Aruze G-enex 2-Feb-15

RAM Clear Just After a RAM Corruption


1. When the machine is OFF, turn ON the RESET keyswitch.
2. Open the main door.
3. Open the security cage door.
4. Slightly withdraw the security cage door(about 2cm).
5. Turn ON the machine.
6. A RAM Clear message, “Turn the key to the neutral position, and choose 'CLEAR' or 'CANCEL'.”
7. Turn the key to the neutral position, the following message is displayed; Are you sure to clear the RAM?
YES : Turn the key to the AUDIT position and return to the neutral position.
NO : Turn the key to the RESET position.
8. Turn the key to the AUDIT position and return to the neutral position.
The message changes to "RAM cleared." to indicate the completion
9. When a hopper- or coin-related error appears, call the SETTING menu to set “HOPPER TYPE” to “NONE”.

Memory All Clear (used for setting up the paytable, denom)


1. Power down the machine and open CPU door
2. Replace GMEM cassette with Memory All Clear cassette containing 20100830 CF card
3. Turn on and wait for EEPROM & BKRAM ERASED to show on the screen than power down
4. Place back the GMEM game cassette, turn the RESET key ON and power up the machine
5. Wait for complete game loading, perform Touch Screen calibration then power down
6. Replace GMEM cassette with Setup Cassette containing Z11099-XXXX-ZA-205 CF and 0A75 Gal Chip
7. Power up and enter password: 26197356 when prompted

Important Setting Game Setting


Currency Canadian Dollar Payout variation #
Coin Denomination Denom
Tokenize 1 Online System
SAS Accounting Denom ONE CENT Send Exception (7E/7F) YES
Jurisdiction
Serial Number Hardware Setting
Bill Rejection Limit 10 Control Panel USA

8. All other Options leave as default at this point. Save and power down.
9. Place back the GMEM game cassette and leave cpu door open. Turn reset key ON and Power up, wait for game to load calibrate TS.
10. Turn the reset key to Audit and start setting up the options

Setting Online System Hardware Setting


System type IGT SAS 6.02 Hopper type NONE
SAS System Machine address N/A Tower Light type 2-Tier (Canada)
Cashless Transfer from Host Yes Coin Drop Door Switch Disabled
Legacy Bonus / MJT from Host NO Control Panel type USA
AFT Bonus from Host Yes LCD Topper default
Cashout Validation System LCD Topper volume default
Ticket data transfer mode MODE2 Data First
Send Exception (7E/7F) NO Bill Acceptor Setting
Bill Acceptor Enabled
Audit Setting $5 - $100 Enabled
Credit up limit site cr. limit
Credit in limit site cr. limit Game Setting
Ticket pay limit site cr. limit Payout variation #
Hopper max pay 0 Bet Type Set bet multipier
Hand pay configuration All Amount Pay
Residual Credit Removal None
Reset Jackpot to Credit 0 Software Setting
Jackpot Handpay limit site JP limit Demo Mode DEMO: OFF
Celebration Win limit 0 Topper Illumination Pattern Default
Asset number (UNREG) Asset # LED Brightness Middle
Cashless Out Cel. Win / Cr. Limit No Language Select Button USA / CHN
Cash out Cel. Win (Non-Cashless Mode) No

Ticket print Setting Attract Mode OFF


Printer Type Enabled
Print Cashable Ticket Yes
Print Restricted Ticket No Some Options
Print Foreign Restricted Ticket No May Change
Handpay Validation No When Connecting
Print Handpay Receipt No To EZ Pay
Print AFT receipt No
Ticket Redemption Yes
Cash to Printer