Data Sheet

Electronic thermostat control


Type ETC 1H

For simple commercial refrigeration applications

The ETC 1H is introducing a flexible platform


due to onboard micro-controller and software
dedicated product configuration, perfect for
light commercial refrigeration applications.
Standard versions with similar functionality as
the traditional electro-mechanical thermostats
as well as several customized high performance
software versions for various applications are
available.

The ETC 1H is developed for applications such


as:
• Refrigerators
• Bottle coolers
• Freezers
• No-frost freezers with heating element
• Medicine coolers

AI215986425643en-000501
Electronic thermostat control, type ETC 1H

Features

• ETC 1H can control the cabinet temperature directly


• ETC 1H has low energy consumption
• 1 or 2 sensors (Air, evaporator) and optional remote display can be connected
• Using NTC temperature sensors
• Temperature control independent of barometric pressure
• High accuracy combined with close differentials and narrow tolerances ensures improved control
• Built in timers enhances functionality
• Optional alarm for over or under temperature in both cold and warm
• Auxiliary relays: 5 Amp for heater, fan, light etc. Eventually with delayed start or/and stop
• Under voltage and over voltage compressor protection (brown-out protection)
• Pressure equalisation protection on starting the device or when voltage drops out (blackout protection)
• Diagnostics and self check of sensors and potentiometer
• Several defrosting methods can be handled:
◦ Time controlled defrosting
◦ Time controlled defrosting with evaporator sensor
◦ Temperature controlled defrosting
• Dual band control of outdoor bottle coolers
• Quick Parameter Programming using PC software tool and Gateway
• Hydrocarbon refrigerant compatible relay outputs

Product specification

Technical data
Table 1: Technical data
Product specification 120 V, 60 Hz 230 V, 50/60 Hz
Power supply 115 V AC +/- 10% 60 Hz 220 V AC – 240 V DC +/- 10% 50 Hz
Energy consumption Max 0.5 Watt Max 0.5 Watt
Ambient temp. 32 – 122 °F 0 – 50 °C
Operating conditions
Humidity Max 90% RH, Non-condensing Max 90% RH, Non-condensing
Measuring range NTC sensor -40 – +185 °F -40 – +85 °C
IEC/EN 60730: 16(16) A
Relay output 1 Compressor UL 60730: LRA96, FLA16
UL 60730: LRA 60/ FLA 10
Relay output 2 Heater 5A 5A
IEC/EN 60730: 5 A
Relay output 3 Fan UL 60730: LRA 6/ FLA1
UL 60730: LRA 6/ FLA 1
NTC sensor +/- 1 K +/- 1 K
Accuracy
ETC 1H +/- 0.5 K +/- 0.5 K
Temperature sensors NTC- 5K NTC- 5K
Relay 1 +350,000 cycles +350,000 cycles
Life time Relay 2 +30,000 cycles +30,000 cycles
Relay 3 +30,000 cycles +30,000 cycles
Power 6.3 x 0.8 mm tabs, RAST 5 6.3 × 0.8 mm tabs, RAST 5
Connections 3-pole RAST 2,5 edge connector 3-pole RAST 2,5 edge connector
Signal/remote
2-Pole RAST 2,5 edge connector 2-Pole RAST 2,5 edge connector
Temperature indication Through optional remote display Through optional remote display
Approvals UL-C, NSF Semko, CE, CQC, EAC
EMC Category ------ Category-1
IP class IP 00 IP 00
Optional remote display with Control. 1- Optional remote display with Control. 1-
Remote control
wire protocol wire protocol
Number of sensors 2 (optional 3) 2 (optional 3)
Start-up-time < 2 seconds < 2 seconds

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 2


Electronic thermostat control, type ETC 1H

Functionality
Table 2: Functionality
Product specification Description
Settings Differential: -1 – 10 K , Range: 0 – 30 K, Defrost: 0 – 10 °C
Temperature
Adjustment Knob with stop 210° +/-5°. Stop 45°+/-5° o Knob angle without stop 255°+/-5°
Visual indication On-board LED (Red)
Diagnostics Function Self check of sensors and potentiometer
Sensor fault Air sensor
Brown-out Under-voltage and over-voltage protection
Compressor protection
Black-out Based on temperature at cabinet sensor
Mode 1 Start by Time- Stop by Cabinet Temperature (1 sensor)
Defrost Mode 2 Start by Time- Stop by Defrost Sensor (2 sensors)
Mode 3 Start and Stop by Defrost Sensor (2 sensors)
Types Over or/and under temperature in cold or warm
Alarm Flashing LED on the ETC 1H or by an external connected remote module or optionally to one of
Indication
the relays to control a buzzer
Monitor the condenser temperature and stop the compressor until the temperature goes below
Function
Blocked condenser the condenser warning temperature
On customer request only Flashing LED on the ETC 1H or by an external connected remote module or optionally to one of
Indication
the relays to control a buzzer

Parameters
It is possible to adjust the following parameters in the controller using Danfoss PC software tool ‘KoolProg’ and
Gateway.

For more information please visit: KoolProg

Table 3: Parameters
Parameter Min Max Default Unit
Thermostat Cold cut-out -65 50 0 °C
Warm cut-out -65 50 10 °C
0: cold
Default temp set also used as remote setpoint 0 1023 512
1023: warm
Cold differential -1 20 1 K
Warm differential -1 20 1 K
Compressor Min runtime 0 1800 300 Sec
Min stoptime 0 1800 300 Sec
Max runtime 0 10800 3600 Sec
Max stoptime 0 10800 5400 Sec
Error runtime 0 1800 600 Sec
Error Stoptime 0 1800 900 Sec
Alarm on relay Cold overtemp alarm -65 50 15 °C
Warm overtemp alarm -65 50 15 °C
Cold undertemp alarm -65 50 2 °C
Warm undertemp alarm -65 50 2 °C
Alarm delay 0 120 60 Min

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 3


Electronic thermostat control, type ETC 1H

Parameter Min Max Default Unit


Defrost 0: No defrost
1: Time start, Control T stop
Defrost method 0 3 0 Num
2: Time start, Evap T stop
3: Evap T start , Evap T stop
Defrost terminate temperature 0 50 5 °C
Defrost start temperature -25 0 -10 °C
Drip-off time 0 1800 0 Sec
Minimum defrost time 0 3600 900 Sec
Maximum defrost time 0 7200 1800 Sec
Minimum defrost interval 0 720 360 Min
Maximum defrost interval 0 2160 720 Min
Fan on during defrost Disable Enable Disable
Hot-gas defrost Disable Enable Disable
Timer reset on cutout Disable Enable Disable
Fan Fan start delay 0 1800 0 Sec
Fan stop delay 0 1800 0 Sec
Fan stop on cutout Disable Enable Disable
Blocked condenser Condenser warning temperature 50 85 70 °C
(optional) Condenser stop temperature 50 85 80 °C
Condenser watch Disable Enable Disable
Voltage protection Minimum cut-in voltage 80 210 185 Vrms
Voltage threshold 0 20 15 Vrms
Maximum cut-in voltage 130 264 260 Vrms
Voltage protection Disable Enable Disable
Miscellaneous Factory test 0 65535 0 Boolean
D0: Comp relay
D1: Fan relay
D2: Heater relay
D6: LED 1/10 blinking
D7: LED _ blinking
D15: Factory test
0: Epcos -100 100 Epcos Num
Sensor Type % of 1/4 period
1: Shibuara Zero-cross switching 0
Thermostat ID low D0-32 0 232 0 Num
Typenumber 0 10000 0 Num
D14-15 group number
D0-13 number
SW version 0 999 100
Zero switch Disable Enable Disable
Stop function Disable Enable Disable
Remote display Fahrenheit in display Disable Enable Disable
Decimal point Disable Enable Enable
Boolean
Show setpoint Disable Enable Disable
Display lock at defrost Disable Enable Disable
Remote sensor offset -10 10 0
Remote sensor deviation -10 10
Remote sample time 0 100 10
Remote display lock 0 1440 0 Min

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 4


Electronic thermostat control, type ETC 1H

Variants
Figure 1: Temperature cut-out

80G8133
Danfoss
Warm
cut-out

Cold
Default differential
cut-out
Cold
cut-out

In order to optimize the efficiency and ensure the reliability of the Danfoss products in your specific applications
and systems, always contact Danfoss prior to initiating the use of any Danfoss products.

• You can have the ETC1H with optional 2 or 3 relays, for controlling heaters, fans etc.
• You can have the ETC1H with standard software or optionally with special customized software for optimized
functionality. Please contact Danfoss regarding this.

Danfoss does not accept any responsibility for ETCs placed in environments outside our design specifications. Use of
the ETCs in such cases must be verified via relevant field-tests, and always remains the responsibility of the buyer.

Figure 2: Temperature differential chart

Temperature

80G8134
Danfoss
Warm differential
compressor

Compressor
cutout warm Cold differential
position compressor

Compressor
cutout cold
position
Warm differential
heat

Cold differential
heat
Heat cutin warm
position Heat cutin cold
position

Warm Default Cold Knob position


position position position

Dual band control of compressor and cabinet heater for outdoor bottle coolers placed in cold environment.

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 5


Electronic thermostat control, type ETC 1H

Dimensions and Mounting


Figure 3: Dimensions and Mounting

80G8135
Danfoss
The controls can be mounted using the nut shown or it can be mounted using 2 screws type EJOT DURO-PT dia. 3 ×
7 mm.

 WARNING:
By using screw types different than the above mentioned, there is a risk of short circuiting the line potential.

 NOTE:
All Danfoss knobs have been designed to sit flush against the housing, relieving the load on the spindle arm.
Maximum mounting force of knob: 60 N. Whenever using non-Danfoss knobs, please ensure that they are mounted
as described above and that the maximum mounting force of knob: 60 N is not exceeded.

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 6


Electronic thermostat control, type ETC 1H

Ordering

Table 4: Ordering for ETC-1H


Description Code number Comment
ETC 1H1 (120 V/ 240 V) 077F1396/99
ETC 1H2 (120 V/ 240 V) 077F1395/98 Project specific
ETC 1H3 (120 V/ 240 V) 077F1394/97
Black knob 077F8562
Mechanical options
Washer, Black, White print 0-9, I-Pack 077F8577

Table 5: Ordering for sensors


Description Cable length Port Code
Cabinet sensor(1) 470 S1 077F8751
Cabinet sensor(1) 1.0 S1 077F8757
Cabinet sensor(1) 1.5 S1 077F8761
Cabinet sensor(1) 2.0 S1 077F8765
Cabinet sensor(1) 2.5 S1 077F8767
Cabinet sensor(1) 3.0 S1 077F8769
Cabinet sensor(1) 3.5 S1 077F8723
Cabinet sensor(1) 6.0 S1 080G2019
Evaporator sensor(2) 1.0 S2 077F8786
Evaporator sensor(2) 1.5 S2 077F8790
Evaporator sensor(2) 2.0 S2 077F8794
Evaporator sensor(2) 3.0 S2 077F8798
Evaporator sensor(2) 6.0 S2 080G2029
Condenser sensor(3) 1.0 S3 077F8756
Condenser sensor(3) 1.5 S3 077F8760
Condenser sensor(3) 3.0 S3 077F8768

(1)
NTC temp sensor w/o color marking Typical cabinet temperature sensor (depending on assignment).
(2)
NTC temperature sensor with 2'' color marking Typical evaporator temperature sensor (depending on assignment).
(3)
NTC temperature sensor with 1'' color marking Typical condenser temperature sensor (depending on assignment).

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 7


Electronic thermostat control, type ETC 1H

Certificates, declarations, and approvals

The list contains all certificates, declarations, and approvals for this product type. Individual code number may have
some or all of these approvals, and certain local approvals may not appear on the list.

Some approvals may change over time. You can check the most current status at danfoss.com or contact your local
Danfoss representative if you have any questions.

Table 6: Certificates, declarations, and approvals


Regulatory and Compliance Directive Standards Country
Electrical Safety (Class I & Class II equipment) Low Voltage Directive: 2014/35/EU EN 60730-1:2000 +A12+A13+A1+A14+A16+A2 Europe
Electrical Safety (Class I & Class II equipment) Low Voltage Directive: 2014/35/EU EN 60730 2-9 : 2010 Europe
Electrical Safety (Class I & Class II equipment) - GB 14536.1:2008, GB 14536.10:2008 China
Electrical Safety (Class I & Class II equipment) - UL 60730-1, UL 60730 2-9 US
Electrical Safety (Class I & Class II equipment) - CAN/CSA-E60730-1, CAN/CSA-E60730 2-9 Canada
Electrical Safety (Class I & Class II equipment) - CU TR 004/2011 Eurasia
Electromagnetic Compatibility EMC Directive: 2014/30/EU EN 61000 6-2:2005, EN61000 6-3:2007 +A1:2011 Europe
RoHS RoHS Directive: 2011/65/EU & 2015/863/EU EN 50581:2012, EN IEC 63000 : 2018 Europe
Food Safety - NSF/ANSI-2 US
Approved for use in Flammable Refrigerants - EN 60335 2-89: 2010 Annex BB, EN 60335 2-24: Europe
2010 Annex CC
Approved for use in Flammable Refrigerants - UL 471, UL 60335 2-24, UL 60079-15 ed.4 US
Enclosure material flammable class - UL 94 US

Certification and Manufacturer Declarations on CE, C-UL-US, CQC, UA , EAC, ENEC, NSF, S Mark, RoHS
Conformity

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 8


Online support

Danfoss offers a wide range of support along with our products, including digital product information, software,
mobile apps, and expert guidance. See the possibilities below.

The Danfoss Product Store


The Danfoss Product Store is your one-stop shop for everything product related—no matter where
you are in the world or what area of the cooling industry you work in. Get quick access to essential
information like product specs, code numbers, technical documentation, certifications, accessories,
and more.
Start browsing at store.danfoss.com.

Find technical documentation


Find the technical documentation you need to get your project up and running. Get direct access to
our official collection of data sheets, certificates and declarations, manuals and guides, 3D models
and drawings, case stories, brochures, and much more.

Start searching now at www.danfoss.com/en/service-and-support/documentation.

Danfoss Learning
Danfoss Learning is a free online learning platform. It features courses and materials specifically
designed to help engineers, installers, service technicians, and wholesalers better understand the
products, applications, industry topics, and trends that will help you do your job better.

Create your Danfoss Learning account for free at www.danfoss.com/en/service-and-support/learning.

Get local information and support


Local Danfoss websites are the main sources for help and information about our company and
products. Find product availability, get the latest regional news, or connect with a nearby expert—all
in your own language.

Find your local Danfoss website here: www.danfoss.com/en/choose-region.

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its
products without notice. This also applies to products already on order provided that such alterations can be made without subsequential
changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and
the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

© Danfoss | Climate Solutions | 2021.03 AI215986425643en-000501 | 9