Final Inspection Report
Supplier Code : Customer : Kirloskar Pneumatic Co. Pvt. Ltd.
Supplier Name:SPARK ENGINEERING COMPANY Part Name : AIR/OIL SEP. WITH TOP COVER ASSLY(R2) Quantity : 05 nos. Challan No : Date :24/08/2024
Part No. :271.01.430.50. Rev.No. : R Po No: Report No.:
Observations with Sr.No.
Sr. Specified
Inspection Parameter Instrument Used S.N.-1 S.N.-2 S.N.-3 S.N.-4 S.N.-5
No. value in mm REMARK
SEAOS-6178 SEAOS-6179 SEAOS-6180 SEAOS-6181 SEAOS-6182
1 Total Length Aos 597 ±2 Vernier 596 596 595 596 596
Bottom Mountng C.D. 193*221 +/-0.5 Vernier 193*221 193*221 193*221 193*221 193*221
Thread plug
2 Threading 1/2"BSP OK OK OK OK OK
gauge
Thread plug
3 Threading 3/4"BSP OK OK OK OK OK
gauge
Thread plug
4 Threading (2x) 1"BSP OK OK OK OK OK
gauge
Thread plug
5 Threading 3/8"BSP OK OK OK OK OK
gauge
Thread plug
6 Threading 1/4"BSP OK OK OK OK OK
gauge
Thread plug
7 Threading (8x) M12*1.75*12 deep OK OK OK OK OK
gauge&Vernier
8 Shell overall dimension OD 273*L597±2 Measuring tape OD 273*L428 OD 273*L428 OD 273*L428 OD 273*L428 OD 273*L428
9 Oil level indicator CD from bottom(N5) 293+/-2.0 Measuring tape 294 294 291 292 294
Air oil inlet Nozzle Distance from
10 422+/-2.0 Measuring tape 423 421 421 422 421
bottom(N1)
Oil filler elbow face Distance from
11 337+/-2.0 Measuring tape 336 335 338 336 336
bottom(N4)
12 Oil Filter Bracket CD 20 +/-0.2 Vernier 20 20 20 20 20
13 Oil Filter Bracket CD 20 +/-0.2 Vernier 20 20 20 20 20
14 Oil outlet elbow CD from bottom(N2) 225+/-2.0 Measuring tape 224 224 223 224 223
Con. With dia. 10.5,pro.
15 M8 Weld Nut Visual Inspection Visually inspection found ok
Welded & free from paint
Fitment at specified
16 Nozzle N1-N7 Visual Inspection Visually inspection found ok
location
No tool marks,No
17 Top cover face resting on shell Visual Inspection checked visually & found ok
damage
Perp. To threding (No
18 All Threading top face gap after fitment of resp. Visual Inspection Visually inspection found ok
fitting)
Should be
19 All openings Visual Inspection Visually inspection found ok
plugged/covered
20 Hydrotest at 21 kg/cm2 for 30min. No Leakage Test Rig. Testing done at 21 kg/cm2 for 30min no leakage observed
No dust,dirt & foreign
21 Tank Area from inside Visual Inspection Visually inspection found ok
particles inside tank
22 Paintng (Inner surface of shell) castrol oil Visual Inspection Visually inspection found ok
No any foreign
patticles,loose welding
23 Cleaning & flushing material,spatters allowed Visual Inspection checked visually & found satisfactory
inside tank.To be removed
properly.
24 All other not mentioned dimensions & geometrical parameters has to be maintained & ensured.
Note : 1. For Lot size less than 10 Nos, record of all parts should be mentioned in PDIR . 2. For Lot size more than 10 Nos, record of minimum 10
parts should be mentioned in PDIR & Inspected parts should be separatly identified.
For Customer For Supplier
Accepted Rejected Rework
TC Enclosed Chemical / Physical/ Magnaflux / U.T. / Hardness / Performance / Hydro Test
GRR No. GRR Date GRR Location
Checked By Approved By
Format No:
Rev. No. - 00