SOLAR SENSOR

SOLUTIONS
SEVENSENSORSOLUTIONS

TABLE OF CONTENTS

SEVEN Weather Stations 3

Irradiance Sensor 7

Dual Orientations Sensor 8

Multi-Orientations Sensor 9

Albedometer 10

Thermopile Pyranometer 11

Module Temperature Sensor 12

Ambient Temperature Sensor 13

Wind Speed Sensor 14

Wind Direction Sensor 15

Relative Humidity & Ambient Temperature Sensor 16

Soiling Sensor 17

Portable Soiling Sensor 18

Low Cost Irradiance Sensor 19

Rain Sensor 20

Compact Weather Station 21

Snow Sensor 22

Mounting Systems 23

Irradiance Sensor Box 24

Sensor Box Selection 26

Modbus RTU Technical Specifications 27

SunSpec Technical Specifications 32

Modbus Selection Table 33

1
SEVENSENSORSOLUTIONS

ABOUT US
SEVEN Sensor Solutions is a trade mark of ArGesim Makina, located in the Industrial Area of Corum in
Türkiye. It is specialized in producing, installing and commissioning high-quality meteorological sensors
used for monitoring solar PV plants. SEVEN weather stations are compatible with many well known
datalogger brands.

In 2018, the company moved to Corum Technopark and focused more on R&D activities. These activities
were fruitful and resulted in international patents for ArGesim.

SEVEN Sensor products are used in more than 85 countries all over the world, from Japan to USA. High
quality, Fast delivery and on time after sales service are the basics of our good reputation in the market.

ArGesim carries out R&D activities with young engineers and continue to work in line with this mission
by serving the industrialization goals of our country in the field of high technology.

2
SEVENSENSORSOLUTIONS

WEATHER STATIONS
Ambient Temperature Ambient Temperature
Sensor Sensor

Smartlogger Ezlogger

Wind Speed Wind Speed


Sensor Sensor
Irradiance Sensor Irradiance Sensor
(PV Pyranometer) (PV Pyranometer)

RS485 RS485
Modbus RTU Modbus RTU

Wind Direction Sensor


Wind Direction Sensor

Module Temperature
Module Temperature Sensor
Sensor

Huawei Goodwe
Weather Station. Weather Station.

Ambient Temperature
Sensor
Data Manager M
Ambient Temperature
Sensor
ShineMaster

Wind Speed Irradiance Sensor Wind Speed


Irradiance Sensor Sensor (PV Pyranometer) Sensor
(PV Pyranometer) RS485
Modbus RTU
RS485
Modbus RTU

Wind Direction Sensor Relative Humidity


Sensor
Module Temperature
Sensor

Relative Humidity
Sensor

Module Temperature
Sensor

SMA Growatt
Weather Station. Weather Station.

3
SEVENSENSORSOLUTIONS

WEATHER STATIONS
Ambient Temperature
Ambient Temperature Sensor
Sensor Datalogger
Logger

Irradiance Sensor Wind Speed


Irradiance Sensor Wind Speed (PV Pyranometer) Sensor
(PV Pyranometer) Sensor RS485
RS485
Modbus RTU
Modbus RTU

Relative Humidity
Relative Humidity Wind Direction Sensor
Wind Direction Sensor Sensor
Sensor
Module Temperature
Module Temperature Sensor
Sensor

Sungrow Bluelog
Weather Station. Weather Station.

Gateway

Ambient Temperature
VSN700 or Sensor Irradiance Sensor
PVS-100/120-TL Inverter Module Temperature
(PV Pyranometer)
4-20mA or 0-10V

Sensor
0-1,5V

Ambient Temperature
Sensor
Irradiance Sensor Wind Speed
(PV Pyranometer) Sensor Wind Speed Sensor
RS485
Modbus RTU

4-20mA

4-20mA or 0-10V
Wind Direction Sensor Module Temperature
Sensor

Wind Direction Sensor

4-20mA

ABB/FIMER SolarEdge
Weather Station. Weather Station.

4
SEVENSENSORSOLUTIONS

WEATHER STATIONS
Ambient Temperature
Sensor

Ezlogger

Ambient Temperature
Sensor
E-Manager Pro

Wind Speed
Sensor
Irradiance Sensor
(PV Pyranometer)

RS485
Irradiance Sensor Wind Speed Modbus RTU
(PV Pyranometer) Sensor
RS485
Modbus RTU

Relative Humidity Wind Direction Sensor


Wind Direction Sensor Sensor
Module Temperature Module Temperature
Sensor Sensor

Kehua Tech General Electric


Weather Station. Weather Station.

Ambient Temperature
Ambient Temperature S3-Logger Sensor
ePowerLog DL Sensor

Irradiance Sensor Wind Speed Irradiance Sensor Wind Speed


(PV Pyranometer) Sensor (PV Pyranometer) Sensor
RS485
Modbus RTU
RS485
Modbus RTU

Wind Direction Sensor Relative Humidity


Sensor Relative Humidity
Module Temperature
Sensor Wind Direction Sensor Sensor

Module Temperature
Sensor

Elum Solis
Weather Station. Weather Station.

5
SEVENSENSORSOLUTIONS

WEATHER STATIONS
Ambient Temperature
Sensor Ambient Temperature
Edge Controller Ai Logger 1000 Sensor

Wind Speed
Sensor
Irradiance Sensor Irradiance Sensor
(PV Pyranometer) Wind Speed (PV Pyranometer)
Sensor
RS485 RS485
Modbus RTU Modbus RTU

Relative Humidity Wind Direction Sensor


Wind Direction Sensor Sensor Module Temperature
Sensor
Module Temperature
Sensor

Wattch Solplanet
Weather Station. Weather Station.

Ambient Temperature Ambient Temperature


SolaX DataHub 1000 Sensor Sensor
RapitLog

Irradiance Sensor Wind Speed Irradiance Sensor Wind Speed


(PV Pyranometer) Sensor (PV Pyranometer) Sensor
RS485 RS485
Modbus RTU Modbus RTU

Relative Humidity
Wind Direction Sensor Sensor Wind Direction Sensor Relative Humidity
Sensor
Module Temperature Module Temperature
Sensor Sensor

SolaX Power Sico


Weather Station. Weather Station.

6
SEVENSENSORSOLUTIONS

HopeComBox1000-G03 / Ambient Temperature Ambient Temperature


Sensor Sensor
HopePowerBox ASC-4 Solar / ASC 150 Solar

Wind Speed Wind Speed


Irradiance Sensor Sensor Irradiance Sensor Sensor
RS485 RS485
Modbus RTU Modbus RTU

Relative Humidity Relative Humidity


Wind Direction Sensor Sensor Wind Direction Sensor Sensor
Module Temperature Module Temperature
Sensor Sensor

Hopewind DEIF
Weather Station. Weather Station.

Ambient Temperature
Sensor Ambient Temperature
Gateway Sensor
SOLARIFY D-517RA

Wind Speed
Irradiance Sensor Sensor Wind Speed
Irradiance Sensor Sensor
RS485
Modbus RTU RS485
Modbus RTU

Relative Humidity
Wind Direction Sensor Sensor Relative Humidity
Module Temperature Wind Direction Sensor Sensor
Sensor Module Temperature
Sensor

VTC Solarify
Weather Station. Weather Station.

7
SEVENSENSORSOLUTIONS

IRRADIANCE
SENSOR
(PV Pyranometer)

TECHNICAL DATA
3S-IS 3S-IS-T-I 3S-IS-T-V
Sensor Type Silicon Reference Cell (31 mm x 31 mm)
Irradiance, Cell & Module
& Ambient Temperature,
Meassured Data Wind Speed & Direction and Irradiance and Cell Temp. Irradiance and Cell Temp.
Relative Humidity
Irradiance Range 0 - 1600 W/m²
Uncertainty ≤2% (Less than 2%; as per IEC 61724-1 standard Class A)

Resolution 0.1 W/m² (Less than 1W/m²; as per IEC 61724-1 standard Class A)
Response Time 1 sec. (Less than 3 sec; as per IEC 61724-1 standard Class A)

Drift <0.3% / year


Field of View 170° (Larger than 160° as per IEC 61724-1 standard Class A)

Tilt-Azimuthal Angle 0°- 0° (≤1°; as per IEC 61724-1 standard Class A)


Output Rate 1/s - -
Data Output RS485 up to 38400 Baud Analog 4-20 mA Analog 0-1,5 V
Communication Protocol Modbus RTU - -
Power Supply 12 to 30 V DC
Power Consumption 30 mA max @24 VDC 50 mA max @24 VDC 15 mA max @24 VDC
Electrical Connection 3 m LIYYC11Y PUR Cable, UV and Weather Resistant
1000 V between power
Galvanic Isolation - -
supply and RS485 bus
Cell Temperature Sensor Type PT1000 Class A as per EN 60751
Operating Temperature Range -40°C to +85°C
Operating Humidity Range 0 to 100 % RH

Box Dimensions 140 mm x 110 mm x 42 mm


(W x L x H)

Weight 0.3 kg
IP Rating IP 54 (Optional IP 65, IP 68)
Sensor Housing Material Aluminum
Compliant Standard IEC 61724-1:2021 and IEC 60904
Each sensor is calibrated under Class AAA Sun Simulator as per IEC 60904-2 and
Calibration
IEC 60904-4 by using a reference cell calibrated by ISFH-Germany
Each sensor is tested in natural sunlight using a reference cell calibrated by the
Test
Fraunhofer ISE Institute in Germany.

8
SEVENSENSORSOLUTIONS

DUAL ORIENTATIONS
IRRADIANCE SENSOR (3S-2IS)

Special Solution for dual orientation plants:

3S-2IS model is specially developed to calculate the Performance Ratio (PR) for the dual orientation
PV plants, as it calculates the average irradiance value as per the number of panels in each direction.
Installation directions of panels in PV power plants and the number of panels in these directions may
be different. The user will be able to set the number of panels in each orientation for the correct
calculations. 3S-2IS special design allows simultaneous connection of two Irradiance Sensors, two
Module Temperature Sensors, Ambient Temperature Sensor and Wind Speed Sensor.

The number of panels in both directions, to which the sensors are connected to, is entered into the
electronic card via 3S-2IS Configuration Interface. The total effective irradiance and total effective
module temperature can be calculated and communicated to the datalogger via Modbus RTU
protocol. By using these values, the accurate Performance Ratio can be calculated in the monitoring
systems.

9
SEVENSENSORSOLUTIONS

MULTI-ORIENTATION
IRRADIANCE SENSOR
(3S-4IS) / (3S-3IS)

TECHNICAL DATA
3S-4IS / 3S-3IS
Total Effective Irradiance, Total Effective Module Temperature, 4 nos. POA Irradiance, 4 nos. Cell
Measured Data
Temperature, 4 nos. Module Temperature, Ambient Temperature, Wind Speed and Wind Direction
Output Rate 1/s
Data Output RS485 up to 38400 Baud

Communication Protocol Modbus RTU


Power Supply 12 to 30 V DC
Power Consumption 40 mA max @ 24 V DC
Electrical Connection 3 m LIYYC11Y PUR Cable, UV and Weather Resistant
Galvanic Isolation 1000 V between power supply and RS485 bus
Operating Temperature Range -40°C to +85°C
Operating Humidity Range 0 to 100 %RH
Dimensions (Connection Box / Sensor) 1123 mm x 1000 mm x 633 mm / 140 mm x 110 mm x 42 mm (W x L x H)
Weight (Mounting Structure / Sensor) 5.8 kg / 0.5 kg

IP Rating (Connection Box / Sensor) IP 67 / IP 54 (Optional IP 65, IP 68)

Material (Connection Box / Sensor) ABS / Aluminum


Standard IEC 61724-1:2021 and IEC 60904
Each sensor is calibrated under a Class AAA Sun Simulator according to IEC 60904-2 and IEC 60904-4
Calibration
standards using a reference cell calibrated by the ISFH Institute in Germany.Germany.
Each sensor is tested in natural sunlight using a reference cell calibrated by the Fraunhofer ISE Institute
Test
in Germany.

10
SEVENSENSORSOLUTIONS

ALBEDOMETER

TECHNICAL DATA
3S- ALBEDOMETER
Sensor Type Silicon Reference Cell (31 x 31 mm)
Measured Data POA Irradiance, Reflected Irradiance and Solar Albedo
Irradiance Range 0 - 1600 W/m²
Uncertainty 1.2 % (less than 2%; as per IEC 61724-1 standard Class A)

Resolution 0.1 W/m² (less than 1 W/m²; as per IEC 61724-1 standard Class A)
Response Time 1 sec (less than 3 sec; as per IEC 61724-1 standard Class A)
Field of View 170° (Larger than 160° as per IEC 61724-1 standard Class A)
Tilt-Azimuthal Angle 0°- 0° (≤1°; as per IEC 61724-1 standard Class A)

Output Rate 1/sec


Data Output RS485 up to 38400 Baud
Communication Protocol Modbus RTU
Power Supply 12 to 30 V DC
Power Consumption 20 mA max @24 VDC
Electrical Connection 3 m LIYYC11Y PUR Cable, UV and Weather Resistant

Galvanic Isolation 1000 V between power supply and RS485 bus


Operating Temperature Range -40°C to + 85°C
Operating Humidity Range 0 to 100 %
Box Dimensions 210 mm x 155 mm x 85 mm (L x W x H)

Weight 0.67 kg
IP Rating IP54 (Optional IP 65, IP 68)

Sensor Housing Material Aluminum


Standard IEC 61724-1:2021 and IEC 60904
Each sensor is calibrated under Class AAA Sun Simulator as per IEC 60904-2 and IEC 60904-4 by using a
Calibration
reference cell calibrated by ISFH-Germany

11
SEVENSENSORSOLUTIONS

THERMOPILE
PYRANOMETER

TECHNICAL DATA
3S-TP-MB 3S-TP-MB-B 3S-TP-MB-C
Sensor Type Thermopile
Classification as per ISO 9060:2018 Spectrally Flat Class A Spectrally Flat Class B Spectrally Flat Class C
Measuring Range - 200 ... 4000 W/m2
Spectral range (50%) 283 - 2800 nm 300 - 2800 nm
Response time (95%) <2s < 10 s < 18 s
Zero offsets:
a) Thermal radiation (at 200 W/m²) < |±7| W/m2 < |±10| W/m2 < |±15| W/m2
b) Temperature change (5 K/h) < |±2| W/m2 < |±4| W/m2 < |±4| W/m2

Non-stability (change/year) < |±0,5| % < |±1| %


Non-linearity < |±0,2| % < |±1| %
Response according to the cosine law < |±10| W/m2 < |±18| W/m2 < |±20| W/m2

Spectral error < |±0,2| % < |±0,5| % < |±1| %


Temperature response (-10…+40 °C) < |+0,5| % < |±1,5| % < |±2| %
Tilt response < |±0,2| % < |±1| % < |±1,5| %
Accuracy of levelling device < 0.2°

Output Digital RS485-Modbus RTU (Analog options available)


Power Supply 7 to 30 VDC
Electrical Connection 3 m LIYYC11Y PUR Cable, UV and weather resistant
Operating Temperature Range -40°C to +80°C
Dimensions Ø 160 x 101 mm Ø 59 x 60 mm
IP Rating IP 67
Shade Disk Included On Request
Analog output options available.

12
SEVENSENSORSOLUTIONS

MODULE
TEMPERATURE
SENSOR

TECHNICAL DATA
3S-MT-PT1000 3S-MT-PT1000-MB 3S-MT-PT1000-I 3S-MT-PT1000-U
Sensor Type PT1000
Measuring Range -40°C ... +85°C
Accuracy ±0.1°C
Resolution 0.1°C
Data Output PT1000 RS485 up to 38400 Baud Analog 4-20 mA Analog 0-10 V
Communication Protocol - Modbus RTU -
Power Supply - 12...30 V DC
Power Consumption - 15 mA @ 24 V DC 30 mA @ 24 V DC 15 mA @24 V DC
1.5 m LIYYC11Y PUR Cable, 0.5 m 4x0.15 LIYYC11Y PUR Cable and 2.5 m 3x2x0.22 mm² 3 m LIYYC11Y PUR Cable, UV
Electrical Connection
UV and Weather Resistant LI2Y(SE)GRP PUR Cable, UV and Weather Resistant and Weather Resistant
Operating Temperature Range -40°C ... +85°C
Box Dimensions - 82 x 80 x 55 mm (W x L x H) 115 x 65 x 55 (WxLxH)
Sensor Cover Dimensions Ø 35 x 3 mm
Weight 77 gr 417 gr 297 gr
IP Rating IP 67
Box Material - *ABS
Sensor Cover Laminated Backsheet (EVA - Tedlar)
Mounting Method 3M®Sticker to Back of Panel
Standard Class A according to IEC 60751:2022

13
SEVENSENSORSOLUTIONS

AMBIENT
TEMPERATURE
SENSOR

TECHNICAL DATA
3S-AT-PT1000 3S-AT-PT1000-MB 3S-AT-PT1000-I 3S-AT-PT1000-U
Sensor Type PT1000
Measuring Range -40°C to +85°C
Accuracy ±0.1°C
Resolution 0.1°C
Data Output PT1000 RS485 up to 38400 Baud Analog 4-20 mA Analog 0-10 V
Communication Protocol - Modbus RTU -
Power Supply - 12 ... 30 V DC
Power Consumption - 15 mA @ 24 V DC 30 mA @ 24 V DC 15 mA @ 24 V DC
1.5 m LIYYC11Y PUR Cable, 0.5 m 4x0.15 LIYYC11Y PUR Cable and 2.5 m 3x2x0.22 3 m LIYYC11Y PUR Cable, UV
Electrical Connection UV and Weather Resistant mm² LI2Y(SE)GRP PUR Cable, UV and Weather Resistant and Weather Resistant
Operating Temperature Range -40°C to +85°C
Box Dimensions - 82 x 80 x 55 mm (W x L x H) 115 x 65 x 55 (WxLxH)
Shield Dimensions Ø 105 x 100 mm
Weight 127 gr 467 gr 347 gr
IP Rating IP 67
Box Material - ABS
Sensor Housing Material Stainless Steel Tube
Shield Material ABS
Mounting Method Ground Mounting
Standard Class A according to IEC 60751:2022

14
SEVENSENSORSOLUTIONS

WIND
SPEED
SENSOR

TECHNICAL DATA
3S-WS-PLS 3S-WS-MB 3S-WS-I 3S-WS-I-H
Sensor Type Cup Star Anemometer (Reed Switch)

Measuring Range 0,9 to 40 m/s 0,9 to 50 m/s

Accuracy Below 5m/s 0.5 m/s and 10% of reading above 5m/s

Resolution 0,1 m/s


Threshold 0,9 m/s

Survival Speed 60 m/s 80 m/s

Data Output Read Relay RS485 up to 38400 Baud Analog 4-20 mA

Communication Protocol - Modbus RTU -

Power Supply - 12 to 30 V DC

Heating - - - Available
3 m LIYY Cable, UV
Electrical Connection 3m LIYYC11Y PUR Cable, UV and Weather Resistant
and Weather Resistant
Operating Temperature Range -40°C to +85°C (Ice Free) -40°C to +85°C

Dimensions Ø 180 x 145 mm Ø 170 x 266 mm


Weight 0,2 kg 0,6 kg

IP Rating IP 54 (Optional IP 65)


Housing Material Anodized Aluminum
Cup Material ABS
Mounting Method Pipe or Ground Mounting
Standard Compliant to IEC 61724-1:2021

15
SEVENSENSORSOLUTIONS

WIND
DIRECTION
SENSOR

TECHNICAL DATA
3S-WD 3S-WD-MB 3S-WD-I
Sensor Type Vane-Driven Hall Effect Position Sensor
Measuring Range 0-359°
Accuracy ±1% of Measuring Value
Resolution 1°
Start Speed 1 m/s

Data Output Analog (0 V – 3.3 V) Modbus RTU - RS485 Analog 4-20 mA


Communication Protocol - Modbus RTU -
Power Supply - 12 to 30 V DC
Power Consumption - 20 mA typically at 24 VDC 30 mA typically at 24 VDC
3 m LIYY Cable, UV and
Electrical Connection 3m LIYYC11Y PUR Cable, UV and Weather Resistant
Weather Resistant
Operating Temperature Range -40°C to +85°C (Ice Free)
Dimensions Ø: 290x195 mm
Box Dimensions - L x W x H : 55x80x82 mm

Weight 0,25 kg
Box Weight - 0,25 kg
IP Rating IP 54 (IP67 Optional)

Housing Material Aluminum


Vane Material Aluminum

Box Material - ABS (Color may change when exposed to sunlight.)

Mounting Method Pipe or Ground Mounting


Standard Compliant to IEC 61724-1:2021

16
SEVENSENSORSOLUTIONS

RELATIVE
HUMIDITY &
AMBIENT
TEMPERATURE
SENSOR

TECHNICAL DATA
3S-RH&AT 3S-RH&AT&PS 3S-RH&AT-MB 3S-RH&AT&PS-MB 3S-RH-I
Relative Humidity and Relative Humidity, Ambient Relative Humidity and Relative Humidity, Ambient
Measured Data Ambient Temperature Temperature and Pressure Ambient Temperature Temperature and Pressure
Relative Humidity

Sensor Type Capacitive


RH Range 0% to 100%
RH Accuracy ±1% RH (20 ... 70%) at 25 °C
RH Resolution 0.1%
T Range -40°C to +85°C -
T Accuracy ±0.1% °C at (5 ... 60 °C) -
T Resolution 0.1°C -

Pressure Range - 260 to 1260 hPa - 260 to 1260 hPa -

Pressure Accuracy - 0.5 hPa - 0.5 hPa -

Pressure Resolution - 0.1 hPa - 0.1 hPa -

Data Output I²C RS485 up to 38400 Baud Analog 4-20 mA


Communication Protocol - Modbus RTU -
Power Supply 3 V DC 12 to 30 V DC
Power Consumption - 20 mA max @ 24 VDC 30 mA @ 24 V DC

3 m LIYYC11Y PUR Cable, 0,3 m 4x0,15 mm


Electrical Connection
UV and Weather Resistant 2,5 m 3x2x0,22 mm
Operating Temperature Range -40°C to +85°C
Box Dimensions - 82 x 80 x 55 mm (W x L x H)
Shield Dimensions Ø 105 x 100 mm

Weight 0,2 kg 0,55 kg

IP Rating IP 65
Box Material - ABS*
Sensor Housing Material Stainless Steel Tube - Membran Filter
Shield Material ABS*
Class A according to IEC 60751:2022 (Temperature)
Standard
Class A according to IEC 61724-1:2021 (Relative Humidity)

*Since this product contains plastic parts, color changes may occur when exposed to direct sunlight.

17
SEVENSENSORSOLUTIONS

SOILING SENSOR

TECHNICAL DATA
3S-SMS-MB 3S-SMS-MB-M
Soiling Ratio 0% - 100%
Resolution 0,1%
Uncertainty ≤1%
Followed Standard IEC61724-1 (Annex C)
Interface RS485 up to 38400 Baud
Communication Protocol Modbus RTU
Protection IP65 IP65 (IP68 Optional)

Power Supply 100-240 V AC or 24 V DC 5 A 12 to 30 V DC

Irradiance 0…1600 w/m²


Each sensor is calibrated under Class AAA Sun Similator as per IEC
Calibration
60904-2 by using a reference cell calibrated by ISFH-Germany.
Each sensor is tested under natural sunlight by using a calibrated reference cell
Test
from Fraunhofer ISE, Germany.
Operating Temperature -20°C / +85°C -40°C / +85°C
Water Tank Capacity 18 Liter -

Water Consumption 36lt./year (2 times filling per year) -

Cleaning Fluid Pure Water -


%65 Pure Water + %35 Antifreeze
Antifreeze Ratio -
(Weather conditions ≤ 0°)
*Max. Water Line Length 25 Meter -

*Max. Water Line Height 5 Meter -

SEVEN offers the Manually Cleaned Soiling Sensor when the cost of the system matters. It has the same features like automatic one.
The difference is cleaning of the sensor which is manually.

18
SEVENSENSORSOLUTIONS

PORTABLE
SOILING
SENSOR

TECHNICAL DATA

Soiling Rate 0% - 100%


Resolution 0.1%

Sensor Uncertainty ≤ 2%

Software Update RS485 3S-SMS-P


Operating Temperature -10°C to +50°C
Operating Humidity Range 0 ... 90 % RH

Power Supply 12 V 24 Ah Lithium Battery


Operating Time 3 hours
Charging Time 3 hours

Dimensions 318 mm x 386 mm x182 mm (W x L x H)

Weight 8.6 kg

19
SEVENSENSORSOLUTIONS

LOW-COST
IRRADIANCE
SENSOR

TECHNICAL DATA
3S-IS-LR
Measured Data Plane of Array Irradiance
Sensor Type Silicon Reference Cell (31 x 31 mm)
Measuring Range 0 ... 1600 W/m2
Uncertainty ≤3%
Resolution 0.1 W/m²
Response Time 1s
Drift <0.3% / year
Field of View 170°
Tilt-Azimuthal Angle 0°- 0°
Output Rate 1/s
Data Output RS485 up to 38400 Baud
Communication Protocol Modbus RTU
Power Supply 12 to 30 V DC

Power Consumption 10 mA max @ 24 V DC


Electrical Connection 3 m LIYYC11Y PUR Cable, UV and Weather Resistant
Galvanic Isolation 1000 V Between Power Supply and RS485 Bus
Operating Temperature Range -40°C to +85°C
Operating Humidity Range 0 to 100 % RH
Box Dimensions 118 mm x 84 mm x 55 mm (W x L x H)
Weight 0.2 kg

IP Rating IP 67

Sensor Housing Material ABS*


Each sensor is tested in natural sunlight using a reference cell calibrated by the Fraunhofer ISE
Test
Institute in Germany.

20
SEVENSENSORSOLUTIONS

RAIN
GAUGE

TECHNICAL DATA
3S-RG-MB 3S-RG-PLS
Sensor Type Tipping Bucket Rain Gauge
Measuring Range 600 mm/h
±%1 (0 mm/h - 30mm/h)
Accuracy ±%2 (30mm/h - 100mm/h)
±%5 (100mm/h-600mm/h)
Resolution 0.2 mm
Collecting Area 200 cm²
Data Output RS485 up to 38400 Baud Reed Relay
Communication Protocol Modbus RTU -
Power Supply 12 to 30 V DC -

Power Consumption 35 mA @ 24 V DC -
3 m LIYYC11Y Cable, 3 m LIYY Cable,
Electrical Connection
UV and Weather Resistant UV and Weather Resistant
Operating Temperature Range 0°C to +85°C
Dimensions Ø 160 x 257 mm
Connection Box Dimensions 70.2 x 82 x 55 (W x L x H)

Weight 1.4 kg 1,2 kg

IP Rating IP 65

Housing Material Plexiglass

Connection Box Material ABS*

21
SEVENSENSORSOLUTIONS

COMPACT
WEATHER
STATION

TECHNICAL DATA
3S-CWS
Global & Plane of Array Irradiance, Module & Ambient Temperature, Wind Speed &
Measured Data
Direction, Relative Humidity, Air Pressure and Precipitation.
Standards Compliant to IEC 61724-1:2021
Digital Outputs RS485 up to 38400 Baud

Communication Protocol Modbus RTU


(Optional Modbus TCP/IP)

Output Rate 1/s


Operating Temperature Range -40°C to +85°C
Operating Humidity Range 0 to 100 %RH
Mounting Structure Aluminum & Stainless Steel

Dimensions 720 x 1370 x 855 mm (W x L x H)


(Height can be changed as per request)

Weight 4.8 kg

IP Rating IP 54
(Optional IP 67)

Power Supply 12 to 30 V DC

Power Consumption 25 mA @ 24 V DC
Electrical Connection 3 m LIYYC11Y PUR Cable, UV and weather resistant
Connection Box Material ABS*
Galvanic Isolation 1000 V between power supply and RS485 Bus

22
SEVENSENSORSOLUTIONS

SNOW
SENSOR

TECHNICAL DATA
3S-SS-MB
Snow Ratio %5 - %100
Resolution %0.1
Uncertainty ≤2%
Irradiance Range 0…1600 W/m²
Data Output RS485 up to 38400 Baud
Communication Protocol Modbus RTU
Output Rate 1/s
Operating Temperature Range -40°C to +85°C
Operating Humidity Range 0 to 100 %RH
Power Supply 22 to 30 V DC
Power Consumption 0.82 A max @ 24VDC (While heating off 0.02 A max @24 VDC)
Electrical Consumption 3m LIYYC11Y PUR Cable, UV and weather resistant
Galvanic Isolation 1000 V Between Power Supply and RS485 Bus
IP Rating IP 65
Dimensions 200 x 412 x 44 mm
Weight 1845 g
Each sensor is calibrated and normalized under Class AAA Sun Similator as per IEC 60904-2 by
Calibration
Using a reference cell calibrated by ISFH-Germany
Each sensor is tested under natural sunlight by using a calibrated reference cell from Fraunhofer ISE,
Test
Germany.

23
SEVENSENSORSOLUTIONS

Mounting
Systems

SEVEN produces custom designed mounting systems for easy sensor installation in site, especially for
Rooftop projects. It is a tower combining different sensors as per the installation requirements.

SEVEN Mounting System is a custom product designed as per the site conditions and the sensors to be
mounted. It is made of Chrome as it is strong and has a high resistance against the Weather conditions.

TECHNICAL DATA
3S-MS
Material Coated Steel
Length 1123 mm
Width 635 mm
Height 1048 mm (it can be changed as per request)

24
SEVENSENSORSOLUTIONS

IRRADIANCE
SENSOR
BOX
Model: 3S-IS-mV Model: 3S-IS-T-I Model: 3S-IS-T-V

Datalogger Datalogger Datalogger

4-20 mA

0-1,5V
mV

Irradiance Sensor with mV 4-20 mA analog output for Irradiance 0-1,5 V analog output for Irradiance Value
output Value

Model: 3S-IS Model: 3S-IS-1


Model: 3S-IS-2
Datalogger
Datalogger Datalogger
RS485
RS485
RS485

Modbus RTU output for Irradiance Value Irradiance Sensor with an external temperature Irradiance Sensor with an external
Cell Temperature Sensor Included sensor (Module Temperature Sensor or Ambient Temperature Sensor (Module Temperature
Temperature Sensor) Sensor or Ambient Temperature Sensor), and
Wind Speed Sensor

25
SEVENSENSORSOLUTIONS

Model: 3S-IS-2T Model: 3S-IS-3


Datalogger Datalogger

RS485
RS485

Irradiance Sensor with external two temperature sensors; Sensors can be connected to Irradiance Sensor; Module
Module Temperature Sensor, and Ambient Temperature Sensor Temperature Sensor, Ambient Temperature Sensor, and Wind
Speed Sensor

Model: 3S-IS-4 Model: 3S-IS-5


Datalogger Datalogger
RS485

RS485

Following sensors can be connected to Irradiance Sensor; Following sensors can be connected to Irradiance Sensor;
Module Temperature Sensor, Ambient Temperature Sensor, Module Temperature Sensor, Ambient Temperature Sensor,
Wind Speed Sensor, and Wind Direction Sensor or Relative Wind Speed Sensor, Wind Direction Sensor, and Relative
Humidity Sensor Humidity Sensor

Model: 3S-2IS Model: 3S-4IS


Datalogger
RS485

Two Irradiance Sensors, Two Module Temperature Sensors, 4 Irradiance Sensors, 4 Module Temperature Sensors, Ambient
Ambient Temperature Sensor, and Wind Speed Sensor can be Temperature Sensor, Wind Direction Sensor, and Wind Speed
connected. Special Solution when it’s a dual orientation plant. Sensor can be connected.

26
SEVENSENSORSOLUTIONS

3S-C2
SELECTION OF SENSOR BOX
Wind Speed Sensor
Ambient Temperature Datalogger
Sensor
or
Module Temperature
Sensor

Ambient Temperature
Sensor Seven Sensor Box
or
Module Temperature
Sensor

Relative Humidity
Sensor
Ambient Temperature Wind Direction
Sensor
or Sensor

Module Temperature
Sensor

Model: 3S-C2-2 Model: 3S-C2-3 Model: 3S-C2-4

Sensor Box with two sensor connections Sensor Box with three sensor connections Sensor Box with four sensor connections

Model: 3S-C2-5 Model: 3S-C2-6

Sensor Box with five sensor connections Sensor Box with six sensor connections

27
SEVENSENSORSOLUTIONS

Technical Specifications
Modbus RTU
Common Modbus Register Map

A common input register map has been created for all SEVEN Modbus devices.

SEVEN Modbus devices can be configured to operate in different communication parameters. The table
that follows describes each supported bus protocol.

Baud Rate 4800, 9600, 19200, 38400


Parity None, Even, Odd
Stop Bit 1, 2 (only at None parity)
Factory Default 9600 Baud, 8N1, address: 1

The following Modbus data can be read individually or in blocks:


Read carefully the notes at the bottom of the table about the parameters.
You can find which parameter is included in which sensors in the matching matrix after the table.

COMMON MODBUS REGISTER MAP


ID-Dec ID-Hex Parameter Range Resolution Description
Irradiance value in W/m² of the reference cell
Irradiance (1)
without temperature compensation.
Irradiance value in W/m² of one of the referen-
ce cells without temperature compensation in
solutions developed for PV plants with two or
more orientations.
30000 0x00 Irradiance 1 (2) 0-1600 W/m² 0.1 W/m²
Irradiance value of the clean reference cell for
the Soil Monitoring System in W/m² without
temperature compensation.
The downwelling irradiance value from the sky
in W/m² without temperature compensation in
solution developed for bifacial PV plants.
Irradiance value in W/m² of one of the referen-
ce cells without temperature compensation in
solutions developed for PV plants with two or
more orientations.
Irradiance value of the soiled reference cell
30001 0x01 Irradiance 2 0 - 1600 W/m² 0.1 W/m²
for the Soil Monitoring System in W/m² without
temperature compensation.
The upwelling ground-reflected irradiance va-
lue in W/m² without temperature compensation
in solution developed for bifacial PV plants.
Irradiance value in W/m² of one of the refe-
rence cells without temperature compensation
30002 0x02 Irradiance 3 0 - 1600 W/m² 0.1 W/m²
in solution developed for PV plants with multi
orientations.
Irradiance value in W/m² of one of the refe-
rence cells without temperature compensation
30003 0x03 Irradiance 4 0 - 1600 W/m² 0.1 W/m²
in solution developed for PV plants with multi
orientations.

28
SEVENSENSORSOLUTIONS

COMMON MODBUS REGISTER MAP


ID-Dec ID-Hex Parameter Range Resolution Description
Temperature Irradiance value in W/m² of the reference cell.
Compensated Is a temperature compensated and calibrated
Irradiance (3) value.
Irradiance value in W/m² of one of the referen-
ce cells in solutions developed for PV plants
with two or more orientations. Is a temperature
compensated and calibrated value.
30006 0x06 0 - 1600 W/m² 0.1 W/m²
Temperature Irradiance value of the clean reference cell for
Compensated the Soil Monitoring System in W/m². Is a tem-
Irradiance 1 (2) perature compensated and calibrated value.
The downwelling irradiance value from the
sky in W/m² in solution developed for bifacial
PV plants. Is a temperature compensated and
calibrated value.
Irradiance value in W/m² of one of the referen-
ce cells in solutions developed for PV plants
with two or more orientations. Is a temperature
compensated and calibrated value.
Temperature Irradiance value of the soiled reference cell for
30007 0x07 Compensated 0-1600 W/m² 0.1 W/m² the Soil Monitoring System in W/m². Is a tem-
Irradiance 2 perature compensated and calibrated value.
The upwelling ground-reflected irradiance
value in W/m² in solution developed for bifacial
PV plants. Is a temperature compensated and
calibrated value.
Irradiance value in W/m² of one of the referen-
ce cells in solution developed for PV plants
with multi orientations. Is a temperature com-
Temperature pensated and calibrated value.
30008 0x08 Compensated 0 - 1600 W/m² 0.1 W/m²
Irradiance 3 Irradiance value in W/m² of one of the referen-
ce cells in solution developed for PV plants
with multi orientations. Is a temperature com-
pensated and calibrated value.
Irradiance value in W/m² of one of the reference
Temperature
cells in solution developed for PV plants with
30009 0x09 Compensated 0 - 1600 W/m² 0.1 W/m²
Irradiance 4
multi orientations. Is a temperature compensa-
ted and calibrated value.
Irradiance value in W/m² of the reference cell
Irradiance (4)
without temperature compensation.
Temperature Irradiance value in W/m² of the reference cell.
Compensated Is a temperature compensated and calibrated
Irradiance (3) value.
30012 0x0C 0 - 1600 W/m² 0.1 W/m² Irradiance value in W/m² calculated proporti-
Total Effective onally from the irradiance values of eac h of
Temperature the reference cells in solutions developed for
Compansated PV plants with two or more orientations. It is
Irradiance (5) a temperature compensated and calibrated
value.
Ratio of upwelling irradiance to downwelling
30014 0x0E Albedo 0-1 0.01 irradiance in solution developed for bifacial PV
plants.

29
SEVENSENSORSOLUTIONS

COMMON MODBUS REGISTER MAP


ID-Dec ID-Hex Parameter Range Resolution Description
Internal Temperature Internal cell temperature value of the referen-
(3)
ce cell.
Internal cell temperature value of one of the
reference cells in solutions developed for PV
plants with two or more orientations.
30015 0x0F (-40) - (+85)°C 0.1°C
Internal Temperature Internal cell temperature value of the clean
1 (2) reference cell for the Soil Monitoring System.
Internal cell temperature value of facing
upwelling reference cell in solution develo-
ped for bifacial PV plants.
Internal cell temperature value of one of the
reference cells in solutions developed for PV
plants with two or more orientations.
Internal Temperature Internal cell temperature value of the soiled
30016 0x10 (-40) - (+85) °C 0.1°C
2 reference cell for the Soil Monitoring System.
Internal cell temperature value of facing
downwelling reference cell in solution deve-
loped for bifacial PV plants.
Internal cell temperature value of one of the
Internal Temperature
30017 0x11 (-40) - (+85) °C 0.1°C reference cells in solution developed for PV
3
plants with multi orientations.
Internal cell temperature value of one of the
Internal Temperature
30018 0x12 (-40) - (+85) ° 0.1°C reference cells in solution developed for PV
4
plants with multi orientations.
Module temperature value calculated propor-
Total Effective Module tionally from the values of each of the module
30021 0x15 -40) - (+85) °C 0.1°C
Temperature (5) temperature sensors in solutions developed
for PV plants with two or more orientations.
Module Temperature The value of the module temperature sensor
(3)
attachment back of the modules in PV plants.
Module temperature value of one of the mo-
Module Temperature dule temperature sensors in different orien-
30022 0x16 1 (5) (-40) - (+85) °C 0.1°C tations in solutions developed for PV plants
with two or more orientations.
Temperature value of the external tempera-
External Temperature
ture sensor connected on channel 1 of the
1 (7)
Multi PT1000 Modbus Converter.
Module temperature value of one of the mo-
Module Temperature dule temperature sensors in different orien-
2 (5) tations in solutions developed for PV plants
30023 0x17 (-40) - (+85) °C 0.1°C with two or more orientations.
Temperature value of the external tempera-
External Temperature
ture sensor connected on channel 2 of the
2 (7)
Multi PT1000 Modbus Converter.

30
SEVENSENSORSOLUTIONS

COMMON MODBUS REGISTER MAP


ID-Dec ID-Hex Parameter Range Resolution Description
Module temperature value of one of the mo-
Module Temperature dule temperature sensors in different orienta-
3 (5) tions in solution developed for PV plants with
30024 0x18 (-40) - (+85)°C 0.1°C multi orientations.
Temperature value of the external tempera-
External Temperature
ture sensor connected on channel 3 of the
3 (7)
Multi PT1000 Modbus Converter.
Module temperature value of one of the mo-
Module Temperature dule temperature sensors in different orienta-
4 (5) tions in solution developed for PV plants with
30025 0x19 (-40) - (+85) °C 0.1°C multi orientations.
Temperature value of the external tempera-
External Temperature
ture sensor connected on channel 4 of the
4 (7)
Multi PT1000 Modbus Converter.
Temperature value of the external tempera-
External
30026 0x1A (-40) - (+85) °C 0.1°C ture sensor connected on channel 5 of the
Temperature 5
Multi PT1000 Modbus Converter.
Temperature value of the external tempera-
External
30027 0x1B (-40) - (+85) °C 0.1°C ture sensor connected on channel 6 of the
Temperature 6
Multi PT1000 Modbus Converter.
Temperature value of the external tempera-
External
30028 0x1C (-40) - (+85) °C 0.1°C ture sensor connected on channel 7 of the
Temperature 7
Multi PT1000 Modbus Converter.
Ambient Temperatu- Air temperature value of the ambient tempe-
re (8) rature sensor.
30029 0x1D (-40) - (+85) °C 0.1°C Temperature value of the external tempera-
External Temperature
ture sensor connected on channel 8 of the
8 (7)
Multi PT1000 Modbus Converter.
Ambient Temperature Air temperature value of the compact relative
30032 0x20 (-40) - (+85) °C 0.1°C
(SHT) humidity and ambient temperature sensor.
Relative Humidity Relative humidity value of the compact relati-
30033 0x21 0 - 100 % 0.1 %
(SHT) ve humidity and ambient temperature sensor.
Air pressure value of the absolute pressure
30035 0x23 Air Pressure 260 - 1260 hPa 0.1 hPa
sensor.
Rainfall Intensity Rain intensity value per hour of the tipping
30036 0x24 0 - 900 mm/hr mm/hr
(Hour) bucket rain gauge.
Rainfall Intensity Rain intensity value per minute of the tipping
30037 0x25 0 - 15 mm/min mm/min bucket rain gauge.
(Minute)

Rainfall Intensity 0 - 0.25 mm/ Rain intensity value per second of the tip-
30038 0x26 mm/sec ping bucket rain gauge.
(Second) sec

31
SEVENSENSORSOLUTIONS

COMMON MODBUS REGISTER MAP


ID-Dec ID-Hex Parameter Range Resolution Description
Instantaneous value of the ratio of the tem-
Instant Soiling perature compensated irradiance value of the
30042 0x2A 0-1 0.01
Ratio soiled reference cell to that of the clean refe-
rence cell, in the Soil Monitoring System.
Daily average value of the ratio of the tempe-
Daily Average rature compensated irradiance value of the
30043 0x2B 0-1 0.01
Soiling Ratio soiled reference cell to that of the clean refe-
rence cell, in the Soil Monitoring System.
Instantaneous value of fractional power loss
Instant Soiling
30044 0x2C 0-1 0.01 due to soiling, given by 1 – Instant Soiling
Level
Ratio.
Daily average value of fractional power loss
Daily Average
30045 0x2D 0-1 0.01 due to soiling, given by 1 – Daily Average
Soiling Level
Soiling Ratio.
Instantaneous Soiling Level value in %. Com-
Instant Soiling
30046 0x2E 0 - 100 % 0.1 % puted as the percent.
Level Percentage

Daily Average Daily average Soiling Level value in %. Com-


30047 0x2F Soiling Level 0 - 100 % 0.1 % puted as the percent.
Percentage

The rate of change of the daily average soiling


level percentage. It is calculated by comparing
30048 0x30 Soiling Rate (-100) - (+100) % 0.1 %
it with the previous day's value and is usually
expressed as a daily percentage.
Wash Tank Automatic cleaning unit wash tank status. (1:
30050 0x32 0-1 -
Status full or 0: empty)
Horizontal wind direction value of the wind

vane.
30052 0x34 Wind Direction 0 - 359°
Wind direction value of the ultrasonic anemo-
0.1°
meter.
Horizontal wind velocity value in m/s of the cup
0 - 40 m/s 0.1 m/s
Wind Speed star anemometer.
30053 0x35
(m/s) Wind velocity value in m/s of the ultrasonic
0 - 60 m/s 0.01 m/s
anemometer.
Wind Speed Wind velocity value in knots of the ultrasonic
30054 0x36 0 - 120 knots 0.01 knots
(knots) anemometer.
Wind Speed Wind velocity value in km/hr of the ultrasonic
30055 0x37 0 - 216 km/h 0.01 km/h
(knots) anemometer.

32
SEVENSENSORSOLUTIONS

SunSpec and Modbus


Serial/ General
Baud Rate: 9600
Parity: None RS-485 Modbus
Stop Bits: 1 Interface Mode: 2-Wire Half Duplex Device ID: 61

Register Map:

33
SEVENSENSORSOLUTIONS

MODEL SELECTION TABLE


Sensor Box Irradiance Cell Temperature Connec�ons:
Model Sensor Sensor The following external sensors can be connected to the sensor box Communica�on / Protocol

3S-IS-T-V   NA 0-1,5V
3S-IS-T-I   NA 4-20 mA
3S-IS-LR   NA RS485 - Modbus RTU
3S-IS   NA RS485 - Modbus RTU
3S-IS-1   Module Temperature Sensor (3S-MT-PT1000) or Ambient Temperature Sensor (3S-AT-PT1000) RS485 - Modbus RTU

Module Temperature Sensor (3S-MT-PT1000) or Ambient Temperature Sensor(3S-AT-PT1000) +


3S-IS-2   RS485 - Modbus RTU
Wind Speed Sensor (3S-WS-PLS)

Module Temperature Sensor (3S-MT-PT1000) +


3S-IS-2T   RS485 - Modbus RTU
Ambient Temperature Sensor (3S-AT-PT1000)

Module Temperature Sensor (3S-MT-PT1000) +


3S-IS-3   Ambient Temperature Sensor (3S-AT-PT1000) + RS485 - Modbus RTU
Wind Speed Sensor (3S-WS-PLS)

Module Temperature Sensor (3S-MT-PT1000) +


Ambient Temperature Sensor (3S-AT-PT1000) +
3S-IS-4   Wind Speed Sensor (3S-WS-PLS) + RS485 - Modbus RTU
Wind Direc�on Sensor (3S-WD) or Rela�ve Humidity
& Ambient Temperature Sensor (3S-RH & AT)

Module Temperature Sensors (3S-MT-PT1000) +


Ambient Temperature Sensor (3S-AT-PT1000) +
3S-IS-5   Wind Speed Sensor (3S-WS-PLS) + RS485 - Modbus RTU
Wind Direc�on Sensor (3S-WD) +
Rela�ve Humidity & Ambient Temperature Sensor (3S-RH & AT)

2 pcs. Module Temperature Sensor (3S-MT-PT1000) +


Ambient Temperature Sensor (3S-AT-PT1000) +
 Wind Speed Sensor (3S-WS-PLS) + RS485 - Modbus RTU
3S-2IS 

4 pcs. Module Temperature Sensor (3S-MT-PT1000) +


Ambient Temperature Sensor (3S-AT-PT1000) +
3S-4IS RS485 - Modbus RTU
  Wind Direc�on Sensor (3S-WD) +
Wind Speed Sensor (3S-WS-PLS)

Irradiance Sensor (3S-IS-mV) +


Module Temperature Sensor (3S-MT-PT1000) +
Rela�ve Humidity & Ambient Temperature Sensor (3S-RH & AT) +
3S-CWS   Wind Speed Sensor (3S-WS-PLS) + RS485 - Modbus RTU
Wind Direc�on Sensor(3S-WD) +
Rain Gauge (3S-RG-PLS) +
Air Pressure Sensor

3S-C2-2   2 Sensors can be connected RS485 - Modbus RTU


3S-C2-3   3 Sensors can be connected RS485 - Modbus RTU
3S-C2-4   4 Sensors can be connected RS485 - Modbus RTU
3S-C2-5   5 Sensors can be connected RS485 - Modbus RTU
3S-C2-6   6 Sensors can be connected RS485 - Modbus RTU

34
SEVENSENSORSOLUTIONS

SOLAR
SENSOR
SOLUTIONS

SCAN ME !

www.sevensensor.com
[email protected]
+90 (0364) 230 12 33
Argesim Makina Gıda San. Tic. Ltd. Sti
Address: Pinarcay OSB Mah. Organize San. 11. Cad. No: 35 , Merkez, Corum.Türkiye
35

You might also like