GENERAL KEY PLAN: N


VJA-PS-ME Review: (01-11-2024):
L A
QIB
Refer to the comments in the drawing no. 14-293000-4800001025-GEO-FLS-DRG-100102

DN
DN
DN

NOTES:
4 5
1. THIS DRAWING IS THE COPYRIGHT OF GEO.THIS DRAWING OR ANY
PORTION OF IT MAY NOT BE REPRODUCED IN ANY WAY WITHOUT
THE CONSENT OF GEO.
2. DIMENSIONS ARE NOT TO BE SCALED FROM THIS DRAWING.
3. DIMENSIONS ARE IN MILLIMETERS, UNLESS NOTED OTHERWISE.
4. THE CONTRACTOR IS TO VERIFY ALL DIMENSION ON SITE BEFORE
EXECUTING THE SITE.
5. ANY DISCREPANCIES, EITHER BETWEEN WRITTEN DIMENSIONS AND
SITE DIMENSIONS OR BETWEEN THIS DRAWING AND OTHER
300x200 EAD
1A
1A CONSULTANT'S OR SUPPLIER'S DRAWINGS SHOULD BE BROUGHT
162 L/S - T/B
ACRT-FF-02 TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BEFORE
EXECUTING THE WORKS.
6. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE
D Male Toilets
1.1.04 FCU-FER-FF-01A 300x200 FAD RELEVANT STRUCTURAL, MECHANICAL& ELECTRICAL DRAWINGS
189 L/S - F/B
Female Toilets
5 m²
AND SPECIFICATIONS.
1.1.03
6 m² 7. ALL WORKS ARE TO BE CARRIED OUT IN ACCORDANCE WITH THE
RELEVANT CODES OF PRACTICE AND ALSO TO MEET THE LOCAL
AUTHORITY REQUIREMENTS.
Corridor
1.1.02
4 m²

Personal Elevator
1.0.73
8 m²

Reception
1.1.01
161 m²

Electrical Room
1.0.18
8 m² Personal Elevator
1.0.74
8 m²

1B
1B
C

FCU-FER-FF-01B

Stair 07
1.0.79
14 m²

REFERENCE NUMBER DESCRIPTION


14-293000-4800001025-GEO-FLS-DRG-100108 First Floor - Fermentation Facility

0m 2m 4m 6m 8m 10m

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
VISUAL SCALE 1:100 @ A0
STAGE:

Personal Elevator\Hygiene
3A
1.0.75
8 m²

A STAGE 3A - CONCEPT DESIGN AH 09.10.24


REV DESCRIPTION APP DATE
PURPOSE OF ISSUE:

FOR REVIEW AND APPROVAL


CLIENT: PROJECT MANAGEMENT CONSULTANT:

B
Personal Elevator\Hygiene
1.0.76
8 m²
1C
1C

LEGENDS AND ABBREVIATION DESIGN CONSULTANT NAME & LOGO (s):


F/A FROM ABOVE
T/B TO BELOW
FAD FRESH AIR DUCT
EAD EXTRACT AIR DUCT
SAD SUPPLY AIR DUCT
First Floor - Fermentation Facility -Ventilation Layout - RAD RETURN AIR DUCT
SAD - SUPPLY AIR DUCT
1 Dependent 1 RAD - RETURN AIR DUCT
14-293000-4800001025-GEO-FLS-DRG-100108 SCALE: 1 : 50 FAD - FRESH AIR DUCT DESIGN CONSULTANT (GEO) NEOM'S REVIEW:
C:\Users\tajmal\Documents\14-293000-4800001025-GEO-HVC-MDL-000001_tajmal.rvt

EAD - EXTRACT AIR DUCT DRAWN: TA 09.10.24


CHILLED WATER SUPPLY PIPE CHECKED: LH 09.10.24 CHECKED: NEOM DD.MM.YY
CHILLED WATER RETURN PIPE
APPROVED: AH 09.10.24 APPROVED: NEOM DD.MM.YY
RD-SD ROUND SUPPLY CEILING DIFFUSER
SD - SUPPLY SQUARE CEILING DIFFUSER
SCALE: 1:50 SHEET SIZE: A0
RD - RETURN SQUARE CEILING DIFFUSER
DV - DISC VALVE - TOILET EXTRACT DISCIPLINE NAME:
BELL MOUTH DUCT Fire Life & Safety
MVCD - MOTORIZED VOLUME CONTROL DAMPER
T THERMOSTAT First Floor - Ventilation Layout
SA - SOUND ATTENUATOR
VCD - VOLUME CONTROL DAMPER Fermentation Facility
NRD - NON RETURN DAMPER
PROJECT NAME:
FD - FIRE DAMPER

A
FLEXIBLE CONNECTION Design Of Bioreactor Park
WALL OPENING
SG-SUPPLY LINEAR BAR GRILLE-SIDE THROW
RG-RETURN LINEAR BAR GRILLE-SIDE THROW OXAGON 14-Outer Region
EXTRACT AIR LOUVER
INTAKE AIR LOUVER
NEOM
EXTRACT/MAKEUP FAN
AIR CURTAIN
KINGDOM OF SAUDI ARABIA
REGION ASSET CODE CONTRACT CODE
FCU-00-00 FAN COIL UNIT - DUCTED

14 293000 4800001025
10/17/2024 11:54:23 AM

AIR HANDLING UNIT


FRESH AIR HANDLING UNIT
DX - DECORATIVE WALL MOUNTED UNIT
DRAWING NUMBER
DX - CONDENSING UNIT ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

GEO FLS DRG 100108 A