KH322B Controller User Manual
1. Buttons introduction
[Wash] button
Press this button to switch among Normal/Delicate/Heavy washing
ways and stopping washing.
[Extract] button
Switch between starting high extract 1~4 and stopping high extract
1~4 by pressing this button.
[Supply] button
Under “manual” mode, the supply1~3 will work for 30 seconds by
pressing this button and you also can stop the supply1~3 during
supply1~3 working by pressing this button.
[Start/Confirm] button
Under “Lock” status, press this button to start executing the selected
program;
Under parameter setting status, press this button to confirm the
3/ 16
KH322B Controller User Manual
prompting message;
Under “Edit” status, press this button to clear the selected program;
Under “Door closed” status, press this button to start the selected
program;
[+] button
Under parameter setting status, press this button to modify the
prompting message;
Under “Edit” status, press this button 3s to insert step;
[-] button
Under parameter setting status, press this button to modify the
prompting message;
Under “Edit” status, press this button 3s to delete step;
Stop / cancel key
1) exit a menu,
2) in the manual state, press this button to stop the current operation.
3) in the "auto" state, press this button to stop the current program.
4 when setting parameters or programming, press this button to
indicate the confirmation prompt.
[↑] button
Under parameter setting status, press this button to select the
prompting message;
Under “Edit” status, press this button to modify;
[↓] button
Under parameter setting status, press this button to select the
prompting message;
Under “Edit” status, press this button to modify;
2. Operation instructions
2.1. Manual mode
2.1.1. Manual mode
While door is closed or locked, press any key below may enter the "manual" :"cold water" ,"hot
water", "heating","supply","extract", "drain", "wash".
Manl Pr01
StandardWash
04:50
10/20cm 20/50℃
4/ 16
KH322B Controller User Manual
Manu Pr01
StandardWash
04:50
10/20cm 20/70℃
2.1.3. Modify temperature
In the "manual" mode, press 《↑》 《↓》button to switch the cursor to the position of temperature
display, and then press the "+" "-" button can modify the setting value, automatically after 5 seconds to
exit the setting interface.
Manu Pr01
StandardWash
04:50
10/20cm 20/70℃
2.1.4. Modify level
In the "manual" mode, press《↑》 《↓》button to switch the position to the level of setting level, then
press the "+" "-" button can modify the setting value, automatically after 5 seconds to exit the setting
interface. You can also press the "level" button to change the set level, switch low level, medium level,
high level, any level(any level means level is decided by time).
Manu Pr01
StandardWash
04:50
10/20cm 20/70℃
2.1.5. Stop
In the manual operation, press the "stop" button to stop the machine.
2.2. Automatic mode
2.2.1. Auto mode
In the idle page, press "+" "-" button to select the program, press the "start" button to start running
the program currently selected.
5/ 16
KH322B Controller User Manual
2.4. Alarm
Idle Pr01
#01Doorstatus error
04:50
10/20cm 20/70℃
3. Programming instructions
3.1. Create a new program
3.1.1. Enter programming
In the "Idle" status, press 《Edit》3s to enter the "programming" interface.
3.1.2. Delete program
After enter step edit page, press and hold “start” button for three seconds to delete all the steps of the
selected program .
3.1.3. Delete step
After selecting the step number, press and hold “delete” button for three seconds to delete the step.
3.1.4. Select step number
In the step edit page, press 《start》to switch cursor to the position of step number and the step
number will be highlighted like :S01. Press《↑》《↓》 to select step number;
6/ 16
KH322B Controller User Manual
3.1.5.2.Edit time
Press《start》 button to switch the cursor to the position of step time.
Press《↑》《↓》button to modify the time of step.
P01 S01 prewash
04:50 18CM 70℃
Normal.W cold
--- Spy: ---
3.1.5.3.Edit temperature
7/ 16
KH322B Controller User Manual
4. Parameter setting
After power on, press 《start》3s to enter the "parameter setting interface":
BASIC PARAMETERS
1:Set to default
2:Machine setup
Stop3S=Quit
Enter the parameter setting interface, press the《↑》《↓》to select the parameter items, press
the "start" button to enter sub items. Press《+》 《-》to modify parameter value.
8/ 16
KH322B Controller User Manual
9/ 16
KH322B Controller User Manual
10/ 16
KH322B Controller User Manual
11/ 16
KH322B Controller User Manual
12/ 16
KH322B Controller User Manual
Hi 1 Speed~Hi 3
25:High extract 2 speed 700rpm Speed of high extract 2.
Speed
Hi 2 Speed~Hi 4
26:High extract 3 speed 800rpm Speed of high extract 3.
Speed
Hi 3 Speed~Max
27:High extract 4 speed 900rpm Speed of high extract 4.
Hi Extract Speed
28:Max speed of mid Mid extract
400rpm Max speed of mid extract.
extract speed ~600 rpm
29:Max speed of high High extract 1
999rpm Max speed of high extract.
extract speed ~999 rpm
Can't unlock the door when temperature is
1:Unlock door temperatu. 50℃ 0~99℃
higher than safety temperature.
Can't unlock the door when level is higher
2:Unlock door level 10cm 0~99cm
than safety level.
Open: Door lock valve is opened while
locked.
9:Door 3:Door lock valve status N.O. N.C.,N.O.
Close: Door lock valve is closed while
lock
locked.
setup
When using a door pin, if the door pin is
4:DoorPin max time 10Seconds 0-99 not locked beyond this time, there is an
error.
Series,
5:Door lock type Series Door lock type : Dual,Series and Pulsed.
Pulsed,Dual
6: Pulse unlock time 10 seconds 0-99seconds Time when the pulse lock is opened.
4.1. Machine settings
In the parameter settings main interface, select "1: Machine setup", press "start" button to enter
the machine settings interface.
13/ 16
KH322B Controller User Manual
5. Fault diagnosis
5.1. Fault reset
Manual or automatic operation, the machine failure, enter the fault alarm interface, stop all actions.
Fault alarm interface second lines display fault information. When there is a fault, the buzzer
sounded, press the stop key, the buzzer sound, and then press the stop key to re detect the fault,
such as the failure has not been resolved, continue to alarm; if the fault has been resolved, you can
continue to run.
5.2. Fault information and troubleshooting
Reset
way
Error MA
NO. Error name A Reasons Trouble shooting
type NU
ut
AL
o
LY
14/ 16
KH322B Controller User Manual
15/ 16