1 2 3 4 5 6 7 8 9 10 11 12

NOTE : STANDARD FASTENER TORQUE AS PER PST-DES-01 PFR-DES-07-REV-04

HOLE TABLE

H Hole X Y Size REMARK H


R 2

=
TYP A.1 0.00 0.00 Ø 31.00 mm THRU' REC SEC

50 TY
+0 0
X-X

.2 =
P
B.1 0.00 -32.00 Ø 6.60 mm THRU' REF SEC
0 C'BORE Ø 11.00 mm - 8.00 mm DEEP X-X
O 56 -0.1
B.2 32.00 0.00 Ø 6.60 mm THRU' REF SEC
.5 C'BORE Ø 11.00 mm - 8.00 mm DEEP X-X
B.3 33 YP
T
B.3 0.00 32.00 Ø 6.60 mm THRU' REF SEC
C'BORE Ø 11.00 mm - 8.00 mm DEEP X-X
C.1
G Y1
B.4 -32.00 0.00 Ø 6.60 mm THRU' REF SEC G
Y C'BORE Ø 11.00 mm - 8.00 mm DEEP X-X
A.1
C.1 22.63 22.63 Ø 6.00 mm THRU' H7 REF

45°
B.4 B.2 SEC Y-Y

45°
X X

2
0 .0 1
F B.1 F

7+0
H
6
1

23
.5°
E X1 E
0
O 125 -0.2

+0.05
O 90.1 +0.02 SECTION Y-Y
ZERO REF SCALE 1:1
a 0.02 B DEBURR AND REMOVE SHARP
EDGES UNLESS SHARP EDGE
REQUIREMENT SPECIFIED
UNSP.RADII UNSP.CHF.
0.5 R 0.5 X 45°
+0.2
20 +0.1

UNSPECIFIED TOL.(FAB)
FOR ANGULAR IN mm.
D UP TO 10 ±1.5° D
1 x45v
i 0.02 A 3 x45v
TYP

TYP 10 UP TO 50 ±0°50'
3

TYP 50 UP TO 120 ±0°25'


120 UP TO 400 ±0°15'
UNSPECIFIED TOL.(FAB)
O 11
12 ±0.02

FOR LINEAR IN mm.


0.5 UP TO 3 ±0.1
3 UP TO 6 ±0.2
35 -0.2

8
0

6 UP TO 30 ±0.5
30 UP TO 120 ±0.8
120 UP TO 315 ±1.2
315 UP TO 1000 ±2
5

1000 UP TO 2000 ±3
C O 6.6 OVER 2000 ±4
C
i 0.02 A +0.2 TOLERANCE NOTE :-
A O 31 +0.1 1) ALL H7 HOLES C.D SHOULD BE CONTROLLED WITHINu0.02. / IT7
UNSPECIFIED TOL.(M/C)
FOR ANGULAR IN mm.
r 0.02
R 0.2 2) ALL HOLES,TAP & COUNTER BORE C.D, UP TO 10 ±1°
MAX +0.035 SHOULD BE CONTROLLED WITHIN u0.2. 10 UP TO 50 ±0°30'
O 90 H7 0 n 0.02 A 50 UP TO 120 ±0°20'
SECTION X-X 120 UP TO 400 ±0°10'
1 x 45° SCALE 1:1 B UNSPECIFIED TOL.(M/C)
FOR LINEAR IN mm.
TYP. H.T.PROCESS : CASE HARDENED MTC REPORT REQURIED 0.5 UP TO 3 ±0.1
HARDNESS & DEPTH : 56~60 HRC. NON DESTRUCTIVE TESTING 3 UP TO 6 ±0.1
FINISH & DEPTH : QPQ & DEPTH 0.8~1.2 mm
TEST COUPON SIZE :O125-20mm LENGTH RAW MATERIAL HEAT TREATMENT FINISH COMPOMENT 6 UP TO 30 ±0.2
UT DP+UT MPI 30 UP TO 120 ±0.3
B 120 UP TO 315 ±0.5 B
315 UP TO 1000 ±0.8
1000 UP TO 2000 ±1.2
OVER 2000 ±2
11/09/2023 5829
\\srv01043\ExDM Uploading\2022-23\PRV73\PRV73A101076.dft

1 MISSING DIMENSION ADDED & MACHINING SYMBOL REMOVED


LIMITS
REVISION DESCRIPTION DATE DRN.BY Gen Tol.: IS 2102
WIPRO PARI PRIVATE LIMITED
[Formerly Known as Precision Automation and Robotics India Limited]
DESCRIPTION DRAWING TYPE
www.wipropari.com
1.ALL DIMENSIONS ARE BEARING LOCATOR MACHINING
IN mm SURFACE AREA FINISH MACHINING MATERIAL NET WEIGHT-Kg TEAM NO. SHEET SIZE
2.DO NOT SCALE
DRAWING. 59.50 in^2 IZBP ( ) 20MnCr5 1.11 kg PL-02 A2
A RESERVED SPACE 3.IF IN DOUBT ,
SURFACE FINISH HEAT TREATMENT REF NOTE
A
ASK TEAM MEMBER
FOR
LOCATION : PUNE DRN.BY CHKD.BY APPD.BY REFERENCE DWG. DRG./PART CODE REV. SCALE
CONTROLLED COPY
STAMP VIVEK
---- 1:1
C ALL RIGHTS OF REPRODUCTION & PRATIBHA SHIVA G
NOTE FOR WIPRO PARI DESIGN -REF. ONLY
WEAR DETAILS : W
DISTRIBUTION ARE RESERVED PART CLASS. PRV73A101076 01 SHEET
11/09/2023 11/09/2023 11/09/2023 T+S 1 OF 1

1 2 3 4 5 6 7 8 9 10 11 12