Window Schedule
Window Schedule
8'-0" The designer is not responsible for the accuracy of survey, structural,
mechanical, electrical, etc., information shown on this drawing. Refer
2'-8" 1'-0" 7'-0" 5" 2'-4" 5" 2'-4" 5'-8" 2'-4" 3'-0" to the appropriate consultant's drawings before proceeding with the
SECOND F. CEILING work. Construction must conform to all applicable codes and
requirements of authorities having jurisdiction. The contractor
108.51
2'-0"
2'-0"
2'-0"
2'-0"
F.G. 1'-8" 2'-0" WINDOW 2'-0" 2'-0" working from drawings not specifically marked 'for construction' must
PROTECTED BY
R.S.O. FIRE SHUTTER
assume full responsibility and bear costs for any corrections or
W 2'-4" ABOVE damages resulting from his work.
WS4 H 9'-0"
AFF 2'-0" The copyright of this drawing is vested in Contempo Studio and it
7'-6"
R.S.O. may not be reproduced in whole or part or used for the manufacture
(TYP.)
W 8'-0"
9'-0"
9'-0"
R.S.O. WS5 2'-11" R.S.O. of any article without the express written permission.
5'-6"
5'-6"
5'-6"
5'-6"
W 7'-0" H 9'-0" W 2'-0"
WS2 WS7
11'-0"
H 9'-0" 2'-2" AFF 2'-0" H 5'-6"
AFF 2'-0" AFF 3'-6"
2'-2"
F.G.
2'-11"
CORNER WIND. R.S.O. R.S.O. R.S.O.
F.G. F.G.
PLAN VIEW
W 1'-8" WINDOW W 2'-0" W 2'-0"
WS6 PROTECTED BY WS8 WS9
3'-6"
3'-6"
3'-6"
3'-6"
H 5'-6" H 5'-6" H 5'-6"
4'-9 1/2"
FIRE SHUTTER
F.G. SPANDREL BLACK 3'-6" 3'-6" 3'-6"
2'-0"
R.S.O. R.S.O. AFF ABOVE AFF AFF
3'-3 1/2"
W 2'-8" W 2'-4" CORNER WIND. GLASS PANEL
2'-11"
SECOND FLOOR WS1 9'-0" WS3 9'-0" PLAN VIEW
23'-3 1/2"
23'-3 1/2"
H H
AFF 2'-0" AFF 2'-0" F.G.
105.16
2'-0" 2'-0"
1'-0"
1'-0"
WINDOW
FIRST F. CEILING
3'-0"
18'-0" 4'-0" PROTECTED BY
FIRE SHUTTER
104.77 ABOVE
8'-0"
R.S.O. W 8'-0"
WF2 H 11'-0"
11'-0"
11'-0"
11'-0"
0" R.S.O.
AFF W 2'-2"
10'-0"
10'-0"
WF1 H 11'-0"
AFF 0"
F.G.
10'-0"
R.S.O.
R.S.O. W 2'-0" R.S.O. W 3'-0"
W 2'-0" WF5
3'-0"
WF3 H 10'-0" WF4 H 20'-3"
H 10'-0"
AFF 0" AFF 3'-0"
FIRST FLOOR F.G. F.G. F.G.
F.G. F.G. AFF 0"
2'-0 1/4"
[0.62 m]
R.S.O.
101.42 W 4'-0" BASEMENT CEILING 2'-6" 2'-6"
GARAGE DF1
1'-0"
1'-0"
H 11'-0"
R.S.O. W 2'-2"
101.02
100.80 WF1 H 11'-0"
R.S.O.
W 18'-0" AFF 0"
DFG
5'-0"
5'-0"
H 10'-0"
10'-0"
R.S.O. R.S.O.
W 2'-6" W 2'-6"
4'-0"
4'-0"
WB1 H 5'-0" WB2 H 5'-0"
AFF 4'-0" AFF 4'-0"
BASEMENT
97.98
2'-0"
2'-0"
2'-0"
F.G. F.G.
2'-0" 2'-0" 2'-0" 5'-0" WB3 4' - 0" 2' - 6" 5' - 0" WS8 3' - 6" 2' - 0" 5' - 6"
WB4 4' - 0" 2' - 6" 5' - 0" WS9 3' - 6" 2' - 0" 5' - 6"
WF1 0' - 0" 2' - 2" 11' - 0" WS10 1' - 0" 4' - 0" 10' - 0"
WF2 0' - 0" 8' - 0" 11' - 0" WS11 3' - 6" 2' - 0" 5' - 6"
R.S.O.
5'-6"
5'-6"
5'-6"
5'-6"
10'-0"
W 14'-0" WF3 0' - 0" 2' - 0" 10' - 0" WS12 3' - 6" 2' - 0" 5' - 6"
11'-0"
DF17
H 11'-0"
WF4 0' - 0" 2' - 0" 10' - 0" WS13 3' - 6" 5' - 0" 5' - 6"
F.G. WF5 3' - 0" 3' - 0" 20' - 3" WS14 3' - 6" 2' - 0" 5' - 6"
R.S.O. W 4'-0" R.S.O. R.S.O. R.S.O. WF8 0' - 0" 8' - 0" 11' - 0" WSK2 6' - 0" 2' - 6"
WS10 R.S.O. W 2'-0" W 2'-0" W 2'-0" W 5'-0"
H 10'-0" WS14 WS11 WS12 WS13 WF9 3' - 0" 2' - 0" 6' - 0"
3'-6"
3'-6"
3'-6"
3'-6"
H 5'-6" H 5'-6" H 5'-6" H 5'-6"
AFF 1'-0" AFF 3'-6" AFF 3'-6" AFF 3'-6"
AFF 3'-6" WF10 3' - 0" 2' - 0" 6' - 0"
1'-0"
SECOND FLOOR
WS1 2' - 0" 2' - 8" 9' - 0"
105.16 WS2 2' - 0" 7' - 0" 9' - 0"
WS3 2' - 0" 2' - 4" 9' - 0"
2'-0"
2'-0"
FIRST F. CEILING 2'-0" 2'-0"
16'-0" 8'-0" WS4 2' - 0" 2' - 4" 9' - 0"
104.77
WS5 2' - 0" 8' - 0" 9' - 0"
R.S.O. WS5.1 11' - 0" 8' - 0" 3' - 3 1/2"
8'-0"
W 8'-0"
WF8 H 11'-0"
6'-0"
6'-0"
11'-0"
11'-0"
R.S.O.
AFF 0"
W 16'-0"
DF2
H 11'-0" Door Schedule
F.G.
3'-0"
3'-0"
H H
AFF 3'-0" AFF 3'-0"
DF1 4' - 0" 11' - 0"
F.G.
FIRST FLOOR DF2 16' - 0" 11' - 0"
101.42 DF17 14' - 0" 11' - 0"
2'-6"
DFB7 8' - 0" 9' - 0"
1'-0"
1'-0"
BASEMENT CEILING
DFB9 3' - 0" 9' - 0"
101.02 DFB9 3' - 0" 9' - 0"
A
DFB9 3' - 0" 9' - 0" The undersigned has reviewed and takes responsibility for this
5'-0"
5'-0"
INTERIOR
design, and has the qualifications and meets the requirements set out in
INTERIOR
DFB10 2' - 6" 9' - 0" the Ontario Building Code to design the work shown on the attached
B
INTERIOR
EXTERIOR EXTERIOR
EXTERIOR documents:
PLAN VIEW
PLAN VIEW PLAN VIEW
DFB10 2' - 6" 9' - 0"
QUALIFICATION INFORMATION
CONSTRUCTION
CONSTRUCTION NOTE DFB10 2' - 6" 9' - 0"
R.S.O. R.S.O.
NOTE Required unless design is exempt under 3.2.4.3.(5) Division C of
CONSTRUCTION CONSTRUCTION
DFB10 2' - 6" 9' - 0"
EXTERIOR
W 2'-6" W 2'-6" 10
INTERIOR
NOTE NOTE the Ontario Building Code.
4'-0"
4'-0" 4'-0"
OPERATION
WINDOW FG
OPERATION WINDOW DFB10 2' - 6" 9' - 0"
AFF AFF MARIN ZABZUNI 45250
(TILL & TURN) (SWING) (SLIDE) DFB11 3' - 0" 9' - 0" NAME SIGNATURE BCIN
SIDE VIEW EXTERIOR ELEVATION VIEW EXTERIOR ELEVATION VIEW FG = FIXED EXTERIOR ELEVATION VIEW EXTERIOR "B" EXTERIOR "A"
GLASS ELEVATION VIEW ELEVATION VIEW
DFB11 3' - 0" 9' - 0" REGISTRATION INFORMATION
CORNER WINDOW
EXTERIOR DFB11 3' - 0" 9' - 0" Required unless design is exempt under 3.2.4.7. Division C
of the Ontario Building Code.
DFB11 3' - 0" 9' - 0"
INTERIOR CONTEMPO STUDIO 46972
ELEVATION VIEW
TYPE MARK
DFB11 3' - 0" 9' - 0" FIRM NAME BCIN
EXTERIOR
INTERIOR
CONSTRUCTION NOTE CONSTRUCTION WINDOW
10 NOTE WITH OF
WINDOW
DFB12 2' - 4" 9' - 0"
OPERATION WINDOW
REAR (NORTH) WINDOW ELEVATION LEFT (WEST) WINDOW ELEVATION 10 WF1 W 3' - 0" DFB12 2' - 4" 9' - 0"
3 4 (AWNING) SKYLIGHT WINDOW H 5' - 0" HEIGHT OF
WINDOW
DFB12 2' - 4" 9' - 0"
3/16" = 1'-0" 3/16" = 1'-0" SIDE VIEW EXTERIOR ELEVATION VIEW PLAN VIEW
AFF 5' - 0"
ABOVE OF
WINDOW SYMBOL
FINISH FLOOR
DFB13 2' - 4" 9' - 0"
DFB13 2' - 4" 9' - 0"
INTERIOR
INTERIOR
INTERIOR
DFB14 2' - 4" 9' - 0"
EXTERIOR EXTERIOR EXTERIOR
PLAN VIEW PLAN VIEW PLAN VIEW CONSTRUCTION
NOTE
DFB14 2' - 4" 9' - 0"
8'-0"
TYPE MARK
DOOR WITH OF
DFB14 2' - 4" 9' - 0"
WINDOW
DFB14 2' - 4" 9' - 0"
1'-0"
FG = FIXED
GLASS
A11
5 PROCEEDING WITHT HE WORK
Drawing number:
3/16" = 1'-0" -VERIFY DIMENSIONS OF ALL ROUGH OPENINGS (R.O.) AND MASONRY
OPENINGS (M.O.) IN FIELD