1 2 3 4 5 6

GENERAL KEY PLAN: N

L A
QIB

VJA-PS-ME Review: (01-11-2024):


DN
Refer to the comments in the drawing no. 14-293000-4800001025-GEO-FLS-DRG-100102 DN
DN

12
12 13
13

2A
2A
ACRT-FF-04

NOTES:

1. THIS DRAWING IS THE COPYRIGHT OF GEO.THIS DRAWING OR ANY


PORTION OF IT MAY NOT BE REPRODUCED IN ANY WAY WITHOUT
THE CONSENT OF GEO.
2. DIMENSIONS ARE NOT TO BE SCALED FROM THIS DRAWING.
3. DIMENSIONS ARE IN MILLIMETERS, UNLESS NOTED OTHERWISE.
Reception
4. THE CONTRACTOR IS TO VERIFY ALL DIMENSION ON SITE BEFORE
FCU-CUL-FF-01B
2.1.01
186 m² EXECUTING THE SITE.
FCU-CUL-FF-01A 5. ANY DISCREPANCIES, EITHER BETWEEN WRITTEN DIMENSIONS AND
SITE DIMENSIONS OR BETWEEN THIS DRAWING AND OTHER
CONSULTANT'S OR SUPPLIER'S DRAWINGS SHOULD BE BROUGHT
TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BEFORE
EXECUTING THE WORKS.
6. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE
D RELEVANT STRUCTURAL, MECHANICAL& ELECTRICAL DRAWINGS
AND SPECIFICATIONS.
7. ALL WORKS ARE TO BE CARRIED OUT IN ACCORDANCE WITH THE
RELEVANT CODES OF PRACTICE AND ALSO TO MEET THE LOCAL
AUTHORITY REQUIREMENTS.
3A
FCU-CUL-FF-02 FCU-CUL-FF-03

Visitor Meeting Room


2.1.11
20 m²
Visitor Meeting Room
2.1.10
21 m²
2B
2B

Personal Elevator
2.0.138
6 m²

C 3B Corridor
2.1.05
11 m²

Janitor
2.1.09
4 m²

Personal Elevator
2.0.137
6 m²

Personal Elevator Lobby


2.1.02
86 m²
Women Toilets
2.1.08

Handicap Toilet
2.1.07
8 m²
REFERENCE NUMBER DESCRIPTION
Male Toilets
2.1.06
5 m²
14-293000-4800001025-GEO-FLS-DRG-100107 First Floor - Cultured Facility
9 m²
FCU-CUL-FF-04

0m 2m 4m 6m 8m 10m

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
VISUAL SCALE 1:100 @ A0
FCU-CUL-FF-01C
Personal Elevator
STAGE:
2.0.136
6 m²
3A
Electrical Room
2.1.04
25 m²

A STAGE 3A - CONCEPT DESIGN AH 09.10.24


REV DESCRIPTION APP DATE
1000x950 FAD
7397 L/S - F/A PURPOSE OF ISSUE:

FOR REVIEW AND APPROVAL


3C 2C
2C
CLIENT: PROJECT MANAGEMENT CONSULTANT:

MSFD

B
MSFD

450x250 FAD
414 L/S
CCU-CU-FF-05
400x250 EAD 1.24 L/s LEGENDS AND ABBREVIATION DESIGN CONSULTANT NAME & LOGO (s):
374 L/S
F/A FROM ABOVE
950x900 EAD
6572 L/S T/B TO BELOW
F/B
IT Server
2.1.03
FAD FRESH AIR DUCT
47 m²
CCU-CU-FF-05 (DX BACKUP) EAD EXTRACT AIR DUCT
1.24 L/s
SAD SUPPLY AIR DUCT
Stair 03
2.0.135
19 m²
RAD RETURN AIR DUCT
SAD - SUPPLY AIR DUCT
RAD - RETURN AIR DUCT
FAD - FRESH AIR DUCT DESIGN CONSULTANT (GEO) NEOM'S REVIEW:
C:\Users\tajmal\Documents\14-293000-4800001025-GEO-HVC-MDL-000001_tajmal.rvt

EAD - EXTRACT AIR DUCT DRAWN: TA 09.10.24


CHILLED WATER SUPPLY PIPE CHECKED: LH 09.10.24 CHECKED: NEOM DD.MM.YY
CHILLED WATER RETURN PIPE
APPROVED: AH 09.10.24 APPROVED: NEOM DD.MM.YY
RD-SD ROUND SUPPLY CEILING DIFFUSER
SD - SUPPLY SQUARE CEILING DIFFUSER
SCALE: 1:50 SHEET SIZE: A0
RD - RETURN SQUARE CEILING DIFFUSER
DV - DISC VALVE - TOILET EXTRACT DISCIPLINE NAME:
BELL MOUTH DUCT Fire Life & Safety
MVCD - MOTORIZED VOLUME CONTROL DAMPER
T THERMOSTAT First Floor - Ventilation Layout
SA - SOUND ATTENUATOR
VCD - VOLUME CONTROL DAMPER Cultured Facility
NRD - NON RETURN DAMPER
PROJECT NAME:
First Floor - Cultured Facility - Ventilation Layout - FD - FIRE DAMPER
FLEXIBLE CONNECTION Design Of Bioreactor Park
A
1 Dependent 1 WALL OPENING
SG-SUPPLY LINEAR BAR GRILLE-SIDE THROW
14-293000-4800001025-GEO-FLS-DRG-100107 SCALE: 1 : 50
RG-RETURN LINEAR BAR GRILLE-SIDE THROW OXAGON 14-Outer Region
EXTRACT AIR LOUVER
INTAKE AIR LOUVER
NEOM
EXTRACT/MAKEUP FAN
AIR CURTAIN
KINGDOM OF SAUDI ARABIA
REGION ASSET CODE CONTRACT CODE
FCU-00-00 FAN COIL UNIT - DUCTED

14 293000 4800001025
10/17/2024 11:54:16 AM

AIR HANDLING UNIT


FRESH AIR HANDLING UNIT
DX - DECORATIVE WALL MOUNTED UNIT
DRAWING NUMBER
DX - CONDENSING UNIT ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

GEO FLS DRG 100107 A


NEOM-NEN-PRC-009_TMP12_02.00