Product Specifications
Precision
Parameters Carry-over Linearity Range
Range CV
9
(7.0 ~ 15.0 )× 10 / L ≤2.0%
WBC ≤0.5% 9
9 (0.0 ~ 99.9) ×10 / L
(4.0 ~ 6.9) × 10 / L ≤3.5%
12 12
RBC (3.50 ~ 6.5)× 10 / L ≤1.5% ≤0.5% (0.0 ~ 7) ×10 / L
HGB 100 ~ 180 g/L ≤1.5% ≤0.5% (0.0 ~ 240) g/ L
MCV 70.0~ 110.0 fL ≤0.5% (0.0 ~ 250.0) fL
9
(150 ~ 500) × 10 / L ≤4.0%
PLT ≤1% (0.0 ~ 999) × 10 / L
9
(100 ~ 149) × 10 9/ L ≤5.0%
Impedance method for cells counting Auto 3-Diff Hematology Analyzer
Principle
Cyanide free colorimetric method for HGB measurement
Counting Modes Whole Blood, Pre-diluted Blood
Throughput 60 samples/hour
Whloe Blood: 9.9μL
Sample Volume
Pre-diluted Blood: ≤20μL
21 Parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB,
MCV, MCH, MCHC, RDW-CV, RDW-SD, HCT, PLT, MPV, PDW, PCT, P-LCR, P-LCC
Parameters
3 Histogram: WBC, RBC, PLT
Reagent 2 reagents + 1 maintenance cleanser
10.4-inch touch screen
Input
Mouse, Keyboard
Reference value Settings Preset 5 sets of reference values: Man, Woman, Child, Baby and General
Calibration Manual, Calibrant, Fresh Blood
Data Ports 1 network port, 1 RS-232 port, 4 USB ports
Power AC110/115V or AC220/230V, 50Hz Input power:≤150VA
Operating Temperature 10℃~30℃
Relative Humidity ≤70%
Atmospheric Pressure 70kPa~106kPa
Add: Floor 11, Building 1B, BTR Technology Park, Longtian Street,
Pingshan District, Shenzhen, P.R. China
Email:
[email protected]Highlight Feature Product Advantages Correlation
Comparison result with S brand
Advanced Parameters
y=0.9819x + 3.2725
21 Parameters, 3 Histograms R²=0.9816
y=0.9924x + 0.0568 180
9 Language 3 Calibration mothods: Possible choice of parameter units, Several languages R²=0.9803
y=1.0094x - 0.0217
Manual,Calibrant,Blood 7
avaiable 14
R²=0.998 160
6 140
12
WBC
RBC
PLT
5 120
10
100
8
4
0 50 100 150 200 250 300 fL 0 50 100 150 200 fL 0 5 10 15 25 fL 80
6 3
60
4 2
40
Block-clearing Abnormal histogram alarm 2
1 20
Automatic re-counting 10.4 Inch touch screen
Soak and wash back and forth. real time monitoring If the histogram of the sample analysis result is 0
0 0
0 2 4 6 8 10 12 14
function of high pressure burning and automatic abnormal. The machine will automatically generate 0 1 2 3 4 5 6 7 0 20 40 60 80 100 120 140 160 180
block-clearing a histogram alarm. Prompt R1, R2, R3, R4, Rm, Pm WBC
RBC HGB
according to the type of exception
Rm y=1.0047x - 0.1691 y=1.0146x - 1.8489
WBC
R2 R²=0.9863 500 R²=0.9763
R3
100
90 450
fL
80 400
70 350
Pm
2 counting modes Whole 60 300
PLT
Blood, Pre-diluted Blood
50 250
Lyse inside the analyzer,
high space utilization 40 200
fL
30 150
20
High Accuracy Cost Efficiency
100
10 50
Double channel counting, no cross-contamination 2 reagent: Diluent and Lyse 0
0
0 10 20 30 40 50 60 70 80 90 100
between channels and low carryover rate Low reagent consumption 0 50 100 150 200 250 300 350 400 450 500
Automatically adjusting voltage of HGB blank, Auto- MCV
Lyse inside the analyzer, high space utilization
matically adjust alarm thresholds of clogging and PLT
bubble of counting apertures
RBC
PLT RBC LED
PLT HGB
Automatic re-counting
Routine reagent
Safety design
Automatically re-counting after unclogging treatment Diluent 20 L
AerC-3 Auto Hematology Analyzer is a clinical test instrument with rich functions and easy while a counting hole is clogged, avoid re-counting
Circuit and liquid separation, safety protection
operation. It can provide 21 parameters and 3 histograms. Double channel counting. During blood Convenient maintenance Lyse 500 mL
the sample analysis process, automatic blockage removal and automatic re-counting ensure
Maintenance reagent
accurate and stable test results. Widely used in hospital laboratories, clinical departments
and research centers. Cleaner 50 mL