Please read the manual in details Please use the right plug and right voltage

before operation Be much attention of 110V or 220V!!!

Don’t clean the indicator with the Avoiding the insects in for protecting PCB
Flush water and other electronic components

Don’t touch the keypad with the Don’t open the indicator by yourself and
Items with sharp end please call the service people or our distributor
when you get the problem with it

2
I. Technical Parameter

1.A/D Conversion: ∑-⊿

2.Input Signal Range: 0-10mv


3.A/D Resolution: 1,000,000
4.A/D Conversion Speed: 10times/second
5.Excitation Voltage: DC5V
Excitation Current: (4) 350 Ohm load cells or (8) 700 Ohm load cells
6.Display: 18 digits LCD 0.8”
7.Divisions:
1/2/5/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005/10/20/50/100/200/500
8.Serial Output Interface: RS—232 continuous transmitting,
Baud Rate 1200 2400 4800 9600 optional
RS—485 optional
9.Printing: RS232 printing output
10.A.C Power: AC110/220V (AC/DC built-in battery 6V 4Ah)
11.Operating Temperature: 0℃~40℃
12.Storage Temperature: -25℃~55℃
13.Relative Humidity: ≦85 RH
14.Exterior Size: 220mm×140mm×130mm
15.Weight: Around 2 Kg
II. Connection
1.The load cell adopts D 9-pins socket as follows:

(Note: If using 4-wire shielded cable, short connected +E with +R, and –E with –R.)

2.Communication Connection (D-SUB-9-pins):


3rd pin TXD (RS-232C continuous transmitting)
5th pin GND
3.Communication Data Format (RS-232C continuous transmitting)
The communication address X = 0 in continuous transmitting and the format is
=,X1,X2,X3,X4,X5,X6. The transmitting X1,X2,X3,X4,X5,X6 is displaying data, and “ = ”is the list
separator.
Example: weight: 100.00kg, transmitting: = 00.001 =00.001.
4. RS-485 optional

3
III. Keypad & Signs

ON, Keep pressing for OFF Clear, Keep pressing for ZERO

SET, Memory unit set Memory retrieve, Keep pressing Kg/Lb

M+(accumulation), printing Tare, Keep pressing for preTare set

…… : digits
Display: The 1st line---weight value
The 2nd line----unit price or unit weight
The 3rd line----total amount or quantity
Sign lights:
P----price computing C----counting function

Zero Point ---Tare Net weight ---Stable

kg--- unit is kg lb---unit is lb ABC---Input letters

---No power ---Power shortage AC---AC power supply

IV. Parameter Setting


1. Connecting the load cell well before parameter setting
2. Set parameters as following steps:
(Attention: calibration plug must be pushed on the position ON)

4
3. Press to confirm and enter next step

Step Operation Display Note


1 UEr10.0
Press EnSEt Switch on and then press
CLoCK EnSEt Means parameter setting and calibration allowed
(CLoCK is plus model with clock)

2 000000 Self-Checking

999999

3 ------ Needs password


Press SEt
------ Input 2003 and press to enter parameter setting

1 Division chose
-d-

1
4 2 0.001-0.002-0.005-10-20-50-100-200-500-0.10-0.20-0.50-1-
Press 5 2
0.1 -5-0.1-0.2-0.5-0.01-0.02-0.05
Press C to choose, example of 0.1
5 6000 Full Scale setting
Press -FS-
Press 3
Press 0 6000 Example 3000
Press 0 3
Press 0 30
300
3000
6 0 0—2 filtering chose, the value smaller, speed faster,
Press -FLt- value bigger, the more stable, so choose smaller value
0 if the weighing condition good, if not, choose the big
1 value
Press 1 Example: FLt =1

5
7 10 Ones place digit (the 0 of 10) represents the option of
Press automatically power off function or not.
AutP Ones place 0:No automatic power off function
Ones place 1:Automatic power off
10 Tens place digits (the 1 of 10) represents zero tracking
Press 1 range (1~9):
Press 1 1:0.4 d 2:0.8 d 3:1.2 d 4:1.6 d
1 5:2 d 6:2.4 d 7:2.8 d 8:3.2d 9:3.6 d
11 Also Tens place represents the zero range upon power
on:
Tens digit 0 not zero when power on
Tens digit>0 zero rang is 20 F·S when power on
Eg AutP 11
8 01 Communication address chose serial continuous
Press -Adr- output format
01 Adr = 00 (weight sending from end, 100.0 = 0.001)
Adr=99 (weight sending from beginning, 100.0 =100.0)
Adr=98 (Amount/Quantity)
Adr=01-97 (serial printing ouput)
9 2400 Baud Rate chose 2400 4800 9600
Press bAud Eg: b=4800
2400
4800

Press
10 0 Mode chose when power on
Press P-c 0--Price computing
0 1--Counting
Eg: 0

11 2 Decimal point (in total amount window) chose 0-4


Press P-Pt 0---none
2 1-4----0.0 0.00 0.000 0.0000
Eg: 2

12 0 End of parameter setting


Press
V. Calibration
After parameter setting, you can start to do calibration according to following steps:
Step Operation Display Note
1 ------ Needs password, input 8888 and press
Press SEt
------ Enter calibration mode

6
2 n LOAd Zero Calibration
Press CAL 0 xxxxxx A/D internal code
xxxxxx
4 Make sure no ------ Displays the full scale value after
object on CAL 0 several seconds of finish of zero
platform and ------ calibration
then press

3 Put the full LOAd Prepare for full scale calibration


scale weight CAL (If 60% calibration or other mode,
on the 003000 please change the weight value
platform according to the weights you are
using)

4 ------ Displays full scale value (or the weight


Press CAL value as you input) after several
------ seconds
5 3000 End of calibration
0.00
0.00
VI. Normal Operation
(Attention: Calibration plug must be at position of OFF)

1. On/OFF: Switch on and press to power on the indicator and Press for 2
seconds more to power off the indicator

(Another function of ON/OFF: pressing can abort any present operation to back to
weighing mode)

2.Zero: Weight 2 F.S press for 2 seconds or more, display ZERO and →0← light on
3.Tare:
a. Tare: on the state of →T← light off weight Is above 0 and stable light on,

press to tare and the →T← light on

b. Tare clearance: When the →T← light on, press key to clear the tare value and the
light →T← off

c. PreTare: Pressing for 2 seconds or more it displays”------” to input the tare value and

then press

4.Letter Input It can store 4 sentences and 30 letters for each sentence
On the weighing mode, keep pressing 0 -- 3 key for 2 seconds more to input four
sentences by ASCII code, numbers input just with digits keys, example of A7B input with
7
following steps (ASCII code table refer to appendix at last page)
Step Operation Display Note
1 Pressing 1 for Input start
2 seconds
more --

2 Press 6 5 The ASCII code of A is 65

65
3 A A entered
Press
--
4 Press 7 A

7
5 A7 A7 Input
Press
--
6 Input B A7b
according to Press to backwards and input
above steps -- again
again
7 A7b
Press If letters Is more than 12, press to

display all the letters and press


again to back to the input mode, If
the letters is more than 30, the first
letter will be deleted automatically
8 Keep pressing A7b The words/sentence are stored in
1 again for position of 1 and back to weighing
2 seconds -- mode
more

5.Words/Sentence use:
Keep pressing 0 -- 3 key to display words/sentence in position of 0-3 and press 0 --
3 key again to quit display and then the words/sentence which pressed just now can be
used.
Example: to use the words/sentence on [2], keep pressing [2] to display the
words/sentence stored in [2] and press [2] again to choose it and start to use it.
6.Words/sentence printing set:

Keep pressing 9 to display PtF mode and input 0-2 and press
PtF
0--The present chosen words/sentence printing at head
8
1-- The present chosen words/sentence printing at end
2-- The present chosen words/sentence printing at head, the following sentence printing at
end (such as words/sentence chosen of [2] now, the words/sentence of [2] will be
printed at head and the sentence/words of position [3] will be printed at end.

7. Accumulation operation: When the weight is above 20d and stable, press key to
accumulate the displayed value, and the first display window display the
accumulated weight, and the second display window display the
accumulated times and the third window display the total amount
accumulated. It will back to normal weighing mode after one second.
It displays the accumulated weight, accumulated times and accumulated
quantities in the counting mode
(Note: one weighing operation can do accumulation once time only, next
accumulation must be operated when the weight display less than 20d and
weigh something again.)

8.Printing: When weight value above 20d and stable, keep press for twice times, it
will accumulate the value and also if the Adr= set with 01-97 (printing allowed),
it will print the following receipt:
Price computing mode PtF=0 Counting mode PtF=2
A7B (example only) A7B (example only)
No 0016 No 0012
G: 10.00Kg G: 52.01Kg
T: 3.00Kg T: 2.01Kg
N: 7.00Kg N: 50.00Kg
P: 1.23$ U: 21.322Kg
S: 8.61$ C: 2345p

9. Accumulation retrieve, printing and clearance:

Press the 1st line display the accumulated times, 2nd and 3rd line display the

accumulated amount or quantities press to display the accumulated weight

and press again to back to weighing mode. During it displays the

accumulated data, press can print the accumulated data as following format,

and at this time, press can clear the accumulated data. During it displays the

accumulated amount/quantities; press can back to weighing mode


Example:
The accumulated amount Accumulated quantity Accumulated Weight
n 123 n 102 n 102
S 2 C 1 23
2301.20 021389 0012.85
9
Printing example:
Price computing Counting
No 0018 NO 0018
W 1926.72Kg W: 6215.72Kg
S: 2369.87$ C: 891213p

10.Price computing/Counting exchange:

Press and then keep pressing for 2 seconds or more can exchange the
mode of price computing or counting, the P light means price computing and C
light means counting
11. Price computing operation:
a. Unit price input: Input the digits: example of 1.23, input 1 2 3 , if no input operation
for 5 seconds, next input will be taken as the new unit price input. Press

to clear the unit price

b. Unit price store: Press +2 digits (01-28, totally 28 memories) can store the present

unit price, such as the present unit price of 1.23, now press and (0)
(3), it store in 03 unit price memory;

c. Unit Price retrieve: Press and memory numbers, such as pressing and 0 3
to use the 03 Memory unit price
12. Counting operation
a. unit weight input: Put the samples on the platform (the more, the better) and then input

the quantity of samples, and then press to confirm, such as

123pcs, input 1 2 3

b. Unit weight store: Press +2 digits (01-28) can store the present unit weight,

c. Unit weight retrieve: Press and memory numbers, such as pressing and 0 3
to use the 03 Memory unit price

13.Battery volume: on weighing mode, press to display battery volume and press

to back
14.Charging notice: when battery volume < 12 % the light on, please recharge in
time
15. Low battery protection:

When the battery is too low and light on, the beeper will sound di—di---di,

please recharge in time to protect the battery.


10
When the battery is over, the 1st window displays Lo and 2nd window displays
bAtt the indicator will power off automatically
16. Power saving:
When the automatic power off function work, it will display - only to save power
if 5 minutesno operation
17.Automatic power off:
When the automatic power off function work, it will power off automatically if 30
minutes no operation
18.Working time: it last for 20 hours more with full charge
V. Maintenance and Notices:
1.Do not use the indicator under strong sunlight for protecting the using life of it. Keep it on flat while
using.
2.Do not use it in the places full with dust and strong vibration.
3.Do not overload (including the tare weight) (more than full scale is prohibited.).
4.Do not cleanout the case with strong impregnant (such as, benzene, nitric acid oile, etc.)
5.Keep the interior part of indicator away from the water for avoiding the damage to the electrical
components and electronic shock to people.
6.Switch off the power when some problem happened while in operation. The user (non-manufacturer
of scales) please send the indicator to our company for repair, and it is not allowed to repair at will
for avoiding more damage to the indicator.
7.The indicator will charge the battery automatically while the AC power being connected.
VI. Repair Guarantee & Service
The repair guarantee time is 1 year from the selling date of this indicator, and the problem
should be happened due to the problem of the indicator itself while in right operation (not due
to wrong operation). We supply the service to the indicator for life. (Battery exclude the repair
guarantee)
Note: The repair guarantee not responsible for all problem of the weighing system while our
indicator only act as a part of this system, we only take charge of the problem caused
from the indicator itself.

VII. Abnormal Display


OUE -------weight value> 100 % F·S + 9 d
-OUE -------weight value negative overflow
Err--1 ------weight not stable while calibration
Err--2 -------calibration wrong
Lo
bAtt ----battery over, power off automatically

11
APPENDIX (ASCII CODE)
LETTER A B C D E F G H I
display

ASCII 65 66 67 68 69 70 71 72 73
LETTER J K L M N O P Q R
display

ASCII 74 75 76 77 78 79 80 81 82
LETTER S T U V W X Y Z
display

ASCII 83 84 85 86 87 88 89 90
LETTER - .
display

ASCII 40 41 44 45 46
Number digits can be input by number keys and also can be input by ASCII code
0-9 with ASCII code of 48-57