SEPLOS SMART BMS 3.

16S100ALithium battery management system specification

Model:SEPLOS 16S100A
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

1. Scope of application .............................................................................................................................. 2


2. Normative reference scope .................................................................................................................... 2
3. BMS Naming rules ................................................................................................................................ 3
4. Assembly ............................................................................................................................................... 3
4.1 Dimensional drawing ............................................................................................................... 3
4.2 Electrical characteristics ...........................................................................................................4
4.3 Installation method ...................................................................................................................4
4.3.1 BMS Interface definition .............................................................................................. 4
4.3.2 Sample harness definition .............................................................................................5
4.3.3 BMS and battery assembly method .............................................................................. 7
4.4 communication .........................................................................................................................7
4.4.1 Matching inverter communication ................................................................................7
4.4.2 Internal communication ................................................................................................ 8
4.5 Parallel communication ............................................................................................................8
5. Operating instruction of upper computer .............................................................................................. 9
5.1 Connection setting of upper computer ..................................................................................... 9
5.2 Set parameters ........................................................................................................................ 10
5.3 Inverter matching setting ........................................................................................................11
5.4 Data record ............................................................................................................................. 11
5.5 Upgrade procedure ................................................................................................................. 12
6. LED light indication ............................................................................................................................ 13
7. Parameter specification ....................................................................................................................... 14
8. Function description ............................................................................................................................ 21
8.1 ON/OFF ..................................................................................................................................21
8.2 Voltage detection and protection ........................................................................................... 21
8.3 Current detection and protection ............................................................................................22
8.4 Temperature detection and protection ....................................................................................23
8.5 Balancing function ................................................................................................................. 24
8.6 Temperature rise .....................................................................................................................24
8.7 Consumption .......................................................................................................................... 25
8.8 Storage ....................................................................................................................................25
8.9 Pre-charge .............................................................................................................................. 25
8.10 Automatic dialing .................................................................................................................26
8.11 One-button switch ................................................................................................................ 26
8.12 Inverter matching protocol definition .................................................................................. 26
8.13 Release control (optional) .................................................................................................... 27
8.14 External switch (optional) .................................................................................................... 27
8.15 Dry contact (optional) .......................................................................................................... 28
8.16 LCD screen (optional) ..........................................................................................................28
9. Precautions for use .............................................................................................................................. 29
10. Version change .................................................................................................................................. 30

1
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

1. Scope of application
This product fully supports the acquisition of eight-sixteen cells in series; eight cells in series only
need to change the hardware power threshold and remove the high row plug; The fifteen series
and sixteen series are fully compatible. It is only necessary to change the cell sampling line fifteen
series and sixteen series together, and configure the number of series and total voltage
protection parameters through the upper computer.BMS can match multiple inverter
manufacturers through the upper computer setting protocol, with pre-charging function. BMS
has multi-layer protection functions, including a series of protection and recovery functions such
as Individual over voltage/under voltage, total voltage under voltage/over voltage,
charge-discharge over current, charge-discharge secondary over current, charge-discharge high
temperature, charge-discharge low temperature and short circuit.The SOC, SOH and total
discharge capacity can be accurately calculated according to the characteristics of the cell.
Parallel communication through RS485 and data monitoring through upper computer software.It
can communicate with the inverter through CAN/485 .

2. Normative reference scope


The following documents are indispensable for the application of this document. For dated
reference files, only the dated version applies to this file. For undated reference documents, the
latest version (including all amendments) applies to this document.
GB/T 191 Pictorial marks for packaging, storage and
transportation.
GB/T 2408-2008 Plastics Determination of combustion
performance
Horizontal and vertical methods
EN 61000-6 EMC (electromagnetic compatibility) test
standard for
electronic and electrical products
GB/T 17626.5-2008 Electromagnetic compatibility Test and
measurement
technology Surge (impact) immunity test
GB/T 17626.2-2006 Electromagnetic compatibility Test and
measurement technology Electrostatic
discharge immunity test
YD/T 2344.1—2011 Lithium iron phosphate battery pack for
communication
Part 1: Integrated battery pack

2
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

YD/T 2344.2—2015 Lithium iron phosphate battery pack for


communication
Part 2:Discrete battery pack
YD/T 1363.3 Centralized monitoring and management
system for power
supply,air conditioning and environment of
communication
bureau (station) Part 3:Front-end smart
device protocol
GB/T 36558-2018 General technology of energy storage system

3. BMS Naming rules


Category Name Name definition
Model SEPLOS16S100A-TEST01  SEPLOS : Abbreviation of company
name
 16S:Number of electric cell strings
 100A:Charge and discharge current
 TST : Abbreviation of customer
company
 01:Customer model
QR code content TEST01-20221026-1027-0001  TEST01:Customer company name and
model
 20221026:Order date
 1027:date of manufacture
 0001:Production serial number

4. Assembly

4.1 Dimensional drawing

Length * width=300mm*100mm

3
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

4.2 Electrical characteristics

Item Min Max Type Unit


working voltage 40 59 48 V
Charging voltage 48 60 54 V
working temperature -20 70 25 ℃
Storage temperature -40 85 25 ℃
Ambient humidity 10 85 - %
Charge and discharge
- 110 100 A
current
Internal resistance <2 mΩ

4.3 Installation method

4.3.1 BMS Interface definition

4
SEPLOS SMART BMS3.0 SPECIFICATION Battery Drop External Dry
WWW.SEPLOS.COM
B+ out switch contact
Export P-
LCD
screen

Heat Harness
A

Harness B

Battery B-

Dialing
address
(NC)

Inverter CAN/485
LED Light Internal 485 On/Off
communication
communication

4.3.2 Sample harness definition

Harness A (black row plug)


BMS Wiring definition Cell wiring definition
CELL1- Connected to the negative pole of the first battery
CELL1+ Connected to the positive pole of the first battery
CELL2+ Connected to the positive pole of the second battery
CELL3+ Connected to the positive pole of the third battery
CELL4+ Connected to the positive pole of the fourth battery
NTC1+ Connected to temperature sensorNTC1
NTC1- Connected to temperature sensorNTC1
CELL5+ Connected to the positive pole of the fifth battery
CELL6+ Connected to the positive pole of the sixth battery
CELL7+ Connected to the positive pole of the seventh battery
CELL8+ Connected to the positive pole of the eighth battery
NTC2+ Connected to temperature sensorNTC2
NTC2- Connected to temperature sensorNTC2

5
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

Harness B(white row plug)


BMS Wiring Cell wiring definition
definition
CELL9- Connected to the negative pole of the ninth battery
CELL9+ Connected to the positive pole of the ninth battery
CELL10+ Connected to the positive pole of the tenth battery
CELL11+ Connected to the positive pole of the eleventh battery
CELL12+ Connected to the positive pole of the twelfth battery
NTC3+ Connected to temperature sensorNTC3
NTC3- Connected to temperature sensorNTC3
CELL13+ Connected to the positive pole of the thirteenth battery
CELL14+ Connected to the positive pole of the fourteenth battery
CELL15+ Connected to the positive pole of the fifteenth battery
CELL16+ Connected to the positive pole of the sixteenth battery
NTC4+ Connected to temperature sensorNTC4
NTC4- Connected to temperature sensorNTC4

Actual wiring mode of sampling line and cell(As shown below)

6
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

4.3.3 BMS and battery assembly method

Assembly method of BMS and cell module : First battery B- ——Sample line A——Sample line
B——Battery B+(Battery B+Line use M3 screw,Recommended use 16AWG harness,Battery
B+The main reason is that the power supply can not meet the large current ) ——output
P-Negative pole of load or charger——output P+Load or charger positive pole

4.4 communication

4.4.1 Matching inverter communication

Define the corresponding BMS communication interface according to the communication


interface of each inverter ; The definition of the special inverter communication port is
inconsistent with that of the BMS communication port. You need to make your own network
cable. If you use the conventional network cable, the BMS may automatically start or shut down;
Generally, use the conventional network cable to communicate.

7
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

4.4.2 Internal communication

Select the corresponding port and baud rate for BMS internal communication 19200

4.5 Parallel communication

BMS has the function of automatic address assignment without dialing (the dialing switch
reserved on BMS is only a decoration to be compatible with the original battery case port design,
and the dialing address can be optional without affecting the automatic address assignment of
BMS), and the normal network cable can be used when the machine is connected.

8
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

5. Operating instruction of upper computer

5.1 Connection setting of upper computer

1.Turn on the upper computer DevBMSStudio.exe 2.Click to set serial port parameters,
software corresponding port and baud rate 19200, and click
to start

3.There is data on the interface to prove that 4.Select login (password: 000000) to set some
there is no data. Please check whether the functional settings such as operational
communication line is connected properly parameters, inverter protocol switching, etc.
(terminal customer operation is not
recommended)

9
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

5.2 Set parameters

1.The customer needs to confirm with the BMS 2.The basic parameter settings can be
manufacturer before changing the parameters downloaded according to the customer's needs.
that the corresponding alarm and protection in The parameters can be divided into separate
the parameters are related to each other, and the download and full download (separate download
non-professional personnel should not operate can only be used for testing, and the parameters
to change the parameters (charging and downloaded separately will not be protected after
discharging status is not allowed to change the BMS shutdown)
parameters)

3.The function switch settings can be turned on 4.The customer can also configure the parameters
and off according to the customer's choice. The through the BMS manufacturer, load the
function switch can be divided into separate parameters and download all
download and full download (separate download
can only be used for testing, and the parameters
downloaded separately after BMS shutdown are
discarded without protection)

10
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

5.3 Inverter matching setting

Other settings of the upper computer include the BMS is divided into BMS-SN (SN produced by the
corresponding manufacturer and communication manufacturer) and PACK-SN (SN produced by the
mode of the inverter. Please set the reserved PACK factory)
corresponding protocol according to the current
inverter

5.4 Data record

Real-time data Historical data


PACK factory monitors BMS data during charging Need to view the original status, alarm/protection
and discharging cycle, and can enable real-time data, and you can read all the stored data of BMS
recording function, save as and keep it in current through historical data
computer

11
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

5.5 Upgrade procedure

Click to start the upgrade software, and the Select the corresponding serial port, the baud
upgrade software will pop up rate is 19200, the stop bit is on, click Browse to
find the corresponding upgrade program, and
finally click Download

12
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

6. LED light indication


LED operation indication status
status Normal/alarm/protection RUN ALN Power Instruction
indicator
LED
● ● ● ● ● ●
Shutdown Dormancy OFF OFF OFF Total extinction

Normal ON 1 OFF OFF Stand by statue


Stand-by
ALM and RUN lights flash
Alarm ON 1 ON 1 OFF
synchronously 1

Normal Green OFF According to Maximum LED flashing 2

power indication
Charge
Over voltage alarm Green OFF According to Maximum LED flashing 2

power indication

Over current alarm Green ON 2 According to Maximum LED flashing 2

power indication

Over voltage protection ON 1 OFF OFF Switch to standby mode

Normal ON 3 OFF According to According to the electric quantity

power indication
Discharge
Alarm ON3 ON3 According to

power indication

Under voltage protection OFF OFF OFF Stop discharging and shutdown

Over current and short circuit OFF Red OFF

protection

Charging alarm Green ON2 According to

power indication

Temperature Discharge alarm ON 3 ON 3 According to

power indication

Close the corresponding MOS

Protect OFF Red OFF tube when the temperature

reaches the protection value

regardless of charging and

discharging

LED Blink description


Blinking state ON OFF
Blink1 0.25S 3.75S
Blink2 0.5S 0.5S
Blink3 0.5S 1.5S

13
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

Capacity indication
Statue Charge Discharge
Capacity indicator L4● L3● L2● L1● L4● L3● L2● L1●
0~25% OFF OFF OFF Blink2 OFF OFF OFF Green
Quantity of 25~50% OFF OFF Blink2 Green OFF OFF Green Green
electricity% 50~75% OFF Blink2 Green Green OFF Green Green Green
75~100% Blink2 Green Green Green Green Green Green Green
Running indicator● Green Blink3

7. Parameter specification

Individual over /under voltage parameter

Item Default Configurable Set Remarks


Range (acceptable range
15S/16S)
Individual Individual high voltage ON Configurable 3.4V 3.37V~High
over voltage recovery voltage alarm
Individual high voltage Configurable 3.5V High voltage
alarm recovery~Over
voltage
protection
Individual Over voltage ON Configurable 3.4V High voltage
recovery recovery~Over
voltage
protection
Individual Over voltage Configurable 3.65 High voltage
protection V alarm~3.85V

Over voltage recovery Individual voltage recovery or discharge current>3A


conditions
Individual Low voltage ON Configurable 3.1V Low voltage
recovery alarm~3.1V
Individual Low voltage Configurable 2.9V Low voltage
alarm recovery~Low
voltage recovery
Individual Individual Under ON Configurable 3.1V Under voltage
Under voltage recovery protection~Low
voltage voltage recovery

Individual Under Configurable 2.7V 2.5V~Low voltage

14
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

voltage protection recovery


Under voltage recovery Shutdown after under voltage protection requires
condition charging activation or key activation

Total pressure over /under pressure parameter


Total Total pressure high ON Configurable 54V 51V~High
pressure pressure recovery voltage alarm
over Total pressure high Configurable 56V High voltage
pressure pressure alarm recovery~Over
voltage
protection
Total pressure over ON Configurable 54V High voltage
voltage recovery recovery~Over
voltage
protection
Total pressure over Configurable 57.6V High voltage
voltage protection alarm~58V
Total pressure recovery Individual voltage recovery or discharge
condition current>3A
Total Total pressure low ON Configurable 48V Low voltage
pressure pressure recovery alarm~49V
under Total pressure low Configurable 46.4V Low voltage
pressure pressure alarm recovery~Low
voltage recovery
Total voltage under ON Configurable 48V Under voltage
voltage recovery protection~Low
voltage recovery
Total voltage under Configurable 43.2V 40V~Low voltage
voltage protection alarm
Under voltage recovery Shutdown after under voltage protection requires
condition charging activation or key activation

Discharge/Charging over current parameter


Charging Charging over current ON Configurable 103A Continuous
over recovery charging current
current Charging over current Configurable 105A setting according
alarm to model
Charging over current ON Configurable 110A selection
protection
Charging over current Configurable 10S 1S~10S
delay
Charging secondary ON Configurable 200A 60s automatic

15
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

over current protection recovery after


Charging secondary Configurable 30ms over current
over current delay protection
Discharge over current ON Configurable 103A Continuous
recovery charging current
Discharge over current Configurable 105A setting according
alarm to model
Discharge Discharge over current ON Configurable 110A selection
over current protection
Discharge over current Configurable 10S 1S~10S
delay
Discharge secondary ON Configurable 250A 60s automatic
over current protection recovery after
Discharge secondary Configurable 500ms over current
over current delay protection

Discharging/Charging temperature parameter


Charging High ON Configurable 47℃ 40℃~High
temperature temperature
recovery alarm
Charging high Configurable 50℃ High
temperature alarm temperature
recovery~Over
temperature
protection
Charging ON Configurable 50℃ High
over-temperature temperature
recovery recovery~Over
temperature
protection
Charging Charging Configurable 55℃ High
temperature over-temperature temperature
protection alarm~65℃
Charging ON Configurable 5℃ Low temperature
low-temperature alarm~10℃
recovery
Charging low Configurable 2℃ Under
temperature alarm temperature
protection~low
temperature
recovery
Charging under ON Configurable 0℃ Under
temperature temperature

16
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

recovery protection~low
temperature
recovery
Charging under Configurable -10℃ -15℃~Low
temperature temperature
protection alarm
Discharge high ON Configurable 50℃ 45℃~High
temperature temperature
recovery alarm
Discharge high Configurable 55℃ High
temperature alarm temperature
recovery~over
temperature
protection
Discharge ON Configurable 55℃ High
over-temperature temperature
recovery recovery~over
Discharge temperature
temperature protection
Discharge Configurable 60℃ High
over-temperature temperature
protection alarm~65℃
Discharge ON Configurable 3℃ Low temperature
low-temperature alarm~10℃
recovery
Discharge low Configurable -10℃ Under
temperature alarm temperature
protection~low
temperature
recovery
Discharge under ON Configurable 0℃ Under
temperature temperature
recovery protection~low
temperature
recovery
Discharge under Configurable -15℃ -15℃~Low
temperature temperature
protection alarm

17
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

Ambient temperature parameter


Ambient high ON Configurable 47℃ 45℃~High
temperature temperature
recovery alarm
Ambient high Configurable 50℃ High
temperature alarm temperature
recovery~over
temperature
protection
Ambient ON Configurable 55℃ High
over-temperature temperature
recovery recovery~over
temperature
Ambient protection
temperature Ambient Over Configurable 60℃ High
temperature temperature
protection alarm~65℃
Ambient ON Configurable 3℃ Low temperature
Low-temperature alarm~10℃
recovery
Ambient Low Configurable 0℃ Under
temperature alarm temperature
protection~low
temperature
recovery
Ambient Under ON Configurable 0℃ Under
temperature temperature
recovery protection~low
temperature
recovery
Ambient Under Configurable -10℃ -15℃~Low
temperature temperature
protection alarm

Power temperature parameter


Power Power high ON Configurable 90℃ High
temperature temperature alarm temperature
recovery~over
temperature
protection
Power high Configurable 85℃ 45℃~High
temperature temperature
recovery alarm

18
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

Power ON Configurable 100℃ High


over-temperature temperature
protection alarm~110℃
Power Configurable 85℃ High
over-temperature temperature
recovery recovery~over
temperature
protection

SOC parameter
SOC Low recovery ON Configurable 15% low alarm of SOC
SOC Low alarm Configurable 10% is only for
prompt, without
SOC any action
SOC Protection OFF Configurable 7% SOC low
recovery protection stops
SOC Low protection Configurable 5% discharging, and
is off by default

Cell failure parameter


Individual differential ON Configurable 500mV Differential
pressure alarm pressure alarm is
Differential pressure Configurable 300mV only a prompt,
alarm recovery without any
action.
Cell failure Individual differential OFF Configurable 1V The differential
pressure protection pressure
Differential pressure Configurable 0.5V protection is
protection recovery invalid. After the
failure, the LED
will flash
completely and
shut down

Balancing parameter
Balancing opening ON Configurable 3.4V Equalization is
voltage divided into
Balancing opening Configurable 0.05V standby
differential pressure equalization and
Balancing Balancing end Configurable 0.03V charging
differential pressure equalization,
which can only
be equalized
after the

19
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

opening
conditions are
met
Balancing high ON Configurable 50℃ The temperature
temperature is too high or too
prohibition low, and the
Balancing low Configurable 0℃ BMS does not
temperature allow
prohibition equalization
Static equalization ON Configurable 10H The equilibrium
timing continues to
reach the set
time

Active /passive current limiting parameter


Active OFF / Constant 10A
current current limit
limiting
Duration of charging ON Configurable 300S Duration after
current limit current limit
Pulse current limiting Configurable 100A Current reaches
current the limit of
Passive opening
current condition
limiting Pulse current limiting Configurable 1S Judge whether
time the pulse current
lasts and turn on
the passive
current limiting
function

Pre-charge parameter
Completion rate of ON / 10% This function is
short circuit pre-charge not allowed to
Normal pre-charge / 80% be set. Judge the
completion rate pre-charge and
Pre-charge Abnormal pre-charge / 20% short circuit
completion rate conditions
Pre-charge timeout ON Configurable 3S Duration after
opening
pre-charge

20
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

Heat parameter
Heat Cell heating stop OFF Configurable 10℃ Charger online
Cell heating on Configurable 0℃ condition,
heating only
after reaching
the set
temperature

Recommended inverter voltage and current parameter


Recommen Charge request voltage ON Configurable 57.6V BMS sends a
ded inverter Charge request current Configurable 80A request to the
voltage and Discharge request Configurable 80A inverter for
current current recommended
voltage and
current
Shutdown Standby sleep timing ON Configurable 48H Shutdown in
long standby
state

8. Function description

8.1 ON/OFF

Function Instruction
ON/OFF Press the ON/OFF key for more than 1 s, the LED lights turn on
from the capacity indicator light in turn, and then release, and
the BMS enters the power-on state
Press the ON/OFF key for more than 3s, the LED lights turn on
OFF/Dormant from the running light in turn, and then release, and the BMS
enters the shutdown state

8.2 Voltage detection and protection

Function Instruction
Voltage detection The detection accuracy of cell voltage is ± 10mV at 0~45 ℃
and ± 30mV at - 20~70 ℃.
Individual Over When any section of the cell reaches the Individual over voltage
voltage protection protection value, BMS closes the charging tube and stops
charging; When the voltage reaches the recovery value or the

21
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

discharge current reaches more than 3A, the over voltage


protection is removed.
Total pressure over When the voltage reaches the total voltage over voltage
voltage protection protection value, BMS closes the charging tube and stops
charging; When the voltage reaches the recovery value or the
discharge current reaches more than 3A, the over voltage
protection is removed.
Individual Under When any section of the cell reaches the single under voltage
voltage protection protection value, BMS will turn off the discharge tube for less
than 60s and enter the shutdown state; After the under voltage
protection, the charging is activated or the button is pressed to
start.
Total voltage under When the voltage reaches the single total voltage under voltage
voltage protection protection value, BMS turns off the discharge tube for 60s and
enters the shutdown state; After the under voltage protection,
the charging is activated or the button is pressed to start.

8.3 Current detection and protection

Function instruction
Current detection With charge and discharge current detection, the charge
current is displayed as positive current, and the discharge
current is displayed as negative current; The current sampling
accuracy can reach ± 2% at normal temperature.
Charging over current When there is no charging current limiting function, the current
protection reaches the charging over current protection value and reaches
the delay time; BMS closes the charging tube and stops
charging; When the BMS reaches the recovery delay, re-detect
the external charger current or discharge (current above 3A) to
remove the charging over current protection.
Charging secondary When there is no charging current limiting function, the current
over current reaches the charging secondary over current protection value
protection and reaches the delay time; BMS closes the charging tube and
stops charging; When the BMS reaches the recovery delay,
re-detect the current of the external charger or discharge
(current above 3A) to remove the charging secondary over
current protection.
Discharge over The current reaches the discharge over current protection value
current protection and reaches the delay time; BMS closes the discharge tube and
stops discharging; When the BMS reaches the recovery delay,
re-detect the external load current or charge (current above 3A)
to remove the discharge over current protection.

22
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

Discharge secondary The current reaches the discharge secondary over current
over current protection value and reaches the delay time; BMS closes the
protection discharge tube and stops discharging; When the BMS reaches
the recovery delay, re-detect the external load current or charge
(current above 3A) to remove the discharge secondary over
current protection.

8.4 Temperature detection and protection

Function Instruction
Temperature Have the temperature detection function of 4 cells, 1
detection environment and 1 MOS tube, and the temperature sampling
accuracy can reach ± 2 at normal temperature; The core
temperature sensor adopts 10K/3435/NTC thermistor.
Charging Regardless of charging and discharging, when the temperature
over-temperature reaches the charging over-temperature protection value, close
protection the charging tube and stop charging; If the temperature is less
than the over-temperature recovery value, the BMS will resume
charging.
Charging under Regardless of charging and discharging, when the temperature
temperature reaches the charging under temperature protection value, close
protection the charging tube and stop charging; The BMS will resume
charging when the temperature is greater than the temperature
recovery value
Discharge Regardless of charging and discharging, when the temperature
over-temperature reaches the discharge over-temperature protection value, close
protection the discharge tube and stop discharging; When the temperature
is less than the over-temperature recovery value, BMS will
resume discharging. (The charging temperature is also
protected after the general discharge temperature protection,
and the charging temperature setting value is lower than the
discharge temperature setting value)
Discharge under Regardless of charging and discharging, when the temperature
temperature reaches the discharge under temperature protection value,
protection close the discharge tube and stop discharging; The BMS will
resume discharging when the temperature is greater than the
temperature recovery value. (The charging temperature is also
protected after the general discharge temperature protection,
and the charging temperature setting value is higher than the
discharge temperature setting value)
Ambient over/under The NTC chip on the PCB board specially detects the internal
temperature temperature of the case, reaches the

23
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

protection over-temperature/under-temperature protection value, and


stops charging and discharging; Only when the ambient
temperature reaches the recovery value can it be charged and
discharged.
Power The NTC special power MOS tube temperature on the PCB
over-temperature board reaches the over-temperature protection value and stops
protection charging and discharging; Only when the power temperature
reaches the recovery value can it be charged and discharged.

8.5 Balancing function

Function Instruction
Standby balance BMS adopts energy consumption equalization circuit; When the
equalizing opening voltage reaches the set value and the
opening differential pressure, the equalizing is started; The
default starting voltage is 3.4V, the equalizing current is ≥
50mA, and the equalizing resistance temperature is not more
than 50 ℃.
Charge balance BMS adopts energy consumption equalization circuit; Under the
charging state, when the equalizing opening voltage reaches the
set value and the opening differential pressure, the equalizing is
started; The default starting voltage is 3.4V, the equalizing
current is ≥ 50mA, and the equalizing resistance temperature
is not more than 50 ℃.
High temperature The BMS stops equalizing when the temperature reaches the
prohibited balance equalizing high temperature setting.
Balance timeout The BMS stops balancing from the start of balancing to the
setting time.

8.6 Temperature rise

Function Instruction
Main heating The maximum temperature rise of BMS shall not exceed 70 ℃
components when the battery pack is discharged horizontally at the rated
discharge current under the temperature of 25 ℃; In the
environment with a temperature of 55 ℃, the battery pack is
tested flat and discharged at 0.1C. BMS MOSFET is not
protected.

24
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

8.7 Consumption

BMS working statue BMS consumption


Standby time-limit flow module is not started ≤40mA

Start of standby time-limit flow module ≤60mA


Shut down/hibernate ≤0uA
Power consumption of individual LCD screen ≤5mA

8.8 Storage

Function Instruction

Historical data storage State conversion, single battery voltage, total battery voltage,
charging/discharging current, temperature, etc; Record in
year/month/day/hour/minute/second, with storage capacity not
less than 500 records; The principle of first in first out is
adopted, and the stored content can be read through the
monitoring interface.

8.9 Pre-charge

Function Instruction
pre-charge in turning When BMS is turned off, press the key to start up, and the
on pre-charge function will be activated instantly to avoid short
circuit protection caused by capacitive load.
Pre-charge in standby BMS is suddenly connected to the capacitive load in standby
mode mode. BMS detects that it is the capacitive load to pre-charge
to avoid triggering the short-circuit protection.

25
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

8.10 Automatic dialing

Function Instruction
Automatic address The automatic address assignment of the parallel machine must
assignment be connected to the internal communication line according to
the parallel machine communication wiring method, otherwise
the address cannot be automatically assigned. Please check the
parallel machine communication method above.

8.11 One-button switch

Function Instruction
One-button off The host sends a command to the slave to shut down. The
shutdown method is to shut down the host manually. The host
will issue a command to the slave. The host will shut down after
the slave is shut down step by step (manual shutdown of the
slave is unable to achieve the one-button shutdown function).
One-button on After any one is powered on, other groups of BMS will be
activated gradually.

8.12 Inverter matching protocol definition

Inverter protocol Corresponding upper computer switching


protocol function
Pylon(CAN protocol) Pylon_CAN
Growatt(CAN protocol) Growatt_CAN
Goodwe(CAN protocol) Goodwe_CAN
Sofar(CAN protocol) Sofar_CAN
SMA(CAN protocol) SMA_CAN
Victron(CAN protocol) Victron_CAN
Studer(CAN protocol) Studer_CAN
Ginlong(CAN protocol) Ginlong_CAN
Voltronic(RS485 protocol) Voltronic_485
SRNE(RS485 protocol) SRNE_485
Growatt(RS485 protocol) Growatt_485
Pylon(RS485 protocol) Pylon_485
Deye(PylonRS485 protocol) Deye_485

26
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

8.13 Release control (optional)

Function Instruction

Control release The release is placed on the P-terminal, and the BMS can not
disconnection output close the charge and discharge in case of failure protection. The
after BMS failure BMS will give the release voltage to disconnect the release, so
that the BMS can not be charged and discharged externally

8.14 External switch (optional)

Function Instruction
BMS leads out a self-locking The BMS itself comes with a reset switch, which is
switch inconvenient for customers to turn on/off inside the
chassis; BMS specially opened an external switch with
12V power supply, which is convenient for customers to
switch on and off

27
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

8.15 Dry contact (optional)

Function Instruction
2-way dry contact BMS is equipped with 2-way dry contact function, and the
principle design uses the wet-joint passive scheme; One
channel is in alarm state and one channel is in protection state

8.16 LCD screen (optional)

Function Instruction
LCD screen BMS is equipped with LCD screen function. Now it is required to
turn on the LCD display function through the parameter
function switch of the upper computer, and connect the display
screen to the BMS LCD screen interface for use; The LCD screen
can switch the inverter protocol. Press the Enter key twice after
the corresponding protocol, and the protocol will switch
normally

28
SEPLOS SMART BMS3.0 SPECIFICATION WWW.SEPLOS.COM

9. Precautions for use


 The battery management system cannot be used in series.
 The withstand voltage of BMS power components is 100V.
 If the cell module is assembled in the form of long conductor and long copper bar, it must
communicate with BMS manufacturer to make impedance compensation. Otherwise, the
consistency of the cell will be affected.
 During assembly, the protective plate shall not directly contact the surface of the core to
avoid damage to the core. The assembly shall be firm and reliable.
 Pay attention not to touch the components on the circuit board with the lead head,
soldering iron and soldering tin during use, otherwise the circuit board may be damaged.
 Pay attention to anti-static, moisture-proof, waterproof, etc. during use.
 Please follow the design parameters and service conditions during use, and the value in this
specification shall not be exceeded, otherwise the protection plate may be damaged.
 After the battery pack and the protection board are assembled, if there is no voltage output
or no charging when the battery is powered on for the first time, please check whether the
wiring is correct. If there are still exceptions, please contact us.
 The management system has no 0V battery charging function. Once the battery is 0V, the
battery performance will be seriously degraded, and may even be damaged. In order not to
damage the battery, users need to recharge regularly when they are not in use for a long
time (more than 3 months). When in use, the battery should be charged within 12 hours
after being discharged to prevent the battery from discharging to 0V due to
self-consumption.
 The management system is not equipped with anti-charge protection function, and the
charging input cannot be reversed during use, otherwise the management system and
battery may be damaged.
 The Company reserves the right of final interpretation.