When hanging steel pipe, place hangers no A drop tube in a water heater causes the
further apart than incoming cold water to mix with
- 12 ft (3.6m) - Stored hot water in the bottom of the tank
The drain cock with a hose connection at the
Lead pipe and tubing must be supported bottom of a water heater is primarily used to
vertically every? - Flush sediments out of the heater
- 4 ft. (1.2m)
*Limit stops* shall be provided on such valves
Support all piping at intervals of not more than and shall be adjusted to deliver hot water with a
___ at end of branches & change of direction or maximum temperature of *48.88C*
elevation
Potable Water Make Up Connections to Steam
- 4 ft.
or Hot Water Boilers shall be provided with a
Support or anchorage of piping shall not exceed listed *backflow protection assembly*
an interval of
CPVC water pipe & tubing
- 4 ft.
- Water pressure pipes shall be for hot & cold
Copper tubing water distribution systems
- It shall be supported at each storey or at a
CPVC water pipe maybe used for hot and cold
maximum intervals of 3m on center.
water distribution systems
- shall be installed without joints where
- within a building
possible: True
Brass or copper shall not be used for urinal
Indirect water heater
tailpiece or trap
- A common heat source for indirect water
- TRUE
heater: steam
Plastic Pipe
Approved provisions shall be made for
- shall be supported every 1m interval
expansions of __.
- hot water pipings
How much air pressure should you use for
Expansion loop
testing piping for leaks
- used in hot water supply piping system
- 50 psi
- requires *Expansion joints* for installing long,
straight horizontal or vertical runs of copper
What is the proper length of time and velocity
domestic hot water piping
for flushing a main?
- except for venting
- 30 minutes / 2.5 fps
Copper pipes
When specifications are not available, install the - pipe that is remarkable for hot water lure
urinal so the lip height is? installation
- 20 to 25 in. above the finished floor line
The anode rod is installed in the top of water
heaters to prevent corrosion
- inside the tank
Water Holding Tank (HWT)
A _____ is a artificial rod installed in a water
The distance between a water heater and the heater to protect tank from corrosion
union on the water lines shall not be more than - anode rod
- 12"
For listed non-storage instantaneous heaters
What is the distance from the top of water having an inside diameter of not more than
heater to relief valve? - 76mm
- 6 in. (150mm)
What is the normal working pressure of a gas
What is the MAXIMUM distance away from a water heater
water heater you can install a shutoff valve? - 125 psi
- 5 ft. (1.5m)
TP valve
Every passageway to an attic water heater shall - the safety valve on a water heater
have a solid continuous flooring not less than
Inspection hole
- 24 in.
- Cold water supply is delivered into the hot
water by means of a boiler tube; this tube has a
hole within 6 inches from the top of the tank, - bathtub
the purpose of which is to serve as - Floor drain
- Bar sink, drinking fountain, lavatory public use
Cold water: 85 F
- Bidet, bathtub (with or without shower over),
Hot Water: 120 F
laundry tub or clothes washer (each pair of
Shower valve: 115 F
faucets), shower (each head), sink or
dishwasher private use
Screwed steel pipe 2 1/2 in. diameter should
2.5
have this # of threads for effective joining
-8 - Water closet (economical flush) private use
3
Fixture Unit - Slop sink: 3
- The quantity of water required to be supplied - Urinal (flush tank): 3
to every plumbing fixture shall be represented - Combination fixture: 3
by Fixture Units: TRUE - Water closet (flush tank & flushometer tank),
- Term with reference to the load producing hose bibb or sill cock (std. type) private use: 3
effect on the plumbing system for different kind
of plumbing fixtures 4
- A flow of waste used for sizing plumbing jobs - Bidet, bathtub (with or without shower over),
in a plumbing system, equal to 28.3 LPM laundry tub or clothes washer (each pair of
(1cu.ft/min) faucets), shower (each head), sink or
dishwasher public use: 4
5
Plumbing blueprints and floor plans - Water closet (economical flush) public use: 5
- used to find the location of fixtures in a - Urinal or Urinal (stall & wall): 5
building - Water closet (flush tank & flushometer tank),
hose bibb or sill cock (std. type) public use: 5
What is a bridge in a plumbing system?
- meeting point of the two subsystems 6
- Mobile Home (each), temporary facilities: 6
How many drainage fixture units (DFUs) are 10
allowed on a 2" (51mm) horizontal drain line? - Urinal (pedestal or similar type): 10
-6
Fixtures outlet shall not be connected to the
What is the fixture unit of 18 storey dormitory horizontal drainage
building with 6 bathroom group on every floor - within 2.4m of any vertical to horizontal
with class 2? change
- 756
On short horizontal drainage pipe installed at a
slope of
Fixture Unit (FU) value of - 72 degrees
1 Fixtures shall be set level and in proper
alignment with reference to
- Lawn Sprinkler (std. type, each head): 1
- adjacent walls
- Bar sink, drinking fountain, lavatory private
On short horizontal drainage pipe installed at a
use: 1
slope of not less from the vertical line
- for every 15 sq. foot of roof drain: 1 - 1/5 bend
1.5
Mobile Home Park Sewer
- Residential sink
- A part of the horizontal piping of sanitary
2 drainage system which measures 0.6 meter
downstream from the last mobile home site and
- Laundry tub conveys sewage to a public sewer, private sewer,
- Shower bath individual sewage disposal system or other
- Sink (hotel or public) points of disposal.