 1.3261
2 93.72 1097.1 1118.8 329.99 1.4047 1.5522
3 93.72 1097.1 62.291 470.51 1.7877 1.3006
4 116 1097.1 54.458 498.09 1.8607 1.1968
5 37.1 53.165 2.8125 437.23 1.8607 0.9044
6 28 165.47 9.4963 424.97 1.7527 0.9652
7 28 165.47 1330.4 236.44 1.1267 1.3287
T P(kPa) De h s Cp
1 40.218 789.31 1298.2 252.99 1.179 1.355
2 80 789.31 1170.1 309.24 1.3478 1.4856
3 80 789.31 44.013 461.75 1.7797 1.2042
4 85 789.31 42.713 467.71 1.7964 1.181
5 40 250.46 1292.8 252.58 1.179 Undefined
6 40 250.46 14.124 433.71 1.7574 1.0114
7 40 250.46 1296.7 252.57 1.179 1.357
T P(kPa) De h s Cp
1 40.124 489.09 1425.6 240.82 1.1383 1.0377
2 80 489.09 1311.2 283.35 1.266 1.0996
3 80 489.09 29.188 428.89 1.6781 0.8162
4 95 489.09 27.379 441.11 1.712 0.81449
5 40 70.929 4.276 407.51 1.712 0.70387
6 40 154.47 9.6295 405.54 1.6651 0.72425
7 40 154.47 1424.8 240.59 1.1383 1.0385
T P(kPa) De h s Cp
1 32.798 1006.1 1319.9 243.06 1.1464 1.3364
2 90 1006.1 1133.3 324.28 1.3893 1.5322
3 90 1006.1 56.763 468.2 1.7856 1.2716
4 95 1006.1 54.904 474.48 1.8028 1.2396
5 32.5 101.9 5.5825 431.51 1.8028 0.92385
6 32.5 194.17 11.063 428.26 1.7543 0.98214
7 32.5 194.17 1317.9 242.45 1.1464 1.339
T P(kPa) De h s Cp
1 40.124 489.09 1425.6 240.82 1.1383 1.0377
2 90 624.23 1279.9 294.45 1.2967 1.1197
3 90 624.23 37.213 434.43 1.6822 0.84502
4 95 624.23 36.345 438.64 1.6937 0.84186
5 32.501 119.7 7.9526 392.89 1.637 Undefined
6 32.5 119.7 7.5696 401.03 1.6636 0.70953
7 32.5 119.7 1444.5 232.83 1.1133 1.0289
T P(kPa) De h s Cp
1 25.331 1129.8 1340.7 233.18 1.1134 1.3195
2 95 1129.8 1113.7 331.97 1.41 1.5595
3 95 1129.8 64.306 471.29 1.7885 1.3111
4 100 1129.8 62.066 477.75 1.8059 1.2731
5 25 70.467 3.9223 425.76 1.8059 0.89968
6 25 148.25 8.5531 422.78 1.7518 0.95414
7 25 148.25 1338.5 232.46 1.1134 1.3221
T P(kPa) De h s Cp
1 25.211 701.42 1465.1 225.55 1.0879 1.0185
2 95 701.42 1263.6 300.08 1.312 1.131
3 95 701.42 41.863 437.13 1.6842 0.86088
4 100 701.42 40.853 441.42 1.6958 0.85651
5 25 52.102 3.2881 397.56 1.6958 0.68413
6 25 91.358 5.8716 396.51 1.6627 0.69532
7 25 91.358 1463.9 225.14 1.0879 1.0196
Tcond eff
40 14.6956
FOM Tcond efficiency
0.469721144 28 7.702734
Ja FOM Tcond efficiency [%]
0.50 0.39 28 13.15
Ja FOM Tcond efficiency
Subcooled 5.24330044843 0.676972 28 -5.8521664755
Superheated
Superheated
0
0
Ja FOM Tcond efficiency
Subcooled 0.2341873948 0.54 40 8.412620414
1
0
Superheated
0
Ja FOM Tcond efficiency [%]
Subcooled 0.79 0.31 28 17.94
0
hfg
1 Tevap
Superheated
Superheated Tcond
1
0
Ja FOM Tcond efficiency [%]
Subcooled 6.04 0.41 28 11.79
0
hfg
1 Tevap
Superheated
Superheated Tcond
1
0
Ja FOM Tcond efficiency [%]
Subcooled 16.17 0.49 28 6.45
0
hfg
hfg
1 Tevap
Superheated
Superheated Tcond
1
0
Ja FOM Tcond efficiency
Subcooled 0.36 0.42 40 15.26
0
hfg
1 Tevap
Superheated
0.81625 Tcond
1
0
Ja FOM COP[H] COP[L]
Subcooled 0.79 -0.29 85.09807158
0
hfg
1 Tevap
Superheated Tcond efficiency [%]
Superheated Tcond 28 57.09
1
0
Ja FOM Tcond efficiency [%]
Subcooled 0.37 0.50 40 10.98
0
hfg
1 Tevap
Superheated
0.00003362 Tcond
1
0
Ja FOM Tcond efficiency [%]
Subcooled 0.34 0.45 40 13.55
0
hfg
1 Tevap
Superheated
Superheated Tcond
1
0
Ja FOM Tcond efficiency [%]
Subcooled 0.55 0.40 32.5 14.33
0
hfg
1 Tevap
Superheated
Superheated Tcond
1
0
Ja FOM Tcond efficiency [%]
Subcooled 0.41 0.39 32.5 15.03
0
hfg
1 Tevap
Superheated
0.95161 Tcond
1
0
Ja FOM Tcond efficiency [%]
Subcooled 0.68 0.32 25 16.36
0
hfg
1 Tevap
Superheated
Superheated Tcond
1
0
Ja FOM Tcond efficiency [%]
Subcooled 0.50 0.31 25 17.02
0
hfg
1 Tevap
Superheated
Superheated Tcond
1
0
efficiency of expander [%] Cycle efficiency [%]
71.4 12.81
efficiency of expander [%] Cycle efficiency [%]
67.9 8.01
efficiency of expander [%] Cycle efficiency [%]
56.6 3.65
efficiency of expander [%] Cycle efficiency [%]
71.4 40.76
efficiency of expander [%] Cycle efficiency [%]
100 10.98
efficiency of expander [%] Cycle efficiency [%]
100 13.55
efficiency of expander [%] Cycle efficiency [%]
100 14.33
efficiency of expander [%] Cycle efficiency [%]
100 15.03
efficiency of expander [%] Cycle efficiency [%]
100 16.36
efficiency of expander [%] Cycle efficiency [%]
100 17.02