Lenntech GRUNDFOS ALLDOS DATA BOOKLET

[email protected]
www.lenntech.com

DMI

Dosing
Contents DMI

Features and benefits


DMI dosing pumps 3
Examples of applications 3

Performance range
DMI, 50 Hz 4
DMI, 60 Hz 5

Identification
Type key 6

Functions
Control variants 7
Options 7
Functions 7
Capacity control 8

Construction
General description 10
DMI with manual deaeration 10
DMI with Plus3 system 11
Functional principle of the Plus3 system 12
Spring-loaded valves 12

Technical data
Dimensions 13
Performance data 15
Suction lift 16
Inlet pressure and counter pressure 16
Permissible temperature range of the pumped media 17
Electrical data 17
Additional technical data 17

Pump selection
DMI selection (0.3 to 18 l/h) 18

Pumped media
List of pumped media 20

Further product documentation


WebCAPS 21
WinCAPS 22

2 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Features and benefits DMI

DMI dosing pumps The DMI A or B: With or without signal inputs


The DMI range is suitable for a wide range of dosing
Simple and cost-efficient dosing tasks. Choose between control variant B, designed for
from 0.3 to 18 l/h simple manual control, or control variant A which offers
more sophisticated control features. Examples
include:
• pulse control with multiplier/divisor that con-
verts signals into strokes as appropriate

GrA3475 / GrA3482
• stroke-frequency control
• access to check functions and venting
• optional memory function.
Choose between control options
Fig. 1 DMI B Fig. 2 DMI A The DMI A (AR) series can be set to either proportional
control or manual dosing by pressing a key. Pulse
Variations on the synchronous-motor theme control mode allows proportional control according to
The Grundfos DMI range of dosing pumps comprises external contact signals from a flowmeter or other
several variants for general or specific dosing pur- device.
poses. Dosing heads and valves are available in differ-
ent materials to suit a wide range of general water Examples of applications
treatment and industrial applications. • industrial and municipal water treatment •
water treatment in cooling towers •
Whichever model you choose, you get a sturdy, cost-
efficient pump based on a well-proven synchronous- industrial cleaning •
motor design. The DMI range can dose rates from 0.3 Cleaning-In-Place (CIP) and disinfection
to 18 l/h and pressures up to 16 bar. (dairies,
food and beverage industries, etc.)
Silent operation
• paper production/finishing
Regardless of model, the DMI pump is among the most
silent of its type available on the market today. It keeps • chemical industry
its noise levels down to just 45 dB(A). • chemigation
• galvanic and surface treatment
Flexible installation
• plating
The Grundfos DMI is suitable for both horizontal and
vertical installation. If installed horizontally, the control • water treatment in swimming pools
elements are located on the top of the unit for easy • semiconductor industry.
access.

Proven synchronous-motor technology


The synchronous-motor technology used in the Grund-
fos DMI range combines robustness and precision. It
keeps pulsation low and performance high.

[email protected] - Tel.+31(0)15-261.09.00 3
www.lenntech.com - Fax.+31(0)15-261.62.89
Performance range DMI

DMI, 50 Hz

p
[bar]
DMI
16 50 Hz

14

12

10

1 2 3 4 5 6 7 8 9 10 11 12 13
2

TM03 8131 0507


0
0.1
0 0.2 0.3 0.4 0.5 0.6 0.8 1 2 3 4 5 6 8 10 20
Q [l/h]

Fig. 3 Performance range, DMI at 50 Hz

Pos. Pump
1 DMI 0.3-10
2 DMI 0.8-16
3 DMI 1.0-10
4 DMI 1.1-16
5 DMI 1.6-10
6 DMI 3.0-10
7 DMI 3.6-16
8 DMI 4.0-8
9 DMI 5.0-6
10 DMI 6.0-8
11 DMI 9.0-6
12 DMI 14-4
13 DMI 18-3.5

4 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Performance range DMI

DMI, 60 Hz

p
[bar] DMI
16 60 Hz

14

12

10

1 2 3 4 5 6 7 8 9 10 11 12 13
2

TM03 8251 0907


0
0.1
0 0.2 0.3 0.4 0.5 0.6 0.8 1 1.5 2 3 4 5 6 8 10 15 20 30
Q [l/h]

Fig. 4 Performance range, DMI at 60 Hz

Pos. Pump
1 DMI 0.3-10
2 DMI 0.8-16
3 DMI 1.0-10
4 DMI 1.1-16
5 DMI 1.6-10
6 DMI 3.0-10
7 DMI 3.6-16
8 DMI 4.0-8
9 DMI 5.0-6
10 DMI 6.0-8
11 DMI 9.0-6
12 DMI 14-4
13 DMI 18-3.5

[email protected] - Tel.+31(0)15-261.09.00 5
www.lenntech.com - Fax.+31(0)15-261.62.89
Identification DMI

Type key

Example: DMI 1.6 - 10 A PVC /V /G -T -H 1 33 B

Type range Mains plug

DMI X No plug
F EU (Schuko)
Maximum flow [l/h]
B USA, Canada
I Australia, New Zealand, Taiwan
Maximum pressure [bar]
E Switzerland

Control variant Connection, suction/discharge

B Without external control interface B6 Pipe, 4/6 mm

Internal frequency control and 3 Tube, 4/6 mm


A
external contact-signal control A5 Tube, 5/8 mm
Internal frequency control, 4 Tube, 6/9 mm
AR external contact-signal control and
alarm relay 6 Tube, 9/12 mm

C4 Tube, 1/8" / 1/4"


Dosing head variant
R Tube, 1/4" / 3/8"
PP Polypropylene S Tube, 3/8" / 1/2"
PV PVDF (polyvinylidene fluoride) A Threaded, Rp 1/4, female
PVC Polyvinyl chloride V Threaded, 1/4" NPT, female
SS Stainless steel, DIN 1.4401 A9 Threaded, 1/2" NPT, male
PP-P3 PP with Plus3 B1 Tube, 6/12 mm/cementing d. 12 mm
PVC-P3 PVC with Plus3 B3 Welding diameter, 16 mm

Gasket material Valve type

E EPDM 1 Standard
V FKM Spring-loaded
2 0.05 bar suction opening pressure;
T PTFE 0.05 bar discharge opening pressure
Spring-loaded
Valve ball material 3 0.05 bar suction opening pressure;
0.8 bar discharge opening pressure
C Ceramic Spring-loaded, discharge only
4
G Glass 0.8 bar opening pressure

T PTFE
Supply voltage
SS Stainless steel, DIN 1.4401
G 1 x 230 V, 50/60 Hz
Control panel position
H 1 x 120 V, 50/60 Hz
T Top-mounted
X No control panel

6 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Functions DMI

Control variants Functions


Control variants Control variants
Features Electronic function Socket
B A AR A AR
Stroke-length adjustment z z z Relay function Output socket 3 Stroke
Internal frequency control z z Remote on/off Input socket 4 NO NO
External contact-signal control z z Pre-empty signal Input socket 5 NO NO
Relay output z Empty signal Input socket 5 NO NO
Error signal Output socket 3 NO
Relay Output socket 3 NO
Contact signal Input socket 4 z z
NO: Normally open

GrA3475 / GrA3482

Fig. 5 DMI B Fig. 6 DMI A

Options
Pump Plus3 system*
DMI 0.3-10 z
DMI 0.8-16 z
DMI 1.0-10 z
DMI 1.1-16 z
DMI 1.6-10 z
DMI 3.0-10 z
DMI 3.6-10 z
DMI 4.0-8 z
DMI 5.0-6
DMI 6.0-8 z
DMI 9.0-6
DMI 14-4
DMI 18-3.5
* See page 11.
GrA3483

Fig. 7 DMI B with Plus3

[email protected] - Tel.+31(0)15-261.09.00 7
www.lenntech.com - Fax.+31(0)15-261.62.89
Functions DMI

Capacity control
The capacity can be controlled in three ways:
Manual
• by adjusting the stroke length 1:n 1:16 1:32 Contact
Mode 1:8 90 100 %
• by stroke-frequency control 80
1:4
70
• by external pulse control.
60 0
1:2 32:1
50 10
1:1 40 20 16:1
30
n:1 2:1 8:1
4:1

TM03 3647 0506


1:n f%

Fig. 8 Control and display elements, control variant A

Capacity control by adjusting the stroke length


The stroke length is adjusted be means of the stroke-
length adjusting knob.

Q
[gph]
TM03 4643 0506

TM03 3883 1106


l [%]

Fig. 9 Capacity control by adjusting the stroke Fig. 10 Relation between stroke length (I)
length and capacity (Q)

Stroke
Discharge
length Duration
100%
Suction
Discharge
Duration
50%
Suction
TM03 2074 3505

Discharge
Duration
10%
Suction

Fig. 11 Relation between stroke length and capacity

8 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Functions DMI

Stroke-frequency control
The suction and discharge stroke speeds are constant,
while the stroke frequency varies according to the fre-
quency set.
Capacity
setting Discharge
Duration
100%

Suction
Discharge
Duration
50%
Suction
Discharge

TM01 8945 0900


Duration
10%
Suction

Fig. 12 Dosing principle, control variant A/AR, internal frequency control

External pulse control

Setting Function Number of strokes per contact signal Example


1:1 1:1 The pump makes one dosing stroke per contact signal received. One stroke per contact signal for the setting 1:1.
The pump makes the set number of dosing strokes per contact sig-
1:n Multiplier 16 strokes per contact signal for the setting 1:16.
nal received.
The pump makes one dosing stroke after the set number of contact
n:1 Divisor One stroke for every four contact signals for the setting 4:1.
signals has been received.

[email protected] - Tel.+31(0)15-261.09.00 9
www.lenntech.com - Fax.+31(0)15-261.62.89
Construction DMI

General description
The DMI pump is powered by an overload-protected
synchronous motor.
The DMI is available with several options on the pump
head:
• manual deaeration (standard)
• Plus3 system.
As an option, the pump can also be equipped with
spring-loaded valves for viscous liquids.

DMI with manual deaeration

TM03 3623 0506

Fig. 13 Sectional drawing, DMI with manual deaeration

Legend

Pos. Component
1a Suction valve
1b Discharge valve
2a Dosing head with manual deaeration
3 Connection for deaeration line
4 Manual bleed/deaeration valve

10 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Construction DMI

DMI with Plus3 system


The Plus3 system incorporates priming/deaeration and
calibration system for moderately volatile liquids (chlo-
rine bleaching agents).

TM03 3624 0506

Fig. 14 Sectional drawing, DMI with Plus3 system

Legend

Pos. Component
1a Suction valve
1b Discharge valve
2c Dosing head with Plus 3 system
3 Connection for deaeration line
4 Manual deaeration valve
5 Suction line from tank
6 Line from calibration tube (pos. 8) to dosing head (pos. 2c)
7 Isolating valve at calibration tube (pos. 8)
8 Calibration tube
9 Priming/deaeration chamber
10 Connection for overflow line (pos. 11)
11 Overflow line to the tank (PVC tube 8/11 mm)
12 Deaeration line to the tank
13 Dosing line (discharge line)
14 Cover
15 Adhesive label
16 Deaeration hole

[email protected] - Tel.+31(0)15-261.09.00 11
www.lenntech.com - Fax.+31(0)15-261.62.89
Construction DMI

Functional principle of the Plus3 system Spring-loaded valves


The pump head can be supplied with spring-loaded
valves for improved performance when handling vis-
5 6 cous liquids. Some of these valves have a larger nomi-
nal width and incorporate adapters.
Note: The suction and discharge dimensions of the
3 pump may change when the pump is fitted with spring-
loaded valves.

2
7 TM03 4500 2206
1
8 4

Fig. 15 Functional principle of the Plus3 system

Legend

Pos. Component
1 Inlet from tank
2 Conveying diaphragm
3 Priming/deaeration chamber
4 Dosing diaphragm
5 Discharge to the process line
6 Deaeration bypass
7 Calibration tube
8 Calibration valve

Operation of the Plus3 system


• The conveying diaphragm (2) draws a large volume
of liquid from the supply tank (1) and pumps it into
the priming/deaeration chamber (3).
• Any bubbles in the liquid are vented to the atmos-
phere in the priming chamber.
• The separate, working diaphragm (4) pumps the liq-
uid into the process line (5).
• Any excess liquid is returned to the tank via the de-
aeration bypass (6).
• The integrated calibration column (7) and calibration
valve (8) allow precise adjustment of the flow while
the pump is running.
Designed especially for volatile chemicals, the double-
diaphragm system offers high process accuracy and
cost-efficient operation.
An additional feature of the Plus 3 system is that the
priming chamber allows the pump to be in a suction lift
configuration. This permits the exchange of chemical
tanks without interrupting the chemical discharge to the
system.

12 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI

Dimensions
DMI

20

10
30

0
40
50
60

100%
70

90
80

TM03 3479 0406

Fig. 16 Dimensions, DMI

Dimensions

A B C D E C HV* D HV* E HV*


Pump
[mm] [mm] [mm] [mm] [mm] [mm]
DMI 0.3-10 225 20.7 175.5 112 G 3/8 175.5 112 G 3/8
DMI 0.8-16 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 1-10 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 1.1-16 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 1.6-10 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 3-10 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 3.6-16 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 4-8 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 5-6 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 6-8 225 20.7 175.5 112 G 3/8 207.5 176 G 5/8
DMI 9-6 230 26.7 184.5 133 G 3/8 184.5 133 G 5/8
DMI 14-4 230 26.7 184.5 133 G 3/8 184.5 133 G 5/8
DMI 18-4 230 26.7 184.5 133 G 3/8 184.5 133 G 5/8
* HV = Pump version for high-viscosity liquids

[email protected] - Tel.+31(0)15-261.09.00 13
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI

DMI with Plus3 system

TM03 3481 0406


Fig. 17 Dimensions of DMI with Plus3 system

Dimensions
A1 B1 C1 D1 E1
Pump
[mm] [mm] [mm] [mm]
DMI 0.3-10 261 25.2 251 197.5 G 3/8
DMI 0.8-16 261 25.2 251 197.5 G 3/8
DMI 1-10 261 25.2 251 197.5 G 3/8
DMI 1.1-16 261 25.2 251 197.5 G 3/8
DMI 1.6-10 261 25.2 251 197.5 G 3/8
DMI 3-10 261 25.2 251 197.5 G 3/8
DMI 3.6-16 261 25.2 251 197.5 G 3/8
DMI 4-8 261 25.2 251 197.5 G 3/8
DMI 5-6 - - - - -
DMI 6-8 261 25.2 251 197.5 G 3/8
DMI 9-6 - - - - -
DMI 14-4 - - - - -
DMI 18-4 - - - - -

14 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI

Performance data
50 Hz 60 Hz
Vstroke
Pump Capacity 1)
Pmax 2) Max. stroke rate Capacity 1)
Pmax2) Max. stroke rate
[cm3]
[l/h] [bar] [strokes/min] [l/h] [bar] [strokes/min]
DMI 0.3-10 0.04 0.3 10 120 0.36 10 145
DMI 0.8-16 0.11 0.8 16 120 0.96 16 232
DMI 1-10 0.14 1.0 10 120 1.20 10 145
DMI 1.1-16 0.15 1.1 16 120 1.32 16 232
DMI 1.6-10 0.22 1.6 10 120 1.92 10 145
DMI 3-10 0.42 3.0 10 120 3.50 7 102
DMI 3.6-16 0.50 3.6 16 120 4.32 13 189
DMI 4-8 0.55 4.0 8 120 4.8 8 116
DMI 5-6 0.69 5.0 6 120 6.0 5 72.5
DMI 6-8 0.84 6.0 8 120 7.2 6 87
DMI 9-6 1.24 9.0 6 120 10.8 5.5 80
DMI 14-4 1.92 14.0 4 120 16.8 3 44
DMI 18-4 2.50 18.0 3.5 120 21.6 3 44
1) Depending on the pump type, the maximum dosing flow of pumps with
Plus3 system is reduced by approx. 0.1 to 0.4 l/h.
2) Pmax refers to dosing heads without automatic deaeration.
With automatic deaeration, the Pmax is 1 bar less.

Performance data is measured at maximum pump


counter pressure.
The values in the table above are based on these
conditions:
• water as the dosing liquid
• suction lift of 0.5 m
• fully deaerated dosing head
• maximum stroke length.

Changes in temperature affecting the viscosity of the


pumped media may cause additional friction losses and
require a pump head fitted with spring-loaded valves.
The available pump capacity may be reduced up to
10% when handling fluids at the maximum viscosity.

Turn-down ratio
The turn-down ratio depends on the control version.
Pumps with stroke length adjustment can operate from
10% to 100% of the maximum capacity.
Pumps with pulse control give you even more flexibility.

[email protected] - Tel.+31(0)15-261.09.00 15
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI

Suction lift
Max. suction lift Max. suction lift
Continuous operation1) Start-up2) Max. permissible viscosity at operating
Liquids with a viscosity similar to Non-degassing liquids with a viscosity temperature
Pump water similar to water [mPa s]
[m] [m]
With Plus3
Standard With Plus3 system Standard With Plus3 system Standard HV variant3)
system
DMI 0.3-10 * 1.5 * ** 200 100 500
DMI 0.8-16 6 1.5 1 ** 200 100 500
DMI 1-10 6 1.5 1 ** 200 100 500
DMI 1.1-16 6 1.5 1 ** 200 100 500
DMI 1.6-10 6 1.5 1.5 ** 200 100 500
DMI 3-10 6 1.5 2 ** 200 100 500
DMI 3.6-16 6 1.5 2 ** 200 100 500
DMI 4-8 6 1.5 2.2 ** 200 100 500
DMI 5-6 6 1.5 2.5 - 100 - 500
DMI 6-8 6 1.5 2.8 ** 100 50 500
DMI 9-6 6 1.5 2.8 - 150 - 200
DMI 14-4 6 1.5 2.8 - 150 - 200
DMI 18-4 6 1.5 2.8 - 150 - 200
1) Dosing head and valves wetted (initial start-up)
2) Deaeration valve open
3) Pump head with spring-loaded valves for improved performance when handling viscous liquids
4) The max. permissible viscosities apply to all valve combinations with a spring-loaded valve with an inlet opening pressure of 0.05 bar (valve combination 2
and 3. See type key, page 5.)
* Flooded suction only
** Pumps incorporating the Plus3 system are delivered with special start-up device; consequently, the max. suction lift at start-up is not a problem

Inlet pressure and counter pressure


Max. inlet pressure Min. required counter pressure
Pump Standard Plus3 system Standard Plus3 system
[bar] [bar] [bar] [bar]
DMI 0.3-10 0.2 * 1 1
DMI 0.8-16 0.2 * 1 1
DMI 1-10 0.2 * 1 1
DMI 1.1-16 0.2 * 1 1
DMI 1.6-10 0.2 * 1 1
DMI 3-10 0.2 * 1 1
DMI 3.6-16 0.2 * 1 1
DMI 4-8 0.2 * 1 1
DMI 5-6 0.2 * 1 1
DMI 6-8 0.2 * 1 1
DMI 9-6 0.2 * 1 1
DMI 14-4 0.2 * 1 1
DMI 18-4 0.2 * 1 1
* The pump must not be installed with inlet pressure, as this would cause
overflow.

16 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI

Permissible temperature range of


the pumped media
The pumped media must be liquid. Exceeding the
permissible temperatures may cause malfunction or
damage to the pump.

Permissible temperature range


Dosing head [°C]
material
p < 10 bar p < 16 bar
PVC 0 to 40 0 to 20
Stainless steel,
–10 to 70 –10 to 70
DIN 1.4571*
PP 0 to 40 -
PVDF** –10 to 60 –10 to 20
* Short-term resistance (15 minutes) to 120 °C at a counter pressure of
maximum 2 bar.
** At 70 °C the maximum counter pressure is 3 bar.

Electrical data
DMI 0.8-16
DMI 1.1-16
DMI 0.3-10
DMI 3.6-16
DMI 1.0-10
DMI 5.0-6
Pump DMI 1.6-10
DMI 6.0-8
DMI 3.0-10
DMI 9.0-6
DMI 4.0-8
DMI 14-4
DMI 18-3.5
115 V ±10%, 50/60 Hz
Supply voltage
230 V ±10%, 50/60 Hz
Maximum power consumption [W] 11 22
Motor, synchronous motor
at 115 V 0.096 0.192
with gear reduction Maximum current consumption [A]
at 230 V 0.048 0.096
Enclosure class IP 65

Additional technical data


Dosing flow fluctuation < ±1.5% of full scale value within the control range 10% to 100%
Accuracy1)
Linearity deviation ± 4% of full scale value within the control range 20% to 100%
Weight Standard version 2.9 kg
Sound pressure level Tested according to DIN 45635-01-KL3 ± 45 dB(A)
Permissible ambient temperature 0 to 40 °C
Temperatures
Permissible storage temperature –10 to 40 °C
Humidity Max. relative humidity 92% (non-condensing)
Plus3 system Designed for handling sodium hypochlorite and other degassing fluids
Special features
Spring-loaded valves Valves for viscous liquids
1) The accuracy is based on the following conditions:
- water as the dosing liquid
- fully deaerated dosing head
- standard pump version.

[email protected] - Tel.+31(0)15-261.09.00 17
www.lenntech.com - Fax.+31(0)15-261.62.89
Pump selection DMI

DMI selection (0.3 to 18 l/h)


The example in bold is a DMI 4-8 B-PP/V/G-X-H133B
Max.
Control
capacity Materials of dosing head, gaskets Motor Valve Connection,
Control variant panel Mains plug
and and valve balls voltage type suction/discharge
position
pressure
B = Manual stroke Dosing head version: Control panel position Connection, suction/discharge
length adjust- PP = Polypropylene T = Top-mounted B6 = Pipe, 4/6 mm
ment, PV = PVDF (variants A, AR) 3 = Tube, 4/6 mm
10-100% PVC = Polyvinyl chloride X = No control panel A5 = Tube, 5/8 mm
SS = Stainless steel, (variant B) 4 = Tube, 6/9 mm
A = Pulse control, DIN 1.4401 6 = Tube, 9/12 mm
remote on/off Motor voltage C4 = Tube, 1/8" / 1/4"
PP-P3 = PP + Plus 3 system G = 1 x 230 V, 50/60 Hz R = Tube, 1/4" / 3/8"
AR = Pulse control, H = 1 x 120 V, 50/60 Hz S = Tube, 3/8" / 1/2"
remote on/off, PVC-P3 = PVC + Plus3 system B1 = Tube, 6/12 mm/
alarm output Valve type cementing diameter,12 mm
[l/h] - [bar] Gasket material: 1 = Standard A = Threaded, Rp 1/4, female
E = EPDM 2 = Spring-loaded, A9 = Threaded, 1/2" NPT, male
V = FKM 0.05 bar suction/dis- V = Threaded, 1/4" NPT, female
T = PTFE charge opening pressure B3 = Welding diameter,16 mm
3 = Spring-loaded,
Valve ball material: 0.05 bar suction opening Mains plug
C = Ceramic pressure F = Schuko
G = Glass 0.8 bar discharge opening B = USA and Canada, 120 V
SS = Stainless steel, DIN 1.4401 pressure I = Australia
4 = Spring-loaded, discharge E = Switzerland
side only , X = Without plug
0.8 bar opening pressure
Control
Materials of dosing head, gaskets Motor Valve Connection,
[l/h] - [bar] Control variant panel Mains plug
and valve balls voltage type suction/discharge
position
P < 10 bar, DN 4
PP/E/C
PP/V/C 3 F
1
PP/V/G A5 B
0.3-10 T G 2
PV/T/C B1 I
1.0-10 X H 3
PVC/E/C B6 E
1.6-10 A 4
PVC/V/C C4 X
3.0-10 AR PVC/V/G
4.0-8 B
5.0-6 F
1
6.0-8 B
SS/T/SS T G 2 A9
I
SS/V/SS X H 3 B6
E
4
X
P < 10 bar, DN 8
PP/E/C 4
PP/V/C 6
F
PP/V/G 1 A5
B
PV/T/C T G 2 A9
I
PVC/E/C X H 3 B1
E
9.0-6 A PVC/E/SS 4 B3
X
14-4 AR PVC/V/C R
18-3.5 B PVC/V/G S
F
1
A B
SS/T/SS T G 2
A9 I
SS/V/SS X H 3
V E
4
X
P < 16 bar

PP/E/C
F
PP/V/C 1
A9 B
PP/V/G T G 2
B1 I
PVC/E/C X H 3
C4 E
0,8-16 A PVC/V/C 4
X
1.1-16 AR PVC/V/G
3.6-16 B
F
1
B
SS/T/SS T G 2 A9
I
SS/V/SS X H 3 B6
E
4
X

18 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Pump selection DMI

Max.
Control
capacity Materials of dosing head, gaskets Motor Valve Connection,
Control variant panel Mains plug
and and valve balls voltage type suction/discharge
position
pressure
B = Manual stroke Dosing head version: Control panel position Connection, suction/discharge
length adjust- PP = Polypropylene T = Top-mounted B6 = Pipe, 4/6 mm
ment, PV = PVDF (variants A, AR) 3 = Tube, 4/6 mm
10-100% PVC = Polyvinyl chloride X = No control panel A5 = Tube, 5/8 mm
SS = Stainless steel, (variant B) 4 = Tube, 6/9 mm
A = Pulse control, DIN 1.4401 6 = Tube, 9/12 mm
remote on/off Motor voltage C4 = Tube, 1/8" / 1/4"
PP-P3 = PP + Plus 3 system G = 1 x 230 V, 50/60 Hz R = Tube, 1/4" / 3/8"
AR = Pulse control, H = 1 x 120 V, 50/60 Hz S = Tube, 3/8" / 1/2"
remote on/off, PVC-P3 = PVC + Plus3 system B1 = Tube, 6/12 mm/
alarm output Valve type cementing diameter,12 mm
[l/h] - [bar] Gasket material: 1 = Standard A = Threaded, Rp 1/4, female
E = EPDM 2 = Spring-loaded, A9 = Threaded, 1/2" NPT, male
V = FKM 0.05 bar suction/dis- V = Threaded, 1/4" NPT, female
T = PTFE charge opening pressure B3 = Welding diameter,16 mm
3 = Spring-loaded,
Valve ball material: 0.05 bar suction opening Mains plug
C = Ceramic pressure F = Schuko
G = Glass 0.8 bar discharge opening B = USA and Canada, 120 V
SS = Stainless steel, DIN 1.4401 pressure I = Australia
4 = Spring-loaded, discharge E = Switzerland
side only , X = Without plug
0.8 bar opening pressure
Control
Materials of dosing head, gaskets Motor Valve Connection,
[l/h] - [bar] Control variant panel Mains plug
and valve balls voltage type suction/discharge
position
P < 10 bar, Plus3
0.3-10
F
1.0-10 PP-P3/E/C 1 3
A B
1.6-10 PP-P3/V/C T G 2 A5
AR I
3.0-10 PVC-P3/E/C X H 3 B1
B E
4.0-8 PVC-P3/V/C 4 C4
X
6.0-8
P < 16 bar, Plus3
F
PP-P3/E/C 1
0,8-16 A B
PP-P3/V/C T G 2 B1
1.1-16 AR I
PVC-P3/E/C X H 3 C4
3.6-16 B E
PVC-P3/V/C 4
X

[email protected] - Tel.+31(0)15-261.09.00 19
www.lenntech.com - Fax.+31(0)15-261.62.89
Pumped media DMI

List of pumped media The list should, however, be applied with some caution
as factors such as purity, temperature, abrasive parti-
This table is intended as a general guide only on the
cles, etc. may affect the chemical resistance of a spe-
resistance of materials (at room temperature) to the
cific material.
liquids listed. The table cannot replace actual testing of
the pumped media and pump materials under specific Note: Some of the liquids in this table may be toxic, cor-
working conditions. rosive or hazardous. Be careful when handling the liq-
uids.

Materials
Pumped medium (68°F)
Pump housing Gasket Ball

Concentration %

Stainless steel,

Cen tellen C
DIN 1.4401
Designation Chemical formula

Ceramic
EPDM

Glass
PVDF

PTFE
FKM
PVC
PP

25 z z z z – z z z z z
Acetic acid CH3COOH 60 z z z z –  z  z z
85 z z z – – – z  z z
Aluminium chloride AlCl3 40 z z – z z z z z z z
Aluminium sulphate Al2(SO4)3 60 z z z z z z z z z –
Ammonia, aqueous NH4OH 28 z z z z – z z  z –
Calcium hydroxide7 Ca(OH)2 z z z z z z z z z z
Calcium hypochlorite Ca(OCl)2 20  z – z z z z z z z
10 z z z z z z z z z z
30 – z – z z  z  z z
Chromic acid5 H2CrO4
40 – z – z z – z  z z
50 – z – z z – z  z z
Copper sulphate CuSO4 30 z z z z z z z z z z
Ferric chloride3 FeCl3 100 z z – z z z z z z z
Ferric sulphate 3 Fe2(SO4)3 100 z z z z z z z z z z
Ferrous chloride FeCl2 100 z z – z z z z z z z
Ferrous sulphate FeSO4 50 z z z z z z z z z z
<25 z z – z  z z z z z
Hydrochloric acid HCl
25 to 37 z z – z – z z  z z
Hydrogen peroxide H2O2 30 z z z z z z z z z z
10 z z z z z z z z z z
30 z z z z z z z – z z
Nitric acid HNO3
40  z z z z z z – z z
70 – z z – z – z – z z
Peracetic acid CH3COOOH 5 z z – z – z z z z z
Potassium hydroxide KOH 50 z – z z – z z  z –
Potassium permanganate KMnO4 10 z z z z – z z z z z
Sodium chlorate NaClO3 30 z z z z  z z z z
Sodium chloride NaCl 30 z z – z z z z z z z
Sodium chlorite NaClO2 20 z  – – z z z z z z
20 z  z z – z z  z –
Sodium hydroxide NaOH 30 z – z z – z z  z –
50 z – z z – z z  z –
Sodium hypochlorite NaOCl 20  z – z z z z z z z
Sodium sulphide Na2S 30 z z z z z z z z z –
Sodium sulphite6 Na2SO3 20 z z z z z z z z z –
Sulphurous acid H2SO3 6 z z z z z z z z z 
<80 z z –  z  z  z 
Sulphuric acid4 H2SO4
80 to 98  z – – z – z z z –
z Resistant. 3 Risk of crystallisation.
 Limited resistance. 4 Reacts violently with water and generates much heat.
Pump should be absolutely dry before dosing sulphuric acid.)
– Not resistant. 5 Must be fluoride-free when glass balls are used.
6 In neutral solutions.
7 Saturated solution 0.1%.

20 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Further product DMI

documentation

WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.

Catalogue

This section is based on fields of application and pump types,


and contains
• technical data
• curves (QH, Eta, P1, P2, etc) which can be adapted to the den-
sity and viscosity of the pumped medium and show the number
of pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.

Literature

In this section you can access all the latest documents of a given
pump, such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures.

Service

This section contains an easy-to-use interactive service cata-


logue. Here you can find and identify service parts of both exist-
ing and discontinued Grundfos pumps.
Furthermore, this section contains service videos showing you
how to replace service parts.

[email protected] - Tel.+31(0)15-261.09.00 21
www.lenntech.com - Fax.+31(0)15-261.62.89
Further product DMI

documentation

Sizing 0 1

This section is based on different fields of application and instal-


lation examples, and gives easy step-by-step instructions in how
to
• select the most suitable and efficient pump for your installation
• carry out advanced calculations based on energy consumption,
payback periods, load profiles, life cycle costs, etc.
• analyse your selected pump via the built-in life cycle cost tool
• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing


replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grund-


fos pumps with the one you have installed on your site. When
you have specified the installed pump, the guide will suggest a
number of Grundfos pumps which can improve both comfort and
efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and


3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.

3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided Prod-
uct Selection program containing detailed information
on more than 185,000 Grundfos products in more than
20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet con-
nection is available.
WinCAPS is available on CD-ROM and updated once a
year.

Fig. 18 WinCAPS CD-ROM

22 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
DMI

[email protected] - Tel.+31(0)15-261.09.00 23
www.lenntech.com - Fax.+31(0)15-261.62.89
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

96699722 0307
GB
Subject to alterations.

Lenntech
[email protected]
www.lenntech.com