Model:SEPLOS 16S100A
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
1
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
1. Scope of application
This product fully supports the acquisition of eight-sixteen cells in series; eight cells in series only
need to change the hardware power threshold and remove the high row plug; The fifteen series
and sixteen series are fully compatible. It is only necessary to change the cell sampling line fifteen
series and sixteen series together, and configure the number of series and total voltage
protection parameters through the upper computer.BMS can match multiple inverter
manufacturers through the upper computer setting protocol, with pre-charging function. BMS
has multi-layer protection functions, including a series of protection and recovery functions such
as Individual over voltage/under voltage, total voltage under voltage/over voltage,
charge-discharge over current, charge-discharge secondary over current, charge-discharge high
temperature, charge-discharge low temperature and short circuit.The SOC, SOH and total
discharge capacity can be accurately calculated according to the characteristics of the cell.
Parallel communication through RS485 and data monitoring through upper computer software.It
can communicate with the inverter through CAN/485 .
2
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
4. Assembly
Length * width=300mm*100mm
3
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
4
SEPLOS SMART BMS3.0 SPECIFICATION Battery Drop External Dry
WWW.SEPLOS.COM
B+ out switch contact
Export P-
LCD
screen
Heat Harness
A
Harness B
Battery B-
Dialing
address
(NC)
Inverter CAN/485
LED Light Internal 485 On/Off
communication
communication
5
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
6
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Assembly method of BMS and cell module : First battery B- ——Sample line A——Sample line
B——Battery B+(Battery B+Line use M3 screw,Recommended use 16AWG harness,Battery
B+The main reason is that the power supply can not meet the large current ) ——output
P-Negative pole of load or charger——output P+Load or charger positive pole
4.4 communication
7
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Select the corresponding port and baud rate for BMS internal communication 19200
BMS has the function of automatic address assignment without dialing (the dialing switch
reserved on BMS is only a decoration to be compatible with the original battery case port design,
and the dialing address can be optional without affecting the automatic address assignment of
BMS), and the normal network cable can be used when the machine is connected.
8
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
1.Turn on the upper computer DevBMSStudio.exe 2.Click to set serial port parameters,
software corresponding port and baud rate 19200, and click
to start
3.There is data on the interface to prove that 4.Select login (password: 000000) to set some
there is no data. Please check whether the functional settings such as operational
communication line is connected properly parameters, inverter protocol switching, etc.
(terminal customer operation is not
recommended)
9
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
1.The customer needs to confirm with the BMS 2.The basic parameter settings can be
manufacturer before changing the parameters downloaded according to the customer's needs.
that the corresponding alarm and protection in The parameters can be divided into separate
the parameters are related to each other, and the download and full download (separate download
non-professional personnel should not operate can only be used for testing, and the parameters
to change the parameters (charging and downloaded separately will not be protected after
discharging status is not allowed to change the BMS shutdown)
parameters)
3.The function switch settings can be turned on 4.The customer can also configure the parameters
and off according to the customer's choice. The through the BMS manufacturer, load the
function switch can be divided into separate parameters and download all
download and full download (separate download
can only be used for testing, and the parameters
downloaded separately after BMS shutdown are
discarded without protection)
10
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Other settings of the upper computer include the BMS is divided into BMS-SN (SN produced by the
corresponding manufacturer and communication manufacturer) and PACK-SN (SN produced by the
mode of the inverter. Please set the reserved PACK factory)
corresponding protocol according to the current
inverter
11
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Click to start the upgrade software, and the Select the corresponding serial port, the baud
upgrade software will pop up rate is 19200, the stop bit is on, click Browse to
find the corresponding upgrade program, and
finally click Download
12
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
power indication
Charge
Over voltage alarm Green OFF According to Maximum LED flashing 2
power indication
power indication
power indication
Discharge
Alarm ON3 ON3 According to
power indication
Under voltage protection OFF OFF OFF Stop discharging and shutdown
protection
power indication
power indication
discharging
13
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Capacity indication
Statue Charge Discharge
Capacity indicator L4● L3● L2● L1● L4● L3● L2● L1●
0~25% OFF OFF OFF Blink2 OFF OFF OFF Green
Quantity of 25~50% OFF OFF Blink2 Green OFF OFF Green Green
electricity% 50~75% OFF Blink2 Green Green OFF Green Green Green
75~100% Blink2 Green Green Green Green Green Green Green
Running indicator● Green Blink3
7. Parameter specification
14
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
15
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
16
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
recovery protection~low
temperature
recovery
Charging under Configurable -10℃ -15℃~Low
temperature temperature
protection alarm
Discharge high ON Configurable 50℃ 45℃~High
temperature temperature
recovery alarm
Discharge high Configurable 55℃ High
temperature alarm temperature
recovery~over
temperature
protection
Discharge ON Configurable 55℃ High
over-temperature temperature
recovery recovery~over
Discharge temperature
temperature protection
Discharge Configurable 60℃ High
over-temperature temperature
protection alarm~65℃
Discharge ON Configurable 3℃ Low temperature
low-temperature alarm~10℃
recovery
Discharge low Configurable -10℃ Under
temperature alarm temperature
protection~low
temperature
recovery
Discharge under ON Configurable 0℃ Under
temperature temperature
recovery protection~low
temperature
recovery
Discharge under Configurable -15℃ -15℃~Low
temperature temperature
protection alarm
17
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
18
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
SOC parameter
SOC Low recovery ON Configurable 15% low alarm of SOC
SOC Low alarm Configurable 10% is only for
prompt, without
SOC any action
SOC Protection OFF Configurable 7% SOC low
recovery protection stops
SOC Low protection Configurable 5% discharging, and
is off by default
Balancing parameter
Balancing opening ON Configurable 3.4V Equalization is
voltage divided into
Balancing opening Configurable 0.05V standby
differential pressure equalization and
Balancing Balancing end Configurable 0.03V charging
differential pressure equalization,
which can only
be equalized
after the
19
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
opening
conditions are
met
Balancing high ON Configurable 50℃ The temperature
temperature is too high or too
prohibition low, and the
Balancing low Configurable 0℃ BMS does not
temperature allow
prohibition equalization
Static equalization ON Configurable 10H The equilibrium
timing continues to
reach the set
time
Pre-charge parameter
Completion rate of ON / 10% This function is
short circuit pre-charge not allowed to
Normal pre-charge / 80% be set. Judge the
completion rate pre-charge and
Pre-charge Abnormal pre-charge / 20% short circuit
completion rate conditions
Pre-charge timeout ON Configurable 3S Duration after
opening
pre-charge
20
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Heat parameter
Heat Cell heating stop OFF Configurable 10℃ Charger online
Cell heating on Configurable 0℃ condition,
heating only
after reaching
the set
temperature
8. Function description
8.1 ON/OFF
Function Instruction
ON/OFF Press the ON/OFF key for more than 1 s, the LED lights turn on
from the capacity indicator light in turn, and then release, and
the BMS enters the power-on state
Press the ON/OFF key for more than 3s, the LED lights turn on
OFF/Dormant from the running light in turn, and then release, and the BMS
enters the shutdown state
Function Instruction
Voltage detection The detection accuracy of cell voltage is ± 10mV at 0~45 ℃
and ± 30mV at - 20~70 ℃.
Individual Over When any section of the cell reaches the Individual over voltage
voltage protection protection value, BMS closes the charging tube and stops
charging; When the voltage reaches the recovery value or the
21
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Function instruction
Current detection With charge and discharge current detection, the charge
current is displayed as positive current, and the discharge
current is displayed as negative current; The current sampling
accuracy can reach ± 2% at normal temperature.
Charging over current When there is no charging current limiting function, the current
protection reaches the charging over current protection value and reaches
the delay time; BMS closes the charging tube and stops
charging; When the BMS reaches the recovery delay, re-detect
the external charger current or discharge (current above 3A) to
remove the charging over current protection.
Charging secondary When there is no charging current limiting function, the current
over current reaches the charging secondary over current protection value
protection and reaches the delay time; BMS closes the charging tube and
stops charging; When the BMS reaches the recovery delay,
re-detect the current of the external charger or discharge
(current above 3A) to remove the charging secondary over
current protection.
Discharge over The current reaches the discharge over current protection value
current protection and reaches the delay time; BMS closes the discharge tube and
stops discharging; When the BMS reaches the recovery delay,
re-detect the external load current or charge (current above 3A)
to remove the discharge over current protection.
22
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Discharge secondary The current reaches the discharge secondary over current
over current protection value and reaches the delay time; BMS closes the
protection discharge tube and stops discharging; When the BMS reaches
the recovery delay, re-detect the external load current or charge
(current above 3A) to remove the discharge secondary over
current protection.
Function Instruction
Temperature Have the temperature detection function of 4 cells, 1
detection environment and 1 MOS tube, and the temperature sampling
accuracy can reach ± 2 at normal temperature; The core
temperature sensor adopts 10K/3435/NTC thermistor.
Charging Regardless of charging and discharging, when the temperature
over-temperature reaches the charging over-temperature protection value, close
protection the charging tube and stop charging; If the temperature is less
than the over-temperature recovery value, the BMS will resume
charging.
Charging under Regardless of charging and discharging, when the temperature
temperature reaches the charging under temperature protection value, close
protection the charging tube and stop charging; The BMS will resume
charging when the temperature is greater than the temperature
recovery value
Discharge Regardless of charging and discharging, when the temperature
over-temperature reaches the discharge over-temperature protection value, close
protection the discharge tube and stop discharging; When the temperature
is less than the over-temperature recovery value, BMS will
resume discharging. (The charging temperature is also
protected after the general discharge temperature protection,
and the charging temperature setting value is lower than the
discharge temperature setting value)
Discharge under Regardless of charging and discharging, when the temperature
temperature reaches the discharge under temperature protection value,
protection close the discharge tube and stop discharging; The BMS will
resume discharging when the temperature is greater than the
temperature recovery value. (The charging temperature is also
protected after the general discharge temperature protection,
and the charging temperature setting value is higher than the
discharge temperature setting value)
Ambient over/under The NTC chip on the PCB board specially detects the internal
temperature temperature of the case, reaches the
23
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Function Instruction
Standby balance BMS adopts energy consumption equalization circuit; When the
equalizing opening voltage reaches the set value and the
opening differential pressure, the equalizing is started; The
default starting voltage is 3.4V, the equalizing current is ≥
50mA, and the equalizing resistance temperature is not more
than 50 ℃.
Charge balance BMS adopts energy consumption equalization circuit; Under the
charging state, when the equalizing opening voltage reaches the
set value and the opening differential pressure, the equalizing is
started; The default starting voltage is 3.4V, the equalizing
current is ≥ 50mA, and the equalizing resistance temperature
is not more than 50 ℃.
High temperature The BMS stops equalizing when the temperature reaches the
prohibited balance equalizing high temperature setting.
Balance timeout The BMS stops balancing from the start of balancing to the
setting time.
Function Instruction
Main heating The maximum temperature rise of BMS shall not exceed 70 ℃
components when the battery pack is discharged horizontally at the rated
discharge current under the temperature of 25 ℃; In the
environment with a temperature of 55 ℃, the battery pack is
tested flat and discharged at 0.1C. BMS MOSFET is not
protected.
24
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
8.7 Consumption
8.8 Storage
Function Instruction
Historical data storage State conversion, single battery voltage, total battery voltage,
charging/discharging current, temperature, etc; Record in
year/month/day/hour/minute/second, with storage capacity not
less than 500 records; The principle of first in first out is
adopted, and the stored content can be read through the
monitoring interface.
8.9 Pre-charge
Function Instruction
pre-charge in turning When BMS is turned off, press the key to start up, and the
on pre-charge function will be activated instantly to avoid short
circuit protection caused by capacitive load.
Pre-charge in standby BMS is suddenly connected to the capacitive load in standby
mode mode. BMS detects that it is the capacitive load to pre-charge
to avoid triggering the short-circuit protection.
25
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Function Instruction
Automatic address The automatic address assignment of the parallel machine must
assignment be connected to the internal communication line according to
the parallel machine communication wiring method, otherwise
the address cannot be automatically assigned. Please check the
parallel machine communication method above.
Function Instruction
One-button off The host sends a command to the slave to shut down. The
shutdown method is to shut down the host manually. The host
will issue a command to the slave. The host will shut down after
the slave is shut down step by step (manual shutdown of the
slave is unable to achieve the one-button shutdown function).
One-button on After any one is powered on, other groups of BMS will be
activated gradually.
26
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Function Instruction
Control release The release is placed on the P-terminal, and the BMS can not
disconnection output close the charge and discharge in case of failure protection. The
after BMS failure BMS will give the release voltage to disconnect the release, so
that the BMS can not be charged and discharged externally
Function Instruction
BMS leads out a self-locking The BMS itself comes with a reset switch, which is
switch inconvenient for customers to turn on/off inside the
chassis; BMS specially opened an external switch with
12V power supply, which is convenient for customers to
switch on and off
27
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
Function Instruction
2-way dry contact BMS is equipped with 2-way dry contact function, and the
principle design uses the wet-joint passive scheme; One
channel is in alarm state and one channel is in protection state
Function Instruction
LCD screen BMS is equipped with LCD screen function. Now it is required to
turn on the LCD display function through the parameter
function switch of the upper computer, and connect the display
screen to the BMS LCD screen interface for use; The LCD screen
can switch the inverter protocol. Press the Enter key twice after
the corresponding protocol, and the protocol will switch
normally
28
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
29
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM
2022.10.25 V1.0 初稿
30