0% found this document useful (0 votes)
39 views1 page

03 408301 4800000882 FHD Mec DRG 000003

Uploaded by

vijay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views1 page

03 408301 4800000882 FHD Mec DRG 000003

Uploaded by

vijay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6

GENERAL KEY PLAN: N

QIBLA

ROAD ROAD

ODOR
CONTROL UNIT

29 29 30 30 29 DISINFECTION TANK SHADED AREA

6.34
DIM

3.95

SHT
3
x
:
m

)L
x (W
.Dm
W

)
AIR BLOWERS
EQUALIZATION
& FOR

29

2.54
DIM

7.5
:
MBR TANK
m

(L
)x
DIM

)X:m
(L
AERATION
6 .44

(W
)Xm
TANK
3

(W
.D
) m
2.2

DIM
20
m
(4
TH
W

)x

:
EQUALIZATION
m

13
X(W
)Lm
X TANK

(W
.D
) m
3
m
(42.54
DIM
:2.2
MBR
T
W
m H TANK

(L
)x

7.5
DIM

)X:m
(L
AERATION
6 .44

(W
)Xm
TANK
3

(W
.D
) m
SLUDGE BREAK TANK

DIM

x .95

DIM
6.1
6.34
x

(W
.D
):L m
3
m

(W
ANOXIC TANK
m

W
m
X

m
)

)X
5(L

(W
.D
) 3
ROAD

17 ROAD

DIM

DIM
10
x
:SLUDGE HOLDING
3

W
.D
4
)xm
(L
W TANK

10
:m
)

3
x
(
UTILITY BUILDING
(W

(W
.Dm
5L
)x
VJA-PS-ME Review: (17-10-2024):
30 30 29 29 30 COMPACTOR

COMPACTOR

24
16

29

. 10 . 10
18
30

22 21
Warehouse Facility +
Laundry
Workshop

. 12
13

.
30
28

. 23 ADMIN500 sqm
1 SUPERMARKET1500 sqm

.
PUMP ROOMFOR

WATERTANK WATER FIRE


FUTUREWATER

&
.5
VET150
sqm 5000M3 TANK 5000M3

RECREATIONAL POOL

FIRE TANK 600M 3

FIRE TANK 600M 3


240.00
m

²
No Comments
8c .9

.
8c 16-MEP BOH Utilities

.
. 4GYM 8b. 16-MEP BOH Utilities
11.25 3

m
GENSET GENSET

DT
DT 11.25

3
90m 3 ST

EXERCISING
500m POOL

DT
90m 3 ST

m
²
11.25m
DT 3 11.25

3
GENSET GENSET

8c 11.25m 3 11.25 90m 3 ST

3
GENSET GENSET

DT
DT

.9 90m 3 ST

4
inch Supply Header
GENSET GENSET

DT
11.25m
DT 3 11.25

3
90m 3 ST

11.25m
DT 3 11.25

3
GENSET GENSET DT 90m 3 ST

8c 9

.
Duplex GearPump

.
100GPM 90m 3 ST

BUILDING
11.25m 3 11.25

3
DT GENSET GENSET DT

6CLINIC 90m 3 ST

11.25m
DT 3 DT 11.25

3
GENSET GENSET
90m 3 ST

11.25m 3 11.25

3
DT GENSET GENSET DT 90m 3 ST

90m 3 ST
11.25m
DT GENSET GENSET DT 11.25

m
3

3
90m 3 ST

4
11.25m
DT 11.25

m
3

3
GENSET GENSET

inch Filling Header


DT

90m 3 ST

11.25m 11.25

m
3

3
GENSET GENSET 90m 3 ST
. 2FOOD COURT
DT DT

. MOSQUE 640sqm

DT
11.25m 90m 3 ST Filling Cabinet

m
3
DT 11.25

3
GENSET GENSET
Duplex Gear Pump
200GPM

E
. 33SCHOOL

33
SALON &FB-1&FB-2&FB-3

G
01-000
CAFE
106.58

m
²
3 3 3

Micro-mobilityCHARGING AREA

NEV Pick-up / Drop-off

OUT
Parking = 10

Micro-mobility eScooters Parking = 25 Micro-mobility eBikes Parking = 15

GATE
SHADED PARKING AREANEV OVERNIGHT
GENERAL PARKING ( 35 spaces ) Fire Extinguisher
PARKING (10 SPACES)

27 20 OUT OF SCOPE

2
NEV SERVICE , CLEANING
A = ~1000 m & MAINTENANCE AREA

2
RIDE-HAILING STAGING(10
A ~ 300 m
CHARGING

IN
GENERAL PARKING (18 spaces)

DROP OFF(3
GENERAL PARKING (

SPACES)
CLUSTER

SPACES )
26 spaces ) Bus bays – Outdoor passenger waiting area

18- PARKING LOT


BUS 6 BUS 5
BUS 4

DROP OFF(3
GENERAL PARKING ( GENERAL PARKING (

SPACES)
19-Regional Transit Hub

EMERGENCY LANE
26 spaces ) 26 spaces )

BUS 1 BUS 2
BUS 3

ONLY BUS LANE


CARSHARING ( 35 spaces )

ONLY BUS LANE


EMERGENCY LANE
Additional bus parking / overnight parking area

THREAD ROD M10≤


1

NUT M10
REFRIGERANTPIPES NOTES:
SPRING WASHER M10
FLAT WASHER FOR M10
ANGLE REINFORCED STANDINGSEAM
NEOPRENE RUBBER PAD 15.0mm(T) MASTIC SEALANT 1. ALL MECHANICAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH GENERAL NOTES,
FLAT WASHER FOR M10 ALLAROUND
SPECIFICATION, DETAILS AND ARCHITECTURAL, STRUCTURAL AND ELECTRICAL FINAL
NUT M10
GALVANIZED STEEL FLASHING BEDDEDIN DESIGN DRAWING.
MASTIC AND SECURED WITHGALVANIZED 2. ALL DUCT SIZES MENTIONED ON PLANS ARE CLEAR SIZES, EXCLUDING THE THICKNESS OF
SLIP
STEEL CLAMPING RING DRIVE
INSULATION AND OTHER DUCT LINING.
CONDENSING UNIT
3. UNLESS OTHERWISE INDICATED, ALL DIMENSIONS ARE IN MILLIMETERS.
SECTION 01

Ø
4. ALL BOTTOM OF DUCT (BOD) ARE FROM FINISH FLOOR LEVEL (F.F.L.) UNLESS OTHERWISE
REFRIGERANT
THREAD ROD PIPESUPPORT (TYP.) PITTSBURGH LOCK ON ALLLONGITUDINAL
SPECIFIED.
CONCRETE BASE
REFER JOINTS OF TAPEREDSIDES 5. DUCTWORK, FITTINGS, HANGERS AND ACCESSORIES SHALL BE AS PER SMACNA

300 MIN.
DETAIL NO3. RECOMMENDATIONS AND AS SPECIFIED IN THE SPECIFICATION AND APPROVED MATERIAL
SUBMITTAL.
NOTE : 6. ACCESS DOOR SHALL BE PROVIDED FOR ALL VD, FD, SMD, MVD,VALVES AND ALL
RUBBER PAD ISOLATOR Ø EQUAL 20° MAXIMUM FOR DIVERGING FLOW
ELECTRICAL EQUIPMENT/COMPONENTS INSTALLED IN CONCEALED AREAS.
& 30° MAXIMUM ON CONTRACTING FLOW 7. ALL DUCTWORKS TERMINATING WITH BELL MOUTHS SHALL BE PROVIDED WITH AN
CAST IN INSECT SCREEN.
REFRIGERANT PIPESLEEVE
NEOPRENE BASE
PIPESSUCTION AND
8. AIR OUTLETS SHOWN ON DRAWING ARE LISTED SIZES UNLESS OTHERWISE INDICATED,
LIQUID TO FCU FOR NECK AND FACE SIZE REFER TO MATERIAL SUBMITTAL MANUFACTURER'S MATERIAL
D RC 8 DETAIL-TAPERS AND OFFSETS
CEILING ROOFSLAB G-M-003 NTS
CATALOGUE.
NOTES: 9. ALL MECHANICAL EQUIPMENTS SIZES SHOWN ON DRAWING ARE APPROXIMATE. FINAL
1. FOR ROOF CONSTRUCTION AND FLASHING & COUNTERFLASHING SIZES SHALL BE AS PER APPROVED MATERIAL SUBMITTAL EQUIPMENT SELECTION.
DETAIL, REFER TO ARCHITECTURAL DRAWING.
10. ACCESS PANEL SHALL BE PROVIDED FOR EACH AHU, FCU, FOR VALVES AND
CONCRETE SLAB
MAINTENANCE.
TYPICAL DETAIL OF FCU CEILING CASSETTE
SCALE NTS
ANCHOR (AS PER RODSIZE
TABLE-2)

1 INSTALLATION OF FCU CEILING CASSETTE A/C UNIT EVAPORATOR (INDOOR UNIT)


2 INSTALLATION OF SPLIT A/C UNIT (CONDENSING UNIT) 3 REFRIGERANT PIPES THRU ROOF DROP ROD - 2 Nos
G-M-004 NTS G-M-004 NTS ALLTHREADED (FOR
G-M-004 NTS SIZESEE TABLE-2)

1200mm.(MAX.)
DUCTINSULATION
(ASPER DETAIL)
EXPANSIONANCHOR
HARDWOOD
SOCKET(TYP.)
PAD100x100x25HIGH DUCT
EYE UNDERSIDE
BOLT(TYP.) OFSLAB MS ANGLE (FOR SIZESEE
3 STEEL TABLE-2)
STEEL HANGINGROD OR
HANGINGWIRE (8G) WIRE
4 (TYP.) THERMALINSULATION
INSULATED
DUCT 25 25 DUCT SIZE 25 25
REFRIGERANTPIPE FLEXIBLEDUCT (MAX. L
INSULATEDAND LENGTH1200mm)
1
VAPOURSEALED INTERNALLYINSULATED ANGLE
DIFFUSERADAPTER IRONSUPPORT
13mmTHICKNESSINSULATION SUCTION PIPE HARD NON-HEAT CONDUCTINGMATERIAL AS

H
APPROVED TO REST ONANGLE IRON
2
OPPOSED
BLADEDAMPER 25 SUPPORT HORIZONTAL DUCT
MMBANDCLAMP
CORACLOTH 25mm*0.6mmTHICK GI MANUAL VOLUME
3 SUPPORT RECTANGULAR DUCT
ACOUSTIC CEILING G-M-002 NTS
SHEETPAINTED WITH LIQUID PIPE DIFFUSER'SINLET CONTROLDAMPER
REDOXIDE FACE SIZE STAINLESS STEEL WORM DRIVECLAMP
FLAT FOR DUCTS UP TO 150mmDIAMETER
VARIES
BAR25mmWIDE AND BAND CLIP FORLARGER SIZE
A. EXPOSED TO VIEW 10mm SQUARE ROD VOLUME DAMPER
NOTE: W
WITHLOCKING TYPE
100 1. CLOSED CELL TUBE INSULATION 13mm - DIFFUSER'S ADAPTOR DIMENSIONS (L X W X H) ARE APPROXIMATE INDICATORQUADRANT AND
DIFFUSER DIFFUSER'S ADAPTOR WITH INTERNAL
250 2. THICKNESS ADHESIVE FOSTER 85-20 OR EQUIVALENT AND TO BE VERIFIED / CONFIRMED BY THE DIFFUSER'S MANUFACTURER. BRANCH DUCT SADDLETO CLEAR INSULATION
3. 4 OZ CORA CLOTH BONDED ON TO INSULATION WITH 2 LAYERS OF ATLAS- FOSTER NECK INSULATION (25mm thick) DIMENSIONS
30-36 INLET (diam) END BEARING
LENGTH WIDTH L W H 1/4W, 100mm. MINIMUM
4. 2OREQUIVALENT
COATS OF VINYL BASED VAPOUR BARRIER-FOSTER 30-35 OR EQUIVALENT AND (mm) (mm) (mm) (mm) (mm)
CLADDED. 150 150 150 200 200 250
200 225 225 275 275 300 MAIN DUCT CLINCH COLLAR
250 300 300 350 350 350
300 375 375 425 425 400
350 450 450 500 500 450 45 0
C 400 450 450 500 500 500 SUPPLY
450 525 525 575 575 550 AIR FLOW
500 600 600 650 650 600 W
RETURN/EXHAUST
4 INSTALLATION OF REFRIGERANT EXPOSED PIPES 5 INSULATION OF REFRIGERANT EXPOSED PIPES 2 SQUARE SUPPLY CEILING DIFFUSER AIR FLOW
G-M-004 G-M-004 G-M-003 NTS
NTS NTS

NOTES
1. USE FOR SYMBOL WHERE
BRANCH DUCT AIR QUANTITY
IS LESS THAN 470 LPS.

RUBBER GASKET 2. NOT TO BE USED AS


SUBSTITUTE FOR ELBOW
FAN REFERENCE NUMBER DESCRIPTION
DUCT INSULATION DUCT INSULATION MOTORHOUSING

WALL WALL
RECTANGULAR DUCT
11 ANGULAR TAP WITH VOLUME DAMPER DAMPER
INSULATION
G-M-002 NTS 1
Y
Y

MFTRSTANDARDSTEEL
FAN
MOTORHOUSING
BACKDRAFT DAMPER DRAIN PAN
X
X CURBS
ANGLE FASTENED

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
RUBBER GASKET
TO SIDE OF DUCT
PRE-FILTERFILTER
Y
Y

2
VARIES

25 THK RIGID INSULATIONALL


INSULATOR SEE DETAIL "A" AROUND
SUPPORTING STAGE:
MEMBER
MFTR T.O.S.S
SLOPE SLOPE
25mm MIN. OVERLAP TOALL 3D TENDERING STAGE & IFC
STANDARDSTEEL SIDE OF DAMPER
CURBS 40mm. STANDING SEAM RIVETED

3
VARIES

ORBOLTED ON 300mm. CENTERS ANDWITH 6mm MIN.


FASTENER ANCHOR
DETAIL OF INSULATION-"A" FIGURE "B" ANCHOR
SUITABLE MASTIC SEALANT FLEXIBLE HORSE SHOE HEAT PIPE
NTS WATERPROOFINGFLASHING DUCTCONNECTOR
FIGURE "A" (WHEREREQUIRED) FIREDAMPER
BOLTS AND NUTS, SCREWS
FLASHING STEEL FRAME (ASPER EXHAUST TACKWELDS OR STEEL POP
FAN SIZE) ROOF OPENING DUCT(WHEREREQUIRED) RIVETS300mm MAX. C/C
SUGGESTED SIZING SUGGESTED SIZING A 3D-TENDERING STAGE & IFC EH 21-09-2024

300 MAX.
25mm. THK RIGIDINSULATION
DUCT DUCT
DUCT SIZE
457x300mm
ANGLE
38.1x1.61mm
DUCT SIZE
762x305mm
ANGLE
25x25x3.2mm
ALL AROUND NOTES:
1. FOR FAN DETAILS AND OTHER ACCESSORIES REQUIRED SEE EQUIPMENTSCHEDULES 4 DX COIL REV DESCRIPTION APP DATE
914x457mm 25x25x3.2mm DUCT AND SPECIFICATIONS. PURPOSE OF ISSUE:

MAX.
610x508mm 25x3.2mm

75
SLOPE SLOPE
1067x610mm 31.8x31.8x3.2mm T.O.S.S 2. FOR REQUIRED ROOF OPENING REFER TO EQUIPMENT MANUFACTURER'S CATALOG.
1219x914mm 31.8x31.8x3.2mm 3. FOR ROOF CONSTRUCTION AND FLASHING & COUNTERFLASHINGDETAIL, SEE
ARCHITECTURAL DRAWING.
FOR APPROVAL
150
5
SLAB OPENING
4. PROVIDE SAFETY DISCONNECT SWITCH INSTALLED ON MOTOR MOUNTINGPLATE UNDER 40x40x4mm THICK
M.SGALVANISED ANGLE
MAX. ACCESS DOORAS
PER SMACNA ELECTRIC COIL CLIENT: PROJECT MANAGEMENT CONSULTANT:
C:\Users\engeh\Desktop\30 COFFEE SHOP+SALON+F&B\02 SALON\01-SALON-HVAC-3D\01 RVT\03-408301-4800000882-FHD-MEC-3DM-000001-SALON-3D.rvt

MOTOR DOME.
TABLE DUCT GAUGE NOTES: 1. FOR FAN DETAILS AND OTHER ACCESSORIES REQUIRED SEE EQUIPMENT SCHEDULES AND SPECIFICATIONS.2. FOR REQUIRED ROOF 5. FOR KITCHEN EXHAUST FAN THE BACKDRAFT DAMPER AND FLEXIBLEDUCT
ALLOWABLE LOAD 0.48,0.58mm 11.3 KG 1. BRACKETS ARE SIZED FOR 3.7M OF DUCT, MAXIMUM. OPENING REFER TO EQUIPMENT MANUFACTURER'S CATALOG.3. FOR ROOF CONSTRUCTION AND FLASHING & COUNTERFLASHING DETAIL, CONNECTOR SHALL BE DISREGARDED. 6mm CLEARANCE
PER FASTENER 0.70,1.00mm 16 KG 2. LOCATE DUCTS AGAINST WALL OR MAXIMUM OF 51MM AWAY FROM WALL. SEE ARCHITECTURAL DRAWING.4. PROVIDE SAFETY DISCONNECT SWITCH INSTALLED ON MOTOR MOUNTING PLATE UNDER MOTOR DOME.5.
1.31, 1.61mm 23 KG 3. EACH WALL ANCHOR SHALL SATISFY THE FOLLOWING CRITERIA UNLESS OTHER FOR KITCHEN EXHAUST FAN THE BACKDRAFT DAMPER AND FLEXIBLE DUCT CONNECTOR SHALL BE DISREGARDED.

B
WELD, BOLT OR NO.8 SCREW (MIN.) DEVIATION PERMITTED BY OTHERANALYSIS.
X= 25mm, Y= 51mm; ADD OTHERS TO ACCOMODATELOAD. MINIMUM OF 3 ON
ANALYSIS IS MADE:
A. TENSILE LOAD= 3/8xDUCT WEIGHT;SAFETY FACTOR 4.
6 SUPPLY FAN
610mm WIDTH AND UP. ADD ALONG SIDESNEAREST ANCHORS. * B. SHEAR LOADx1/2xDUCT WEIGHT;SAFETY FACTOR 4.

8-B ROOF MOUNTED EXHAUST FAN (TYPE 2) 8-A ROOF MOUNTED EXHAUST FAN (TYPE 1)

8 FIRE DAMPER INSTALLATION DETAIL (VERTICAL)


8 ROOF MOUNTED EXHAUST FAN G-M-002 NTS
G-M-004 NTS
DESIGN CONSULTANT NAME & LOGO (s): CONTRACTOR NAME & LOGO (s):
10 SUPPORTS FOR VERTICAL INSULATED AIR DUCT
G-M-003 NTS

DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:


DRAWN: AL-FAHD 19/09/204
CHECKED: AL-FAHD 20/09/204 CHECKED: NEOM
APPROVED: AL-FAHD 21/09/204 APPROVED: NEOM

SCALE: NTS SHEET SIZE: A0


DISCIPLINE NAME:
MECHANICAL-HVAC
SALON &FB-1&FB-2&FB-3

HVAC GENERAL DETAILS


PROJECT NAME:

A SOUTH BUSNIESS COMMUNITY EXPANTION

NEOM COMMUNITY EXPANSION


NEOM
KINGDOM OF SAUDI ARABIA
REGION ASSET CODE CONTRACT CODE

03 408301 4800000882
9/21/2024 7:16:51 AM

DRAWING NUMBER

ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

FHD MEC DRG 000003 A


NEOM-NEN-PRC-009_TMP12_02.00

You might also like