You are on page 1/ 2

Alcatel-Lucent Enterprise Summary of installation Steps • 4- or 8-conductor, CAT5 or better UTP cable of required length.

• Power sources:
OmniAccess Stellar AP1230 Series • WLAN Planning. Usually, a comprehensive site survey is required a) For full-function running mode (Tri-Radio,2.4GHz 4x4:4 +
Installation Guide before installation, such as installation location, brackets, cables, 5GHz 4x4:4), the following two kinds of power sources are
power source, etc. acceptable
060494-10 Rev. C
• Unpack the AP box and check all contents 1) IEEE 802.3at compliant PoE source with LLDP
*060494-10 Rev. C* • Install the AP bracket on ceiling or wall protocol supported, 60W, output voltage DC
• Installing the AP 48V(nominal), or
• Connecting required cables 2) AC/DC adapter (sold separately) ,output
• Power connection voltage DC 48V, output current > 0.75A
• Verifying post-installation connectivity When both power sources are available, DC power takes priority over PoE
• AP provisioning b) For Power safe mode (Tri-Radio,2.4GHz 2x2:2 + 5GHz
2x2:2, USB disabled), an IEEE 802.3at compliant PoE
AP is a radio transmission device and subject to governmental regulation. source is acceptable
Network administrators must comply with local regulations. • A PC terminal or a notebook

Package Contents Figure 2: AP Front View


Identifying Specific Installation Locations
Item Name Qty Unit You can mount the OmniAccess Stellar AP on a ceiling rail (using the
1 Access Point 1 Pcs shipped bracket in the box) or on a wall (using the wall mount
Quick Start Guide 1 Pcs adapter, sold separately). You should first determine the location of
Installation Guide 1 Pcs the installation. The installation position is located at the center of
2 the required coverage area and should be free from obstructions or
Regulatory Compliance and Safety
1 Pcs obvious sources of interference.
Information
User Guide Info Card 1 Pcs • Minimize the number of obstructions (such as walls) between the AP
3 Mounting Bracket (15/16”) 1 Pcs and user terminals.
4 Mounting Bracket (9/16”) 1 Pcs • Electronic equipment or devices (such as microwave ovens) which may
produce radio frequency noise should be away from the installation
position of the AP.

A good mounting location is important to getting the best performance


out of your access point. Keep the following in mind:
• In most occasions, the AP should have unobstructed line of sight
to most coverage areas.
• The AP1231 access point is not plenum rated, and you must not
install above suspended ceilings or in closed enclosures that
have limited air flow.

It is strictly prohibited to install around stagnant water, water seepage,


leakage or condensation. Avoid cable condensation or water seepage along
the cables connecting to the AP.

Temperature and Humidity requirement


Figure 3: AP Back View • Operating temperature: 32ºF to 113ºF (0ºC to 45ºC)
• Storage temperature: -40ºF to 158ºF (-40ºC to 70ºC)
Figure 1: Product Packing • Relative Humidity: 10% to 90% non-condensing
Item Name Specifications
Inform your ALE sales representative of incorrect, missing, or Factory reset. Press reset button for 5s, AP LEDs will
damaged parts. If possible, retain the carton, including the RESET quickly flash for 3s, then AP will restart and restore AP Installation
original packing materials. Use these materials to repack and factory configurations.
return the unit to the supplier if needed. Additional mounting kits USB USB 2.0 host interface (Type A connector) Using Ceiling Mounting Bracket
for use with the OmniAccess Stellar AP1230 series access points Make sure the AP fits securely on the ceiling tile rail when hanging
1Gigabit 1x 10/100/1000BASE-T autosensing (RJ-45) port,
are sold separately. Contact your ALE sales representative for the device from the ceiling, poor installation could cause it to fall
Ethernet Power over Ethernet (PoE)
details. onto people or equipment.
2.5Gigabit 1x 100/1000/2.5GBASE-T autosensing (RJ-45) port,
Ethernet Power over Ethernet (PoE) The OmniAccess Stellar AP has been shipped with two mounting brackets
Unboxed OAW-AP1231: The console port is an RJ-45 female connector and for 9/16” and 15/16” ceiling rails. Following is the general sequence to
• Net Weight: 3.34lbs / 1.516kg can be used to connect to a terminal for direct local install the AP with the mounting bracket.
CONSOLE
• Dimensions (H×W×D): 9.1 inches × 9.1 inches × 1.81 inches management. • Pull the cables through a prepared hole in the ceiling tile near
(23 cm × 23cm × 4.6cm) Note: Currently for use by Service & Support only. where the AP will be placed.
The AP has a single 48V DC power jack socket to • Place the bracket against the back of the AP, insert by aligning the
support powering through an AC-to-DC power slot on the backside with the hanging feet on both sides of the
48VDC adapter. If PoE is not available, an optional AC-DC bracket (see Figure 4).
adapter kit (sold separately) can be used to power • Push the bracket along the direction of the arrow until it locks in
the AP. the slot (see Figure 4).
enterprise.alcatel-lucent.com
Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel-Lucent. To view Device view Kensington The AP is equipped with a Kensington lock slot for • Connect the cable to the port on the AP.
other trademarks used by affiliated companies of ALE holding, visit: enterprise.alcatel- The OmniAccess Stellar AP is equipped with one hidden LED light that Lock Slot additional security. • Hold the AP next to the ceiling tile rail with the ceiling tile rail
lucent.com/trademarks. All other trademarks are the property of their respective owners. The indicates different status with distinct color or flashing.
information presented is subject to ALE without notice. Neither ALE Holding nor any of its
Table 1: External Interfaces mounting slots at approximately a 20-degree angle to the ceiling tile
affiliates assumes any responsibility for inaccuracies contained herein. (2018) rail (see Figure 5). Make sure that any cable slack is above the
ceiling tile.
Pre-Installation Checklist • Pushing toward the ceiling tile, rotate the AP clockwise until the
Before installing your OmniAccess Stellar AP, be sure that you have the device clicks into place on the ceiling tile rail (see Figure 5).
following items:
Network normal, without
Flash System running
SSID created
Network normal, single
ON System running band working, either
2.4GHz or 5Ghz
Network normal, dual bands
ON System running working, 2.4Ghz and 5Ghz
are both working
Red and Blue LEDs alternate
Flash Flash System running flashing in specific
frequency; OS upgrading
Figure 4: Attaching the Ceiling Mounting Bracket
3 LEDs alternate flashing in
Flash Flash Flash System running specific frequency; Used for
locating an AP
Table 3 OmniAccess Stellar AP LED Meaning

Console Port
The serial console port allows you to connect the AP to a serial terminal
or a laptop for direct local management. This port is an RJ-45 female
connector with the pinouts described in Table 4.
Figure 7
Note: Currently for use by Service & Support only.

Connector Pin Signal Name Function


3 TXD
4 GND
5 GND
6 RXD

Figure 5: Mounting the AP Pins not listed are not connected

Connect Ethernet Table 4: Console Port Pinout


Use the Ethernet port to connect the AP with a twisted pair Ethernet LAN
segment. Use a 4- or 8-conductor, Category 5 UTP cable. The port is an Configuring the OmniAccess Stellar AP
RJ-45 female connector with the pinouts shown in Table2. Refer to the Quick Start Guide and Configuration Guide for complete Figure 8: With external antennas
Ethernet Port Signal details.
Pin Function The external antennas are sold separately.
/RJ45 Female Name
1 BI_DA+ Bi-directional pair +A, PoE Negative Unboxed OAW-AP1232 (external antenna)
2 BI_DA- Bi-directional pair -A, PoE Negative • Net Weight: 3.48lbs / 1.58kg
3 BI_DB+ Bi-directional pair +B, PoE Positive • Dimensions (H×W×D): 9.1 inches × 9.1 inches × 1.81 inches (23 cm x
4 BI_DC+ Bi-directional pair +C, PoE Positive 23cm × 4.6cm)
5 BI_DC- Bi-directional pair -C, PoE Positive
6 BI_DB- Bi-directional pair -B, PoE Positive Device view Contacting Alcatel-Lucent Enterprise
7 BI_DD+ Bi-directional pair +D, PoE Negative Website Support
8 BI_DD- Bi-directional pair -D, PoE Negative
Main Site http://enterprise.alcatel-lucent.com
Table 2: Ethernet Port Pinout Support Site http://support.esd.alcatel-lucent.com
Telephone Support
Connect Power Sources
Confirm that the Ethernet cable is loaded either with 48V DC (nominal) North America 1-800-995-2696
60W/802.3at compliant PoE source (with LLDP protocol) for full-function Latin America 1-877-919-9526
running mode, or just with 802.3at compliant PoE source for power safe Europe +800 00200100 (Toll Free) or +1(650)385-2193
mode.
Asia Pacific +65 6240 8484
If not, connect by using the ALE 48V AC-DC adapter kit (sold separately)
Other Region 1-818-878-4507
to the DC Power Socket and AC power jack.
Figure 6
If both PoE and DC power are available, the use of DC is preferred.
OmniAccess Stellar AP supports the power adapter provided by ALE It is installed in the same way as OAW-AP1231 for the AP installation. In
ONLY. Figure 7, it is shown the way to install the external antennas.
[REMAINING SECTIONS INTENTIONALLY LEFT BLANK]

Verifying Post-Installation Connectivity


The LED on the AP can be used at this point to verify that the AP is receiving
power and initializing successfully (see Table 3).

Time
Red Blue Green Status
Line
ON Power on
Bootloader-OS
ON System start up
loading
Network abnormal
Flash System running
(Interface down)