Grundfos DMI Dosing L
Grundfos DMI Dosing L
[email protected]
www.lenntech.com
DMI
Dosing
Contents DMI
Performance range
DMI, 50 Hz 4
DMI, 60 Hz 5
Identification
Type key 6
Functions
Control variants 7
Options 7
Functions 7
Capacity control 8
Construction
General description 10
DMI with manual deaeration 10
DMI with Plus3 system 11
Functional principle of the Plus3 system 12
Spring-loaded valves 12
Technical data
Dimensions 13
Performance data 15
Suction lift 16
Inlet pressure and counter pressure 16
Permissible temperature range of the pumped media 17
Electrical data 17
Additional technical data 17
Pump selection
DMI selection (0.3 to 18 l/h) 18
Pumped media
List of pumped media 20
2 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Features and benefits DMI
GrA3475 / GrA3482
• stroke-frequency control
• access to check functions and venting
• optional memory function.
Choose between control options
Fig. 1 DMI B Fig. 2 DMI A The DMI A (AR) series can be set to either proportional
control or manual dosing by pressing a key. Pulse
Variations on the synchronous-motor theme control mode allows proportional control according to
The Grundfos DMI range of dosing pumps comprises external contact signals from a flowmeter or other
several variants for general or specific dosing pur- device.
poses. Dosing heads and valves are available in differ-
ent materials to suit a wide range of general water Examples of applications
treatment and industrial applications. • industrial and municipal water treatment •
water treatment in cooling towers •
Whichever model you choose, you get a sturdy, cost-
efficient pump based on a well-proven synchronous- industrial cleaning •
motor design. The DMI range can dose rates from 0.3 Cleaning-In-Place (CIP) and disinfection
to 18 l/h and pressures up to 16 bar. (dairies,
food and beverage industries, etc.)
Silent operation
• paper production/finishing
Regardless of model, the DMI pump is among the most
silent of its type available on the market today. It keeps • chemical industry
its noise levels down to just 45 dB(A). • chemigation
• galvanic and surface treatment
Flexible installation
• plating
The Grundfos DMI is suitable for both horizontal and
vertical installation. If installed horizontally, the control • water treatment in swimming pools
elements are located on the top of the unit for easy • semiconductor industry.
access.
[email protected] - Tel.+31(0)15-261.09.00 3
www.lenntech.com - Fax.+31(0)15-261.62.89
Performance range DMI
DMI, 50 Hz
p
[bar]
DMI
16 50 Hz
14
12
10
1 2 3 4 5 6 7 8 9 10 11 12 13
2
Pos. Pump
1 DMI 0.3-10
2 DMI 0.8-16
3 DMI 1.0-10
4 DMI 1.1-16
5 DMI 1.6-10
6 DMI 3.0-10
7 DMI 3.6-16
8 DMI 4.0-8
9 DMI 5.0-6
10 DMI 6.0-8
11 DMI 9.0-6
12 DMI 14-4
13 DMI 18-3.5
4 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Performance range DMI
DMI, 60 Hz
p
[bar] DMI
16 60 Hz
14
12
10
1 2 3 4 5 6 7 8 9 10 11 12 13
2
Pos. Pump
1 DMI 0.3-10
2 DMI 0.8-16
3 DMI 1.0-10
4 DMI 1.1-16
5 DMI 1.6-10
6 DMI 3.0-10
7 DMI 3.6-16
8 DMI 4.0-8
9 DMI 5.0-6
10 DMI 6.0-8
11 DMI 9.0-6
12 DMI 14-4
13 DMI 18-3.5
[email protected] - Tel.+31(0)15-261.09.00 5
www.lenntech.com - Fax.+31(0)15-261.62.89
Identification DMI
Type key
DMI X No plug
F EU (Schuko)
Maximum flow [l/h]
B USA, Canada
I Australia, New Zealand, Taiwan
Maximum pressure [bar]
E Switzerland
E EPDM 1 Standard
V FKM Spring-loaded
2 0.05 bar suction opening pressure;
T PTFE 0.05 bar discharge opening pressure
Spring-loaded
Valve ball material 3 0.05 bar suction opening pressure;
0.8 bar discharge opening pressure
C Ceramic Spring-loaded, discharge only
4
G Glass 0.8 bar opening pressure
T PTFE
Supply voltage
SS Stainless steel, DIN 1.4401
G 1 x 230 V, 50/60 Hz
Control panel position
H 1 x 120 V, 50/60 Hz
T Top-mounted
X No control panel
6 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Functions DMI
GrA3475 / GrA3482
Options
Pump Plus3 system*
DMI 0.3-10 z
DMI 0.8-16 z
DMI 1.0-10 z
DMI 1.1-16 z
DMI 1.6-10 z
DMI 3.0-10 z
DMI 3.6-10 z
DMI 4.0-8 z
DMI 5.0-6
DMI 6.0-8 z
DMI 9.0-6
DMI 14-4
DMI 18-3.5
* See page 11.
GrA3483
[email protected] - Tel.+31(0)15-261.09.00 7
www.lenntech.com - Fax.+31(0)15-261.62.89
Functions DMI
Capacity control
The capacity can be controlled in three ways:
Manual
• by adjusting the stroke length 1:n 1:16 1:32 Contact
Mode 1:8 90 100 %
• by stroke-frequency control 80
1:4
70
• by external pulse control.
60 0
1:2 32:1
50 10
1:1 40 20 16:1
30
n:1 2:1 8:1
4:1
Q
[gph]
TM03 4643 0506
Fig. 9 Capacity control by adjusting the stroke Fig. 10 Relation between stroke length (I)
length and capacity (Q)
Stroke
Discharge
length Duration
100%
Suction
Discharge
Duration
50%
Suction
TM03 2074 3505
Discharge
Duration
10%
Suction
8 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Functions DMI
Stroke-frequency control
The suction and discharge stroke speeds are constant,
while the stroke frequency varies according to the fre-
quency set.
Capacity
setting Discharge
Duration
100%
Suction
Discharge
Duration
50%
Suction
Discharge
[email protected] - Tel.+31(0)15-261.09.00 9
www.lenntech.com - Fax.+31(0)15-261.62.89
Construction DMI
General description
The DMI pump is powered by an overload-protected
synchronous motor.
The DMI is available with several options on the pump
head:
• manual deaeration (standard)
• Plus3 system.
As an option, the pump can also be equipped with
spring-loaded valves for viscous liquids.
Legend
Pos. Component
1a Suction valve
1b Discharge valve
2a Dosing head with manual deaeration
3 Connection for deaeration line
4 Manual bleed/deaeration valve
10 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Construction DMI
Legend
Pos. Component
1a Suction valve
1b Discharge valve
2c Dosing head with Plus 3 system
3 Connection for deaeration line
4 Manual deaeration valve
5 Suction line from tank
6 Line from calibration tube (pos. 8) to dosing head (pos. 2c)
7 Isolating valve at calibration tube (pos. 8)
8 Calibration tube
9 Priming/deaeration chamber
10 Connection for overflow line (pos. 11)
11 Overflow line to the tank (PVC tube 8/11 mm)
12 Deaeration line to the tank
13 Dosing line (discharge line)
14 Cover
15 Adhesive label
16 Deaeration hole
[email protected] - Tel.+31(0)15-261.09.00 11
www.lenntech.com - Fax.+31(0)15-261.62.89
Construction DMI
2
7 TM03 4500 2206
1
8 4
Legend
Pos. Component
1 Inlet from tank
2 Conveying diaphragm
3 Priming/deaeration chamber
4 Dosing diaphragm
5 Discharge to the process line
6 Deaeration bypass
7 Calibration tube
8 Calibration valve
12 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI
Dimensions
DMI
20
10
30
0
40
50
60
100%
70
90
80
Dimensions
[email protected] - Tel.+31(0)15-261.09.00 13
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI
Dimensions
A1 B1 C1 D1 E1
Pump
[mm] [mm] [mm] [mm]
DMI 0.3-10 261 25.2 251 197.5 G 3/8
DMI 0.8-16 261 25.2 251 197.5 G 3/8
DMI 1-10 261 25.2 251 197.5 G 3/8
DMI 1.1-16 261 25.2 251 197.5 G 3/8
DMI 1.6-10 261 25.2 251 197.5 G 3/8
DMI 3-10 261 25.2 251 197.5 G 3/8
DMI 3.6-16 261 25.2 251 197.5 G 3/8
DMI 4-8 261 25.2 251 197.5 G 3/8
DMI 5-6 - - - - -
DMI 6-8 261 25.2 251 197.5 G 3/8
DMI 9-6 - - - - -
DMI 14-4 - - - - -
DMI 18-4 - - - - -
14 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI
Performance data
50 Hz 60 Hz
Vstroke
Pump Capacity 1)
Pmax 2) Max. stroke rate Capacity 1)
Pmax2) Max. stroke rate
[cm3]
[l/h] [bar] [strokes/min] [l/h] [bar] [strokes/min]
DMI 0.3-10 0.04 0.3 10 120 0.36 10 145
DMI 0.8-16 0.11 0.8 16 120 0.96 16 232
DMI 1-10 0.14 1.0 10 120 1.20 10 145
DMI 1.1-16 0.15 1.1 16 120 1.32 16 232
DMI 1.6-10 0.22 1.6 10 120 1.92 10 145
DMI 3-10 0.42 3.0 10 120 3.50 7 102
DMI 3.6-16 0.50 3.6 16 120 4.32 13 189
DMI 4-8 0.55 4.0 8 120 4.8 8 116
DMI 5-6 0.69 5.0 6 120 6.0 5 72.5
DMI 6-8 0.84 6.0 8 120 7.2 6 87
DMI 9-6 1.24 9.0 6 120 10.8 5.5 80
DMI 14-4 1.92 14.0 4 120 16.8 3 44
DMI 18-4 2.50 18.0 3.5 120 21.6 3 44
1) Depending on the pump type, the maximum dosing flow of pumps with
Plus3 system is reduced by approx. 0.1 to 0.4 l/h.
2) Pmax refers to dosing heads without automatic deaeration.
With automatic deaeration, the Pmax is 1 bar less.
Turn-down ratio
The turn-down ratio depends on the control version.
Pumps with stroke length adjustment can operate from
10% to 100% of the maximum capacity.
Pumps with pulse control give you even more flexibility.
[email protected] - Tel.+31(0)15-261.09.00 15
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI
Suction lift
Max. suction lift Max. suction lift
Continuous operation1) Start-up2) Max. permissible viscosity at operating
Liquids with a viscosity similar to Non-degassing liquids with a viscosity temperature
Pump water similar to water [mPa s]
[m] [m]
With Plus3
Standard With Plus3 system Standard With Plus3 system Standard HV variant3)
system
DMI 0.3-10 * 1.5 * ** 200 100 500
DMI 0.8-16 6 1.5 1 ** 200 100 500
DMI 1-10 6 1.5 1 ** 200 100 500
DMI 1.1-16 6 1.5 1 ** 200 100 500
DMI 1.6-10 6 1.5 1.5 ** 200 100 500
DMI 3-10 6 1.5 2 ** 200 100 500
DMI 3.6-16 6 1.5 2 ** 200 100 500
DMI 4-8 6 1.5 2.2 ** 200 100 500
DMI 5-6 6 1.5 2.5 - 100 - 500
DMI 6-8 6 1.5 2.8 ** 100 50 500
DMI 9-6 6 1.5 2.8 - 150 - 200
DMI 14-4 6 1.5 2.8 - 150 - 200
DMI 18-4 6 1.5 2.8 - 150 - 200
1) Dosing head and valves wetted (initial start-up)
2) Deaeration valve open
3) Pump head with spring-loaded valves for improved performance when handling viscous liquids
4) The max. permissible viscosities apply to all valve combinations with a spring-loaded valve with an inlet opening pressure of 0.05 bar (valve combination 2
and 3. See type key, page 5.)
* Flooded suction only
** Pumps incorporating the Plus3 system are delivered with special start-up device; consequently, the max. suction lift at start-up is not a problem
16 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Technical data DMI
Electrical data
DMI 0.8-16
DMI 1.1-16
DMI 0.3-10
DMI 3.6-16
DMI 1.0-10
DMI 5.0-6
Pump DMI 1.6-10
DMI 6.0-8
DMI 3.0-10
DMI 9.0-6
DMI 4.0-8
DMI 14-4
DMI 18-3.5
115 V ±10%, 50/60 Hz
Supply voltage
230 V ±10%, 50/60 Hz
Maximum power consumption [W] 11 22
Motor, synchronous motor
at 115 V 0.096 0.192
with gear reduction Maximum current consumption [A]
at 230 V 0.048 0.096
Enclosure class IP 65
[email protected] - Tel.+31(0)15-261.09.00 17
www.lenntech.com - Fax.+31(0)15-261.62.89
Pump selection DMI
PP/E/C
F
PP/V/C 1
A9 B
PP/V/G T G 2
B1 I
PVC/E/C X H 3
C4 E
0,8-16 A PVC/V/C 4
X
1.1-16 AR PVC/V/G
3.6-16 B
F
1
B
SS/T/SS T G 2 A9
I
SS/V/SS X H 3 B6
E
4
X
18 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Pump selection DMI
Max.
Control
capacity Materials of dosing head, gaskets Motor Valve Connection,
Control variant panel Mains plug
and and valve balls voltage type suction/discharge
position
pressure
B = Manual stroke Dosing head version: Control panel position Connection, suction/discharge
length adjust- PP = Polypropylene T = Top-mounted B6 = Pipe, 4/6 mm
ment, PV = PVDF (variants A, AR) 3 = Tube, 4/6 mm
10-100% PVC = Polyvinyl chloride X = No control panel A5 = Tube, 5/8 mm
SS = Stainless steel, (variant B) 4 = Tube, 6/9 mm
A = Pulse control, DIN 1.4401 6 = Tube, 9/12 mm
remote on/off Motor voltage C4 = Tube, 1/8" / 1/4"
PP-P3 = PP + Plus 3 system G = 1 x 230 V, 50/60 Hz R = Tube, 1/4" / 3/8"
AR = Pulse control, H = 1 x 120 V, 50/60 Hz S = Tube, 3/8" / 1/2"
remote on/off, PVC-P3 = PVC + Plus3 system B1 = Tube, 6/12 mm/
alarm output Valve type cementing diameter,12 mm
[l/h] - [bar] Gasket material: 1 = Standard A = Threaded, Rp 1/4, female
E = EPDM 2 = Spring-loaded, A9 = Threaded, 1/2" NPT, male
V = FKM 0.05 bar suction/dis- V = Threaded, 1/4" NPT, female
T = PTFE charge opening pressure B3 = Welding diameter,16 mm
3 = Spring-loaded,
Valve ball material: 0.05 bar suction opening Mains plug
C = Ceramic pressure F = Schuko
G = Glass 0.8 bar discharge opening B = USA and Canada, 120 V
SS = Stainless steel, DIN 1.4401 pressure I = Australia
4 = Spring-loaded, discharge E = Switzerland
side only , X = Without plug
0.8 bar opening pressure
Control
Materials of dosing head, gaskets Motor Valve Connection,
[l/h] - [bar] Control variant panel Mains plug
and valve balls voltage type suction/discharge
position
P < 10 bar, Plus3
0.3-10
F
1.0-10 PP-P3/E/C 1 3
A B
1.6-10 PP-P3/V/C T G 2 A5
AR I
3.0-10 PVC-P3/E/C X H 3 B1
B E
4.0-8 PVC-P3/V/C 4 C4
X
6.0-8
P < 16 bar, Plus3
F
PP-P3/E/C 1
0,8-16 A B
PP-P3/V/C T G 2 B1
1.1-16 AR I
PVC-P3/E/C X H 3 C4
3.6-16 B E
PVC-P3/V/C 4
X
[email protected] - Tel.+31(0)15-261.09.00 19
www.lenntech.com - Fax.+31(0)15-261.62.89
Pumped media DMI
List of pumped media The list should, however, be applied with some caution
as factors such as purity, temperature, abrasive parti-
This table is intended as a general guide only on the
cles, etc. may affect the chemical resistance of a spe-
resistance of materials (at room temperature) to the
cific material.
liquids listed. The table cannot replace actual testing of
the pumped media and pump materials under specific Note: Some of the liquids in this table may be toxic, cor-
working conditions. rosive or hazardous. Be careful when handling the liq-
uids.
Materials
Pumped medium (68°F)
Pump housing Gasket Ball
Concentration %
Stainless steel,
Cen tellen C
DIN 1.4401
Designation Chemical formula
Ceramic
EPDM
Glass
PVDF
PTFE
FKM
PVC
PP
25 z z z z – z z z z z
Acetic acid CH3COOH 60 z z z z – z z z
85 z z z – – – z z z
Aluminium chloride AlCl3 40 z z – z z z z z z z
Aluminium sulphate Al2(SO4)3 60 z z z z z z z z z –
Ammonia, aqueous NH4OH 28 z z z z – z z z –
Calcium hydroxide7 Ca(OH)2 z z z z z z z z z z
Calcium hypochlorite Ca(OCl)2 20 z – z z z z z z z
10 z z z z z z z z z z
30 – z – z z z z z
Chromic acid5 H2CrO4
40 – z – z z – z z z
50 – z – z z – z z z
Copper sulphate CuSO4 30 z z z z z z z z z z
Ferric chloride3 FeCl3 100 z z – z z z z z z z
Ferric sulphate 3 Fe2(SO4)3 100 z z z z z z z z z z
Ferrous chloride FeCl2 100 z z – z z z z z z z
Ferrous sulphate FeSO4 50 z z z z z z z z z z
<25 z z – z z z z z z
Hydrochloric acid HCl
25 to 37 z z – z – z z z z
Hydrogen peroxide H2O2 30 z z z z z z z z z z
10 z z z z z z z z z z
30 z z z z z z z – z z
Nitric acid HNO3
40 z z z z z z – z z
70 – z z – z – z – z z
Peracetic acid CH3COOOH 5 z z – z – z z z z z
Potassium hydroxide KOH 50 z – z z – z z z –
Potassium permanganate KMnO4 10 z z z z – z z z z z
Sodium chlorate NaClO3 30 z z z z z z z z
Sodium chloride NaCl 30 z z – z z z z z z z
Sodium chlorite NaClO2 20 z – – z z z z z z
20 z z z – z z z –
Sodium hydroxide NaOH 30 z – z z – z z z –
50 z – z z – z z z –
Sodium hypochlorite NaOCl 20 z – z z z z z z z
Sodium sulphide Na2S 30 z z z z z z z z z –
Sodium sulphite6 Na2SO3 20 z z z z z z z z z –
Sulphurous acid H2SO3 6 z z z z z z z z z
<80 z z – z z z
Sulphuric acid4 H2SO4
80 to 98 z – – z – z z z –
z Resistant. 3 Risk of crystallisation.
Limited resistance. 4 Reacts violently with water and generates much heat.
Pump should be absolutely dry before dosing sulphuric acid.)
– Not resistant. 5 Must be fluoride-free when glass balls are used.
6 In neutral solutions.
7 Saturated solution 0.1%.
20 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
Further product DMI
documentation
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.
Catalogue
Literature
In this section you can access all the latest documents of a given
pump, such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures.
Service
[email protected] - Tel.+31(0)15-261.09.00 21
www.lenntech.com - Fax.+31(0)15-261.62.89
Further product DMI
documentation
Sizing 0 1
Replacement
CAD drawings
2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.
3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided Prod-
uct Selection program containing detailed information
on more than 185,000 Grundfos products in more than
20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet con-
nection is available.
WinCAPS is available on CD-ROM and updated once a
year.
22 [email protected] - Tel.+31(0)15-261.09.00
www.lenntech.com - Fax.+31(0)15-261.62.89
DMI
[email protected] - Tel.+31(0)15-261.09.00 23
www.lenntech.com - Fax.+31(0)15-261.62.89
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
96699722 0307
GB
Subject to alterations.
Lenntech
[email protected]
www.lenntech.com