ISBN 978-0-626-30596-3
SANS 10400-D:2016
Edition 3.1
WARNING
This document references other
documents normatively.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
Table of changes
Change No. Date Scope
Amdt 1 2016 Amended to delete the note to the scope, and to remove the annex
on National Building Regulations Part D: Public Safety.
Acknowledgement
The SABS Standards Division wishes to acknowledge the work of the South African Institution of
Civil Engineering in updating this document.
Foreword
This South African standard was approved by National Committee SABS/TC 060, Standards which
address the National Building Regulations (NBRS), in accordance with procedures of the
SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement.
A vertical line in the margin shows where the text has been technically modified by amendment
No. 1.
Compliance with the requirements of this document will be deemed to be compliance with the
requirements of part D of the National Building Regulations, issued in terms of the National Building
Regulations and Building Standards Act, 1977 (Act No. 103 of 1977).
Compliance with this document cannot confer immunity from legal obligations.
SANS 10400 consists of the following parts, under the general title The application of the National
Building Regulations:
Part C: Dimensions.
Part G: Excavations.
Part H: Foundations.
Part J: Floors.
Part K: Walls.
Part L: Roofs.
Part M: Stairways.
Part N: Glazing.
© SABS
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
Foreword (concluded)
Part O: Lighting and ventilation.
Part P: Drainage.
© SABS
1
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
Contents
Page
Acknowledgement
Foreword
1 Scope .................................................................................................................................. 3
3 Definitions ........................................................................................................................... 3
4 Requirements ...................................................................................................................... 4
Bibliography ............................................................................................................................ 7
© SABS
2
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
1 Scope
This part of SANS 10400 provides deemed-to-satisfy requirements for compliance with part D
(Public Safety) of the National Building Regulations.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies. Information on currently valid national
and international standards can be obtained from the SABS Standards Division.
SANS 10400-A, The application of the National Building Regulations – Part A: General principles
and requirements.
SANS 10400-B, The application of the National Building Regulations – Part B: Structural design.
SANS 10400-S, The application of the National Building Regulations – Part S: Facilities for persons
with disabilities.
3 Definitions
For the purposes of this document, the definitions given in SANS 10400-A (some of which are
repeated for convenience) and the following apply.
3.1
deemed-to-satisfy requirement
non-mandatory requirement, the compliance with which ensures compliance with a functional
regulation
3.2
functional regulation
regulation that sets out in qualitative terms what is required of a building or building element or
building component in respect of a particular characteristic, without specifying the method of
construction, dimensions or materials to be used
© SABS
3
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
3.3
interconnected complex
complex of multiple dwelling units, such as terraced or multi-storey complexes, or cluster or
retirement-village-type developments (or both), where management of common property usually
resides with (but is not limited to) a management body
3.4
site
erf, lot, plot, stand or other piece of land on which a building has been, is being or is to be erected
3.5
street boundary
boundary of a site which abuts any street
4 Requirements
4.1 General
The functional regulations contained in part D of the National Building Regulations shall be deemed
to be satisfied where a change in level, the design of ramps and driveways, or access to swimming
pools and swimming baths comply with the requirements of 4.2, 4.3 and 4.4, respectively. Amdt 1
4.2.1 Any balustrade or wall provided to protect a change in level shall comply with the
requirements of SANS 10400-B.
4.2.2 The edge of any balcony, bridge, flat roof or similar place more than 1 m above the adjacent
ground or floor level shall be provided with a balustrade or parapet wall not less than 1 m in height,
unless unauthorized access of persons thereto has been excluded by a physical barrier properly
erected and maintained.
4.2.3 In the case of an interior balcony or a mezzanine floor, such balcony or floor shall be
provided with a balustrade or wall not less than 1 m in height, provided that where such balcony or
floor is used for public seating in rows such height may be reduced to not less than 800 mm
opposite the seating in the front row.
4.2.4 A balustrade or wall provided as protection at a change in level in any occupancy classified
as E2, E3, E4, H1, H2, H3, H4 or H5 shall not have any opening that permits the passage of a
100 mm diameter ball, provided that such protection in any occupancy that is not an occupancy
classified as E2, E3, E4, H1, H2, H3, H4 or H5, shall consist of at least a handrail and one other rail
midway between such handrail and the floor.
a) ramp or driveway used by motor vehicles shall have a gradient of not more than 1 in 25 within a
distance of 5 m from any street boundary crossed by such ramp or driveway (see figure 1);
b) ramp or driveway used by pedestrians other than those ramps or driveways provided for the use
of persons in wheelchairs, shall have a gradient of not more than 1 in 8 (see figure 1);
© SABS
4
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
c) ramp provided for the use of persons in wheelchairs shall be in accordance with the
requirements of SANS 10400-S; and
d) ramp designed for use by both vehicles and pedestrians shall have a walkway not less than
1,2 m wide which shall be provided with a kerb not less than 150 mm high.
4.4.1 A wall or fence shall be provided by the owner of a site which contains a swimming pool or a
swimming bath to ensure that no person can have access to such pool or bath from any street or
public place or any adjoining site other than through (see figure 2)
a) a self-closing and self-latching gate with provision for locking in such wall or fence, or
4.4.2 A wall or fence shall be provided in any interconnected complex which contains a swimming
pool or swimming bath to ensure that no person can have access to such pool or bath from any
street or public place or anywhere within the complex other than through a self-closing and
self-latching gate with provision for locking in such wall or fence.
4.4.3 Such wall or fence and any such gate therein shall be not less than 1,2 m high measured
from the ground level, and shall not contain any opening that will permit the passage of a 100 mm
diameter ball.
4.4.4 The constructional requirements of any steel fence or gate shall comply with the
requirements in SANS 1390.
NOTE Additional methods, including pool covers and warning devices, for the protection of children from the
hazards of swimming pools are provided in SANS 10134.
© SABS
5
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
© SABS
6
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
SANS 10400-D:2016
Edition 3.1
Annex A
Deleted by amendment No. 1.
Bibliography
SANS 10134, The safeness of private swimming pools.
______________
© SABS
7
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.
The standard must reside on an internal network or intranet and may only be used for reference purposes in compliance with SABS
copyright rules. The standard or parts thereof may not be distributed in any form without permission from the SABS.
The objective of the SABS Standards Division is to develop, promote and maintain South African
National Standards. This objective is incorporated in the Standards Act, 2008 (Act No. 8 of 2008).
South African National Standards are updated by amendment or revision. Users of South African
National Standards should ensure that they possess the latest amendments or editions.
The SABS continuously strives to improve the quality of its products and services and would
therefore be grateful if anyone finding an inaccuracy or ambiguity while using this standard would
inform the secretary of the technical committee responsible, the identity of which can be found in
the foreword.
The SABS offers an individual notification service, which ensures that subscribers automatically
receive notification regarding amendments and revisions to South African National Standards.
Tel: +27 (0) 12 428 6883 Fax: +27 (0) 12 428 6928 E-mail: [email protected]
Buying Standards
Contact the Sales Office for South African and international standards, which are available in both
electronic and hard copy format.
Tel: +27 (0) 12 428 6883 Fax: +27 (0) 12 428 6928 E-mail: [email protected]
South African National Standards are also available online from the SABS website
http://www.sabs.co.za
Information on Standards
The Standards Information Centre provides a wide range of standards-related information on both
national and international standards. The Centre also offers an individual updating service called
INFOPLUS, which ensures that subscribers automatically receive notification regarding
amendments to, and revisions of, international standards.
Tel: +27 (0) 12 428 7911 / 0861 27 7227 Fax: +27 (0) 12 428 6928 E-mail: [email protected]
Copyright
The copyright in a South African National Standard or any other publication published by the SABS
Standards Division vests in the SABS or, in the case of a South African National Standard based on
an international standard, in the organization from which the SABS adopted the standard under
licence or membership agreement. In the latter case, the SABS has the obligation to protect such
copyright. Unless exemption has been granted, no extract may be reproduced, stored in a retrieval
system or transmitted in any form or by any means without prior written permission from the SABS
Standards Division. This does not preclude the free use, in the course of implementing the
standard, of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any purpose other than implementation, prior written permission must be
obtained.
Details and advice can be obtained from the Manager – Standards Sales and Information Services.
Tel: +27 (0) 12 428 6883 Fax: +27 (0) 12 428 6928 E-mail: [email protected]
© SABS. This non-printable standard is exclusively for approved users of the SABS’ Complete Collection of Standards and Related Documents.