Service Support

D
Note :
[1] Restoration from troubles.
There are 2 ways as illustrated below to restore it from troubles.
In order to clear an error code depending on circumstances, control of main switch is necessary
as follows:.
1: Turn ON the key switch to start the engine, hold the switch for 10 second as it is turned ON,
and then turn it OFF to restore it to be normal.
2: Turn ON the key switch, hold the switch for 10 second as it is, and then turn it OFF to restore
it to be normal.
For temperature sensors marked with "*" in the table however, hold the key switch for 3
minutes after it has been turned ON, then turned it OFF.
Faulty EGR valve control 0488 Nothing in particular
When the difference between the target
valve lift and the actual position is larger
than 20% for 10 seconds or longer
EGR valve all-close command
Wiring defect (disconnection, short, high resistance) between
ECM and EGR motor
EGR valve defect
ECM internal defect
2
Faulty oil pressure sensor
(abnormally low voltage)
0522 Nothing in particular
The oil pressure sensor voltage is 0.1 V or
lower for 4 seconds or longer.
No backup
Wiring defect (short) between ECM and oil pressure sensor
Oil pressure sensor defect
ECM internal defect
2
Faulty oil pressure sensor
(abnormally high voltage)
0523 Nothing in particular
The oil pressure sensor voltage is 4.85 V or
higher for 4 seconds or longer.
No backup
Wiring defect (disconnection, short, high resistance) between
ECM and oil pressure sensor
Oil pressure sensor defect
ECM internal defect
2
Faulty ROM
(ECM internal component
part)
0601 Engine stop
Faulty ROM detected
Reflash failure
No backup (engine stop) ECM internal defect 2
Faulty EEPROM
(ECM internal component
part)
0603 Nothing in particular Faulty EEPROM detected No backup ECM internal defect 2
Faulty CPU
(ECM internal component
part)
0606 Drop of output power, starting not possible
The CPU monitoring IC detects faulty main
CPUs for 100 ms after the key is switched
ON.
The RUN-SUB pulse (signal between CPU
and SUB-CPU) was unchanging for 20 ms
or longer.
Multi-injection stop
Injection quantity restriction
The SUB-CPU stopped the CPU.
ECM internal defect 2
Faulty CPU monitoring IC 0606 Drop of output power
The RUN-SUB pulse (signal between CPU
and SUB-CPU) was unchanging for 20 ms
or longer.
Injection quantity restriction ECM internal defect 2
Faulty charge circuit 1 0611
Engine vibration, idling instability, drop of
output power
Possibility of rev-up defect, engine stalling
When the ECU charge circuit bank 1 voltage
is low for 1.5 seconds or longer
Common 1 stop (No. 1, 4 cylinder stop)
EGR stop
ECM terminal, ECM ground terminal defect (disconnection, high
resistance)
ECM internal defect
2
Faulty charge circuit 2 0612
Engine vibration, idling instability, drop of
output power
Possibility of rev-up defect, engine stalling
When the ECU charge circuit bank 2 voltage
is low for 1.5 seconds or longer
Common 2 stop (No. 2, 3 cylinder stop)
EGR stop
ECM terminal, ECM ground terminal defect (disconnection, high
resistance)
ECM internal defect
2
Pressure limiter open 1095 Drop of output power, hunting
When the pressure limiter is open or when
the common rail pressure exceeds 200 MPa
for 1 second or longer
Injection quantity restriction
Fuel system pipe (hose), etc. blocked
Air in fuel system (check hose connection.)
Pressure limiter defect
Common rail pressure sensor defect
Wiring defect (short) between ECM and common rail pressure
sensor
Supply pump defect
ECM internal defect
1