GINLONG TECHNOLOGIES CO.,LTD.
S5-GC(50-60)K
Solis Three Phase Grid-Tied Inverters
Efficient Safe
• Max. efficiency 98.7% • IP66, C5 Anti-Corrosion Level
• String current up to 16A • Intelligent redundant fan-cooling
• 5/6 MPPT design, supports multiple • Globally recognised branded componentry for
orientation system design longer life
• Night time PID recovery function, increases • AFCI protection, proactively reduces fire risk
overall system yield (optional)
Smart Economic
• Night SVG function • Supports GPRS/WiFi communication with less
• Supports export power control wiring and reduced installation costs
• Intelligent string monitoring, smart I-V • DC side supports "Y" connector
curve scan • 10/12 string inputs allow for 150%+ DC oversizing
• Scan to register on SolisCloud, supports
remote upgrade and control
Models:
S5-GC50K / S5-GC60K
360º View
www.solisinverters.com
DATASHEET S5-GC(50-60)K
Models 50K 60K
Input DC
Max. input voltage 1100 V
Rated voltage 600 V
Start-up voltage 195 V
MPPT voltage range 180-1000 V
Max. input current 5*32 A 6*32 A
Max. short circuit current 5*40 A 6*40 A
MPPT number/Max. input strings number 5/10 6/12
Output AC
Rated output power 50 kW 60 kW
Max. apparent output power 55 kVA 66 kVA
Max. output power 55 kW 66 kW
Rated grid voltage 3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 76.0 A / 72.2 A 91.2 A / 86.6 A
Max. output current 83.6 A 100.3 A
Power factor >0.99 (0.8 leading - 0.8 lagging)
THDi <3%
Efficiency
Max. efficiency 98.7%
EU efficiency 98.3%
Protection
DC reverse-polarity protection Yes
Short circuit protection Yes
Output over current protection Yes
Surge protection DC Type II / AC Type II
Grid monitoring Yes
Anti-islanding protection Yes
Temperature protection Yes
Strings monitoring Yes
I/V Curve scanning Yes
Integrated AFCI (DC arc-fault circuit protection) Yes (1)
Integrated PID recovery Optional (2)
Integrated DC switch Optional
General Data
Dimensions (W*H*D) 691*578*338 mm
Weight 53.7 kg
Topology Transformerless
Self-consumption (night) <1 W
Operating ambient temperature range -25 ~ +60°C
Relative humidity 0-100%
Ingress protection IP66
Cooling concept Intelligent redundant fan-cooling
Max. operation altitude 4000 m
G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /
Grid connection standard
UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530
Safety/EMC standard IEC 62109-1/-2, IEC62116 & IEC 61000-6-1/-2/-3/-4
Features
DC connection MC4 connector
AC connection OT terminal (max. 70 mm²)
Display LCD, Capacitive touch buttons
Communication RS485, USB, Optional: Wi-Fi, GPRS
(1) Activation required. (2) Due to the similar functional logic, when the night time PID-Recovery function is integrated, the night time var compensation function
can not be used. Also, the negative grounding option is not available for inverters with night time PID-Recovery function.