0% found this document useful (0 votes)
146 views12 pages

Puritan Bennett 980 Ventilator Intensive Care Unit Interactive Brochure

Uploaded by

mohammed alolfe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
146 views12 pages

Puritan Bennett 980 Ventilator Intensive Care Unit Interactive Brochure

Uploaded by

mohammed alolfe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

In the ICU,

every breath
counts.
Get to know the
Puritan Bennett™ 980
ventilator.
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features
A company you can trust for critical moments
Time in the ICU is made up of life-defining moments. Moments to monitor, intervene, and help optimize
Product design outcomes with respiratory technology supporting your critically ill patients. Our portfolio of respiratory
intervention technology and services is ready to help you through those moments.
Software

About us Partnerships
Safety features Helping your patients breathe. It's as simple as that, We’re proud of the partnerships we’ve built with
and it's at the core of what we do. See how we can other leaders in the ventilation space. See how we’re
Our service help enable your patients to breathe more naturally† working with them to ensure every patient gets the
with the Puritan Bennett™ 980 ventilator. Using some breath they need.
of the most innovative breath delivery technology
Product portfolio Watch the video
available means you're able to give your patients
the best during their ICU stay.

†Compared to conventional mechanical ventilation (VC,VC+, PC, PS). 2


Puritan Bennett™ 980 ventilator series

About us

71%
In the ICU
1

Product features
of ICU patients show
Product design Peace of mind in the ICU signs of agitation at
least once during
A stay in the ICU can be unsettling for your patients —
their ICU stay.
Software
especially when mechanical ventilation is required.
Conventional modes of ventilation can cause
added stress and agitation as they can't always
Safety features match your patients' breathing patterns. Clinicians
may respond by increasing sedation in an effort to
Our service alleviate agitation in patients. But this can result in an
increased incidence of delirium, which can lead to
longer ventilation dependency.1
Product portfolio
The Puritan Bennett™ 980 ventilator offers a better
option for your ventilated patients.

3
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features
Chosen by clinicians, like you Backed by data
Selecting the right equipment for the The Puritan Bennett™ ventilator's
Product design
ICU is critical to provide the best care for PAV+™ software is designed to put
your patients. The Puritan Bennett™ 980 the patient in control of the start and
Software ventilator offers: end of every breath, engage and
• Screen configurability strengthen the respiratory muscles,
Safety features and minimize the adverse effects
• Hot-swappable batteries of patient-ventilator asynchrony
• Expiratory filtration system compared to pressure support
Our service ventilation (PSV).3-5
• Connectivity
More details Benefits include:4-9
Product portfolio
• Improved weaning success
• Reduced time of mechanical
ventilation
• Fewer intubations
• Lower ICU cost of care

4
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features See what makes us stand out


Screen configurability Hot-swappable batteries
Product design
• See as much or as little • Easily change batteries
information as you need without interrupting your
Software
• Configure to your patient's ventilation
patients' needs or to
Safety features match your workflow Connectivity
• Access different graph • Provides multiple USB ports
Our service and loop layouts for connections to external
drives and an HDMI output port
Product portfolio Expiratory filtration system that can be used to project the
• Filters the patient's touchscreen externally
exhaled gas before it • Offers options for connecting to
enters the room external data systems
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features

Product design
Smarter ventilation
Keeping the ventilator in sync with your patient’s breaths is key to improving ventilation
Software
outcomes, patient comfort, and quality of care.

Safety features
Simple and intuitive: Safe and reliable: Smart and adaptive
Our service
• Customizable display • Unique ventilator synchrony tools:
• Intuitive screen navigation assurance feature†
• Adaptable to each patient’s needs
• Integrated expiratory
Product portfolio • Provides the right level of support
filtration system
throughout each breath

†Ventilation Assurance provides for continued ventilatory support using one of three backup ventilation (BUV) strategies, bypassing the fault to maintain an optimal degree of ventilation that can be safely delivered. 6
Puritan Bennett™ 980 ventilator series

About us

In the ICU

18 hours
Product features Smarter software in the ICU 13

Our suite of advanced synchrony tools adapts to each patient’s unique


Product design needs and provides the appropriate level of support throughout the Respiratory muscle
breath, from initiation to completion. See how IE Sync™ software, atrophy begins in as
Leak Sync software, and PAV+™ software can help your patients little as 18 hours.
Software receive the flow and volume they need,10-12 exactly when they need it.
More details
Safety features

Other software products include:


Our service
Noninvasive Bi-level High-flow Respiratory Tube compensation
software software oxygen therapy mechanics software software
Product portfolio
• Integrated tool for • Permits • Integrated to • Monitors key • Helps patient
the management of spontaneous facilitate easy respiratory overcome the
respiratory failure breathing and alternation parameters for work of breathing
• Multiple patient supports biphasic between NIV easy patient status imposed by an
triggering and or airway- and HFO2T assessment artificial airway
cycling modes pressure release • Wide range of
and breath types ventilation for flow for flexibility
available to help extra flexibility in application
with patient
acceptance
7
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features
Type of patient asynchrony Puritan Bennett™ 980 synchrony tools suite

Product design IE Sync™ software Leak Sync software PAV+™ software

Software
Ineffective efforts

Delayed triggering
Safety features
Auto-triggering
Our service
Double-triggering
Product portfolio
Delayed cycling

Early cycling

Flow asynchrony
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features

Product design
Added safety in the ICU
Software
Protect your patients from the unexpected.

Safety features Unique ventilation Standby mode Status display


assurance † • Pauses ventilation and • Provides redundant
preserves settings when check of ventilator
Our service • Ensures continued
a patient is disconnected operation
ventilation even if there
is a system failure • Auto-detects the patient
Product portfolio
upon reconnection
• Resumes ventilation
without the need to
push additional buttons

†Ventilation Assurance provides for continued ventilatory support using one of three backup ventilation (BUV) strategies, bypassing the fault to maintain an optimal degree of ventilation that can be safely delivered. 9
Puritan Bennett™ 980 ventilator series

About us

In the ICU
Service and support at every step
Product features Our Service team provides expertise, delivered
without compromise. We’re here for you and your
critical care equipment, anytime — 24/7/365. And
Product design
like you, we understand that capital equipment is
more than a purchase — it’s a lifecycle investment.
Software Our trusted service partnership includes:
• Customizable service offerings from
Safety features comprehensive to shared service
• Demonstrated economic value through
Our service our service agreements
• Tracking maintenance schedules and
Product portfolio managing OEM parts inventory
• Local support with engineers supporting
all 50 states
• Field service engineer customer satisfaction
averages 9.8 out of 10.14

10
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features

Product design
Explore the portfolio DAR™ filters

Software
• Acute care ventilation
• Intubation
Safety features • Tracheostomy
• Ventilator filters
Our service • Video laryngoscopy Shiley™ Puritan Bennett™ cuff
tracheostomy tubes pressure manager
• Active humidification
Puritan Bennett™
Product portfolio • Automatic cuff pressure management 980 ventilator
• NICU ventilation

Shiley™ McGRATH™ MAC


endotracheal tubes video laryngoscope

11
Puritan Bennett™ 980 ventilator series

About us

In the ICU

Product features Get started today


Contact us
Product design medtronic.com

Software

Safety features
Please pay close attention to warnings and their associated consequences as described in the Puritan Bennett™ 980 ventilator operator’s manual.

The ventilator system is not intended to be a comprehensive monitoring device and does not activate alarms for all types of conditions. Do not operate the ventilator in a magnetic resonance imaging (MRI) environment.
Our service Risks associated with using a mechanical ventilator include but are not limited to hypoxemia, hypercarbia, hypocarbia, and infection.

Product portfolio
1. Siegel MD. Management of agitation in the intensive care unit. Clin Chest Med. 2003:24(4):713 -725.
2. Bosma KJ, Read BA, Bahrgard Nikoo MJ, Jones PM, Priestap FA, Lewis JF. A Pilot Randomized Trial Comparing Weaning From Mechanical Ventilation on Pressure Support Versus Proportional Assist Ventilation. Crit Care Med. Jun 2016;44(6):1098-108.
3. Schmidt M, Kindler F, Cecchini J, Poitou T, Morawiec E, Persichini R, Similowski T, Demoule A. Neurally adjusted ventilatory assist and proportional assist ventilation both
4. Kataoka J, Kuriyama A, Norisue Y, Fujitani S. Proportional modes versus pressure support ventilation: a systematic review and meta-analysis. Ann Intensive Care. Dec 102018;8(1):123. doi:10.1186/s13613-018-0470-y
5. Jhou HJ, Chen PH, Ou-Yang LJ, Lin C, Tang SE, Lee CH. Methods of Weaning From Mechanical Ventilation in Adult: A Network Meta-Analysis. Front Med (Lausanne). 2021;8:752984. doi:10.3389/fmed.2021.752984
6. Kampolis CF, Mermiri M, Mavrovounis G, Koutsoukou A, Loukeri AA, Pantazopoulos I. Comparison of advanced closed-loop ventilation modes with pressure support ventilation for weaning from mechanical ventilation in adults: A systematic review
and meta-analysis. J Crit Care. Nov 252021;68:1-9. doi:10.1016/j.jcrc.2021.11.010
7. Ou-Yang LJ, Chen PH, Jhou HJ, Su VY, Lee CH. Proportional assist ventilation versus pressure support ventilation for weaning from mechanical ventilation in adults: a meta-analysis and trial sequential analysis. Crit Care. Sep 142020;24(1):556.
doi:10.1186/s13054-020-03251-4
8. Saunders R, Davis JA, Bosma KJ. Proportional-assist ventilation with load-adjustable gain factors for mechanical ventilation: a cost-utility analysis. CMAJ Open. Jan-Mar 2022;10(1):E126-e135. doi:10.9778/cmajo.20210078
9. Saunders R, Geogopoulos D. Evaluating the Cost-Effectiveness of Proportional-Assist Ventilation Plus vs. Pressure Support Ventilation in the Intensive Care Unit in Two Countries. Front Public Health. 2018;6:168. doi:10.3389/fpubh.2018.00168
10. Xirouchaki N, Kondili E, Vapoidi K, et al. Proportional assist ventilation with load-adjustable gain factors in critically ill patients: comparison with pressure support. Int Care Med. 2008;34:2026 -2034.
11. Xirouchaki N, Kondili E, Klimathianaki M, Georgopoulos D. Is proportional assist ventilation with load-adjustable gain factors a user-friendly mode? Int Care Med. 2009;35:1599 -1603.
12. Costa R, Spinazzola G, Cipriani F, et al. A physiologic comparison of proportional assist ventilation with load-adjustable gain factors (PAV+) versus Pressure Support Ventilation (PSV). Int Care Med. 2011;37:1494 -1500.
13. Levine S, Nguyen T, Taylor N, et al. Rapid disuse atrophy of diaphragm fibers in mechanically ventilated humans. N Engl J Med. 2008;358(13):1327 -1335.
14. Service 800 survey data 4/2021 -3/2022. Used with permission.

©2023 Medtronic. Medtronic, Medtronic logo, and Engineering the extraordinary are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. 04/2023-US-RE-2300017–[WF# 8222170].

6135 Gunbarrel Avenue


Boulder, CO 80301 800.635.5267

You might also like