EQUIPMENT DATA
Equipment Type/Configuration Shell and Tube Exchanger (Type NEN), Saddle Supported
Shell Side: CS
External Material of Construction
Tube Side: CS
Shell Side: 347/106 (base case) 427/188 (alternate case)
Operating Temperature, inlet/outlet (°C)
Tube Side: 70/310 (base case) 70/420 (alternate case)
Shell Side: 125 (steam-out)
Cyclic or Intermittent Conditions (°C)
Tube Side: 125 (steam-out)
Note: Any changes to the equipment data above may result in a corresponding change to the data below.
SHOP DATA
V42-1TS-6315, General Coating Procedures
6315-V10-PI-C03, Coating System 3, Inorganic Zinc + Modified Silicone
Shop Specifications
6315-V10-PI-C05, Coating System 5, Inorganic Zinc (Insulated)
6315-V10-PI-C06, Coating System 6, Epoxy + Epoxy Barrier Coating
Insulation Support Shop
Fireproofing Applied
Equipment Surface Description Thk Notes
Type Thk (mm) Coating
(mm) System
Shell side 5
Inlet Hot 140 -- 6
Tube side
Outlet 5
Saddles None -- None 3
Shop Note(s):
FIELD DATA
V42-1TS-6315, General Coating Procedures
Field Specifications V42-2TS-6315, Field Coating Procedures
V40-1TS-6315, Installation of High Temperature Insulation
External Coatings Repair shop applied coatings per specifications listed above.
Support Fireproofing None
Insulation
Equipment Surface Description Thk Notes
Type
(mm)
Shell side
Inlet 1 140 Alt. Case
R2 Tube side
Outlet
Saddles None --
Field Note(s):