DATASHEET
Split-Phase Hybrid/AC
H1&AC1-3.8-US / 5.7 / 7.6 / 9.6 / 11.4
US SERIES
Fox ESS storage solutions are available with
advanced and intuitive app based remote control
and monitoring functionality.
EASY INSTALLATION HIGH VOLTAGE TYPE 4X REMOTE MONITORING
Flexible configuration, plug and Compatible with high-voltage Engineered to last with Monitor your system
play set-up. batteries for maximum maximum flexibility. Suitable remotely via smartphone
round-trip efficiency. for outdoor installation. app or web portal.
BATTERY EXPANSION
EASY UPGRADE
REFINED - POWERFUL - FLEXIBLE
+
Expand your system easily by simply adding
additional batteries. There are 6 battery
size options, and 7 batteries can be
installed in series, providing up to 27.8 kWh of
storage capacity.
For more about the Fox ESS range, visit:
us.fox-ess.com
TECHNICAL SPECIFICATIONS
AC Inverter Model: AC1-3.8-US AC1-5.7-US AC1-7.6-US AC1-9.6-US AC1-11.4-US
Hybrid Inverter Model: H1-3.8-US H1-5.7-US H1-7.6-US H1-9.6-US H1-11.4-US
PV INPUT (ONLY FOR HYBRID)
Max. Solar STC Power [W] 7600 11400 15200 19200 22800
Max. Input Voltage [V] 600
Start-up Input Voltage [V] 100
Rated Input Voltage [V] 380
MPPT Opera�ng Voltage Range [V] 80~550
MPPT Opera�ng Voltage Range [V] (Full Load) 204~500 204~500 271~500 257~500 305~500
Max. Input Current [A] 28 / 14 28 / 14 / 14
Max. Short-circuit Current [A] 44 / 22 44 / 22 / 22
No. of Independent MPP Trackers 2 3
No. of Strings per MPP Tracker 2/1 2/1/1
BATTERY CONNECTION
Ba�ery Type Lithium Ba�ery (LFP)
Ba�ery Voltage Range [V] 85~460
Rated Ba�ery Voltage [V] 360
Max. Con�nuous Charge / Discharge Current [A] 50
Max. Con�nuous Charge / Discharge Power [W] (for H1) 5700/4180 8550/6270 11400/8360 14400/10560 17100/12540
(for AC1) 3800/4180 5700/6270 7600/8360 9600/10560 11400/12540
Max. Discharge Current (60s) [A] 60
BMS Communica�on Interface CAN 2.0
AC INPUT AND OUTPUT (GRID)
Max. AC Input Power [VA] 3800 5700 7600 9600 11400
Max. AC Input Current [A] 16 24 32 40 48
Input Voltage Range [V] 211~264
Input Frequency Range [Hz] 57~63
Rated Output Power [W] 3800 5700 7600 9600 11400
Max. Output Apparent Power [VA] 3800 5700 7600 9600 11400
Rated Output Current [A] 15.8 23.8 31.7 40.0 47.5
Max. Output Current [A] 15.8 23.8 31.7 40.0 47.5
Rated Grid Voltage [V] 240 (211~264)
Rated Grid Frequency [Hz] 57~63
Power Factor >0.99 (Adjustable from 0.8 leading to 0.8 lagging)
THDi [%] <3 @rated power
AC OUTPUT (BACKUP)
Rated Output Power [W] 3800 5700 7600 9600 11400
Rated output power @different ba�eries [W] 3800 @H2 Ba�ery 5700 @H2 Ba�ery 5760 @H2 Ba�ery 5760 @H2 Ba�ery 5760 @H2 Ba�ery
3800 @H3 Ba�ery 5700 @H3 Ba�ery 7600 @H3 Ba�ery 8640 @H3 Ba�ery 8640 @H3 Ba�ery
3800 @H4 Ba�ery 5700 @H4 Ba�ery 7600 @H4 Ba�ery 9600 @H4 Ba�ery 11400 @H4 Ba�ery
3800 @H5 Ba�ery 5700 @H5 Ba�ery 7600 @H5 Ba�ery 9600 @H5 Ba�ery 11400 @H5 Ba�ery
3800 @H6 Ba�ery 5700 @H6 Ba�ery 7600 @H6 Ba�ery 9600 @H6 Ba�ery 11400 @H6 Ba�ery
3800 @H7 Ba�ery 5700 @H7 Ba�ery 7600 @H7 Ba�ery 9600 @H7 Ba�ery 11400 @H7 Ba�ery
Max. Output Apparent Power [VA] 4180 6270 8360 10560 12540
Peak Output Apparent Power (10min) [VA] 4560 6840 9120 11520 13680
Peak Output Apparent Power (60s) [VA] 5130 7695 10260 12960 15390
Max. Con�nuous Output Current [A] 17.4 26.1 34.8 44.0 52.3
LRA [A] 110
Rated Output Voltage [V] 120 / 240
Rated Output Frequency [Hz] 60
Load Start Capacity ALRA 48 @H2 Ba�ery 48 @H2 Ba�ery 48 @H2 Ba�ery 48 @H2 Ba�ery 48 @H2 Ba�ery
72 @H3 Ba�ery 72 @H3 Ba�ery 72 @H3 Ba�ery 72 @H3 Ba�ery 72 @H3 Ba�ery
96 @H4 Ba�ery 96 @H4 Ba�ery 96 @H4 Ba�ery 96 @H4 Ba�ery 96 @H4 Ba�ery
110 @H5 Ba�ery 110 @H5 Ba�ery 110 @H5 Ba�ery 110 @H5 Ba�ery 110 @H5 Ba�ery
110 @H6 Ba�ery 110 @H6 Ba�ery 110 @H6 Ba�ery 110 @H6 Ba�ery 110 @H6 Ba�ery
110 @H7 Ba�ery 110 @H7 Ba�ery 110 @H7 Ba�ery 110 @H7 Ba�ery 110 @H7 Ba�ery
THDv ( Linear Load) [%] <3 @rated power
Imbalance for Split-Phase Loads [%] 100
EFFICIENCY
CEC Efficiency [%] 97.00
Max. Efficiency [%] 97.60
Max. Ba�ery Discharge Efficiency (BAT to AC) (@full load, 340Vdc) [%] 97.40
PROTECTION
Insula�on Monitoring YES
Residual Current Monitoring YES
DC Reverse Polarity Protec�on YES
An�-islanding Protec�on YES
AC Short-circuit Protec�on YES
AC Overcurrent / Overvoltage Protec�on YES
DC Switch YES
SPD DC: Type II / AC: Type II
AFCI YES
GENERAL DATA
Dimensions (W*H*D) [inch] 18.2*25.9*9.2 (462*658*234.5mm)
Weight [Ibs] 83.8 (38kg)
Installa�on Wall-mounted
Topology Transformerless
Cooling Method Natural convec�on
Noise Emission [dB] <35
Max. Opera�ng Al�tude [�] 9843 (3000 m), dera�ng above 6560 (2000 m)
Opera�ng Temperature Range [°F] -13 ~ +140 (-25°C ~ +60°C), dera�ng above 104 (40°C)
Humidity [%] 0 ~ 100 (No Condensa�on)
Protec�on Degree Type 4X
Standby consump�on [W] <25
Maximum number of Inverters (Parallel) 4
Monitoring Module WiFi, LAN
Communica�on CAN2.0, RS485, Meter, CT, ISO alarm, SUNSPEC
Display LED, App, Website
Warranty [Year] 12.5
STANDARD COMPLIANCE (MORE AVAILABLE UPON REQUEST)
Safety UL1741 SA, UL 1741 SB, UL1741 CRD, HECO SRD-V2.0, CSA C22.2 No.107.1-16, UL1998, UL1699B, Rule 21
EMC FCC part15 CLASS B
Grid Regula�on IEEE1547-2018, IEEE1547a-2020, IEEE1547.1-2020
Version 4.1 | 2024/05/29