URS PRODUCTS AND TESTING PVT LTD ULR No.

: ULR-
TC646824000001461F

DOC No. : F-3, Sector - 6, Noida, Gautam Buddha Nagar, Uttar


Telephone : +91 9871062220 Pradesh, India - 201301
FAX : -
E-Mail : [email protected]
BO Code : NA

Test REPORT AS PER : IS 15885 : Part 2 : Sec 13


(2012)

QR Code/Barcode : 180525CRS

REPORT NO : SC24EPI01632_1 DATE : 29 Feb, 2024

PART A. PARTICULARS OF SAMPLE SUBMITTED

a) Customer Name & Address : Uniglobus Electricals & Electronics Private


Limited
C/O POLYCAB UNIT 4, NURPURA, HALOL
VADODARA ROAD, HALOL, PANCH MAHALS,
PIN-389350, GUJARAT, NA, GUJARAT, India -
389350
b) Nature of sample : -
c) Grade/Variety/Type/Class Size etc : NA
d) Declare values, if any : -
e) Batch No. & Date of Manufacture : /
f) Quantity : 1
g) Date of Receipt : 07 Feb, 2024
h) BIS Seal : Verified by Sample Cell
i) IO's Signature : Verified by Sample Cell
j) Any other Information / Expiry Date, If any : /
k) Date of Commencement of Testing : 07 Feb, 2024
l) Date of Completion of Testing : 29 Feb, 2024
m) Section Code : 24E5F40N
n) Section Report No. : 24E5F40N_1
o) Report Type : New
p) Reference Report No. :
q) Remarks : OK

MONIKA VERMA
OIC SAMPLE CELL
(Authorized Signatory)
Authorized on: 29 Feb, 2024 12:08 PM

1. URS PRODUCTS AND TESTING PVT LTD

This is a Computer Generated Report.

Page 1 of 52
Section Report No. : 24E5F40N_1 IS 15885 : Part 2 : Sec 13 (2012)

PART B. SUPPLEMENTARY INFORMATION

1. Reference to sampling procedure, wherever applicable. Not Applicable


2. Supporting documents for the measurements taken and results derived like graphs, Yes
table sketches and or photographs as appropriate to test report, if any.
3. Deviation from the test methods as prescribed in relevant ISS/Work instruction, if any. Not Applicable
3. NABL Report required ? Yes

Himanshu Sharma
OIC Electrical
(Authorized Signatory)
Authorized on: 29 Feb, 2024 12:06 PM

This is a Computer Generated Report.

Page 2 of 52
Section Report No. : 24E5F40N_1 IS 15885 : Part 2 : Sec 13 (2012)

PART C. TEST RESULT

S.No. Clause No Parameter - Test Description Min Max Unit Result/


Table No. Method of test Limit Limit Observation
Sl. No

1 20 Resistance to - - - - Satisfactory (Refer to


corrosion attached report)

2 19 Resistance to heat, - - - - Not Applicable (Refer


fire and tracking to attached report)

3 18 Screws, current - - - - Satisfactory (Refer to


carrying parts and attached report)
connections

4 17 Creepage distance - - - - Not Applicable (Refer


and clearances to attached report)

5 16 Construction - - - - Satisfactory (Refer to


attached report)

6 15 Transformer heating - - - - Not Applicable (Refer


to attached report)

7 14 Fault conditions - - - - Satisfactory (Refer to


attached report)

8 13 Thermal endurance - - - - Not Applicable (Refer


test for winding of to attached report)
ballasts

9 12 Electric Strength - - - - Satisfactory (Refer to


attached report)

10 11 MOISTURE - - - - Satisfactory (Refer to


RESISTANCE attached report)

11 10 PROVISION FOR Class II construction, - - - Satisfactory (Refer to


EARTHING No provision for attached report)
earthing.

12 9 Terminals No such screw - - - Not Applicable (Refer


terminal used. No to attached report)
such screw less
terminal used.

13 8 Protection against Controlgear - - - Satisfactory (Refer to


accidental contact protected against attached report)
with live parts accidental contact
with live parts

14 7 Marking Rubbing 15 s water, - - - Satisfactory (Refer to


15 s petroleum; attached report)
marking legible

Himanshu Sharma
OIC Electrical
(Authorized Signatory)
Authorized on: 29 Feb, 2024 12:06 PM

This is a Computer Generated Report.

Page 3 of 52
Section Report No. : 24E5F40N_1 IS 15885 : Part 2 : Sec 13 (2012)

PART D. REMARKS

ok

Himanshu Sharma
OIC Electrical
(Authorized Signatory)
Authorized on: 29 Feb, 2024 12:06 PM

This is a Computer Generated Report.

Page 4 of 52
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

SUMMARY OF TEST REPORT

TEST REPORT NO:SC24EPI01632_1 DATED:29/02/2024


(Number of pages in test report: Page no. 01 to 46) URS Ref. : URS/LAB/01/RID
/23-24/3781

TEST FORMAT AS PER IS 15885 (Part 2/Sec 13):2012+A1:2015

1. Name of Manufacturer:Uniglobus Electricals & Electronics Private Limited


2. Product:Constant Current LED Driver ( AC Supplied Electronic Controlgear for LED
Modules)
3. Model(s):UGM320U090X7
4. Model differences provided (if applicable):No
5. Model differences verified as per MEITY Guidelines for series formulation:No
6. Test Results:See below
PART A: GENERAL

S No. TEST REQUIREMENT CLAUSE VERDICT


1. Marking 7(7) P
2. Protection against accidental contact with live parts 8(10) P
3. Terminals 9(8) N/A
4. Provisions for protective earthing 10(9) P
5. Moisture resistance 11(11) P
6. Electric strength 12(12) P
7. Thermal endurance test for windings of ballasts 13(13) N/A
8. Fault conditions 14(14) P
9. Transformer heating 15(-) N/A
10. Construction 16(15) P
11. Creepage distance and clearances 17(16) N/A
12. Screws, Current-carrying parts and connections 18(17) P
13. Resistance to heat, fire and tracking 19(18) N/A
14. Resistance to corrosion 20(19) P

Page 1 ULR- TC646824000001461F


Page 5 of 52 Discipline-Electrical Testing Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

General Information:
The conformity certificates of critical components are vertified to ensure complete testing of
apparatus under test and details regarding harmonized IEC standards (where IEC standards
are not available) are also provided in the list of critical component.

Remark:
All test have been performed on Model: UGM320U090X7

CONCLUSION:
1.) Sample meets all relevant requirements of IS 15885 (Part 2/Sec 13):2012+A1:2015

2.) Sample fails to meet the following test requirements: N/A

3) I hereby, undertake that the verdict stated in the test report for all the tests matches with the
test results.

(Signature of Authorized person with Stamp)

Page 2 ULR- TC646824000001461F


Page 6 of 52 Discipline-Electrical Testing Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 1 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Manufacturer Uniglobus Electricals & Electronics Private Limited


C/O POLYCAB UNIT 4, NURPURA,HALOL VADODARA ROAD,
HALOL, PANCH MAHALS, PIN-389350, GUJARAT,
GUJARAT,389350
Constant Current LED Driver ( AC Supplied Electronic Controlgear for
Test item:
LED Modules)
Identification UGM320U090X7 Serial No.: Nil
URS/LAB/ECG/23-24/888DEF22 / Date of
Receipt No.: 07/02/2024
24E5F40N receipt:
URS PRODUCTS AND TESTING PRIVATE LIMITED
Testing laboratory and its address:
F-3, Sector-6 Noida-201301
IS 15885 (Part 2/Sec13): 2012+A1:2015 in conjunction with IS 15885
Test specification:
(Part 1): 2011+A1:2015
Test Result: The test item passed the test specification(s)
Other Aspects:
This report consists of 46 pages including one attachment
-Equipment under test(EUT) Constant Current LED Driver ( AC Supplied Electronic Controlgear for LED Modules) Model:
UGM320U090X7 has been tested as per IS 15885(Part
2/Sec 13):2012+A1: 2015 complies with all applicable parameters.
-Compliance statement in this report has been made considering decision rule as inherent in its test standard and the latest
version of ILAC G-8.

Approved by /
Tested by: Issued by:
Authorized Signatory:

Himanshu Sharma , Manager


Ram Narayan Patel , Analyst Ranjan Kumar , Asst.Manager
Technical
Date:29/02/2024 Date:29/02/2024 Date:29/02/2024

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 7 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 2 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

TEST REPORT
IS 15885 (Part 2/Sec13): 2012+A1:2015 in conjunction with IS 15885 (Part 1): 2011+A1:2015
SAFETY OF LAMP CONTROL GEAR
PART 2: PARTICULAR REQUIREMENTS
Section 13 : DC or AC supplied electronic Controlgear for LED Modules
Report Reference No. SC24EPI01632_1
Date of issue : 29/02/2024
Total number of pages 46
Uniglobus Electricals & Electronics Private Limited
Applicant’s name :
C/O POLYCAB UNIT 4, NURPURA,HALOL VADODARA ROAD, HALOL, PANCH MAHALS, PIN-389350,
Address
GUJARAT, GUJARAT,389350
Test specification:
Standard IS 15885 (Part 2/Sec13): 2012+A1:2015 in conjunction with IS 15885 (Part 1): 2011+A1:2015
Test procedure Compliance Report
Non-standard test method N/A
Test Report Form No: BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1
Test Report Form(s) Originator Bureau of Indian Standards
Master TRF 03/01/2017
Test item description: Constant Current LED Driver ( AC Supplied Electronic Controlgear for LED Modules)

Trade Mark

Manufacturer Uniglobus Electricals & Electronics Private Limited


Model/Type reference UGM320U090X7

Ratings Input: 100-240V~, (Vmax:285V~), 50/60Hz, 3.8A max, PF:≥0.95, 320w max, Ta:-20 to 50°C, Tc:90°C, IP67
Output:78-90VDC, 0.5-3.25A, 300W

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 8 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 3 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Approved by /
Tested by: Issued by:
Authorized Signatory:

Himanshu Sharma , Manager


Ram Narayan Patel , Analyst Ranjan Kumar , Asst.Manager
Technical
Date:29/02/2024 Date:29/02/2024 Date:29/02/2024

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 9 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 4 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Total no.
Total No. of
of
No. tests/ Page
Test Code Description Measurement/ testing applicable
of Req. No.
tests/
tests passed
Req.
Marking
EL 2300 Marking 24 03/12 03/12 8
Requirements
Protection against
EL 2301 Insulating properties accidental contact with 21 03/01 03/01 10
live parts
EL 2302 Mechanical Properties Terminals 06 00/00 00/00 12
Provisions for protective
EL 2303 Insulating properties 22 01/06 01/06 13
earthing
EL 2304 Insulating properties Moisture resistance 02 02/00 02/00 15
EL 2305 Insulating properties Electric strength 07 05/01 05/01 16
Thermal endurance test
EL 2306 Thermal properties 01 00/00 00/00 17
for windings of ballasts
EL 2307 Insulating properties Fault conditions 17 09/04 09/04 18
EL 2308 Insulating properties Transformer heating 12 00/00 00/00 20
EL 2309 Mechanical Properties Construction 04 02/01 02/01 21
Creepage distances and
EL 2310 Safety requirements 05 00/00 00/00 22
clearances
Screws, current-carrying
EL 2311 Mechanical Properties 24 03/05 03/05 23
parts and connections
Resistance to heat, fire
EL 2312 Safety requirements 15 00/00 00/00 24
and tracking
EL 2313 Safety requirements Resistance to corrosion 02 01/00 01/00 25
Certificate: It is certified that the above tests were performed and found to be Table –
List of Attachments in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 10 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 5 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Copy of marking label:

Trade mark

Marking Plate for model: UGM320U090X7

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 11 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 6 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Table – List of Attachments


Attachment No. Attachment Description No. of pages in Attachment
Attachment – 1 Detail of IP Test sheet 45
Attachment – 2 Photo document 46
General remarks:
The test results presented in this report relate only to the object tested
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
Possible test case verdicts:
- test case does not apply to the test object: N/A
- test object does meet the requirement : P (Pass)
- test object does not meet the requirement : F (Fail)
Testing:
Date of receipt of test item: 07/02/2024
Date(s) of performance of tests: 07/02/2024 to 29/02/2024
Laboratory conditions
Ambient Temperature: (15-35) °C
Ambient Humidity: (45-75) %RH

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 12 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 7 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

General product information:


The equipment under test (EUT) is a Constant Current LED Driver ( AC Supplied Electronic Controlgear for LED Modules),
Model: UGM320U090X7 has been tested as per IS 15885 (Part 2/Sec13):2012+A1:2015 complies with all applicable
parameters
Equipment Name: Constant Current LED Driver ( AC Supplied Electronic Controlgear for LED Modules)

Brand:
Model: UGM320U090X7
Electrical Rating: Input: 100-240V~, (Vmax:285V~), 50/60Hz, 3.8A max, PF:≥0.95, 320w max, Ta:-20 to 50°C, Tc:90°C, IP67
Output:78-90VDC, 0.5-3.25A, 300W
( see copy of marking plate at page number 4)
Note: Sample has been tested at 50Hz only
Report Summary: All applicable tests according to the referenced standard(s) have been carried out.
1) Similarities:
N/A
2) Differences between the models:

N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 13 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 8 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Clause Test result/


Test / Requirement name Code Verdict
No observation
4 (4) GENERAL REQUIREMENTS See below N/A
Insulation materials according
(see Annex
requirements in Annex I of IS Not a SELV Control gear --
I)
15885-1+A1:2015

Clause No Test / Requirement name Code Test result/ observation Verdict


6 (6) CLASSIFICATION See below P
Built-in controlgear Yes No No --
Independent controlgear : Yes No Yes --
Integral controlgear : Yes No No --
Protection against electric shock controlgear:
(-) Yes No Yes --
(A1: Oct. 2015 to IS 15885(Pt.2/Sec 13))
Auto-wound controlgear : Yes No No --
Separating controlgear : Yes No No --
Isolating controlgear : Yes No Yes --
SELV controlgear : Yes No Not a SELV Control gear --

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 14 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 9 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Marking Requirements EL 2300 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
7(7) MARKING See below P
7.1 (7.1) Mandatory markings EL 2300-00 Marking is located on outer surface of enclosure P

a) mark of origin* EL 2300-01 P

b) model number or type reference* EL 2300-02 UGM320U090X7 P


c) symbol for independent lamp
EL 2300-03 Complied P
controlgear, if applicable*
d) correlation between
interchangeable parts and EL 2300-04 No such interchangeable parts N/A
controlgear marked*
e) rated supply voltage or voltage
EL 2300-05 100-240VAC P
range (V)*
supply frequency(Hz)* EL 2300-06 50/60Hz P
supply current (A)* EL 2300-07 3.8A P
f) earthing symbol* EL 2300-08 Marked P
k) number, type and wattage of
EL 2300-09 300W P
lamp(s)*
m) wiring diagram* EL 2300-10 Marked P
p) symbol for declared temperature* EL 2300-11 Marked P
t) symbol S* EL 2300-12 No such symbol marked N/A
Constant voltage type:* EL 2300-13 No N/A
-rated output voltage (V)* EL 2300-14 Constant current type N/A
Constant current type:* EL 2300-15 Yes P
-rated output current (A):* EL 2300-16 0.5-3.25A P
-indication if for LED modules only* EL 2300-17 Complied P
7.1(7.2) Marking durable and legible EL 2300-18 Marking durable and legible after the test P
Rubbing 15 s water, 15 s petroleum;
EL 2300-19 Marking durable and legible after the test P
marking legible
Information to be provided, if
7.2(7.1) EL 2300-20 See below P
Applicable*
h)declaration on protection against
EL 2300-21 Complied P
accidental contact*
j)cross-section of conductors (mm²)* EL 2300-22 No such construction used N/A
s)symbol D* EL 2300-23 No such symbol marked N/A
7.3 BIS certification marking* EL 2300-24 Not marked N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 15 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 10 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

*- Total number of Requirements to be observed / inspected =22


Total No. of applicable Requirement =12
No. of Requirements for which the sample passed =12
Total number of tests to be conducted =03
Total No. of applicable Tests =03
No. of tests for which the sample passed =03
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 16 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 11 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Insulating properties EL 2301 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
PROTECTION AGAINST ACCIDENTAL CONTACT WITH
8(10) EL 2301-00 See below P
LIVE PARTS
Enclosure providing sufficient protection
Controlgear protected against accidental contact with live
-(10.1) EL 2301-01 and limiting against accidental contact P
parts
with any live part
Lacquer or enamel not used for
Lacquer or enamel not used for protection or insulation* EL 2301-02 P
protection
Adequate mechanical strength on parts providing 10N force applied with test finger,
EL 2301-03 P
protection Hazards not occurred
-(10.2) Capacitors > 0,5 µF: voltage after 1 min (V): < 50 V EL 2301-04 Capacitor is not greater than 0.5 µF N/A
Controlgear providing SELV A1: NOV.2015 to IS 15885
-(10.3) EL 2301-05 Not a SELV control gear N/A
(PART 1)
Accessible conductive parts are insulated from live parts
EL 2301-06 As above N/A
by double or reinforced insulation in SELV controlgear*
No connection between output circuit and the body or
EL 2301-07 As above N/A
protective earthing circuit
No possibility of connection between output circuit and the
body or protective earthing circuit through other EL 2301-08 As above N/A
conductive parts
SELV outputs separated by at least basic insulation* EL 2301-09 As above N/A
No such ELV circuit used in
ELV conductive parts insulated as live parts* EL 2301-10 N/A
construction
No such ELV circuit used in
Tests according Annex M of IS15885-1* N/A
construction
Accessible conductive parts in SELV circuits A1:
-(10.4) EL 2301-11 No SELV circuit used in construction N/A
NOV.2015 to IS 15885 (PART 1)
Output voltage under load ≤ 25 Vr.m.s. or ≤ 60 V dc. EL 2301-12 As above N/A
If output voltage > 25 V r.m.s. or > 60 V d.c.; touch current
EL 2301-13 As above N/A
does not exceed
a) 0.7 mA(peak) EL 2301-14 As above N/A
b) 2 mA d.c. EL 2301-15 As above N/A
c) No load output ≤ 35 V peak or ≤ 60 V d.c EL 2301-16 As above N/A
One conductive part is insulated if output voltage or
current exceeding the values above and withstand test EL 2301-17 As above N/A
voltage 500 V
Double or reinforced insulation bridged by appropriate and
at least two resistors or two Y2 capacitors or one Y1 EL 2301-18 No such construction N/A
capacitors
Y1 or Y2 capacitors comply with ISQC 302400* EL 2301-19 As above N/A
Resistors comply with test (a) in 14.1 of IS 616* EL 2301-20 No such components used N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 17 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 12 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

*- Total number of Requirements to be observed / inspected =06


Total No. of applicable Requirement =01
No. of Requirements for which the sample passed =01
Total number of tests to be conducted =15
Total No. of applicable Tests =03
No. of tests for which the sample passed =03
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 18 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 13 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Mechanical properties EL 2302 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
9(8) TERMINALS See below N/A
Screw terminals according section 14 of IS 10322 Part 1,
EL 2302-00 No such screw terminal used N/A
2014:
Separately approved; component list* EL 2302-01 As above N/A
Part of the controlgear* EL 2302-02 No such screw less terminal used N/A
Screw less terminals according section 15 of IS 10322
EL 2302-03 No such screw less terminal used N/A
Part 1,2014:
Separately approved; component list* EL 2302-04 As above N/A
Part of the controlgear* EL 2302-05 As above N/A
*- Total number of Requirements to be observed / inspected =04
Total No. of applicable Requirement =00
No. of Requirements for which the sample passed =N/A
Total number of tests to be conducted =02
Total No. of applicable Tests =00
No. of tests for which the sample passed =N/A
Certificate: It is certified that the above tests were performed and found to be Not applicable in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 19 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 14 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Insulating properties EL 2303 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
10(9) PROVISION FOR PROTECTIVE EARTHING See below P
Lamp control gear provided with
Provisions for protective earthing* EL 2303-00 P
protective earthing
Terminal complying with clause 8 EL 2303-01 No such construction N/A
Locked against loosening and not possible to loosen by
EL 2303-02 As above N/A
hand
Not possible to loosen clamping means unintentionally on
EL 2303-03 No such construction N/A
screwless terminals
Earthing via means of fixing* EL 2303-04 As above N/A
Earthing terminal only used for the earthing of the control
EL 2303-05 Complied P
gear*
All parts of material minimizing the danger of electrolytic
EL 2303-06 Complied P
corrosion
Made of brass or equivalent material* EL 2303-07 Complied P
Contact surface bare metal* EL 2303-08 Complied P
Provision for functional earthing* EL 2303-09 No such construction N/A
Comply with clause 8 EL 2303-10 No such construction N/A
Earth contact via the track on the printed board EL 2303-11 Complied P
Test with a current of 25 A between earthing terminal and
each of the accessible metal parts; measured resistance EL 2303-12 0.004 ohm P
(Ω) at ≥ 10 A according 7.2.3 of IS 10322-1: < 0,5 Ω
Earthing of built-in lamp controlgear* EL 2303-13 Independent control gear N/A
Earth by means of fixing to earthed metal of luminaire in
EL 2303-14 No such construction N/A
compliance of 7.2 of IS 10322-1
Earthing terminal only for earthing the built-in controlgear* EL 2303-15 As above N/A
Earthing via independent controlgear* EL 2303-16 Complied P
Earth connection to other equipment* EL 2303-17 No such construction N/A
Looping or through connection, conductor min. 1,5 mm²
EL 2303-18 No looping or through connection used N/A
and of copper or equivalent
Protective earthing wires in line with 5.3.1.1 and clause 7* EL 2303-19 Complied P
Earthing of the lamp compartments powered via the
EL 2303-20 Complied P
independent lamp controlgear*
Test with a current of 25 A between input and output earth
terminals; measured resistance (Ω) between earthing
EL 2303-21 No such construction N/A
terminal and each of the accessible metal parts at ≥ 10 A
according 7.2.3 of IS 10322-1: < 0,5 Ω

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 20 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 15 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

*- Total number of Requirements to be observed / inspected =12


Total No. of applicable Requirement =06
No. of Requirements for which the sample passed =06
Total number of tests to be conducted =10
Total No. of applicable Tests =01
No. of tests for which the sample passed =01
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 21 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 16 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Insulating properties EL 2304 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
11 MOISTURE RESISTANCE AND INSULATION See below P
After storage 48 h at 91-95% relative humidity and
No damage after Humidity test carried
11.1 20-30°C measuring of insulation resistance with d.c. 500 EL 2304-00 P
out at 27°C and 93%Rh for 48hrs.
V, 1min(MΩ):
Insulation Resistance: >1 Giga ohm, (
11.2 For basic insulation ≥2 MΩ EL 2304-01 Between live parts to accessible metal P
Body )
*- Total number of Requirements to be observed / inspected =00
Total No. of applicable Requirement =00
No. of Requirements for which the sample passed =N/A
Total number of tests to be conducted =02
Total No. of applicable Tests =02
No. of tests for which the sample passed =02
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 22 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 17 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Insulating properties EL 2305 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
12(12) ELECTRIC STRENGTH See Below P
Test conducted for 1min. No flashover
Immediately after clause 11 electric strength test for 1 min EL 2305-00 P
or breakdown occurs during the test
Working voltage ≤ 42 V, test voltage 500 V EL 2305-01 Exceeding 42V N/A
Working voltage > 42 V ≤ 1000 V, test voltage(V): EL 2305-02 Complied P
Test Voltage: 1480Vac, (Between live
Basic insulation, 2U + 1000 V EL 2305-03 P
parts of different polarity)
Supplementary insulation, 2U + 1000 V EL 2305-04 As above N/A
Test Voltage: 2960Vac, (Between live
Double or reinforced insulation, 4U + 2000 V EL 2305-05 P
parts to accessible metal Body)
Electric strength test withsood, No
No flashover or breakdown* EL 2305-06 P
flashover or breakdown occurred
*- Total number of Requirements to be observed / inspected =01
Total No. of applicable Requirement =01
No. of Requirements for which the sample passed =01
Total number of tests to be conducted =06
Total No. of applicable Tests =05
No. of tests for which the sample passed =05
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 23 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 18 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Thermal Properties EL 2306 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
THERMAL ENDURANCE TEST FOR WINDINGS OF
13(13) EL 2306-00 No such type of ballast N/A
BALLASTS
THERMAL ENDURANCE TEST FOR WINDING OF
EL 2306-00 As above N/A
BALLASTS
*- Total number of Requirements to be observed / inspected =00
Total No. of applicable Requirement =00
No. of Requirements for which the sample passed =N/A
Total number of tests to be conducted =00
Total No. of applicable Tests =00
No. of tests for which the sample passed =N/A
Certificate: It is certified that the above tests were performed and found to be not applicable in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 24 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 19 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Insulating properties EL 2307 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
14(14) FAULT CONDITIONS See below P
(14) When operated under fault conditions the controlgear: EL 2307-00 Complied P
- does not emit flames or molten material* EL 2307-01 Not emitted flames or molten material P
- does not produce flammable gases* EL 2307-02 Not produces flammable gases P
Adequate Protection against accidental
- protection against accidental contact not impaired EL 2307-03 P
contact
Thermally protected controlgear does not exceed the
EL 2307-04 Complied P
marked temperature value
Fault conditions: capacitors, resistors or inductors without Totally enclosed lamp control gear Only
proof of compliance with relevant specifications have been EL 2307-05 output terminal short circuited (see P
short-circuited or disconnected appended table Cl 14)
Short-circuit of creepage distances and clearances if less
(14.1) than specified in clause 16 in Part 1 (Except between live EL 2307-06 No such construction N/A
parts and accessible metal parts)
Creepage distances on printed boards less than specified
in clause 16 in Part 1 provided with coating according to IS EL 2307-07 No such Construction N/A
15382-3
Totally enclosed lamp control gear Only
(14.2) Short-circuit or interruption of semiconductor devices EL 2307-08 N/A
output terminal short circuited
Short-circuit across insulation consisting of lacquer, Lacquer, enamel or textile not used for
(14.3) EL 2307-09 N/A
enamel or textile insulation
Totally enclosed lamp control gear Only
(14.4) Short-circuit across electrolytic capacitors EL 2307-10 N/A
output terminal short circuited
After the tests has been carried out on samples: EL 2307-11 See below P
The insulation resistance ≥ 1 MΩ EL 2307-12 Insulation Resistance: >1 Giga ohm P
No flammable gases Produced during
No flammable gases* EL 2307-13 P
test
No accessible parts have become live EL 2307-14 No Live Part become accessible P
During the tests, a tissue paper, where the test specimen
EL 2307-15 Tissue paper does not ignite during test P
is wrapped, does not ignite*
Temperature declared thermally protected lamp
EL 2307-16 Complied P
controlgear fulfil requirements in Annex C

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 25 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 20 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

*- Total number of Requirements to be observed / inspected =04


Total No. of applicable Requirement =04
No. of Requirements for which the sample passed =04
Total number of tests to be conducted =13
Total No. of applicable Tests =09
No. of tests for which the sample passed =09
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 26 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 21 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Insulating properties EL 2308 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
15(-) TRANSFORMER HEATING Not a SELV control gear N/A
Windings of separating transformer in a SELV-equivalent
controlgear fulfil the requirements according to M-6 and
EL 2308-00 As above N/A
M-7 of IS 15885-1 (IS 15885 (Part 2/Sec. 13 A1: Oct.
2015)
For SELV control gears, the output voltage shall not
EL 2308-01 As above N/A
exceed the limits given in 10.4 of IS 15885-1
Normal operation Comply with clause M-6 of IS 15885
15.1(-) EL 2308-02 As above N/A
(Part 1) (A1: Oct. 2015 to IS 15885 (Pt.2/Sec13 ))
For built-in and integral control gears tests shall be made
under conditions such that the convertors is brought to tc
EL 2308-03 As above N/A
as reached under normal operation at rated supply
voltage.
Abnormal operation Comply with clause M-7 of IS 15885
15.2(-) EL 2308-04 As above N/A
(Part 1) (A1: Oct. 2015 to IS 15885 (Pt.2/Sec13 ))
Test at any voltage between 90 percent and 110 percent of
the rated supply voltage shall be performed if relevant,
EL 2308-05 As above N/A
with the controlgear operating according to the
manufacturer's instructions for 1hr.
Connect double the LED modules or equivalent EL 2308-06 As above N/A
In parallel to the output terminals, for constant voltage
EL 2308-07 As above N/A
output types
In series to the output terminals, for the constant current
EL 2308-08 As above N/A
output types.
No flammable gases and smoke* EL 2308-09 As above N/A
No accessible parts have become live EL 2308-10 As above N/A
Ambient temperature at tc: EL 2308-11 As above N/A
*- Total number of Requirements to be observed / inspected =01
Total No. of applicable Requirement =00
No. of Requirements for which the sample passed =N/A
Total number of tests to be conducted =11
Total No. of applicable Tests =00
No. of tests for which the sample passed =N/A
Certificate: It is certified that the above tests were performed and found to be Not applicable in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 27 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 22 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Mechanical Properties EL 2309 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
16(15) CONSTRUCTION See below P
(15.1) Wood, cotton, silk, paper and similar fibrous material* EL 2309-00 Refers below P
Wood, cotton, silk, paper and similar fibrous material not
EL 2309-01 Such material not used as insulation P
used as insulation*
(15.2) Printed circuits EL 2309-02 See below P
Printed circuits used as internal connections complies with
EL 2309-03 Complied P
clause 14
*- Total number of Requirements to be observed / inspected =02
Total No. of applicable Requirement =01
No. of Requirements for which the sample passed =01
Total number of tests to be conducted =02
Total No. of applicable Tests =02
No. of tests for which the sample passed =02
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 28 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 23 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Safety Requirements EL 2310 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
17(16) CREEPAGE DISTANCES AND CLEARANCES See below N/A
Creepage distances and clearances according to Table 3 Totally enclosed control gear or
(16) EL 2310-00 N/A
and 4, as appropriate unless otherwise specified in 14 components
Insulating lining of metallic enclosures as per IS 10322-1 EL 2310-01 As above N/A
Basic insulation on printed boards tested according to
EL 2310-02 As above N/A
clause 14
Distances subjected to both sinusoidal voltage as
non-sinusoidal pulses not less than value in either Table 3 EL 2310-03 As above N/A
or 4
Creepage distances not less than minimum clearance EL 2310-04 As above N/A
*- Total number of Requirements to be observed / inspected =00
Total No. of applicable Requirement =00
No. of Requirements for which the sample passed =N/A
Total number of tests to be conducted =05
Total No. of applicable Tests =00
No. of tests for which the sample passed =N/A
Certificate: It is certified that the above tests were performed and found to be Not applicable in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 29 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 24 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Safety Requirements EL 2311 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
SCREWS, CURRENT-CARRYING PARTS AND
18(17) See below P
CONNECTIONS
Screws, current-carrying parts and connections in
compliance with IS 10322-1 (clause numbers between EL 2311-00 Complied P
parentheses refer to IS 10322-1)
(4.11) Electrical connections* EL 2311-01 Complied P
(4.11.1) Contact pressure* EL 2311-02 No such construction N/A
(4.11.2) Screws* EL 2311-03 No such construction N/A
- Self-tapping screws* EL 2311-04 No such construction N/A
- Thread cutting screws* EL 2311-05 No such construction N/A
(4.11.3) Screw locking* EL 2311-06 No such construction N/A
- Spring washer* EL 2311-07 No such construction N/A
- Rivets* EL 2311-08 No such construction N/A
(4.11.4) Material of current-carrying parts* EL 2311-09 Complied P
(4.11.5) No contact to wood or mounting surface* EL 2311-10 Complied P
(4.11.6) Electro-mechanical contact systems EL 2311-11 No such construction N/A
(4.12) Mechanical connections and glands EL 2311-12 No such construction N/A
(4.12.1) Screws not made of soft metal* EL 2311-13 Complied P
Screws of insulating material* EL 2311-14 Screws not made of insulating material P
Torque test: torque (Nm); part: EL 2311-15 Enclosure fixing screw:2.16, 0.40 Nm P
Torque test: torque (Nm); part: EL 2311-16 As above N/A
Torque test: torque (Nm); part: EL 2311-17 As above N/A
(4.12.2) Screws with diameter < 3 mm screwed into metal EL 2311-18 Complied P
(4.12.4) Locked connections: EL 2311-19 No locked connections used N/A
- Fixed arms; torque(Nm): EL 2311-20 No fixed arms used N/A
- lampholder; torque(Nm): EL 2311-21 No lampholder used N/A
- Push-button switches; torque 0,8 Nm: EL 2311-22 Push-button switches used N/A
(4.12.5) Screwed glands; force(Nm). EL 2311-23 No screwed glands used N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 30 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 25 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

*- Total number of Requirements to be observed / inspected =12


Total No. of applicable Requirement =05
No. of Requirements for which the sample passed =05
Total number of tests to be conducted =12
Total No. of applicable Tests =03
No. of tests for which the sample passed =03
Certificate: It is certified that the above tests were performed and found to be Passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 31 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 26 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Safety Requirements EL 2312 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
RESISTANCE TO HEAT, FIRE AND
19(18) See below N/A
TRACKING
(18.1) Ball-pressure test: EL 2312-00 See below N/A
-part tested; temperature(125˚C): EL 2312-01 Metallic Enclosure Used N/A
-part tested; temperature(75˚C): EL 2312-02 As above N/A
(18.2) Test of printed boards: EL 2312-03 Certified material used N/A
-part tested: EL 2312-04 As above N/A
-part tested: EL 2312-05 As above N/A
(18.3) Glow wire test (650˚C): EL 2312-06 See below N/A
-part tested: EL 2312-07 Metallic Enclosure Used N/A
-part tested: EL 2312-08 As above N/A
(18.4) Needle flame test (10 s): EL 2312-09 Certified material used N/A
-part tested: EL 2312-10 As above N/A
-part tested: EL 2312-11 As above N/A
(18.5) Tracking test: EL 2312-12 Certified material used N/A
-part tested: EL 2312-13 As above N/A
-part tested: EL 2312-14 As above N/A
*- Total number of Requirements to be observed / inspected =00
Total No. of applicable Requirement =00
No. of Requirements for which the sample passed =N/A
Total number of tests to be conducted =15
Total No. of applicable Tests =00
No. of tests for which the sample passed =N/A
Certificate: It is certified that the above tests were performed and found to be not applicable in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 32 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 27 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Tests relating to Safety Requirements EL 2313 – V1.1


Cl.No. Test / Requirement name Test Code Test result/ observation Verdict
20(19) RESISTANCE TO CORROSION See below P
- test according 4.18.1 of IS 10322-1. EL 2313-00 In compliance P
- adequate varnish on the outer surface* EL 2313-01 No such construction N/A
*- Total number of Requirements to be observed / inspected =01
Total No. of applicable Requirement =00
No. of Requirements for which the sample passed =N/A
Total number of tests to be conducted =01
Total No. of applicable Tests =01
No. of tests for which the sample passed =01
Certificate: It is certified that the above tests were performed and found to be passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 33 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 28 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Clause Requirement + Test Verdict


14 TABLE: tests of fault conditions P
Part Simulated fault Hazard

Output
Short circuit: Unit shutdown immediately, no output, no high temp No
Terminal

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 34 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 29 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

17 (16) TABLES: Creepage distances and clearances N/A


Table 3 Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages N/A
RMS working voltage (V) not exceeding 50 150 250 500 750 1000
Creepage distances
Required basic insulation, PTI ≥ 600 0,6 1,4 1,7 3 4 5,5

Required basic insulation, PTI < 600 1,2 1,6 2,5 5 8 10

Required supplementary insulation PTI ≥ 600 0,6 1,4 1,7 3 4 5,5

Required supplementary insulation PTI < 600 1,2 1,6 2,5 5 8 10

Required reinforced insulation 1,2 1,6 2,5 5 8 10

Clearances
Required basic insulation 2,0 3,2 3,6 4,8 6 8

Required supplementary insulation 2,0 3,2 3,6 4,8 6 8

Required reinforced insulation 2,0 3,2 3,6 4,8 6 8

Table 4 Minimum distances (mm) for non-sinusoidal pulse voltages N/A


Rated pulse voltage (peak kV) 2,0 2,5 3,0 4,0 5,0 6,0 8,0

Required clearances 1,0 1,5 2 3 4 5,5 8

Rated pulse voltage (peak kV) 10 12 15 20 25 30 40

Required clearances 11 14 18 25 33 40 60

Rated pulse voltage (peak kV) 50 60 80 20 100 -- --

Required clearances 75 90 130 170 -- -- --

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 35 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 30 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Clause Requirement + Test Verdict


ANNEX A - TEST TO ESTABLISH WHETHER A CONDUCTIVE PART IS A LIVE PART
A P
WHICH MAY CAUSE AN ELECTRIC SHOCK
Under consideration P

ANNEX C – PARTICULAR REQUIREMENTS FOR ELECTRONIC LAMP CONTROLGEAR


C P
WITH MEANS OF PROTECTION AGAINST OVERHEATING
C3 GENERAL REQUIREMENTS P
Thermal protection means integral with the convertor,
C3.1 In compliance P
protected against mechanical damage
Renewable only by means of a tool In compliance P
If function depending on polarity, for cord-connected
No such construction N/A
equipment protection means in both leads
Thermal links comply with this standard No such construction N/A
C3.2 No risk of fire by breaking (clause C7) In compliance P
C5 CLASSIFICATION P
a) automatic resetting type See below --
b) manual resetting type See below --
c) non-renewable, non-resetting type See below --
d) renewable, non-resetting type See below --
e) other type of thermal protection; description In compliance P
C6 MARKING P
Temperature declared on
C6.1 Symbol for temperature declared thermally protected ballasts P
marking (110°C)
C6.2 Declaration of the type of protection provided other type of thermal protection P
C7 LIMITATION OF HEATING P
C7.1 Preselection test: P
Test sample placed for at least 12 h in an oven having
In compliance P
temperature (tc-5) K
No operation of the protection device In compliance P

C7.2 Functioning of protection means: P


Normal operation of the sample in a test enclosure according
to Annex D at an ambient temperature such that (tc +0; -5) °C In compliance P
is obtained
No operation of the protection device In compliance P
Introducing of the most onerous test condition determined
In compliance P
during test of clause 14
Output of windings connected to the mains supply short-
circuited, and other part of the convertor operated under No such construction N/A
normal conditions
Increasing of the current through the windings continuously
No such construction N/A
until operation of the protection means
Continuous measuring of the highest surface temperature In compliance P

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 36 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 31 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Ballasts according to C5 a) or C5 e) operated until stable


In compliance P
conditions are achieved
Automatic-resetting thermal protectors working 3 times No such construction N/A
Ballasts according to C5 b) working 6 times No such construction N/A
Ballasts according to C5 c) and C5) d) working once No such construction N/A
Highest temperature does not exceed the marked value In compliance P
Any overshoot of 10% over the marked value within 15 min No such over shoot N/A
Clause Requirement + Test Verdict
ANNEX D – REQUIREMENTS FOR CARRY OUT THE HEATING TESTS OF THERMALLY
D P
PROTECTED LAMP CONTROLGEAR
Tests in C7 performed in accordance with Annex D, if applicable In compliance P

E ANNEX E – USE OF CONSTANT S OTHER THAN 4500 IN tw TESTS N/A


Comply with tests according Annex E S symbol not marked N/A

F ANNEX F - DRAUGHT-PROOF ENCLOSURE N/A


Draught-proof enclosure in accordance with the description No such construction N/A
Dimensions of the enclosure As above N/A
Other design; description As above N/A

H ANNEX H - TESTS N/A


All tests performed in accordance with the advice given in
As above N/A
Annex H, if applicable

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 37 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 32 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Clause Requirement + Test Verdict


ANNEX I IN THIS PART 2 – PARTICULAR ADDITIONAL REQUIREMENTS FOR SELV D.C. OR A.C.
I (M) N/A
SUPPLIED ELECTRONIC CONTROLGEARS FOR LED MODULES (A1: Nov. 2015 to IS 15885 (Pt.1)
(M.3) Classification N/A
a) According to their protection against electric shock Independent control gears are classified as follows: --

Class I Yes No --

Class II Yes No --

Class III Yes No --

b) According to the short-circuit protection or protection against abnormal use Control gears are classified
--
as follows:

Non-inherently short circuit proof controlgear Yes No --

Inherently short circuit proof controlgear Yes No --

Fail safe controlgear Yes No --

Non-short-circuit proof controlgear Yes No --

(M.4) Marking

Adequate symbols are used as per Table 7 Not a SELV control gear N/A

(M.5) Protection against electric shock N/A

Control gears providing SELV shall, in addition to the


requirements given in 10.3 and 10.4,Comply with clause 9.2 As above N/A
of IS/IEC 61558-1:2005

(M.6) Heating N/A

No excessive temperatures in normal use As above N/A

Value if capacitor tc marked As above N/A

Winding insulation classified as Class As above N/A

Comply with tests of clause 14 of IEC 61558-1 with


As above N/A
adjustments

(M.7) Short-circuit and overload protection N/A

Comply with tests of clause 15 of IS/IEC 61558-1 :2005 with


As above N/A
adjustments

(M.8) Insulation resistance and electric strength N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 38 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 33 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

(M.8.1) Conditioned 48 h between 91 % and 95 % As above N/A

(M.8.2) Insulation resistance N/A

Between input- and output circuits not less than 5 MΩ : As above N/A

Between metal parts of class II convertors which are


separated from live parts by basic insulation only and the As above N/A
body not less than 5 MΩ

Between metal foil in contact with the inner and outer


surfaces of enclosures of insulating material not less than 2 As above N/A
MΩ :

(M.8.3) Electric strength N/A

1) Between live parts of input circuits and live parts of output


As above N/A
circuits

2) Over basic or supplementary insulation between: N/A

a) live parts having different polarity : As above N/A

b) live parts and body if intended to be connected to


As above N/A
protective earth :

c) accessible metal parts and a metal rod of the same


As above N/A
diameter as the flexible cable or cord :

d) live parts and an intermediate metal part : As above N/A

e) intermediate metal parts and the body : As above N/A

f) each input circuit and all other input circuits : As above N/A

3) Over reinforced insulation between the body and live parts As above N/A

(M.9) Construction N/A

Transformer comply with 19.12 of IS/ IEC 61558-1 and 19 of


(M.9.1) As above N/A
IS/IEC 61558-2-6

HF transformer comply with 19 of IS/ IEC 61558-2-16 As above N/A

(M.10) Components N/A

Protective devices comply with 20.6 – 20.11 of IS/IEC


As above N/A
61558-1

(M.11) Creepage distances, clearances and distances through insulation N/A

Creepage distances and clearances not less than the values


As above N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 39 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 34 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

shown in Table 3 of IS 15885 Part 1 and Table 11 of A1 Nov.


2015 of IS 15885 Part 1 :

Distance through insulation according Table 11 in IS 15885 Part 1 N/A


1) Basic distance through insulation N/A

Required distance (mm) : As above N/A

Measured (mm) : As above N/A

Supplementary information As above N/A

2) Supplementary distance through insulation N/A

Required distance (mm) : As above --

Measured (mm) : As above N/A

Supplementary information As above --

3) Reinforced distance through insulation N/A

Required distance (mm) : As above --

Measured (mm) : As above N/A

Supplementary information As above --

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 40 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 35 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

ANNEX 1: Requirement + Test Verdict


Components P
Manufacturer/ Mark(s) of
Object/part No Code Type/model Technical data Standard
trademark conformity
MODEL: UGM320U090X7
SCHURTER
Fuse A ELECTRONICS SRT 6.3A, 300V UL 248-1 (#) UL E501509
(INDIA) PVT LTD
SCHURTER
Alternate D ELECTRONICS SRT Series 0.63-6.3A, 300V UL 248-1 (#) UL E501509
(INDIA) PVT LTD
Watts Electronics
Alternate D WWFH1, WWFHS2 1W-10W UL 248-1 (#) UL E498797
Private Limited
Alternate D LITTELFUSE INC 369+ Series 0.8-6.3A, 250V UL 248-1 (#) UL E67006
Alternate D LITTELFUSE INC 369+ Series 0.8-6.3A, 300V UL 248-1 (#) UL E67006
SHENZHEN WEIDY
INDUSTRIAL UL1434, ANSI/UL
NTC A MF72 240V UL E527944
DEVELOPMENT CO 60730-1,
LTD
SHENZHEN WEIDY
INDUSTRIAL UL1434, ANSI/UL
Alternate D MF72 Series 120V/ 240V UL E527944
DEVELOPMENT CO 60730-1,
LTD
TDK (Zhuhai FTZ)
Alternate D S235/**/M** 110/230 UL 1434 (#) UL E338926
Co., Ltd.
TDK (Zhuhai FTZ)
Alternate D S153/**/M** 110/230 UL 1434 (#) UL E338926
Co., Ltd.
TDK (Zhuhai FTZ)
Alternate D S236/**/M** 110/230 UL 1434 (#) UL E338926
Co., Ltd.
TDK (Zhuhai FTZ)
Alternate D S237/**/M** 110/230 UL 1434 (#) UL E338926
Co., Ltd.
TDK (Zhuhai FTZ)
Alternate D S238/**/M** 110/230 UL 1434 (#) UL E338926
Co., Ltd.
THINKING
Alternate D ELECTRONIC SCK series 120V/ 240V UL 1434 (#) UL E138827
INDUSTRIAL CO LTD
DEKI ELECTRONICS 0.047uf- 0.47uf,
X Capacitors A IS/MKP X2 UL 60384-14 (#) UL E519274
LTD 310V
TDK (Zhuhai FTZ) B3292#E2/F2/G2/L2 0.047uF- 0.47uf,
Alternate D UL 60384-14 (#) UL E97863
Co., Ltd. /X2/Y2/Z2 275V
TDK (Zhuhai FTZ) 0.047uF- 0.47uf,
Alternate D B3293 UL 60384-14 (#) UL E97863
Co., Ltd. 305V
TDK (Zhuhai FTZ) 0.047uF- 0.47uf,
Alternate D B3292#E/F/G3 UL 60384-14 (#) UL E97863
Co., Ltd. 305V
SHENZHEN WEIDY
INDUSTRIAL 0.047uF- 0.47uf,
Alternate D MKP X2 UL 60384-14 (#) UL E334332
DEVELOPMENT CO 275V/305V/ 310V
LTD
Y Capacitors A TDK Corporation CD Series 10-4700pF, 400Vac, DIN EN 60384-14 VDE- 40017931

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 41 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
)6HFWRU1RLGD
7  
(LQIR#XUVODEVFRP:ZZZXUVODEVFRP
&,11288337&

5HSRUW1R6&(3,B 3DJHRI
,6 3DUW6HF $
'DWHG

$OWHUQDWH ' 7'.&25325$7,21 &'6HULHV S)9DF 8/  8/(


6KHQ]KHQ:HLG\
,QGXVWULDO
$OWHUQDWH ' $56HULHV S)9DF ',1(1 9'(
'HYHORSPHQW&R
/WG
.(0(7
$OWHUQDWH ' (/(&7521,&6 .-1VHULHV <9DF 8/  8/(
&253
9,6+$<
$OWHUQDWH ' 9<6HULHV <9DF 8/  8/(
(/(&7521,&*0%+
9,6+$<(OHFWURQLF
$OWHUQDWH ' 9<6HULHV <9DF ',1(1 9'(
*PE+
,(&$QQH[
4,(&,(&
,(&
9DULVWRU 029  7'.(OHFWURQLFV
$ 6 'LDPP $0' 9'(
029 *PE+ &R2*
,(&*
,(&$7
,VVXH
,(&$QQH[
4,(&,(&
,(&
7'.(OHFWURQLFV
$OWHUQDWH ' S10*S14, Dia- 10mm, 14mm $0' 9'(
*PE+ &R2*
,(&*
,(&$7
,VVXH
/$VHULHV
'LVF6L]H
$OWHUQDWH ' /LWWHOIXVH 8OWUD029VHULHV0 8/ 8/(
PP
VHULHV;WUHPHVHULHV
6+(1=+(1:(,'<
,1'8675,$/
$OWHUQDWH ' 9 6HULHV 6''' 8/ 8/(
'(9(/230(17&2
/7'
:25/'352'8&76
$OWHUQDWH ' (96HULHV9=6HULHV ''' 8/ 8/(
,1&
THINKING
ELECTRONIC TVR14-V, TVR14,
Alternate D TVR10-V, TVR10, Disc Size- 10, 14, UL1449 UL E490998
INDUSTRIAL CO
TVR20 20mm
LTD
IEC 60950-1:2013/Annex Q;
IEC 61051-1:2007; IEC
61051-2:1991; IEC
61051-2:1991/AMD1:2009; VDE 40027582
IEC 62368-1:2014/G.8.2; IEC
Varistor ( MOV1), ( A TDK Electronics
61051-2-2 AT 0001 Issue
MOV4) GmbH & Co OG S14* Dia- 14mm 11:2018-02
IEC 60950-1:2013/Annex
Q; IEC 61051-1:2007; IEC
61051-2:1991; IEC
TDK Electronics
Alternate D S10*,S20* Dia- 10mm,Dia- 61051-2:1991/AMD1:2009; VDE 40027582
GmbH & Co OG
20mm IEC 62368-1:2014/G.8.2;
IEC 61051-2-2 AT 0001
Issue 11:2018-02
Alternate LA series,
Littelfuse Disc Size- 10, 14, UL1449 UL E320116
D UltraMOVseries, M3
series, Xtreme series 20mm
TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1
Discipline-Electrical Testing ULR- TC646824000001461F
Page 42 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
)6HFWRU1RLGD
7  
(LQIR#XUVODEVFRP:ZZZXUVODEVFRP
&,11288337&

5HSRUW1R6&(3,B 3DJHRI
,6 3DUW6HF $
'DWHG

6+(1=+(1:(,'<
,1'8675,$/
$OWHUQDWH ' 9 6HULHV 6''' 8/ 8/(
'(9(/230(17&2
/7'
:25/'352'8&76
$OWHUQDWH ' (96HULHV9=6HULHV ''' 8/ 8/(
,1&
32/<&$%:,5(397
,QSXW:LUH $ 39&,QVXODWHG 9[VTPP ,6 %,6&0/
/7'
9[
VTPP
32/<&$%:,5(397 [VTPP
$OWHUQDWH ' 39&,QVXODWHG ,6 %,6&0/
/7' [VTPP
[VTPP
[VTPP
9[
VTPP
32/<&$%:,5(397
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 %,6&0/
/7'
[VTPP
[VTPP
9[
32/<&$%:,5(397 VTPP
$OWHUQDWH ' 39&,QVXODWHG ,6 %,6&0/
/7' [VTPP
[VTPP
9[
VTPP
$OWHUQDWH ' 55.$%(//,0,7(' 39&,QVXODWHG [VTPP ,6 %,6&0/
[VTPP
[VTPP
9[
VTPP
$OWHUQDWH ' 55.$%(//,0,7(' 39&,QVXODWHG [VTPP ,6 %,6&0/
[VTPP
[VTPP
9[
VTPP
$OWHUQDWH ' 55.$%(//,0,7(' 39&,QVXODWHG [VTPP ,6 %,6&0/
[VTPP
[VTPP
9[
VTPP
52//,)/(;&$%/(6
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
397/7'
[VTPP
[VTPP
9[
VTPP
52//,)/(;&$%/(6
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
397/7'
[VTPP
[VTPP
9[
VTPP
52//,)/(;&$%/(6
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
397/7'
[VTPP
[VTPP

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 43 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
)6HFWRU1RLGD
7  
(LQIR#XUVODEVFRP:ZZZXUVODEVFRP
&,11288337&

5HSRUW1R6&(3,B 3DJHRI
,6 3DUW6HF $
'DWHG

9[
VTPP
52/<&$%
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
,1'8675,(6
[VTPP
[VTPP
9[
VTPP
52/<&$%
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
,1'8675,(6
[VTPP
[VTPP
9[
VTPP
52/<&$%
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
,1'8675,(6
[VTPP
[VTPP
9[
8.% VTPP
%,6&0/
$OWHUQDWH ' (/(&7521,&6397 5XEEHU [VTPP ,6

/7' 81,7,, [VTPP
[VTPP
9[
8.% VTPP
%,6&0/
$OWHUQDWH ' (/(&7521,&6397 5XEEHU [VTPP ,6

/7' 81,7,, [VTPP
[VTPP
9[
8.% VTPP
%,6&0/
$OWHUQDWH ' (/(&7521,&6397 5XEEHU [VTPP ,6

/7' 81,7,, [VTPP
[VTPP
9[
VTPP
)RUWLV&DEOHV3YW %,6&0/
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6
/WG 
[VTPP
[VTPP
9[
VTPP
)RUWLV&DEOHV3YW %,6&0/
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6
/WG 
[VTPP
[VTPP
9[
VTPP
)RUWLV&DEOHV3YW %,6&0/
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6
/WG 
[VTPP
[VTPP
$:*ƒ&
$OWHUQDWH ' +HOX.DEHO*PE+  8/  8/(
9
$:*ƒ&
$OWHUQDWH ' +HOX.DEHO*PE+  8/  8/(
9
32/<&$%:,5(397
2XWSXW:LUH $ 39&,QVXODWHG 9[VTPP ,6 %,6&0/
/7'

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 44 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
)6HFWRU1RLGD
7  
(LQIR#XUVODEVFRP:ZZZXUVODEVFRP
&,11288337&

5HSRUW1R6&(3,B 3DJHRI
,6 3DUW6HF $
'DWHG

9[
VTPP
32/<&$%:,5(397
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 %,6&0/
/7'
[VTPP
[VTPP
9[
VTPP
32/<&$%:,5(397
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 %,6&0/
/7'
[VTPP
[VTPP
9[
VTPP
$OWHUQDWH ' 55.$%(//,0,7(' 39&,QVXODWHG [VTPP ,6 %,6&0/
[VTPP
[VTPP
9[
VTPP
$OWHUQDWH ' 55.$%(//,0,7(' 39&,QVXODWHG [VTPP ,6 %,6&0/
[VTPP
[VTPP
9[
VTPP
52//,)/(;&$%/(6
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
397/7'
[VTPP
[VTPP
9[
VTPP
52//,)/(;&$%/(6
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6 &0/
397/7'
[VTPP
[VTPP
9[
VTPP
$OWHUQDWH ' 52/<&$%,QGXVWULHV 39&,QVXODWHG [VTPP ,6 &0/
[VTPP
[VTPP
9[
VTPP
$OWHUQDWH ' 52/<&$%,QGXVWULHV 39&,QVXODWHG [VTPP ,6 &0/
[VTPP
[VTPP
9[
8.% VTPP
%,6&0/
$OWHUQDWH ' (/(&7521,&6397 5XEEHU [VTPP ,6

/7' 81,7,, [VTPP
[VTPP
9[
8.% VTPP
%,6&0/
$OWHUQDWH ' (/(&7521,&6397 5XEEHU [VTPP ,6

/7' 81,7,, [VTPP
[VTPP
9[
)RUWLV&DEOHV3YW VTPP %,6&0/
$OWHUQDWH ' 39&,QVXODWHG ,6
/WG [VTPP 

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 45 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
)6HFWRU1RLGD
7  
(LQIR#XUVODEVFRP:ZZZXUVODEVFRP
&,11288337&

5HSRUW1R6&(3,B 3DJHRI
,6 3DUW6HF $
'DWHG

[VTPP
[VTPP
9[
VTPP
)RUWLV&DEOHV3YW %,6&0/
$OWHUQDWH ' 39&,QVXODWHG [VTPP ,6
/WG 
[VTPP
[VTPP
$:*ƒ&
$OWHUQDWH ' +HOX.DEHO*PE+  8/  8/(
9
$:*ƒ&
$OWHUQDWH ' +HOX.DEHO*PE+  8/  8/(
9
(3,720(
3&% (3 9ƒ& )5 8/  8/(
&20321(176/7'
(3,720(
$OWHUQDWH ' (3$(3 9ƒ& )5 8/  8/(
&20321(176/7'
$6&(17&,5&8,76
$OWHUQDWH ' % '6'6 9ƒ& )5 8/  8/(
397/7'
*ROGHQPD[
,QWHUQDWLRQDO
$OWHUQDWH ' */ 9ƒ& 8/  8/(
7HFKQRORJ\
+DQJ]KRX /WG
6,*0$
$OWHUQDWH ' $ 9ƒ& 8/  8/(
7(&+12/2*,(6
=DNODG\7ZRU]\Z (3*&
$OWHUQDWH ' 6]WXF]Q\FK,=2(5* 76(&8 9ƒ& 8/  8/(
6S]RR 76(&8
$OWHUQDWH ' 79565/  9ƒ& 8/  8/(
$OWHUQDWH ' %3//7' $ 9ƒ& 8/  8/(
(/,7(0$7(5,$/&2
$OWHUQDWH ' (0(0 9ƒ& 8/  8/(
/7'
8QLJOREXV(OHFWULFDOV ,6 3DUW6HF 7HVWHGZLWK
7UDQVIRUPHU & 346HULHV &ODVV%
DQG(OHFWURQLFV/7'  $ $SSOLDQFH
&+$1*&+81
%REELQ % 7+) 9ƒ& 8/  8/(
3/$67,&6&2/7'
,17(.7$3(6397
,168/$7,217$3( $ ) ƒ& 8/$  8/(
/7'
6KHQ]KHQ<RX6DQ
$OWHUQDWH ' 7HFKQRORJ\ 3 E ƒ& 8/$  8/(
&R/LPLWHG
7$<$(/(&75,&
0$*1(7:,5( $ :,5( &$%/(&2 58(:) D ƒ& 8/ 8/(
/7'
5$05$71$:,5(6
$OWHUQDWH ' 55Y6+5$0,.66)& ƒ& 8/ 8/(
/7'
=+8+$,5216(1
683(5
$OWHUQDWH ' 8(:< ƒ& 8/ 8/(
0,&52:,5(&2
/7'
8QLJOREXV(OHFWULFDOV ,6 3DUW6HF 7HVWHGZLWK
0HWDOOLFHQFORVXUH & ;; ƒ&
DQG(OHFWURQLFV/7'  $ $SSOLDQFH

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 46 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 41 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

The codes above have the following meaning:

A - The component is replaceable with another one, also certified, with equivalent characteristics.
B - The components is replaceable if authorised by the test house.
C - Integrated component tested together with the appliance.
D - Alternative component
- The conformity certificate of critical components mentioned above have been verified by lab and found satisfactory.
- (#) No IEC standard available

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 47 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 42 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

ANNEX 2: Requirement + Test Verdict


screw terminals (part of the luminaire) N/A
Clause No Test/Requirements name Test Result/Ovservation N/A
(14) SCREW TERMINALS N/A

No such screw terminal block


(14.2) Type of terminal : --
used
Rated current (A) : As above --
(14.3.2.1) One or more conductors: As above N/A
(14.3.2.2) Special preparation As above N/A
(14.3.2.3) Terminal size As above N/A
Cross-sectional area (mm²) : As above N/A
(14.3.3) Conductor space (mm) : As above N/A
(14.4) Mechanical tests N/A
(14.4.1) Minimum distance As above N/A
(14.4.2) Cannot slip out As above N/A
(14.4.3)) Special preparation As above N/A
(14.4.4) Nominal diameter of thread (metric ISO thread) As above N/A
External wiring As above N/A
No soft metal As above N/A
14.4.5) Corrosion As above N/A
(14.4.6) Nominal diameter of thread (mm) : As above N/A
Torque (Nm) : As above N/A
(14.4.7) Between metal surfaces As above N/A
Lug terminal As above N/A
Mantle terminal As above N/A
Pull test; pull (N) : As above N/A
(14.4.8) Without undue damage As above N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 48 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 43 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

ANNEX 3: screwless terminals (part of the luminaire) N/A


(15) SCREW TERMINALS N/A
No such Screw less terminals
(15.2) Type of terminal : --
used
Rated current (A) : As above --
(15.3.1) Material As above N/A
(15.3.2) Clamping As above N/A
(15.3.3) Stop As above N/A
(15.3.4) Unprepared conductors As above N/A
(15.3.5) Pressure on insulating material As above N/A
(15.3.6) Clear connection method As above N/A
15.3.7) Clamping independently As above N/A
(15.3.8) Fixed in position As above N/A
(15.3.10) Conductor size As above N/A
Type of conductor As above N/A
(15.5) Terminals and connections for internal wiring N/A
(15.5.1) Mechanical tests N/A
(15.5.1.1.1) Pull test spring-type terminals (4 N, 4 samples)….: As above N/A
(15.5.1.1.2) Pull test pin or tab terminals (4 N, 4 samples)……: As above N/A
Insertion force not exceeding 50 N As above N/A
(15.5.1.2) Permanent connections: pull-off test (20 N) As above N/A
(15.6) Electrical tests N/A
Voltage drop (mV) after 1 h (4 samples) : As above N/A
Voltage drop of two inseparable joints As above N/A
Number of cycles : As above N/A
Voltage drop (mV) after 10th alt. 25th cycle (4
As above N/A
samples) :
Voltage drop (mV) after 50th alt. 100th cycle (4
As above N/A
samples) :
After ageing, voltage drop (mV) after 10th alt. 25th
As above N/A
cycle (4 samples)
After ageing, voltage drop (mV) after 50th alt. 100th
As above N/A
cycle (4 samples) :
15.7) Terminals external wiring As above N/A
Terminal size and rating As above N/A
Pull test spring-type terminals or welded connections
(15.8.1) As above N/A
(4 samples); pull (N) :
Pull test pin or tab terminals (4 samples); pull (N) : As above N/A
(15.9) Contact resistance test N/A
Voltage drop (mV) after 1 h N/A

Voltage drop of two inseparable joints

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 49 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 44 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Voltage drop after 10th alt. 25th cycle N/A


Max. allowed voltage drop (mV) : N/A

Voltage drop after 50th alt. 100th cycle N/A


Max. allowed voltage drop (mV) : N/A

Continued ageing: voltage drop after 10th alt. 25th cycle N/A
Max. allowed voltage drop (mV) : N/A

Continued ageing: voltage drop after 50th alt. 100th cycle N/A
Max. allowed voltage drop (mV) : N/A

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 50 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 45 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Attachment-1
IP Test sheet as per clause 9 of IS 10322 (Part 1):2014
Cl.
Test / Requirement name Code Test result/ observation Verdict
No.
9 RESISTANCE TO DUST AND MOISTURE See below P
If IP > IP 20 the order of tests as specified in clause
IP 67 P
9.2
Tests for ingress of dust, solid objects and
9.2 See below P
moisture:
-classification according to IP.......: IP 67 P
Independent LED Driver mounted and wired as in
-mounting position during test.....: P
normal use and placed in most unfavourable condition
-fixing screws tightened; torque (Nm)......: Enclosure fixing screw:2.16, 0.26 Nm P
tests according to clauses..........: In compliance P
electric strength test afterwards In compliance P
a)no deposit in dust-proof control gear No such construction used N/A
b)no talcum in dust tight control gear In compliance P
c)no trace of water on current-carrying parts or on
In compliance P
insulation where it could become a hazard
d)i) For control gear without drain holes – no water
In compliance P
entry
d)ii) For control gear with drain holes – no
No such construction used N/A
hazardous water entry
e) no water in watertight control gear In compliance P
f) no contact with live parts (IP 2X) No such construction used N/A
g) no entry into enclosure (IP 3X and IP4X) No such construction used N/A
h) no contact with live parts (IP3X and IP4X) No such construction used N/A
Certificate: It is certified that the above tests were performed and found to be passing in the requirement tested.

(Approving Authority)

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 51 of 52 Group-Lamps, luminaries & accessories
URS PRODUCTS AND TESTING PRIVATE LIMITED
F-3, Sector-6 Noida-201301
T +91 (120) 4516264-65
E [email protected] W www.urs-labs.com
CIN NO U21014UP1987PTC008956

Report No- SC24EPI01632_1 Page 46 of 46


IS 15885 (Part 2/Sec13): 2012+A1:2015
Dated : 29/02/2024

Attachment – 2 Photo document

Sample Front View

Sample Back View

Potted View

TRF No. BIS_LEDCONTROLGEAR_IS 15885-2-13_V1.1


Discipline-Electrical Testing ULR- TC646824000001461F
Page 52 of 52 End of Report Group-Lamps, luminaries & accessories