6.
13 Overload system
Scanclimber hoists are equipped with an
electronic overload system that detects
the possible overload and cuts off the
safety circuit if the hoist is overloaded.
The system consist of a dispaly inside the
hoits cage, load sensors on the lifting unit
and a circuit board in electric box.
Display
Overload system display
The display on the hoist control board
shows the actual hoist load.
Calibration
The overload system can be calibrat- • Push button SW3. The green LED D19 is
ed either with calibration load or au- on a short time.
tomatically without loading the hoist. • Push button SW1 to stop calibration.
The automatic calibration is possible The yellow LED D21 turns off. The red
if the system is calibrated earlier with LED D20 stays on.
calibration load. • Remove the load from the cage. The
The system is calibrated with the cali- red led D20 turns off.
bration switches on the calibration • Load the cage again to its maximum
system circuit board. load. Check that the red LED D20
is on and the hoist safety circuit is
Calibration With Load disconnected.
The system is first calibrated without Automatic Calibration
load and then with full load.
• Find the circuit board in the The overload system can be
electric box. calibrated automatically only if the
• Push button SW1. Red LED D20 system is calibrated with load earlier.
and yellow LED D21 start to blink.
• Push button SW2. Red LED D20 • Find the circuit board in the electric
stays on. box.
• Load the cage with maximum • Push button SW2. The red LED stays on
load. a short time.
• Push button SW3. The green LED • Load the cage to its maximum load
D19 is on a short time. and check that the red LED D20
• Push button SW1. The yellow LED is on and the hoist safety circuit is
D21 turns off. The red LED D20 disconnected.
stays on.
V44+02E_02.17 Erection of the hoist Series-48 Hoist Pos 6
65
Overload system circuit board
Series-48 Hoist Pos 6 Erection of the hoist V44+02E_02.17
66