Catalogo Bomba Z
Catalogo Bomba Z
Z10, Z12
Series
10” - 12” SUBMERSIBLE
ELECTRIC PUMPS
200 300 400 500 600 700 800 900 1000 Q [US gpm] 2000
800
600 2000
500
400
300 1000
800
200
600
500
H [m]
H [ft]
400
Z10150
Z10220
Z10275
Z12340
Z12420
100
300
80
60 200
50
40
30 100
80
20
60
50
40
10
30
8
6 20
5
4
03830_B_CH
3
30 40 50 60 70 80 90 100 Q [m /h] 200 300 400 500 600
500 600 800 1000 Q [l/min] 2000 3000 4000 5000 6000 8000 10000
2
CONTENTS
3
4
10” MARKET SECTORS
Submersible AGRICULTURAL, INDUSTRIAL, MUNICIPAL.
Electric APPLICATIONS
APPLICATIONS
Pumps • Water supply from deep wells.
• Pressure boosting and water distribution in civil and
industrial systems.
Z10150 • Supply of surge tanks and reservoirs.
Z10220 • Firefighting and washing systems.
Z10275 • Water table level control.
• Irrigation.
Series
SPECIFICATIONS
SPECIFICATIONS • Maximum number of starts per hour:
PUMP 15 (L6W), 10 (L8W) 8 (L10W) 4 (L12W).
• Delivery
Delivery: up to 350 m3/h. • Maximum temperature of water in
• Head
Head: up to 545 m. contact with motor:
• Maximum pump overall diameter L6W, L8W, L10W and L12W 30°C.
(2 cable covers included): 271 mm. • Special versions
versions: AISI 316 and
• Maximum electric pump immersion Duplex materials, HT for applications
depth: 350 m with L6W, L8W, L10W in high temperature environments
and L12W motors. (up to 60°C) or under inverter.
• The content of sand should not exceed
50 g/m3, higher contents up to 100 g/m3 CONSTRUCTION
can be admitted, if wear is tolerated. FEATURES
FEATURES
• Horizontal installation possible (it is PUMP
recommended to have an incline of at • Robust but lightweight, easy to
least 3° with the motor on the lowest maintain and with high corrosion
position). resistance.
• Standard delivery outlet: • Impeller and diffusers made of
Rp 6” according to EN 10226. stainless steel castings.
• Motor power: from 11 to 300 kW. • Delivery head and suction support of
stainless steel castings.
MOTOR • Stainless steel non return valve
• L6W, L8W, L10W and L12W integrated, spring equipped.
rewindable water filled three-phase • Stainless steel shaft.
motors. • Guide bearings and wear rings ensure
• Three-phase version
version: high reliability and long lasting
L6W: 4 to 37 kW 380-415 V, 50 Hz. hydraulic performances.
L8W: 30 to 93 kW 380-415 V, 50 Hz. • The new design ensures high efficiency
L10W: 93 to 150 kW 380-415 V, and low power consumption
50 Hz. • Special versions
versions: ZR10 made of
L12W: 185 to 300 kW 380-415 V, Duplex stainless steel.
50 Hz. • Coupling according to NEMA standard
• Maximum supply voltage variations: for 6” and 8” motor, with key
L6W, L8W, L10W, L12W 400V ±10%. connection for 10” and 12” motor.
• Horizontal operation
operation:
L6W, all versions are designed for ACCESSORIES
ACCES SORIES
horizontal installation, provided that • Coupling flange.
the direction of the axial thrust • Panels.
generated by the impellers is always • Drop cables.
from the pump to the motor. • Cooling shrouds.
L8W, L10W, L12W available on requests • Temperature sensor PT 100 / PTC
PTC.
for all versions.
5
TTABELLA
ABLE OFMATERIALI
MA Z10
TERIALS
MATERIALS Z10
COMPONENT MATERIAL DESIGNATION
EUROPE USA
Delivery head / Valve Casing Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Valve Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Valve seat NBR 90
Valve spring Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
Diffuser / Bowl Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Diffuser O-Ring NBR 70
Impeller Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Taperlock Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
Wear ring POM
Lower support / Suction Casing Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Suction strainer Stainless steel DIN 17440-X6CrNiMoTi17-12-2 (1.4571) AISI 316Ti
Pump shaft Stainless steel EN 10088-1-X17CrNi16-2 (1.4057) AISI 431
Coupling Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
Bearing bush EPDM + LOXAMID ®
Thrust Bearing PTFE + 25% carbon
Screw, stud, nut Stainless steel ISO 3506-1/2 A4-70 AISI 316
Cable protection Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI 304
MOTOR CODE
REDUCTION TYPE
NUMBER OF REDUCED STAGES
NUMBER OF STAGES
FLOW RATE IN m3/h
TYPE OF PUMP (R = DUPLEX VERSION)
BLANK = 50 Hz
6 = 60 Hz
6
Z10 SERIES
HYDRA ULIC PERFORMANCE RANGE A
HYDRAULIC T 50 Hz
AT
Z10 ∼ 2900 [rpm] ISO 9906 - Annex A
200 300 400 500 600 700 800 1000 Q [Imp gpm]
200 300 400 500 600 700 800 1000 Q [US gpm]
800
700
600 2000
500
H [ft]
400
300 1000
800
700
200
600
H [m]
500
400
100
300
Z10150
Z10220
Z10275
80
70
60 200
50
40
30 100
80
70
20
60
50
40
10
30
8
7
6 20
5
03829_B_CH
3
30 40 50 60 70 80 90 100 200 300 Q [m400/h]
7
Z10150 SERIES, 1 TO 3 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10150 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 667 1333 2000 2500 3000
TYPE POWER m3/h 0 40 80 120 150 180
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10150-2p50-1-en_a_td
8
Z10150 SERIES, 1 TO 3 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
H [ft]
Factor de
Facteur decorrection
correctionduduηη
Correcting Factor of η
125 3 Stufen/etages/stages Coeff.
3/2A 400
1/1A,1/1B,1/1C 0,98
3/2B
2/2A,2/2B,2/2C 0,99
3/2C
100
300
2/2A
75 2/2B
2/2C 200
50
1/1A
1/1B
1/1C 100
25
0 0
50
PP [kW]
3 60
3/2A
PP [HP]
40
3/2B
3/2C
30 40
2/2A
2/2B
20
2/2C
1/1A 20
10 1/1B
1/1C
0 0
12 100
30 η
8 80
NPSH [m]
NPSH [ft]
η [%]
20 NPSH
4 60
10
0 40
03820_A_CH
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
9
Z10150 SERIES, 4 TO 6 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10150 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 667 1333 2000 2500 3000
TYPE POWER m3/h 0 40 80 120 150 180
z10150-2p50-2-en_a_th
PUMP RATED
DIMENSIONS (mm WEIGHT
TYPE POWER
z10150-2p50-2-en_a_td
10
Z10150 SERIES, 4 TO 6 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
11
Z10150 SERIES, 7 TO 12 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10150 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 667 1333 2000 2500 3000
TYPE POWER m3/h 0 40 80 120 150 180
z10150-2p50-3-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10150-2p50-3-en_a_td
12
Z10150 SERIES, 7 TO 12 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A
ATT 50 Hz
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
13
Z10220 SERIES, 1 TO 3 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10220 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 1000 2000 3000 4000 5000
TYPE POWER m3/h 0 60 120 180 240 300
z10220-2p50-1-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10220-2p50-1-en_a_td
14
Z10220 SERIES, 1 TO 3 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
Z10220 ∼ 2900 [rpm] ISO 9906 - Annex A
Korrekturfaktor für η
3 Facteur de correction du η
125 3/2A Correcting Factor of η 400
3/2B Stufen/etages/stages Coeff.
1,1/1A,1/1B,1/1C 0,98
2,2/2A,2/2B,2/2C 0,99
100
H [m]
300
2
2/2A
H [ft]
75 2/2B
2/2C
200
50
1
1/1A
1/1B
1/1C 100
25
0 0
80
100
3
3/2A
60 80
PP [kW]
3/2B
PP [HP]
2 60
40 2/2A
2/2B 2/2C
40
1
20 1/1A
1/1B 20
1/1C
0 0
15 100
40 η
NPSH [m]
10 80
NPSH [ft]
30
η [%]
NPSH
20
5 60
10
0 40
03839_B_CH
15
Z10220 SERIES, 4 TO 7 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10220 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 1000 2000 3000 4000 5000
TYPE POWER m3/h 0 60 120 180 240 300
z10220-2p50-2-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10220-2p50-2-en_a_td
16
Z10220 SERIES, 4 TO 7 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
Z10220 ∼ 2900 [rpm] ISO 9906 - Annex A
7 1000
300 7/2B
900
6
250 6/2B
800
H [ft]
H [m]
5
700
5/2B
200
600
4
4/2A
4/2B 500
150
400
100
300
200
50
7
7/2B
150
PP [kW]
6 200
6/2B PP [HP]
5
150
5/2B
100
4
4/2A
4/2B 100
50
15 100
40 η
NPSH [m]
10 80
NPSH [ft]
30
η [%]
NPSH
20
5 60
10
0 40
03840_B_CH
17
Z10220 SERIES, 8 TO 12 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10220 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 1000 2000 3000 4000 5000
TYPE POWER m3/h 0 60 120 180 240 300
z10220-2p50-3-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10220-2p50-3-en_a_td
18
Z10220 SERIES, 8 TO 12 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A
ATT 50 Hz
Z10220 ∼ 2900 [rpm] ISO 9906 - Annex A
1800
12
12/2B
500
11 1600
11/2B
H [m]
10
10/2B 1400
H [ft]
400 9/1A
9/2B
1200
8
8/2B
300 1000
800
200
600
400
300 400
12
12/2B
11 350
250 11/2B
PP [HP]
10
PP [kW]
10/2B 300
9/1A
200 9/2B
8 250
8/2B
150 200
150
100
15 100
40 η
NPSH [m]
10 80
NPSH [ft]
30
η [%]
NPSH
20
5 60
10
0 40
03841_B_CH
19
Z10275 SERIES, 1 TO 3 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10275 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 1333 2500 3667 4667 5833
TYPE POWER m3/h 0 80 150 220 280 350
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10275-2p50-1-en_a_td
20
Z10275 SERIES, 1 TO 3 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
21
Z10275 SERIES, 4 TO 7 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10275 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 1333 2500 3667 4667 5833
TYPE POWER m3/h 0 80 150 220 280 350
z10275-2p50-2-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10275-2p50-2-en_a_td
22
Z10275 SERIES, 4 TO 7 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
23
Z10275 SERIES, 8 TO 11 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z10275 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 1333 2500 3667 4667 5833
TYPE POWER m3/h 0 80 150 220 280 350
z10275-2p50-3-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
D min = 300 mm
z10275-2p50-3-en_a_td
24
Z10275 SERIES, 8 TO 11 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A
ATT 50 Hz
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
25
Z10150 PUMP SERIES
DIMENSIONI E PESI SERIE Z10150 A 50 Hz
DIMENSIONS AND WEIGHTS
MAX Ø
PUMP POWER DIMENSIONS (mm) MIN.
WEIGHT
TYPE ABSORBED WELL
BY PUMP
kW (4) (1) (2) (3) mm
L C U kg
Z10150 01/1C 10,3 442 258 1600 48,1 270
Z10150 01/1B 12,8 442 258 1600 48,1 270
Z10150 01/1A 14,8 442 258 1600 48,1 270
Z10150 02/2C 20,5 658 258 1600 68,8 270
Z10150 02/2B 25,7 658 258 1600 68,8 270
Z10150 02/2A 29,6 658 258 1600 68,8 270
Z10150 03/2C 36,2 874 258 1600 89,5 270
Z10150 03/2B 41,3 874 258 1600 89,8 270
Z10150 03/2A 44,4 874 258 1600 89,8 270
Z10150 03 46,9 874 258 1600 89,8 270
Z10150 04/2C 51,8 1090 258 1600 110,5 270
Z10150 04/2B 57,0 1090 258 1600 110,5 270
Z10150 04 62,6 1090 258 1600 110,5 270
Z10150 05/2C 67,4 1306 258 1600 131,2 270
Z10150 05/2B 72,6 1306 258 1600 131,2 270
Z10150 05 78,2 1306 258 1600 131,2 270
Z10150 06/2C 83,0 1522 258 1600 151,9 270
Z10150 06/1B 91,0 1522 258 1600 151,9 270
Z10150 06 93,8 1522 258 1600 156,8 270
Z10150 07/3B 101,1 1738 258 1600 177,5 270
Z10150 07/1B 106,7 1738 258 1600 177,5 270
Z10150 08/3B 116,7 1954 258 1600 198,2 270
Z10150 08 125,1 1954 258 1600 198,2 270
Z10150 09/3B 132,4 2170 258 1600 218,9 270
Z10150 09 140,8 2170 258 1600 218,9 270
Z10150 10 156,4 2386 271 1600 240,4 300
Z10150 11 172,0 2602 271 1600 261,1 300
Z10150 12 187,7 2818 271 1600 281,8 300
DIMENSIONI ACCOPPIAMENTO MOTORI SERIE Z10 50 Hz
MOTOR COUPLING z10150p-50-en_a_td
MOTOR
DIMENSIONS (mm)
CONNECTION
N k d z b E H7 R l
6" (NEMA) 182 111,2 13,5 4 17 76,2 73 263
8" (NEMA) 182 152,4 18 4 17 127 101,45 263
10" 232 190,5 22 4 15 127 101,45 300
12" 232 190,5 22 4 15 127 126,85 300
DIMENSIONS (mm)
COUPLING Profile of gear coupling according to NEMA
NUMBER DIAMETRAL PRESSURE
OF TEETH PITCH ANGLE X
6" (NEMA) 15 16/32 30° 20
8" (NEMA) 23 16/32 30° 38
DIMENSIONS (mm)
COUPLING +0.084 +0.1 +0.05
F +0.059 H P +0.02 X
10" 42,85 47,6 9,5 84
12" 49.212 54,5 12,7 95
z10-mtcn-50-en_b_td
26
Z10220 PUMP SERIES
DIMENSIONI E PESI SERIE Z10200 A 50 Hz
DIMENSIONS AND WEIGHTS
MAX Ø
PUMP POWER DIMENSIONS (mm) MIN.
WEIGHT
TYPE ABSORBED WELL
BY PUMP
kW (4) (1) (2) (3) mm
L C U kg
Z10220 01/1C 14,6 442 258 2900 47,3 270
Z10220 01/1B 18,0 442 258 2900 47,3 270
Z10220 01/1A 21,5 442 258 2900 47,3 270
Z10220 01 24,0 442 258 2900 47,3 270
Z10220 02/2C 29,2 658 258 2900 66,6 270
Z10220 02/2B 36,0 658 258 2900 66,6 270
Z10220 02/2A 43,0 658 258 2900 66,9 270
Z10220 02 48,0 658 258 2900 66,9 270
Z10220 03/2B 60,0 874 258 2900 86,2 270
Z10220 03/2A 67,0 874 258 2900 86,2 270
Z10220 03 72,0 874 258 2900 86,2 270
Z10220 04/2B 84,0 1090 258 2900 105,5 270
Z10220 04/2A 91,0 1090 258 2900 105,5 270
Z10220 04 96,0 1090 258 2900 110,4 270
Z10220 05/2B 108,0 1306 258 2900 129,7 270
Z10220 05 120,0 1306 258 2900 129,7 270
Z10220 06/2B 132,0 1522 258 2900 149 270
Z10220 06 144,0 1522 258 2900 149 270
Z10220 07/2B 156,0 1738 271 2900 169,1 300
Z10220 07 168,0 1738 271 2900 169,1 300
Z10220 08/2B 180,0 1954 271 2900 188,4 300
Z10220 08 192,0 1954 271 2900 188,4 300
Z10220 09/2B 204,0 2170 271 2900 207,7 300
Z10220 09/1A 213,5 2170 271 2900 207,7 300
Z10220 10/2B 228,0 2386 271 2900 227 300
Z10220 10 240,0 2386 271 2900 227 300
Z10220 11/2B 252,0 2602 271 2900 246,3 300
Z10220 11 264,0 2602 271 2900 246,3 300
Z10220 12/2B 276,0 2818 271 2900 265,6 300
Z10220 12 288,0 2818 271 2900 265,6 300
MOTOR
DIMENSIONS (mm)
CONNECTION
N k d z b E H7 R l
6" (NEMA) 182 111,2 13,5 4 17 76,2 73 263
8" (NEMA) 182 152,4 18 4 17 127 101,45 263
10" 232 190,5 22 4 15 127 101,45 300
12" 232 190,5 22 4 15 127 126,85 300
DIMENSIONS (mm)
COUPLING Profile of gear coupling according to NEMA
NUMBER DIAMETRAL PRESSURE
OF TEETH PITCH ANGLE X
6" (NEMA) 15 16/32 30° 20
8" (NEMA) 23 16/32 30° 38
DIMENSIONS (mm)
COUPLING +0.084 +0.1 +0.05
F +0.059 H P +0.02 X
10" 42,85 47,6 9,5 84
12" 49.212 54,5 12,7 95
z10-mtcn-50-en_b_td
27
Z10275 PUMP SERIES
DIMENSIONI E PESI SERIE Z10275 A 50 Hz
DIMENSIONS AND WEIGHTS
MAX Ø
PUMP POWER DIMENSIONS (mm) MIN.
WEIGHT
TYPE ABSORBED WELL
BY PUMP
kW (4) (1) (2) (3) mm
L C U kg
Z10275 01/1B 17,3 442 258 2900 47,4 270
Z10275 01/1A 21,9 442 258 2900 47,4 270
Z10275 01 26,9 442 258 2900 47,4 270
Z10275 02/2B 34,6 658 258 2900 66,9 270
Z10275 02/2A 43,8 658 258 2900 67,2 270
Z10275 02 53,8 658 258 2900 67,2 270
Z10275 03/2B 61,5 874 258 2900 86,7 270
Z10275 03/3A 65,7 874 258 2900 86,7 270
Z10275 03/1A 75,7 874 258 2900 86,7 270
Z10275 03 80,7 874 258 2900 86,7 270
Z10275 04/3A 92,6 1090 258 2900 106,2 270
Z10275 04/2A 97,6 1090 258 2900 111,1 270
Z10275 04 107,6 1090 258 2900 111,1 270
Z10275 05/3A 119,5 1306 258 2900 130,6 270
Z10275 05 134,5 1306 258 2900 130,6 270
Z10275 06/3A 146,4 1522 258 2900 150,1 270
Z10275 06 161,4 1522 271 2900 150,1 300
Z10275 07/2A 178,3 1738 271 2900 170,4 300
Z10275 07 188,3 1738 271 2900 170,4 300
Z10275 08/2B 196,0 1954 271 2900 189,9 300
Z10275 08/1A 210,2 1954 271 2900 189,9 300
Z10275 09/3A 227,1 2170 271 2900 209,4 300
Z10275 09 242,1 2170 271 2900 209,4 300
Z10275 10/3A 254,0 2386 271 2900 228,9 300
Z10275 10 269,0 2386 271 2900 228,9 300
Z10275 11/1A 290,9 2602 271 2900 248,4 300
DIMENSIONI ACCOPPIAMENTO MOTORI SERIE Z10 z10275p-50-en_a_td
50 Hz
MOTOR COUPLING
MOTOR
DIMENSIONS (mm)
CONNECTION
N k d z b E H7 R l
6" (NEMA) 182 111,2 13,5 4 17 76,2 73 263
8" (NEMA) 182 152,4 18 4 17 127 101,45 263
10" 232 190,5 22 4 15 127 101,45 300
12" 232 190,5 22 4 15 127 126,85 300
DIMENSIONS (mm)
COUPLING Profile of gear coupling according to NEMA
NUMBER DIAMETRAL PRESSURE
OF TEETH PITCH ANGLE X
6" (NEMA) 15 16/32 30° 20
8" (NEMA) 23 16/32 30° 38
DIMENSIONS (mm)
COUPLING +0.084 +0.1 +0.05
F +0.059 H P +0.02 X
10" 42,85 47,6 9,5 84
12" 49.212 54,5 12,7 95
z10-mtcn-50-en_b_td
28
Z10 SERIES
PUMP CROS
CROSSS SECTION AND LIST OF COMPONENTS
DENOMINAZIONE COMPONENTI
SERIE Z10-2poli 50 Hz
REF. N. DESCRIPTION
1 Stage casing
2 Suction casing
3 Delivery casing
4 Valve body
5 Bearing bush
6 Impeller
7 Wear ring
8 Shaft
9 Coupling
10 Locking sleeve
11 Thrust bearing
12 Valve plate
13 Valve seat
14 Valve spring
15 Wing valve
16 Suction strainer
17 Cable
18 Cable protection
19 O-ring
20 Intermediate ring
z10-2p50-en_a_tp
29
30
12” MARKET SECTORS
Submersible AGRICULTURAL, INDUSTRIAL, MUNICIPAL.
Electric APPLICATIONS
APPLICATIONS
Pumps • Water supply from deep wells.
• Pressure boosting and water distribution in civil and
industrial systems.
Z12340 • Supply of surge tanks and reservoirs.
Z12420 • Firefighting and washing systems.
Series • Water table level control.
• Irrigation.
SPECIFICATIONS
SPECIFICATIONS • Maximum number of starts per hour:
PUMP 10 (L8W) 8 (L10W) 4 (L12W).
• Delivery
Delivery: up to 520 m3/h. • Maximum temperature of water in
• Head
Head: up to 450 m. contact with motor:
• Maximum pump overall diameter L8W, L10W and L12W 30°C.
(2 cable covers included): 302 mm. • Special versions
versions: AISI 316 and
• Maximum electric pump immersion Duplex materials, HT for applications
depth: 350 m with L8W, L10W in high temperature environments
and L12W motors. (up to 60°C) or under inverter.
• The content of sand should not exceed
50 g/m3, higher contents up to 100 g/m3 CONSTRUCTION
can be admitted, if wear is tolerated. FEATURES
FEATURES
• Horizontal installation possible (it is PUMP
recommended to have an incline of at • Robust but lightweight, easy to
least 3° with the motor on the lowest maintain and with high corrosion
position). resistance.
• Standard delivery outlet: • Impeller and diffusers made of
8” NPT according to API. stainless steel castings.
• Motor power: from 30 to 350 kW. • Delivery head and suction support of
• Electric pumps with powers up to stainless steel castings.
300 kW are supplied with Lowara • Stainless steel non return valve
motor series. For larger powers please integrated, spring equipped.
contact our sales network. • Stainless steel shaft.
• Guide bearings and wear rings ensure
MOTOR high reliability and long lasting
• L8W, L10W and L12W rewindable hydraulic performances.
water filled three-phase motors. • The new design ensures high efficiency
• Three-phase version
version: and low power consumption.
L8W: 30 to 93 kW 380-415 V, 50 Hz. • Special versions
versions: ZR12 made of
L10W: 93 to 150 kW 380-415 V, Duplex stainless steel.
50 Hz. • Coupling according to NEMA standard
L12W: 185 to 300 kW 380-415 V, for 8” motor, with key connection for
50 Hz. 10” and 12” motor.
• Maximum supply voltage variations:
L8W, L10W, L12W 400V ±10%. ACCES SORIES
ACCESSORIES
• Horizontal operation
operation: • Coupling flange.
L8W, L10W and L12W all versions are • Panels.
designed for horizontal installation, • Drop cables.
provided that the direction of the axial • Cooling shrouds.
thrust generated by the impellers is • Temperature sensor PT 100 / PTC
PTC.
always from the pump to the motor.
31
TTABELLA
ABLE OFMATERIALI
MA Z12
TERIALS
MATERIALS Z12
COMPONENT MATERIAL DESIGNATION
EUROPE USA
Delivery head / Valve Casing Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Valve Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Valve seat NBR 90
Valve spring Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
Diffuser / Bowl Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Diffuser O-Ring NBR 70
Impeller Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Taperlock Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
Wear ring POM
Lower support / Suction Casing Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Suction strainer Stainless steel DIN 17440-X6CrNiMoTi17-12-2 (1.4571) AISI 316Ti
Pump shaft Stainless steel EN 10088-1-X17CrNi16-2 (1.4057) AISI 431
Coupling Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
Bearing bush EPDM + LOXAMID ®
Thrust Bearing PTFE + 25% carbon
Screw, stud, nut Stainless steel ISO 3506-1/2 A4-70 AISI 316
Cable protection Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI 304
MOTOR CODE
REDUCTION TYPE
NUMBER OF REDUCED STAGES
NUMBER OF STAGES
FLOW RATE IN m3/h
TYPE OF PUMP (R = DUPLEX VERSION)
BLANK = 50 Hz
6 = 60 Hz
32
Z12 SERIES
HYDRA ULIC PERFORMANCE RANGE A
HYDRAULIC T 50 Hz
AT
33
Z12340 SERIES, 1 TO 2 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z12340 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 2000 3333 4667 5667 6667
TYPE POWER m3/h 0 120 200 280 340 400
z12340-2p50-1-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z12340-2p50-1-en_a_td
34
Z12340 SERIES, 1 TO 2 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
35
Z12340 SERIES, 3 TO 4 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z12340 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 2000 3333 4667 5667 6667
TYPE POWER m3/h 0 120 200 280 340 400
z12340-2p50-2-en_a_th
PUMP RATED
DIMENSIONS (mm WEIGHT
TYPE POWER
z12340-2p50-2-en_a_td
36
Z12340 SERIES, 3 TO 4 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
37
Z12340 SERIES, 5 TO 8 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z12340 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 2000 3333 4667 5667 6667
TYPE POWER m3/h 0 120 200 280 340 400
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
** For power above 350 kW please contact our sales network. z12340-2p50-3-en_a_td
38
Z12340 SERIES, 5 TO 8 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
39
Z12420 SERIES, 1 TO 2 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z12420 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 2500 4167 5833 7000 8667
TYPE POWER m3/h 0 150 250 350 420 520
z12420-2p50-1-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z10200-2p50-1-en_a_td
40
Z12420 SERIES, 1 TO 2 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
41
Z12420 SERIES, 3 TO 4 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z12420 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 2500 4167 5833 7000 8667
TYPE POWER m3/h 0 150 250 350 420 520
z12420-2p50-2-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
z12420-2p50-2-en_a_td
42
Z12420 SERIES, 3 TO 4 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
Z12420 ∼ 2900 [rpm] ISO 9906 - Annex A
0 250 500 750 1000 1250 1500 1750 2000 Q [Imp gpm]
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 Q [US gpm]
225
4 700
4/3A
200
H [m]
4/3B
600
175
H [ft]
3
150 3/3A 500
3/2B
3/2C
125 400
100
300
75
200
50
100
25
200 4
4/3A 240
175
PP [kW]
4/3B PP [HP]
150 200
3
3/3A
125
3/2B 160
100 3/2C
120
24 100
η
60
NPSH [m]
16 80
NPSH [ft]
η [%]
40
NPSH
8 60
20
0 40
03835_A_CH
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
43
Z12420 SERIES, 5 TO 7 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z12420 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP RATED l/min 0 2500 4167 5833 7000 8667
TYPE POWER m3/h 0 150 250 350 420 520
z12420-2p50-3-en_a_th
PUMP RATED
DIMENSIONS (mm) WEIGHT
TYPE POWER
D min = 320 mm
** For power above 350 kW please contact our sales network. z12420-2p50-3-en_a_td
44
Z12420 SERIES, 5 TO 7 STAGES
STAGES
OPERATING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
45
Z12340 PUMP SERIES
DIMENSIONI E PESI SERIE Z12340 A 50 Hz
DIMENSIONS AND WEIGHTS
MAX Ø
PUMP POWER DIMENSIONS (mm) MIN.
WEIGHT
TYPE ABSORBED WELL
BY PUMP
kW (4) (1) (2) (3) mm
L C U kg
Z12340 01/1B 29,2 510 290 2900 72 305
Z12340 01/1A 34,9 510 290 2900 72 305
Z12340 01 42,6 510 290 2900 72 305
Z12340 02/2C 50,5 745 290 2900 99,3 305
Z12340 02/2B 57,2 745 290 2900 99,3 305
Z12340 02/2A 70,5 745 290 2900 99,3 305
Z12340 02 84,2 745 290 2900 99,3 305
Z12340 03/2C 94,6 980 302 2900 129,4 315
Z12340 03/3A 109,1 980 302 2900 129,4 315
Z12340 03/1A 124,5 980 302 2900 129,4 315
Z12340 03 132,4 980 302 2900 129,4 315
Z12340 04/2B 147,4 1215 302 2900 156,7 315
Z12340 04/2A 159,6 1215 302 2900 157,5 320
Z12340 04 173,8 1215 302 2900 157,5 320
Z12340 05/2B 193,3 1450 302 2900 184,8 320
Z12340 05/2A 205,2 1450 302 2900 184,8 320
Z12340 05 219,5 1450 302 2900 184,8 320
Z12340 06/2B 235,2 1685 302 2900 212,1 320
Z12340 06/2A 246,5 1685 302 2900 212,1 320
Z12340 06 260,7 1685 302 2900 212,1 320
Z12340 07/3A 280,0 1920 302 2900 239,4 320
Z12340 07 301,0 1920 302 2900 239,4 320
Z12340 08/3A 333,1 2155 302 2900 266,7 320
Z12340 08 354,8 2155 302 2900 266,7 320
DIMENSIONI ACCOPPIAMENTO MOTORI SERIE Z12 50 Hz
MOTOR COUPLING
z12340p-50-en_a_td
MOTOR
DIMENSIONS (mm))
CONNECTION
N k d z b E H7 R l
8" (NEMA) 185 152,4 M16 4 20 127 101,45 240
10" 232 190,5 M20 4 22 127 101,45 300
12" 232 190,5 M20 4 23 127 126,85 300
DIMENSIONS (mm)
COUPLING Profile of gear coupling according to NEMA
NUMBER DIAMETRAL PRESSURE
OF TEETH PITCH ANGLE X
8" (NEMA) 23 16/32 30° 38
DIMENSIONS (mm)
COUPLING
F H P X
h6
10" 42.85 47,6 9,5 86
12" 49.212h6 54,5 12,7 95
z12-mtcn-50-en_a_td
46
Z12420 PUMP SERIES
DIMENSIONI E PESI SERIE Z12420 A 50 Hz
DIMENSIONS AND WEIGHTS
MAX Ø
PUMP POWER DIMENSIONS (mm) MIN.
WEIGHT
TYPE ABSORBED WELL
BY PUMP
kW (4) (1) (2) (3) mm
L C U kg
Z12420 01/1C 29,7 510 290 2900 72 305
Z12420 01/1B 35,4 510 290 2900 72 305
Z12420 01/1A 43,1 510 290 2900 72 305
Z12420 01 47,0 510 290 2900 72 305
Z12420 02/2C 58,2 745 290 2900 99,3 305
Z12420 02/2B 71,5 745 290 2900 99,3 305
Z12420 02/2A 86,2 745 290 2900 99,3 305
Z12420 02 98,5 745 302 2900 102,1 315
Z12420 03/2C 109,6 980 302 2900 129,4 315
Z12420 03/2B 122,8 980 302 2900 129,4 315
Z12420 03/3A 134,1 980 302 2900 129,4 315
Z12420 03 147,8 980 302 2900 129,4 315
Z12420 04/3B 161,3 1215 302 2900 157,5 320
Z12420 04/3A 184,3 1215 302 2900 157,5 320
Z12420 04 200,1 1215 302 2900 157,5 320
Z12420 05/2B 223,1 1450 302 2900 184,8 320
Z12420 05 247,6 1450 302 2900 184,8 320
Z12420 06/2B 269,8 1685 302 2900 212,1 320
Z12420 06 291,0 1685 302 2900 212,1 320
Z12420 07/2B 325,4 1920 302 2900 239,4 320
Z12420 07 350,2 1920 302 2900 239,4 320
z12420p-50-en_a_td
N k d z b E H7 R l
8" (NEMA) 185 152,4 M16 4 20 127 101,45 240
10" 232 190,5 M20 4 22 127 101,45 300
12" 232 190,5 M20 4 23 127 126,85 300
DIMENSIONS (mm)
COUPLING Profile of gear coupling according to NEMA
NUMBER DIAMETRAL PRESSURE
OF TEETH PITCH ANGLE X
8" (NEMA) 23 16/32 30° 38
DIMENSIONS (mm)
COUPLING
F H P X
h6
10" 42.85 47,6 9,5 86
12" 49.212h6 54,5 12,7 95
z12-mtcn-50-en_a_td
47
Z12 SERIES
PUMP CROS
CROSSS SECTION AND LIST OF COMPONENTS
DENOMINAZIONE COMPONENTI
SERIE Z12-2poli 50 Hz
REF. N. DESCRIPTION
1 Stage casing
2 Suction casing
3 Delivery casing
4 Valve body
5 Bearing bush
6 Impeller
7 Wear ring
8 Shaft
9 Coupling
10 Locking sleeve
11 Thrust bearing
12 Valve plate
13 Valve seat
14 Valve spring
15 Wing valve
16 Suction strainer
17 Cable
18 Cable protection
19 O-ring
20 Intermediate ring
z12-2p50-en_a_tp
48
6” Water filled submersible motors.
Submersible The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
motors
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.
L6W
Series
SPECIFICATIONS
SPECIFICATIONS SPECIAL VERSIONS
• Stainless steel outer sleeve. • Motors with double cable outlet for
• Shaft extension and coupling star/delta start.
dimensions to NEMA standards. • L6WN series
series: complete range
• Rewindable stator stator. available realized of AISI 316
• Class Y insulation
insulation. stainless steel.
• Protection class: IP68
IP68. • L6WR series
series: complete range
• Compensating bellows for internal available realized of Duplex
liquid expansion. stainless steel.
• Axial load supported by Kingsbury • HT series
series: complete range
type thrust bearing. available for all the L6W/N/R
• Mechanical seal construction, realized for applications
protected by sand guard. in high temperature environments
• Maximum immersion depth depth: up to 60°C
(up 60°C) or under inverter.
350 m.
• Maximum number of starts per OPTIONAL FEATURES
FEATURES
hour at regular intervals: 15. • Silicon Carbide mechanical seal.
• Maximum supply voltage • Special voltages.
variations allowed : ±10%.
• Maximum water temperature
temperature: ACCES SORIES
ACCESSORIES
30°C. • Temperature sensor PT 100 / PTC
PTC.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket as following:
Standard versions 0,2 m/s (4÷9,3 kW),
0,3 m/s (11÷30 kW) and
0,5 m/s (37 kW).
HT versions 0,2 m/s (5,5÷7,5 kW),
0,3 m/s (9,3÷26 kW) and
0,5 m/s (30 kW).
• Axial thrust
thrust:
16000 N from 4 to 22 kW;
30000 N from 26 to 37 kW.
• Power supply cable suitable
for drinkable water.
Rewindable
• Versions
ersions:
stator - Three-phase:
4 to 37 kW 380-415 V, 50 Hz.
Thrust bearing • Horizontal operation
operation:
valid for all versions provided that the
Kingsbury direction of the axial thrust generated
type by the impellers is always from the
pump to the motor.
• Flat power supply cable.
Mechanical • Screws included.
seal
49
L6W - L6WN - L6WR MOTOR SERIES
MOTOR CROS S SECTION
CROSS
50
MOTORI SERIE L6W: TABELLA MATERIALI
L6W TABLE OF MA
TABLE TERIALS
MATERIALS
REF. PART MATERIAL DESIGNATION
N° EUROPE USA
1
Upper bracket Cast iron EN-GJL-200 Class 25 B
2
Spacer Cast iron EN-GJL-200 Class 25 B
3
Filling plug + OR Stainless steel+NBR EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
4
Vent valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
5
Cable EPR
Cable gland plate
6 Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
Cable gland
7 EPDM
8
Shaft end Stainless steel EN 10088-1-X20Cr13 (1.4021) AISI420
9
Removable sand guard EPDM
10
Mechanical seal cover Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) ASTM CF-8 (AISI 304 cast)
11
Mechanical seal Carbon graphite / Aluminium oxide
12
Bush bearings Carbon graphite
13
Elastomers NBR
14
Motor sleeve Stainless steel EN 10088-1-X2CrNi19-11 (1.4306) AISI304L
15
Lower bracket Cast iron EN-GJL-200 Class 25 B
Thrust bearing bracket
16 Cast iron EN-GJL-200 Class 25 B
17
Diaphragm EPDM
18
Lower cover Cast iron EN-GJL-200 Class 25 B
19
Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
MOTORI SERIE L6WN:
Cooling liquid TABELLA MATERIALI
Water + antifreeze
L6WN TABLE OF MA
TABLE TERIALS
MATERIALS L6w-2p50-en_b_tm
51
L6W MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L6W 110 T 40 5 /_ HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L6W (CAST IRON STANDARD VERSION)
L6WN (AISI 316 VERSION)
L6WR (DUPLEX VERSION)
EXAMPLE : L6W110T405/A HT
L6W MOTOR :
RATED POWER 11 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz; /A VERSION; HIGH TEMPERATURE
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type 7 - Weight
2 - Code 8 - Maximum immersion depht
3 - Maximum water temperature 9 - Operating characteristics
4 - Minimum water velocity 10 - Production date
5 - Insulation class 11 - Serial number
6 - Protection class 12 - Characteristics at service factor
52
L6W MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
53
L6W MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
THREE-PHASE CURRENT Sec. (mm2)
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 9,89 2835 68,1 0,9 1,00 3,56
L6W40T405 4 5,5 400 9,26 2865 71,0 0,88 1,13 4,00 30 4 - 4
415 9,13 2880 71,5 0,85 1,21 4,20
380 12,7 2855 75,4 0,88 1,18 4,37
L6W55T405 5,5 7,5 400 12,4 2875 75,7 0,85 1,31 4,70 30 4 4 4
415 12,5 2885 75,4 0,82 1,42 4,85
380 17,0 2840 74,9 0,9 1,26 4,34
L6W75T405 7,5 10 400 16,4 2860 76,0 0,87 1,41 4,74 30 4 4 4
415 16,2 2875 76,5 0,84 1,52 4,96
380 20,5 2840 77,6 0,89 1,51 4,64
L6W93T405 9,3 12,5 400 20,0 2860 78,2 0,86 1,68 5,01 30 4 4 4
415 19,9 2870 78,3 0,83 1,81 5,21
380 24,2 2830 77,2 0,9 1,44 4,38
L6W110T405 11 15 400 23,5 2850 78,0 0,87 1,47 4,75 30 4 4 4
415 23,4 2865 78,0 0,84 1,73 4,94
380 28,1 2830 77,9 0,9 1,31 4,53
L6W130T405 13 17,5 400 27,1 2855 78,9 0,88 1,47 4,93 30 4 4 4
415 27,0 2865 79,1 0,9 1,59 5,15
380 32,1 2830 80,2 0,88 1,55 4,88
L6W150T405 15 20 400 31,5 2855 80,6 0,85 1,72 5,25 30 4 4 4
415 31,3 2865 80,9 0,82 1,86 5,46
380 38,5 2845 81,8 0,89 1,77 5,23
L6W185T405 18,5 25 400 37,6 2860 82,4 0,86 1,97 5,65 30 6 4 4
415 37,5 2870 82,4 0,83 2,13 5,86
380 47,3 2865 81,7 0,87 0,86 4,60
L6W220T405 22 30 400 46,5 2880 82,2 0,83 0,96 4,93 30 6 4 4
415 46,7 2890 82,2 0,8 1,04 5,09
380 56,5 2860 81,9 0,85 1,58 4,82
L6W260T405 26 35 400 55,4 2880 82,7 0,82 1,76 5,18 30 6 4 4
415 55,7 2890 82,7 0,79 1,90 5,35
380 63,8 2870 82,3 0,87 1,07 4,94
L6W300T405 30 40 400 62,3 2890 83,1 0,84 1,19 5,32 30 10 4 4
415 62,0 2900 83,3 0,81 1,29 5,55
380 81,8 2845 79,6 0,86 1,03 4,25
L6W370T405 37 50 400 79,1 2870 81,2 0,83 1,15 4,63 30 10 4 4
415 79,4 2880 80,8 0,80 1,25 4,79
* Ts/Tn = ratio between starting torque and nominal torque. l6w-2p50-en_f_te
54
L6W HT MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
THREE-PHASE CURRENT Sec. (mm2)
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 9,81 2905 76,9 0,81 1,65 5,65
L6W40T405 HT 4 5,5 400 10,1 2915 75,5 0,76 1,83 5,78 45 4 4 4
415 10,5 2920 74,2 0,72 1,98 5,77
380 12,9 2895 77,1 0,84 1,75 5,71
L6W55T405 HT 5,5 7,5 400 13,0 2905 77,0 0,79 1..95 5,96 45 4 4 4
415 13,4 2915 76,3 0,75 2,10 6,03
380 16,9 2880 79,2 0,85 1,89 5,64
L6W75T405 HT 7,5 10 400 16,9 2890 79,0 0,81 2,11 5,91 45 4 4 4
415 17,3 2900 78,3 0,77 2,27 6,00
380 20,6 2865 79,2 0,87 1,72 5,13
L6W93T405 HT 9,3 12,5 400 20,4 2880 79,3 0,83 1,82 5,44 45 4 4 4
415 20,8 2890 78,4 0,79 2,07 5,53
380 23,8 2870 80,1 0,88 1,57 5,35
L6W110T405 HT 11 15 400 23,6 2885 80,1 0,84 1,75 5,69 45 4 4 4
415 23,9 2890 79,8 0,80 1,89 5,83
380 28,3 2860 81,8 0,85 1,80 5,55
L6W130T405 HT 13 17,5 400 28,1 2875 81,4 0,82 2,01 5,87 45 4 4 4
415 28,4 2885 81,4 0,78 2,17 6,03
380 31,8 2880 83,6 0,86 2,21 6,33
L6W150T405 HT 15 20 400 31,9 2890 83,4 0,82 2,46 6,65 45 6 4 4
415 32,5 2900 82,8 0,78 2,65 6,77
380 40,3 2895 83,9 0,83 1,04 5,40
L6W185T405 HT 18,5 25 400 40,5 2905 83,5 0,79 1,15 5,65 45 6 4 4
415 41,6 2910 83,0 0,75 1,24 5,71
380 48,5 2890 83,6 0,82 1,89 5,62
L6W220T405 HT 22 30 400 48,6 2905 83,6 0,78 2,10 5,90 45 6 4 4
415 49,7 2910 83,2 0,74 2,26 5,99
380 55,7 2895 83,8 0,85 1,24 5,66
L6W260T405 HT 26 35 400 55,2 2905 84,0 0,81 1,38 6,00 45 10 4 4
415 55,8 2915 83,9 0,77 1,49 6,17
380 67,1 2885 82,2 0,83 1,29 5,18
L6W300T405 HT 30 40 400 67,1 2900 82,8 0,78 1,44 5,46 45 10 4 4
415 68,8 2910 81,8 0,74 1,55 5,52
* Ts/Tn = ratio between starting torque and nominal torque. l6w-ht-2p50-en_c_te
55
56
8” Water filled submersible motors.
Submersible The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
motors
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.
L8W
Series
SPECIFICATIONS
SPECIFICATIONS SPECIAL VERSIONS
• Stainless steel outer sleeve. • Motors with double cable outlet for
• Shaft extension and coupling star/delta start.
dimensions to NEMA standards. • L8WN series
series: complete range
• Rewindable stator stator. available realized of AISI 316
• Class Y insulation
insulation. stainless steel.
• Protection class: IP68
IP68. • L8WR series
series: complete range
• Compensating bellows for internal available realized of Duplex
liquid expansion. stainless steel.
• Axial load supported by Kingsbury • HT series
series: complete range
type thrust bearing. available for all the L8W/N/R
• Mechanical seal construction, realized for applications
protected by sand guard. in high temperature environments
• Maximum immersion depth depth: up to 60°C
(up 60°C) or under inverter.
350 m.
• Maximum number of starts per OPTIONAL FEATURES
FEATURES
hour at regular intervals: 10. • Silicon Carbide mechanical seal.
• Maximum supply voltage • Special voltages.
variations allowed : ±10%.
• Maximum water temperature
temperature: ACCES SORIES
ACCESSORIES
30°C. • Temperature sensor PT 100 / PTC
PTC.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
• Axial thrust
thrust:
50000 N from 30 to 93 kW.
• Power supply cable suitable
for drinkable water.
• Versions
ersions:
- Three-phase:
30 to 93 kW 380-415 V, 50 Hz.
• Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
Rewindable
pump to the motor.
stator
Thrust bearing
Kingsbury
type
Mechanical
seal
57
L8W - L8WN - L8WR MOTOR SERIES
MOTOR CROS S SECTION
CROSS
58
L8W MOTOR SERIES: TABLE OF MATERIALS
L8W T ABLE OF MA
TABLE TERIALS
MATERIALS
REF. PART MATERIAL DESIGNATION
N° EUROPE USA
1Upper bracket Cast iron EN-GJL-200 Class 25 B
2Spacer Cast iron EN-GJL-200 Class 25 B
3Filling plug + OR Stainless steel+NBR EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
4Vent valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
5Cable EPR
6Cable gland plate Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
7Cable gland EPDM
8Shaft end Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
9Removable sand guard Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
10Mechanical seal cover Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
11Mechanical seal Carbon graphite / Aluminium oxide
12Bush bearings Carbon graphite
13Elastomers NBR
14Motor sleeve Stainless steel EN 10088-1-X2CrNi19-11 (1.4306) AISI304L
15Lower bracket Cast iron EN-GJL-200 Class 25 B
16Thrust bearing bracket Cast iron EN-GJL-200 Class 25 B
17Filling valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
18Diaphragm EPDM
19Lower cover Cast iron EN-GJL-200 Class 25 B
20Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
L8WN
CoolingMOTOR
liquid SERIES:
WaterTABLE OF MATERIALS
+ antifreeze
L8WN TABLE OF MA
TABLE TERIALS
MATERIALS L8w-2p50-en_a_tm
59
L8W MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L8W 550 T 40 5 /_ HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L8W (CAST IRON STANDARD VERSION)
L8WN (AISI 316 VERSION)
L8WR (DUPLEX VERSION)
EXAMPLE : L8W550T405/A HT
L8W MOTOR :
RATED POWER 55 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz; /A VERSION; HIGH TEMPERATURE
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type 7 - Weight
2 - Code 8 - Maximum immersion depht
3 - Maximum water temperature 9 - Operating characteristics
4 - Minimum water velocity 10 - Production date
5 - Insulation class 11 - Serial number
6 - Protection class 12 - Characteristics at service factor
60
L8W MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
61
L8W MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
2
THREE-PHASE CURRENT Sec. (mm )
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 65,0 2905 83,0 0,85 1,20 4,67
L8W300T405 30 40 400 62,0 2900 83,0 0,84 1,15 4,69 30 10 6 5,5
415 59,0 2900 83,0 0,84 1,09 4,70
380 81,0 2840 80,5 0,87 1,04 4,19
L8W370T405 37 50 400 78,5 2860 81,0 0,84 1,14 4,54 30 10 6 5,5
415 76,0 2870 81,5 0,83 1,23 4,88
380 92,0 2850 82,0 0,87 0,92 3,72
L8W450T405 45 60 400 89,0 2870 82,0 0,85 1,01 3,98 30 16 6 5,5
415 89,0 2880 83,5 0,83 1,09 4,23
380 110 2840 82,0 0,86 1,14 3,90
L8W520T405 52 70 400 108 2865 82,0 0,85 1,15 4,20 30 16 6 5,5
415 104 2885 82,5 0,82 1,16 4,50
380 118 2840 82,0 0,87 1,26 3,57
L8W550T405 55 75 400 114 2870 82,0 0,85 1,27 3,88 30 16 10 5,5
415 110 2885 82,5 0,83 1,27 4,19
380 124 2855 82,0 0,87 1,12 4,18
L8W600T405 60 80 400 120 2875 82,5 0,85 1,23 4,49 30 16 10 5,5
415 118 2885 83,5 0,83 1,33 4,80
380 138 2850 82,5 0,88 0,98 4,22
L8W670T405 67 90 400 133 2870 83,0 0,86 1,07 4,52 30 25 10 5,5
415 132 2885 83,5 0,83 1,16 4,82
380 156 2860 82,0 0,87 0,92 4,10
L8W750T405 75 100 400 152 2875 82,5 0,85 1,01 4,41 30 25 16 5,5
415 148 2885 83,0 0,82 1,10 4,72
380 172 2860 83,0 0,87 0,91 4,12
L8W830T405 83 110 400 168 2870 83,5 0,84 1,00 4,39 30 35 16 5,5
415 163 2880 84,0 0,82 1,08 4,66
380 192 2850 83,0 0,87 0,84 3,38
L8W930T405 93 125 400 186 2860 83,5 0,85 0,92 3,84 30 35 16 5,5
415 180 2885 84,0 0,83 1,00 4,30
* Ts/Tn = ratio between starting torque and nominal torque. l8w-2p50-en_d_te
62
L8W HT MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO L8W HT A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICS S AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
2
THREE-PHASE CURRENT Sec. (mm )
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 66,6 2865 82,5 0,84 1,29 5,10
L8W300T405 HT 30 40 400 64,5 2885 83,0 0,81 1,41 5,52 45 10 6 5,5
415 62,4 2895 83,5 0,8 1,53 5,94
380 77,5 2865 84,0 0,86 1,12 4,41
L8W370T405 HT 37 50 400 75,0 2885 84,0 0,84 1,23 4,72 45 16 6 5,5
415 75,0 2895 85,5 0,82 1,33 5,02
380 97,8 2860 83,0 0,83 1,33 4,39
L8W450T405 HT 45 60 400 96,0 2885 83,0 0,82 1,34 4,73 45 16 6 5,5
415 92,4 2905 83,5 0,79 1,35 5,06
380 110 2835 83,0 0,86 1,33 3,84
L8W520T405 HT 52 70 400 106 2865 83,0 0,84 1,34 4,17 45 16 10 5,5
415 102 2880 83,5 0,82 1,34 4,51
380 117 2865 83,5 0,86 1,23 4,44
L8W550T405 HT 55 75 400 113 2885 84,0 0,84 1,34 4,77 45 16 10 5,5
415 111 2895 85,0 0,82 1,46 5,10
380 127 2860 83,5 0,87 1,10 4,60
L8W600T405 HT 60 80 400 122 2880 84,0 0,85 1,20 4,93 45 25 10 5,5
415 121 2895 84,5 0,82 1,30 5,25
380 141 2870 82,5 0,85 1,03 4,55
L8W670T405 HT 67 90 400 137 2885 83,0 0,83 1,13 4,89 45 25 16 5,5
415 133 2895 83,5 0,8 1,24 5,24
380 156 2905 82,5 0,86 1,02 4,55
L8W750T405 HT 75 100 400 152 2915 83,0 0,83 1,12 4,85 45 35 16 5,5
415 147 2925 83,5 0,81 1,21 5,15
380 171 2875 84,5 0,86 0,95 3,79
L8W830T405 HT 83 110 400 166 2885 85,0 0,84 1,04 4,30 45 35 16 5,5
415 161 2910 85,5 0,82 1,13 4,82
* Ts/Tn = ratio between starting torque and nominal torque. l8w-ht-2p50-en_a_te
63
64
10” Water filled submersible motors.
Submersible The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
motors
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.
L10W
Series
SPECIFICATIONS
SPECIFICATIONS SPECIAL VERSIONS
• Stainless steel outer sleeve. • Motors with double cable outlet for
• Rewindable stator stator. star/delta start.
• Class Y insulation
insulation. • L10WN series
series: complete range
• Protection class: IP68
IP68. available realized of AISI 316
• Compensating bellows for internal stainless steel.
liquid expansion. • L10WR series
series: complete range
• Axial load supported by Kingsbury available realized of Duplex
type thrust bearing. stainless steel.
• Mechanical seal • HT series
series: complete range
protected by sand guard. available for all the L10W/N/R
• Maximum immersion depth depth: construction, realized for applications
350 m. in high temperature environments
• Maximum number of starts per up to 60°C
(up 60°C) or under inverter.
hour at regular intervals: 8.
• Maximum supply voltage
OPTIONAL FEATURES
FEATURES
variations allowed : ±10%.
• Silicon Carbide mechanical seal.
• Maximum water temperature
temperature:
• Special voltages.
30°C.
Max. temperature applies to motors
ACCES SORIES
ACCESSORIES
working in a installation capable of
• Temperature sensor PT 100 / PTC
PTC.
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
• Axial thrust
thrust:
65000 N from 93 to150 kW.
• Power supply cable suitable
for drinkable water.
• Versions
ersions:
- Three-phase:
93 to 150 kW 380-415 V, 50 Hz.
• Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
pump to the motor.
Rewindable
stator
Thrust bearing
Kingsbury
type
Mechanical
seal
65
L10W - L10WN - L10WR MOTOR SERIES
MOTOR CROS S SECTION
CROSS
66
L10W MOTOR SERIES: TABLE OF MATERIALS
L10W T ABLE OF MA
TABLE TERIALS
MATERIALS
REF. PART MATERIAL DESIGNATION
N° EUROPE USA
1 Upper bracket Cast iron EN-GJL-200 Class 25 B
2 Spacer Cast iron EN-GJL-200 Class 25 B
3 Filling plug + OR Stainless steel+NBR EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
4 Vent valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
5 Cable EPR
6 Cable gland plate Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
7 Cable gland EPDM
8 Shaft end Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
9 Removable sand guard Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
10 Mechanical seal cover Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
11 Mechanical seal Carbon graphite / Aluminium oxide
12 Bush bearings Carbon graphite
13 Elastomers NBR
14 Motor sleeve Stainless steel EN 10088-1-X2CrNi19-11 (1.4306) AISI304L
15 Lower bracket Cast iron EN-GJL-200 Class 25 B
16 Thrust bearing bracket Cast iron EN-GJL-200 Class 25 B
17 Filling valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
18 Diaphragm EPDM
19 Lower cover Cast iron EN-GJL-200 Class 25 B
20 Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
L10WN
CoolingMOTOR
liquid SERIES:
Water + TABLE
antifreezeOF MATERIALS
L10WN TABLE OF MA
TABLE TERIALS
MATERIALS L10w-2p50-en_a_tm
67
L10W MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L10W 1500 T 40 5 /_ HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L10W (CAST IRON STANDARD VERSION)
L10WN (AISI 316 VERSION)
L10WR (DUPLEX VERSION)
EXAMPLE : L10W1500T405/A HT
L10W MOTOR :
RATED POWER 150 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz; /A VERSION; HIGH TEMPERATURE
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type 7 - Weight
2 - Code 8 - Maximum immersion depht
3 - Maximum water temperature 9 - Operating characteristics
4 - Minimum water velocity 10 - Production date
5 - Insulation class 11 - Serial number
6 - Protection class 12 - Characteristics at service factor
68
L10W MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
69
L10W MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
2
THREE-PHASE CURRENT Sec. (mm )
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 191 2895 83,0 0,87 1,02 5,14
L10W930T405 93 125 400 184 2910 83,0 0,85 1,12 5,55 30 35 25 5
415 180 2915 84,0 0,84 1,21 5,95
380 235 2900 83,5 0,86 1,20 4,77
L10W1100T405 110 150 400 225 2910 83,5 0,84 1,32 5,17 30 50 25 5
415 220 2920 84,5 0,82 1,43 5,57
380 270 2895 84,0 0,86 1,29 4,84
L10W1300T405 130 175 400 263 2915 83,0 0,85 1,42 5,22 30 50 25 5
415 255 2915 85,5 0,83 1,54 5,60
380 308 2905 83,0 0,86 1,26 4,77
L10W1500T405 150 200 400 295 2915 83,0 0,85 1,38 5,20 30 70 25 5
415 285 2925 84,0 0,84 1,50 5,63
* Ts/Tn = ratio between starting torque and nominal torque. l10w-2p50-en_b_te
70
12” Water filled submersible motors.
Submersible The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
motors
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.
L12W
Series
SPECIFICATIONS
SPECIFICATIONS SPECIAL VERSIONS
• Stainless steel outer sleeve. • Motors with double cable outlet for
• Rewindable stator stator. star/delta start.
• Class Y insulation
insulation. • L12WN series
series: complete range
• Protection class: IP68
IP68. available realized of AISI 316
• Compensating bellows for internal stainless steel.
liquid expansion. • L12WR series
series: complete range
• Axial load supported by Kingsbury available realized of Duplex
type thrust bearing. stainless steel.
• Mechanical seal • HT series
series: complete range
protected by sand guard. available for all the L12W/N/R
• Maximum immersion depth depth: construction, realized for applications
350 m. in high temperature environments
• Maximum number of starts per up to 60°C
(up 60°C) or under inverter.
hour at regular intervals: 4.
• Maximum supply voltage OPTIONAL FEATURES
FEATURES
variations allowed : ±10%. • Silicon Carbide mechanical seal.
• Maximum water temperature
temperature: • Special voltages.
30°C.
Max. temperature applies to motors ACCES SORIES
ACCESSORIES
working in a installation capable of • Temperature sensor PT 100 / PTC
PTC.
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
• Axial thrust
thrust:
65000 N from 185 to 300 kW.
• Power supply cable suitable
for drinkable water.
• Versions
ersions:
- Three-phase:
185 to 300 kW 380-415 V, 50 Hz.
• Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
pump to the motor.
Rewindable
stator
Thrust bearing
Kingsbury
type
Mechanical
seal
71
L12W - L12WN - L12WR MOTOR SERIES
MOTOR CROS S SECTION
CROSS
72
L12W MOTOR SERIES: TABLE OF MATERIALS
L12W T ABLE OF MA
TABLE TERIALS
MATERIALS
REF. PART MATERIAL DESIGNATION
N° EUROPE USA
1 Upper bracket Cast iron EN-GJL-200 Class 25 B
2 Filling plug + OR Stainless steel+NBR EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
3 Vent valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
4 Cable EPR
5 Cable gland plate Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
6 Cable gland EPDM
7 Shaft end Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
8 Removable sand guard Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
9 Mechanical seal cover Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
10 Mechanical seal Carbon graphite / Aluminium oxide
11 Bush bearings Carbon graphite
12 Elastomers NBR
13 Stator flanges Steel UNI 3158 - Fe 52
14 Motor sleeve Stainless steel EN 10088-1-X2CrNi19-11 (1.4306) AISI304L
15 Lower bracket Cast iron EN-GJL-200 Class 25 B
16 Thrust bearing bracket Cast iron EN-GJL-200 Class 25 B
17 Filling valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
18 Diaphragm EPDM
19 Lower cover Cast iron EN-GJL-200 Class 25 B
20 Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
L12WN MOTOR SERIES: TABLE OF MATERIALS
Cooling liquid Water + antifreeze
L12WN T ABLE OF MA
TABLE TERIALS
MATERIALS
L12w-2p50-en_a_tm
73
L12W MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L12W 3000 T 40 5 /_ HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L12W (CAST IRON STANDARD VERSION)
L12WN (AISI 316 VERSION)
L12WR (DUPLEX VERSION)
EXAMPLE : L12W3000T405/A HT
L12W MOTOR :
RATED POWER 300 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz; /A VERSION; HIGH TEMPERATURE
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type 7 - Weight
2 - Code 8 - Maximum immersion depht
3 - Maximum water temperature 9 - Operating characteristics
4 - Minimum water velocity 10 - Production date
5 - Insulation class 11 - Serial number
6 - Protection class 12 - Characteristics at service factor
74
L12W MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
75
L12W MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
2
THREE-PHASE CURRENT Sec. (mm )
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 380 2895 84,0 0,87 1,28 5,57
L12W1850T405 185 250 400 370 2905 84,0 0,86 1,41 5,99 30 70 50 5
415 360 2915 84,5 0,86 1,53 6,40
380 470 2910 84,5 0,86 1,04 4,60
L12W2200T405 220 300 400 456 2925 84,5 0,85 1,14 5,01 30 95 50 5
415 435 2930 85,5 0,83 1,24 5,42
380 525 2875 85,0 0,87 0,96 4,10
L12W2600T405 260 350 400 512 2890 85,0 0,85 1,06 4,39 30 120 70 5
415 498 2910 86,0 0,83 1,15 4,67
380 620 2880 85,0 0,87 0,90 4,10
L12W3000T405 300 400 400 594 2900 85,0 0,85 0,99 4,50 30 2x70 70 5
415 570 2910 86,0 0,84 1,08 4,90
* Ts/Tn = ratio between starting torque and nominal torque. l12w-2p50-en_c_te
76
ACCES SORIES
ACCESSORIES
77
ISO THREADED FLANGES
Dimensions (mm)
PUMP THREADING
Flange according to EN 1092-1
TYPE G
DN PN ØD Ød Øk b Ø d2 Z L L1
150 10 ÷ 16 285 212 240 22 22 8 198 40
150 25 ÷ 40 300 218 250 28 26 8 218 40
150 63 345 218 280 36 33 8 238 40
Z10150
EN 10226-1 200 10 340 268 295 24 22 8 357 40
Z10220
R6 200 16 340 268 295 24 22 12 357 40
Z10275
200 25 360 278 310 30 26 12 375 40
200 40 375 285 320 34 30 12 383 40
200 63 415 285 345 42 36 12 405 40
200 10 340 - 295 26 22 8 150 55
200 16 340 - 295 30 22 12 150 55
ANSI B1.20.1
Z12340 200 25 360 - 310 34 26 12 150 55
API 8 NPT
200 40 375 - 320 40 30 12 150 55
200 63 415 - 345 42 36 12 150 55
Material : Stainless steel EN 10088-1 - X6CrNiMoTi17-12-2 (1.4571) AISI 316Ti. (Other materials available on request). z-flange-r-en_b_td
78
ANSI (API) THREADED FLANGE
Dimensions (mm)
PUMP THREADING
Flange according to ASME B16.5
TYPE EN 10226-1
G DN Class ØD Ød Øk b Ø d2 Z L L1
6" 150 280 216 241 25 22 8 232 40
6" 300 317 216 270 37 22 12 242 40
Z10150
6" 600 356 216 292 54 29 12 266 40
Z10220 R6
8" 150 343 270 298 28 22 8 397 40
Z10275
8" 300 381 270 330 41 25 12 406 40
8" 600 419 270 349 62 32 12 434 40
Material : Stainless steel EN 10088-1 - X6CrNiMoTi17-12-2 (1.4571) AISI 316Ti. (Other materials available on request). z-flange-api-en_b_td
79
CARRYING CLAMPS
NOTE. Two sets of clamps are necessary for the installation of one unit.
Material : EN 10027-1-S235JR (1.0038) painted.
80
L6W - L8W MOTOR SERIES
TABELLE INDICATIVE DI ABBINAMENTO MOTORE - QUADRO
MOTOR - CONTROL P ANEL COMBINA
PANEL TION T
COMBINATION ABLE
TABLE
MOTOR TYPE RATED RATED PANEL TYPE
L6W - 6" POWER CURRENT
THREE-PHASE 380-415 V
kW HP A QTD/… Q3D/… Q3I/… Q3A/… Q3Y/… Q3SF/…
4 5,5 9,89 …40-75 …40-75 …40-75 …40-75 …40-75 …75
5,5 7,5 12,7 …40-75 …40-75 …40-75 …40-75 …40-75 …75
7,5 10 17,0 …75-92 …75-92 …75-92 …75-92 …75-92 …150
9,3 12,5 20,5 - …92-110 …92-110 …92-110 …92-110 …150
11 15 24,2 - …110-150 …110-150 …110-150 …110-150 …150
13 17,5 28,1 - …110-150 …110-150 …110-150 …110-150 …150
15 20 32,1 - …150-185 …150-185 …150-185 …150-185 …220
18,5 25 38,5 - …185-220 …185-220 …185-220 …185-220 …220
22 30 47,3 - …220-300 …220-300 …220-300 …220-300 …300
26 35 56,5 - …220-300 …220-300 …220-300 …220-300 …300
30 40 63,8 - …300-370 …300-370 …300-370 …300-370 …370
37 50 81,8 - - …370-450 …370-450 …370-450 …450
MOTOR TYPE 4 5,5 10,5 …40-75 …40-75 …40-75 …40-75 …40-75 …75
L6W HT - 6" 5,5 7,5 13,4 …40-75 …40-75 …40-75 …40-75 …40-75 …75
THREE-PHASE 7,5 10 17,3 …75-92 …75-92 …75-92 …75-92 …75-92 …150
9,3 12,5 20,8 - …92-110 …92-110 …92-110 …92-110 …150
11 15 23,9 - …110-150 …110-150 …110-150 …110-150 …150
13 17,5 28,4 - …110-150 …110-150 …110-150 …110-150 …150
15 20 32,5 - …150-185 …150-185 …150-185 …150-185 …220
18,5 25 41,6 - …185-220 …185-220 …185-220 …185-220 …220
22 30 49,7 - …220-300 …220-300 …220-300 …220-300 …300
26 35 55,8 - …220-300 …220-300 …220-300 …220-300 …300
30 40 68,8 - …300-370 …300-370 …300-370 …300-370 …370
TABELLA ABBINAMENTO POMPA-QUADRO COMANDO
For different voltages, please contact our sales network. L6w-2p50-en_c_tc
81
L10W - L12W MOTOR SERIES
TABELLA ABBINAMENTO POMPA-QUADRO COMANDO
MOTOR - CONTROL P ANEL COMBINA
PANEL TION T
COMBINATION ABLE
TABLE
MOTOR TYPE RATED RATED PANEL TYPE
L10W - 10" POWER CURRENT
THREE-PHASE 380-415 V
kW HP A Q3I/… Q3A/… Q3SF/…
93 125 191 …900-1100 …900-1100 …1100
110 150 235 …1100-1320 …1100-1320 …1100
130 175 270 …1320-1600 …1320-1600 (1)
150 200 308 …1600-2000 …1600-2000 (1)
MOTOR TYPE 83 110 170,2 …750-900 …750-900 …900
L10W HT - 10" 93 125 200,5 …900-1100 …900-1100 …1100
THREE-PHASE 110 150 233,0 …1100-1320 …1100-1320 …1100
130 175 288,0 …1320-1600 …1320-1600 (1)
(1) On request. L10w-2p50-en_c_tc
82
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
A C
0
1
LINEA
POWER
B
TERMICO
OVERLOAD
SERIE QTD
83
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
• Metal enclosure.
• Power, pump running, thermal
overload and dry running indicator V 300
500
L1-L2
L2-L3
L3-L1
A 150
200
lights.
50 0 25
0 0
M 0 A
SERIE Q3D
84
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
SPECIFICATIONS
SPECIFICATIONS • Ready for installation of dry running
• Manual control through an control float or pressure switch
Auto/Man selector switch. (to be ordered separately).
Q3Y Series • Automatic control through an Can be equipped with electronic
external enable contact. protection module with electrodes.
• Supply voltage:
3 x 400 V ±10%. OPTIONAL
• Frequency: 50/60 Hz. ACCES SORIES
ACCESSORIES
• 24 V AC low voltage auxiliary circuit. • KSL series 24 V level kit.
• Power: 4 to 315 kW. Probe module for protection against
• Star-delta starting. dry running (set of three electrodes
• Short-circuit and overload protection. included in the supply).
• Protection class: IP54. • Float.
• Ambient temperature: -5 to +40 °C • Pressure switch.
(according to EN 60439-1). • VR3/SCA3 three-phase module for
• Maximum relative humidity: 50% at overvoltage protection (lightning
+40°C, provided that no condensation protector).
occurs (according to EN 60439-1). A C
• Wall mounted.
• Metal enclosure.
• Power, pump running, thermal V 500
A 200
L2-L3
L1-L2 L3-L1
50 0 25
0 0
lights.
M 0 A
SERIE Q3Y
85
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
SPECIFICATIONS
SPECIFICATIONS • Ready for installation of dry running
• Manual control through an control float or pressure switch
Auto/Man selector switch. (to be ordered separately).
Q3I Series • Automatic control through an Can be equipped with electronic
external enable contact. protection module with electrodes.
• Supply voltage:
3 x 400 V ±10%. OPTIONAL
• Frequency: 50/60 Hz. ACCES SORIES
ACCESSORIES
• 24 V AC low voltage auxiliary circuit. • KSL series 24 V level kit.
• Power: 4 to 315 kW. Probe module for protection against
• Impedance start. dry running (set of three electrodes
• Short-circuit and overload protection. included in the supply).
• Protection class: IP54. • Float.
• Ambient temperature: -5 to +40 °C • Pressure switch.
(according to EN 60439-1). • VR3/SCA3 three-phase module for
• Maximum relative humidity: 50% at overvoltage protection (lightning
+40°C, provided that no condensation protector).
occurs (according to EN 60439-1). A C
• Wall mounted.
• Metal enclosure.
• Power, pump running, thermal V 500
A 200
L2-L3
L1-L2 L3-L1
50 0 25
0 0
lights.
M 0 A
SERIE Q3I
86
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
SPECIFICATIONS
SPECIFICATIONS • Ready for installation of dry running
• Manual control through an control float or pressure switch
Auto/Man selector switch. (to be ordered separately).
Q3A Series • Automatic control through an Can be equipped with electronic
external enable contact. protection module with electrodes.
• Supply voltage:
3 x 400 V ±10%. OPTIONAL
• Frequency: 50/60 Hz. ACCES SORIES
ACCESSORIES
• 24 V AC low voltage auxiliary circuit. • KSL series 24 V level kit.
• Power: 4 to 315 kW. Probe module for protection against
• Starting autotransformer. dry running (set of three electrodes
• Short-circuit and overload protection. included in the supply).
• Protection class: IP54. • Float.
• Ambient temperature: -5 to +40 °C • Pressure switch.
(according to EN 60439-1). • VR3/SCA3 three-phase module for
• Maximum relative humidity: 50% at overvoltage protection (lightning
+40°C, provided that no condensation protector).
occurs (according to EN 60439-1). A C
• Wall mounted.
• Metal enclosure.
• Power, pump running, thermal V 500
A 200
L2-L3
L1-L2 L3-L1
50 0 25
0 0
lights.
M 0 A
SERIE Q3A
87
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel SPECIFICATIONS
SPECIFICATIONS Protections against phase failure /
• Manual control through an phase sequence / frequency out of
Auto/Man selector switch. limits on power supply line.
• Automatic control through an Low-voltage protection on auxiliary
external enable contact. circuits.
Q3SF Series • Supply voltage: Protection against starter
3 x 400 V ±10%. overtemperature / overload /
• Frequency: 50/60 Hz. malfunction.
• 24 V AC low voltage auxiliary circuit. Protection against overload / locked
• Power: 5,5 to 110 kW. rotor / current asymmetry on motor
• Softstart with torque control. side.
• Protection class: IP54. Short-circuit protection on inputs
• Ambient temperature: -5 to +40 °C and outputs.
• Maximum relative humidity: 50% at RS232 interface for remote control
+40°C, provided that no condensation and RS485 for use of remote
occurs (according to EN 60439-1). keypanel.
• Wall mounted. Incorporated by-pass contactor.
• Metal enclosure.
• Dry running indicator light. OPTIONAL
• Power - pump running - malfunction ACCES SORIES
ACCESSORIES
LEDs on starter keypanel. • KSL series 24 V level kit.
• ON/OFF selector switch for activation Probe module for protection against
of by-pass contactor. dry running (set of three electrodes
• Ready for installation of dry running included in the supply).
control float or pressure switch • Float.
(to be ordered separately). • Pressure switch.
Can be equipped with electronic • VR3/SCA3 three-phase module for
protection module with electrodes. overvoltage protection (lightning
protector).
A C
STATIC ST
STA ARTER
STARTER
CHARACTERISTIC
CHARACTERISTICSS
• Static starter for gradual start-up/ M 0 A
shutdown, featuring:
keypanel with liquid crystal display
showing voltage, absorbed current,
cos ϕ, operating hours, number of
B
SERIE Q3SF
88
Level APPLICATIONS
APPLICATIONS
Control • Accessory for electric pump control panels, suitable for tank
filling or drainage applications or for activation of audible
Panel
or visual alarms.
A C
B
Control box
SERIE QCL5
89
Kit APPLICATIONS
APPLICATIONS
24 V Level • Accessory for electric panels.
Probe
SERIE SLD
QSCS-QM-QTD-Q3D-Q3Y-
KIT KSL/24 1x24 50/60 Hz 3,5 N0-C-NC 250 8 90 x 36 x 60 0,5
Q3A-Q3I-Q3SF
CB-SLD-en_b_te
90
Lightning APPLICATIONS
APPLICATIONS
Protection • Accessory for electric panels.
DPF Series
SPECIFICATIONS
SPECIFICATIONS
• Varistor for overvoltage protection of
single-phase lines. To be connected
between the phase and neutral
conductor.
• Operating voltage: 460 V AC.
• Maximum varistor voltage: 750 V
with 100 A peak current.
VR Series
SPECIFICATIONS
SPECIFICATIONS
• Varistors for overvoltage protection of
three-phase lines.
• To be connected between the phases
(VR3 model).
• Operating voltage: 460 V AC.
• Maximum varistor voltage: 750 V
with 100 A peak current.
• Designed for installation on Lowara
electric panels featuring DIN bar.
SCA3 Series
SPECIFICATIONS
SPECIFICATIONS
• Lightning arresters for overvoltage
protection of three-phase lines. To
be connected between the phases
and the heart conductor,
• Operating voltage: 500 V AC.
• Maximum varistor voltage: 2,5 kW
with 40 kA peak current.
• Designed for installation on Lowara
electric panels featuring DIN bar.
SERIE VR
91
COOLING SHROUDS
92
COOLING SHROUDS
Z10-Z12 PUMP SERIES
6”, 8”, 10” and 12” MOTORS COMBINA
DIMENSIONI E CODICI KIT RAFFREDDAMENTO
TION T
COMBINATION ABLE
TABLE
PUMP MOTOR COOLING COOLING COOLING
TYPE TYPE SET SET SET
L6C L6W L8W L10W L12W SHROUD FILTER BRACKETS
(D x L) (D x L1) (D)
11 11
Z10150 D285X1000 D285X325 D285 - 2PZ
- 13
15 15 D285X1000 D285X325 D285 - 2PZ
18,5 18,5
Z10150 22 22
D285X1250 D285X325 D285 - 2PZ
- 26
Z10220
30 -
- 30
D285X1500 D285X385 D285 - 3PZ
37 37
18,5 18,5
22 22
D330X1250 D330X385 D330 - 2PZ
- 26
Z10275
30 -
- 30
D330X1500 D330X385 D330 - 3PZ
37 37
30
D330X1250 D330X385 D330 - 2PZ
37
45
52
D330X1500 D330X385 D330 - 3PZ
Z10150 55
Z10220 60
67
75 D330X1750 D330X385 D330 - 3PZ
83
93 D330X2000 D330X385 D330 - 3PZ
30
D380X1250 D380X385 D380 - 2PZ
37
45
52
D380X1500 D380X385 D380 - 3PZ
Z10275 55
Z12340 60
67
75 D380X1750 D380X385 D380 - 3PZ
83
93 D380X2000 D380X385 D380 - 3PZ
30
D420X1250 D420X385 D420 - 2PZ
37
45
52
D420X1500 D420X385 D420 - 3PZ
55
Z12420
60
67
75 D420X1750 D420X385 D420 - 3PZ
83
93 D420X2000 D420X385 D420 - 3PZ
110
D330X2000 D330X385 D330 - 3PZ
Z10150 130
150 D330X2250 D330X385 D330 - 3PZ
Z10220 110
D380X2000 D380X385 D380- 3PZ
130
Z10275
150 D380X2250 D380X385 D380 - 3PZ
110
D420X2000 D420X385 D420 - 3PZ
Z12340 130
150 D420X2250 D420X385 D420 - 3PZ
110
D450X2000 D450X385 D450 - 3PZ
Z12420 130
150 D450X2250 D450X385 D450 - 3PZ
Z10150 185 D380X2000 D380X385 D380 - 3PZ
Z10220 220 D380X2250 D380X385 D380 - 3PZ
260 D380X2250 D380X385 D380 - 3PZ
Z10220
300 D380X2500 D380X385 D380 - 3PZ
185 D420X2000 D420X385 D420 - 3PZ
220
Z10275 D420X2250 D420X385 D420 - 3PZ
260
300 D420X2500 D420X385 D420 - 3PZ
185 D450X2000 D450X385 D450 - 3PZ
220
Z12340 D450X2250 D450X385 D450 - 3PZ
260
300 D450X2500 D450X385 D450 - 3PZ
185 D480X2000 D480X385 D480 - 3PZ
220
Z12420 D480X2250 D480X385 D480 - 3PZ
260
300 D480X2500 D480X385 D480 - 3PZ
Material : Stainless steel EN 10088-1 - X5CrNi18-10 (1.4301) AISI 304. (Other materials available on request). Z10-Z12_kit-raf50-en_b_ta
93
BOOSTER SHROUD
Variable
DN 125÷200 DN 125÷200
PN 10÷63 PN 10÷16
94
TECHNICAL
APPENDIX
95
SUBMERSIBLE ELECTRIC PUMP INSTALLA
INSTALLATION DIAGRAM
ALLATION
RECOMMENDATIONS
RECOMMENDATIONS
• Secure the drop cable to the pipe every 2÷3 meters of
piping.
• Make sure the electric pump is installed at a safe
distance from the bottom of the well.
• Make sure there is a minimum distance of 3 mm
between the diameter of the pump and the internal
diameter of the well.
• During operation, make sure that the water circulation
speed around the motor is at least 8 cm/sec.
• Make sure that the minimum dynamic level of the water
in the well is at least 1 m above the pump’s delivery port.
TECHNICAL APPENDIX 96
EXAMPLE OF INSTALLA
INSTALLATION OF A SUBMERSIBLE ELECTRIC
ALLATION
PUMP CONTROLLED B Y AN INVERTER (HYDRO
BY VAR®)
(HYDROV
97 TECHNICAL APPENDIX
MOTORI SERIE L6W - L8W - L10W - L12W
L6W - L8W - L10W - L12W MOTOR SERIES
TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
TYPE POWER °C
kW 25 30 35 40 45 50 55 60
EXAMPLE:
A 15 kW L6W motor is to be used in 35°C water.
Motor power at 35 °C = 15 x 0,75 = 11,25 kW
E.g.:
A 120 m long power cable must be matched with a 230V L4C07M235 motor.
To determine the cross-section of the cable, simply move along the row of the 230V motor until you find the maximum
lenght of 120 m or immediately above it and then read off the corresponding cross-section in that column.
In this case, between 101 and 161 metres, the second value corresponding to a 4 mm2 cable is selected.
N.B.: the tables include specific data (current and power factor) for each motor and voltage rating based on a
maximum voltage drop of 4% (HD 384.5), a maximum cable temperature of 80°C, water installation similar to air
installation at a temperature of 30°C.
TYPE OF CABLES
CABLE TYPES
THREE CORE FLAT FOUR CORE FLAT SINGLE CORE ROUND FOUR CORE ROUND
SECTION Hmin Lmin Hmax Lmax Weight Hmin Lmin Hmax Lmax Weight Dmin Dmax Weight Dmin Dmax Weight
2
mm mm mm mm mm kg/km mm mm mm mm kg/km mm mm kg/km mm mm kg/km
4 8 19,2 9 20,8 250 8 25,2 9 26,8 395 6,5 7,5 92 14 16,1 360
6 8 19,2 9 20,8 325 8 25,2 9 26,8 470 7,4 8 118 15,7 18 475
10 8 19,2 9 20,8 535 8 25,2 9 26,8 710 8,6 10 183 20,9 23,9 836
16 - - - - - - - - - - 9,6 11 251 23,8 27,1 1145
25 - - - - - - - - - - 11 13 362 28,9 32,9 1716
35 - - - - - - - - - - 12,5 14,5 497 - - -
50 - - - - - - - - - - 15 17 669 - - -
70 - - - - - - - - - - 17,5 19,5 901 - - -
95 - - - - - - - - - - 20,5 22,5 1141 - - -
120 - - - - - - - - - - 22 24,4 1435 - - -
150 - - - - - - - - - - 25,2 28,3 1795 - - -
185 - - - - - - - - - - 27,6 31 2156 - - -
240 - - - - - - - - - - 30,6 34,5 2760 - - -
L-cavi-en_a_td
TECHNICAL APPENDIX 98
L6W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),
L6W
L6W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DIRECT ST ART
START
Cable cross section: 4G x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm2 4 6 10 16 25 35 50 70
TYPE POWER VOLTAGE CURRENT DROP A max 42 54 75 100 127 158 192 246
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,90 9,89
L6W40T405 4 5,5 187 281 484
415 0,85 9,13
380 0,88 12,7
L6W55T405 5,5 7,5 148 222 384
415 0,82 12,5
380 0,90 17,0
L6W75T405 7,5 10 106 161 279 439
415 0,84 16,2
380 0,89 20,5
L6W93T405 9,3 12,5 87 133 233 366 561
415 0,83 19,9
380 0,90 24,2
L6W110T405 11 15 71 110 194 306 470
415 0,84 23,4
380 0,90 28,1
L6W130T405 13 17,5 60 93 165 262 403 561
415 0,85 27,0
4
380 0,88 32,1
L6W150T405 15 20 52 82 146 233 358 498
415 0,82 31,3
380 0,89 38,5
L6W185T405 18,5 25 - 65 118 190 294 410
415 0,83 37,5
380 0,87 47,3
L6W220T405 22 30 - 51 95,1 155 241 337 472
415 0,80 46,7
380 0,85 56,5
L6W260T405 26 35 - - 78 129 202 284 398
415 0,79 55,7
380 0,87 63,8
L6W300T405 30 40 - - 66 110 174 245 346 479
415 0,81 62,0
380 0,86 81,8
L6W370T405 37 50 - - - 82 132 188 267 372
415 0,80 79,4
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l6w-cavi-50-en_c_te
99 TECHNICAL APPENDIX
L6W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),
L6W
L6W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
STAR / DEL
STAR TA ST
DELT ART
START
Cable cross section: 4G x …mm2 + 3 x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm
2
4 6 10 16 25 35 50 70
TYPE POWER VOLTAGE CURRENT DROP A max* 73 94 130 173 220 274 333 426
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,90 9,89
L6W40T405 4 5,5 327 490
415 0,85 9,13
380 0,88 12,7
L6W55T405 5,5 7,5 260 389
415 0,82 12,5
380 0,90 17,0
L6W75T405 7,5 10 189 283 488
415 0,84 16,2
380 0,89 20,5
L6W93T405 9,3 12,5 157 237 408
415 0,83 19,9
380 0,90 24,2
L6W110T405 11 15 131 197 341 535
415 0,84 23,4
380 0,90 28,1
L6W130T405 13 17,5 111 169 293 460
415 0,85 27,0
4
380 0,88 32,1
L6W150T405 15 20 99 150 261 410
415 0,82 31,3
380 0,89 38,5
L6W185T405 18,5 25 80 122 214 337 517
415 0,83 37,5
380 0,87 47,3
L6W220T405 22 30 64 99,5 176 278 426
415 0,80 46,7
380 0,85 56,5
L6W260T405 26 35 53 83 148 236 362 502
415 0,79 55,7
380 0,87 63,8
L6W300T405 30 40 44 70,2 127 203 313 436
415 0,81 62,0
380 0,86 81,8
L6W370T405 37 50 - 52 96 157 243 340 476
415 0,80 79,4
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l6w-cavi-SD-50-en_c_te
L10W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR
L10W
L10W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
STAR / DEL
STAR TA ST
DELT ART
START
Cable cross section: 4G x …mm2 + 3 x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm
2
25 35 50 70 95 120 150 185
TYPE POWER VOLTAGE CURRENT DROP A max* 220 274 333 426 516 599 691 790
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,87 191
L10W930T405 93 125 90 132 191 269 345 428 511
415 0,84 180
380 0,86 235
L10W1100T405 110 150 - 102 150 215 278 345 412 480
415 0,82 220
4
380 0,86 270
L10W1300T405 130 175 - 85 127 183 238 297 356 415
415 0,83 255
380 0,86 308
L10W1500T405 150 200 - - 107 157 205 257 310 362
415 0,84 285
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l10w-cavi-SD-50-en_b_te
L12W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR
L12W
L12W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
STAR / DEL
STAR TA ST
DELT ART
START
Cable cross section: 4G x …mm2 + 3 x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm
2
50 70 95 120 150 185 240 300
TYPE POWER VOLTAGE CURRENT DROP A max* 333 426 516 599 691 790 932 1076
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,87 380
L12W1850T405 185 250 - 120 160 203 246 289 355 413
415 0,86 360
380 0,86 470
L12W2200T405 220 300 - - 123 158 193 229 282 329
415 0,83 435
4
380 0,87 525
L12W2600T405 260 350 - - - 137 169 202 251 294
415 0,83 498
380 0,87 620
L12W3000T405 300 400 - - - - 138 166 208 245
415 0,84 570
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l12w-cavi-SD-50-en_b_te
2
MOTOR FOUR-CORE DROP CABLE - SECTION (mm )
POWER kW TYPE OF SPLICE
TYPE
1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
Resin-filled method GR1 GR1 GR1 GR2 GR2 GR6 GR6 GR6 GR4 GR5 GR5 - - - - -
4OS
0,37 - 7,5 Heat-shrink method GT1 GT1 GT2 GT2 GT3 GT4 GT5 GT6 - - - - - - - -
L4C
Tape method Self-vulcanizing tape + self-vulcanizing sealing putty and PVC tape (1)
Resin-filled method - - GR1 GR2 GR2 GR6 GR6 GR6 GR4 GR5 GR5 - - - - -
L6C
4 - 37 Heat-shrink method - - GT2 GT2 GT3 GT4 GT5 GT6 - - - - - - - -
L6W
Tape method Self-vulcanizing tape + self-vulcanizing sealing putty and PVC tape (1)
Resin-filled method - - GR1 GR1 GR2 GR2 GR6 GR6 GR6 GR4 GR5 - - - - -
L6C
4 - 37 Heat-shrink method - - GT2 GT2 GT3 GT4 GT5 GT6 - - - - - - - -
L6W
Resin-filled method - - - GR1 GR1 GR1 GR1 GR1 GR1 GR2 GR2 GR2 GR6 GR6 GR6 GR4
L8W
L10W 30 - 300 Heat-shrink method - - - - - - - - - - - - - - - -
L12W
Tape method Self-vulcanizing tape + PVC tape
(1) Use self-vulcanizing sealing putty to fill in the gaps between the three-conductor cable and the ground cable in the area covered
The following formula is used to verify whether the speed of the fluid that flows around the motor of a submersible pump is high
enough to guarantee the proper cooling of the motor:
Q
v= 2
2
D2 d
π ⋅( − )
4 4
Where: Q in [m3/s] is the operating flow rate of the electric pump; only half of this flow is taken into account, because the fluid
which is sucked into the area of the filter (2), comes from the motor side (3) as well as from the pump side (1);
D in [m] corresponds to the diameter of the well;
d in [m] corresponds to the diameter of the motor (3);
v in [m/s] is the calculated speed of the fluid that flows around the motor.
Now, compare the speed thus calculated (v) with the minimum speed required for correct cooling of the motor (vm): if v ≥ vm it
means that the motor is properly cooled, if v < vm will be necessary to mount a cooling sleeve (4).
Example
Example:
An electric pump OZ630/12 (motor diameter d = 0.144 m) operates in an 8" well (well diameter D = 0.203 m) with flow rate
Q = 20 m3/h = 0.0055 m3/s.
Speed of fluid v = (0.0055/2) / {π·[(0.203)2/4 – (0.144)2/4]} = 0.17 m/s.
The minimum speed required for proper motor cooling is vm = 0.20 m/s.
Because v < vm, it will be necessary to mount a cooling sleeve.
The following formula is used to determine the maximum diameter of a cooling sleeve to be mounted on a submersible motor:
⎛ Q d2 ⎞
D = 4 ⋅ ⎜⎜ + ⎟
⎝ v ⋅π 4 ⎟⎠
Where: Q in [m3/s] is the operating flow rate of the electric pump; the entire flow is taken into account because the fluid comes
from the motor side (3) only;
D in [m] corresponds to the diameter of the cooling sleeve (4);
d in [m] corresponds to the diameter of the motors(3);
vm in [m/s] is the minimum speed of the fluid that flows around the motor.
If the electric pump operates at different flow rate, the minimum flow rate must be taken into account for calculating the diameter
of the cooling sleeve.
Example
Example:
A motor coupled to the electric pump OZ615/24 (motor diameter d = 0.144 m), which operates with flow rate
Q = 15 m3/h = 0.0042 m3/s, requires a minimum speed of the fluid of vm = 0.20 m/s.
Cooling sleeve diameter D = {4·[(0.0042/(0.2·π)+(0.144)2/4] }0.5 = 0.217 m.
Direct Autotransformer
Suitable for low-power motors.
The pump is started with a voltage which is lower than
The starting current (Is) is much higher than the rated
the rated one.
current (In).
The Lowara panels use an autotransformer with a voltage
Starting current Is = In x 4 ÷ 8
that is 70% the value of the line voltage.
Starting torque Ts = Tn x 2 ÷ 3
The switch to the rated voltage occurs without any
interruptions of the power supply.
Indirect Rated voltage Un = 400 V
• Star/Delta
The starting current (Is) is three times less than the direct
starting current. Starting current
Starting current Is = In x 1.3 ÷ 2.7 Us
Starting torque Ts = Tn x 0.7 ÷ 1
In the star to delta changeover phase (approx. 70 ms) the
motor is not supplied and tends to reduce its rotation Starting torque
Is = In x 4÷8 x
( ) Un
= In x 3÷6
speed. Us
( )
2
• Impedances Ia
Starting current
( )
Us
Is = In x 4÷8 x = In x 3÷6
Un
1 = Direct SPEED’
2 = Star-Delta
Starting torque 3 = Impedances
4 = Autotransformer
( )
Us 2
Ts = Tn x 2÷3 x = Tn x 1÷1,5
Un
The consumption table shows the maximum values for each delivery point, depending on the plumbing amenities.
The sum of the water consumption values of each delivery point determines the maximum theoretical re-
quirement, which must be reduced according to the contemporaneity coefficient, because in actual fact the
delivery points are never used all together.
1
f = Coefficient for apartments with one bathroom and flush tank WC
(0,857 x Nr x Na)
1
f = Coefficient for apartments with one bathroom and controlled flushing system WC
(0,857 x Nr x Na)
1,03
f = Coefficient for apartments with two bathrooms and flush tank WC
(0,545 x Nr x Na )
0,8
f = Coefficient for apartments with two bathrooms and controlled flushing system WC
(0,727 x Nr x Na )
f= coefficient; Nr= number of delivery points; Na= number of apartments
The table of water requirements in civil users shows the maximum contemporaneity flow-rate values
based on the number of apartments and the type of WC for apartments with one bathroom and two bath-
rooms. As regards apartments with one bathroom, 7 drawing points have been taken into consideration, while 11
points have been considered for apartments with two bathrooms. If the number of drawing points or apartments is
different, use the formulas to calculate the requirement.
For seaside resorts, the flow rate must be increased by at least 20%.
The minimum operating values that can be reached at the The maximum possible suction head for installation
pump suction end are limited by the onset of cavitation. depends on the value of the atmospheric pressure
(i.e. the elevation above sea level at which the pump
Cavitation is the formation of vapour-filled cavities within is installed) and the temperature of the liquid.
liquids where the pressure is locally reduced to a critical value,
or where the local pressure is equal to, or just below the To help the user, with reference to water temperature
vapour pressure of the liquid. (4° C) and to the elevation above sea level, the
following tables show the drop in hydraulic pressure
The vapour-filled cavities flow with the current and head in relation to the elevation above sea level, and
when they reach a higher pressure area the vapour the suction loss in relation to temperature.
contained in the cavities condenses. The cavities collide,
generating pressure waves that are transmitted to the Water
walls. These, being subjected to stress cycles, gradually temperature (°C) 20 40 60 80 90 110 120
become deformed and yield due to fatigue. This Suction
phenomenon, characterized by a metallic noise loss (m) 0,2 0,7 2,0 5,0 7,4 15,4 21,5
produced by the hammering on the pipe walls, is called
incipient cavitation.
Elevation above
sea level (m) 500 1000 1500 2000 2500 3000
The damage caused by cavitation may be magnified by
electrochemical corrosion and a local rise in Suction
temperature due to the plastic deformation of the loss (m) 0,55 1,1 1,65 2,2 2,75 3,3
walls. The materials that offer the highest resistance to
heat and corrosion are alloy steels, especially austenitic
steel. The conditions that trigger cavitation may be Friction loss is shown in the tables at pages 113-114 of
assessed by calculating the total net suction head, this catalogue. To reduce it to a minimum, especially
referred to in technical literature with the acronym in cases of high suction head (over 4-5 m.) or within
NPSH (Net Positive Suction Head). the operating limits with high flow rates, we
recommend using a suction line having a larger
The NPSH represents the total energy (expressed in m.) diameter than that of the pump’s suction port.
of the liquid measured at suction under conditions of It is always a good idea to position the pump as close
incipient cavitation, excluding the vapour pressure as possible to the liquid to be pumped.
(expressed in m.) that the liquid has at the pump inlet.
Make the following calculation:
To find the static height hz at which to install the
machine under safe conditions, the following formula Liquid: water at ~15°C γ = 1 kg/dm3
must be verified: Flow rate required: 30 m3/h
Head for required delivery: 43 m.
Suction lift: 3,5 m.
hp + hz ≥ (NPSHr + 0.5) + hf + hpv 1 The selection is an FHE 40-200/75 pump whose NPSH
required value is, at 30 m3/h, di 2,5 m.
where:
hp is the absolute pressure applied to the free liquid For water at 15 °C
surface in the suction tank, expressed in m. of
liquid; hp is the quotient between the barometric hp = Pa / γ = 10,33m, hpv = Pv / γ = 0,174m (0,01701 bar)
pressure and the specific weight of the liquid.
The Hf flow resistance in the suction line with foot
hz is the suction lift between the pump axis and the
valves is ~ 1,2 m.
free liquid surface in the suction tank, expressed
By substituting the parameters in formula 1 with the
in m.; hz is negative when the liquid level is
numeric values above, we have:
lower than the pump axis.
hf is the flow resistance in the suction line and its
10,33 + (-3,5) ≥ (2,5 + 0,5) + 1,2 + 0,17
accessories, such as: fittings, foot valve, gate
valve, elbows, etc. from which we have: 6,8 > 4,4
hpv is the vapour pressure of the liquid at the
operating temperature, expressed in m. of The relation is therefore verified.
liquid. hpv is the quotient between the Pv vapour
pressure and the liquid’s specific weight.
0,5 is the safety factor.
t T ps ρ t T ps ρ t T ps ρ
°C K bar kg/dm3 °C K bar kg/dm3 °C K bar kg/dm3
0 273,15 0,00611 0,9998 55 328,15 0,15741 0,9857 120 393,15 1,9854 0,9429
1 274,15 0,00657 0,9999 56 329,15 0,16511 0,9852 122 395,15 2,1145 0,9412
2 275,15 0,00706 0,9999 57 330,15 0,17313 0,9846 124 397,15 2,2504 0,9396
3 276,15 0,00758 0,9999 58 331,15 0,18147 0,9842 126 399,15 2,3933 0,9379
4 277,15 0,00813 1,0000 59 332,15 0,19016 0,9837 128 401,15 2,5435 0,9362
5 278,15 0,00872 1,0000 60 333,15 0,1992 0,9832 130 403,15 2,7013 0,9346
6 279,15 0,00935 1,0000 61 334,15 0,2086 0,9826 132 405,15 2,867 0,9328
7 280,15 0,01001 0,9999 62 335,15 0,2184 0,9821 134 407,15 3,041 0,9311
8 281,15 0,01072 0,9999 63 336,15 0,2286 0,9816 136 409,15 3,223 0,9294
9 282,15 0,01147 0,9998 64 337,15 0,2391 0,9811 138 411,15 3,414 0,9276
10 283,15 0,01227 0,9997 65 338,15 0,2501 0,9805 140 413,15 3,614 0,9258
11 284,15 0,01312 0,9997 66 339,15 0,2615 0,9799 145 418,15 4,155 0,9214
12 285,15 0,01401 0,9996 67 340,15 0,2733 0,9793 155 428,15 5,433 0,9121
13 286,15 0,01497 0,9994 68 341,15 0,2856 0,9788 160 433,15 6,181 0,9073
14 287,15 0,01597 0,9993 69 342,15 0,2984 0,9782 165 438,15 7,008 0,9024
15 288,15 0,01704 0,9992 70 343,15 0,3116 0,9777 170 433,15 7,920 0,8973
16 289,15 0,01817 0,9990 71 344,15 0,3253 0,9770 175 448,15 8,924 0,8921
17 290,15 0,01936 0,9988 72 345,15 0,3396 0,9765 180 453,15 10,027 0,8869
18 291,15 0,02062 0,9987 73 346,15 0,3543 0,9760 185 458,15 11,233 0,8815
19 292,15 0,02196 0,9985 74 347,15 0,3696 0,9753 190 463,15 12,551 0,8760
20 293,15 0,02337 0,9983 75 348,15 0,3855 0,9748 195 468,15 13,987 0,8704
21 294,15 0,24850 0,9981 76 349,15 0,4019 0,9741 200 473,15 15,550 0,8647
22 295,15 0,02642 0,9978 77 350,15 0,4189 0,9735 205 478,15 17,243 0,8588
23 296,15 0,02808 0,9976 78 351,15 0,4365 0,9729 210 483,15 19,077 0,8528
24 297,15 0,02982 0,9974 79 352,15 0,4547 0,9723 215 488,15 21,060 0,8467
25 298,15 0,03166 0,9971 80 353,15 0,4736 0,9716 220 493,15 23,198 0,8403
26 299,15 0,03360 0,9968 81 354,15 0,4931 0,9710 225 498,15 25,501 0,8339
27 300,15 0,03564 0,9966 82 355,15 0,5133 0,9704 230 503,15 27,976 0,8273
28 301,15 0,03778 0,9963 83 356,15 0,5342 0,9697 235 508,15 30,632 0,8205
29 302,15 0,04004 0,9960 84 357,15 0,5557 0,9691 240 513,15 33,478 0,8136
30 303,15 0,04241 0,9957 85 358,15 0,5780 0,9684 245 518,15 36,523 0,8065
31 304,15 0,04491 0,9954 86 359,15 0,6011 0,9678 250 523,15 39,776 0,7992
32 305,15 0,04753 0,9951 87 360,15 0,6249 0,9671 255 528,15 43,246 0,7916
33 306,15 0,05029 0,9947 88 361,15 0,6495 0,9665 260 533,15 46,943 0,7839
34 307,15 0,05318 0,9944 89 362,15 0,6749 0,9658 265 538,15 50,877 0,7759
35 308,15 0,05622 0,9940 90 363,15 0,7011 0,9652 270 543,15 55,058 0,7678
36 309,15 0,05940 0,9937 91 364,15 0,7281 0,9644 275 548,15 59,496 0,7593
37 310,15 0,06274 0,9933 92 365,15 0,7561 0,9638 280 553,15 64,202 0,7505
38 311,15 0,06624 0,9930 93 366,15 0,7849 0,9630 285 558,15 69,186 0,7415
39 312,15 0,06991 0,9927 94 367,15 0,8146 0,9624 290 563,15 74,461 0,7321
40 313,15 0,07375 0,9923 95 368,15 0,8453 0,9616 295 568,15 80,037 0,7223
41 314,15 0,07777 0,9919 96 369,15 0,8769 0,9610 300 573,15 85,927 0,7122
42 315,15 0,08198 0,9915 97 370,15 0,9094 0,9602 305 578,15 92,144 0,7017
43 316,15 0,09639 0,9911 98 371,15 0,9430 0,9596 310 583,15 98,70 0,6906
44 317,15 0,09100 0,9907 99 372,15 0,9776 0,9586 315 588,15 105,61 0,6791
45 318,15 0,09582 0,9902 100 373,15 1,0133 0,9581 320 593,15 112,89 0,6669
46 319,15 0,10086 0,9898 102 375,15 1,0878 0,9567 325 598,15 120,56 0,6541
47 320,15 0,10612 0,9894 104 377,15 1,1668 0,9552 330 603,15 128,63 0,6404
48 321,15 0,11162 0,9889 106 379,15 1,2504 0,9537 340 613,15 146,05 0,6102
49 322,15 0,11736 0,9884 108 381,15 1,3390 0,9522 350 623,15 165,35 0,5743
50 323,15 0,12335 0,9880 110 383,15 1,4327 0,9507 360 633,15 186,75 0,5275
51 324,15 0,12961 0,9876 112 385,15 1,5316 0,9491 370 643,15 210,54 0,4518
52 325,15 0,13613 0,9871 114 387,15 1,6362 0,9476 374,15 647,30 221,20 0,3154
53 326,15 0,14293 0,9862 116 389,15 1,7465 0,9460
54 327,15 0,15002 0,9862 118 391,15 1,8628 0,9445
G-at_npsh_a_sc
The flow resistance is calculated using the equivalent pipeline length method according to the table below:
ACCESSORY DN
TYPE 25 32 40 50 65 80 100 125 150 200 250 300
Equivalent pipeline length (m)
45° bend 0,2 0,2 0,4 0,4 0,6 0,6 0,9 1,1 1,5 1,9 2,4 2,8
90° bend 0,4 0,6 0,9 1,1 1,3 1,5 2,1 2,6 3,0 3,9 4,7 5,8
90° smooth bend 0,4 0,4 0,4 0,6 0,9 1,1 1,3 1,7 1,9 2,8 3,4 3,9
Union tee or cross 1,1 1,3 1,7 2,1 2,6 3,2 4,3 5,3 6,4 7,5 10,7 12,8
Gate - - - 0,2 0,2 0,2 0,4 0,4 0,6 0,9 1,1 1,3
Non return valve 1,1 1,5 1,9 2,4 3,0 3,4 4,7 5,9 7,4 9,6 11,8 13,9
G-a-pcv_a_th
The table is valid for the Hazen Williams coefficient C = 100 (cast iron pipework). For steel pipework, multiply the
values by 1.41. For stainless steel, copper and coated cast iron pipework, multiply the values by 1.85.
When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of
flow resistance.
The values given are guideline values which are bound to vary slightly according to the model, especially for gate
valves and non-return valves, for which it is a good idea to check the values supplied by the manufacturers.
PRESSURE
SURE
PRESSURE
PRES AND HEAD
AND HEAD
Newton per kilo Pascal bar Pound force per metre millimetre of
square metre square inch of water mercury
N/m2 kPa bar psi m H 2O mm Hg
1,0000 0,0010 1 x 10-5 1.45 x 10-4 1.02 x 10-4 0,0075
1000,0000 1,0000 0,0100 0,1450 0,1020 7,5006
1 x 105 100,0000 1,0000 14,5038 10,1972 750,0638
6894,7570 6,8948 0,0689 1,0000 0,7031 51,7151
9806,6500 9,8067 0,0981 1,4223 1,0000 73,5561
133,3220 0,1333 0,0013 0,0193 0,0136 1,0000
LENGTH
TH
LENGTH
LENG
millimetre centimetre metre inch foot yard
mm cm m in ft yd
VOLUME
V OLUME
OLUME
cubic metre litre millilitre imp. Gallon US gallon cubic foot
3
m litro ml imp. gal. US gal. ft3
Xylect
Xylect is pump solution selection software with an extensive online database of product information across the entire
Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management
facilities. The system holds up-to-date product information on thousands of products and accessories.
The possibility to search by applications and the detailed information output given makes it easy to make the optimal
selection without having detailed knowledge about the Lowara and Vogel products.
Xylect
The detailed output makes it easy to select the optimal pump from the given alternatives.
For more information about Xylect please contact Dimensional drawings appear on the screen and can be
our sales network or visit www.xylect.com. downloaded in dxf format.
Headquarters
LOWARA S.r.l. Unipersonale
Via Vittorio Lombardi 14
36075 Montecchio Maggiore - Vicenza - Italy
Tel.(+39) 0444 707111 - Fax(+39) 0444 492166
e-mail: [email protected]
web: www.lowara.com - www.completewatersystems.com
LOWARA reserves the right to make modification without prior notice.
LOWARA is a trademark of Xylem Inc. or one of its subsidiaries.