Grease separator EasyClean free NS 25, Auto Mix & Pump
Article information
Item no.: 93025.01/PVS
GTIN:
Price group: 60
Advantages
Clean and odour-free disposal and cleaning
Customisation possible through control unit
Description
The separator for greasy wastewater is suitable for free-standing set-up in frost-
protected rooms and comes without metallic components in the tank. The
collecting tank made of permanently resistant polymer (PE) is equipped with an
integrated sludge trap and has slopes in the tank base for fast and clean disposal.
Two odour-tight covers with quick-release closures make easy access possible for
cleaning and maintenance work.
The innovative Shredder-Mix-System with integrated macerating system is
responsible for homogenising and circulating the tank contents. Cleaning and odour-
neutral disposal takes place via an exterior pump with 2-way valve and actuator
which can be disconnected from the tank by a shut-off valve.
The fully automatic program run is controlled by a user-friendly control unit with
multi-line display that can be integrated into the building management system
through a potential-free contact. Cleaning and disposal can be started remotely
using the remote control, which is available as an option.
Thanks to the customisable cleaning program with fast-selection function, cleaning
can be adapted to the local circumstances as required. Observance of the Drinking
Water Hygiene Directive can be guaranteed through the fully automatic rinsing of
the drinking water pipes.
20 year polyethylene warranty.
Installation situation: free-standing set-up
Version:
Shut-off valve: yes
Type of disposal: automatic disposal and cleaning system
Disposal system: Disposal pump
Disposal variant: Auto Mix & Pump
Refill inlet in accordance with DIN 1988: yes
Page 1 Subject to technical changes. 06.04.2023
Nominal size (NS): 25
Inspection window: yes
Shredder-Mix-System: yes
SonicControl: no
Water supply: 2 solenoid valves 1"
Load-bearing capacity (DIN 19901): F3
Delivery state: Installation-ready (electrical components,
connection parts must be connected on site)
Scope of delivery: Storz-B coupling R 2 1/2" for disposal vehicle
connection
General characteristics:
Material: PE
Standard: EN 1825
Dimensions:
Set-up area, length: 4,760 mm
Set-up area, width: 1,620 mm
Set-up area, height: 1,555 mm
Required access area, length: 4,500 mm
Required access area, width: 1,350 mm
Required access area, height: 1,525 mm
Tank:
Inlet nominal size (DN): 200
Inlet nominal size (OD): 200 mm
Outlet nominal size (DN): 200
Outlet nominal size (OD): 200 mm
Distance pipe bottom inlet to tank bottom: 1,100 mm
Distance pipe bottom outlet to tank bottom: 1,030 mm
Pressure pipe connection (DN): 65 mm
Pressure pipe connection (OD): 75 mm
Nominal pressure (PN): 10
Connection inlet/outlet sockets: PE-HD pipes in accordance with DIN 19537, HT pipes
in accordance with DIN 19560, PP or AS
Coverage features:
Type of cover: Cover
Cover material: Polymer
Colour of cover: black
Tightness: odour-tight
Locking: Quick-release closure
Page 2 Subject to technical changes. 06.04.2023
Wastewater contents:
Separator contents: 1,200 l
Total volume: 3,700 l
Contents of sludge trap: 2,500 l
Storage quantity of grease: 1,000 l
Pumping device:
Pump: SPF 300 KE 2.0
Number of pumps: 2
Max. pumping capacity: 60 m3/h
Max. pumping height: 17 m
Operating voltage: 400 V
Mains frequency: 50 Hz
Operating mode: S2 - 30 min.
Power P1: 3.6 kW
Power P2: 3 kW
Speed: 2,850 U/min
Type of fuse required (electrical protection): Fuse protection through control unit 400 V
Max. temperature (permanent) of conveyed 40 °C
material:
Connection type: Direct connection
Weight: 44 kg
Impeller type: Radial impeller with macerating system
Length of mains cable for pump: 5m
Rated current: 6.2 A
Protection class (pump): IP 55
Protection class: I
Type of pump connection cable: H07RN-F 7G 1.5 mm2
Temperature monitoring: integrated
Cos phi - power factor: 0.87
Insulation class: F
Control:
Control unit: yes
Operating voltage: 400 V
Mains frequency: 50 Hz
Self-diagnosis system (SDS): yes
Battery buffering: no
Multi-line display: yes
Log book function: yes
USB interface: yes
GSM interface: no
Potential-free contact: yes
Type of fuse required (electrical protection): C 16 A
Page 3 Subject to technical changes. 06.04.2023
Type of fuse required (RCD): 30 mA
Motor protection switch: yes
Protection class control unit: IP 54
Page 4 Subject to technical changes. 06.04.2023