X-gateway™

The Anybus X-gateway family consists of over 200 proven,


robust and ready-to-use gateways aimed to connect almost
every possible combination of two industrial networks.

Anybus X-gateway allows system integrators to easily transfer


I/O data between devices on two different PLC systems and
networks, enabling a consistent information flow
throughout the entire plant.

Typical Industries
EXAMPLE: FIELDBUS TO ETHERNET EXAMPLE: ETHERNET TO ETHERNET

PLC PLC

EtherNet/IP CC-Link IE Field

X-gateway X-gateway
Int 1. EtherNet/IP Adapter Int 1. CC-Link IE Field Slave
Int 2. Profibus Master Int 2. Profinet Device

PROFIBUS PROFINET
In-short
Anybus X-gateways enable connectivity
between almost any two industrial
networks or PLC systems.

Master versions supporting:


AS-Interface
DeviceNet Features and Benefits Easy Configuration
EtherNet/IP
PROFIBUS
• Simple way to transmit I/O data between any two industrial No programming skills are needed to
networks set up the X-gateway.
Slave versions supporting: • Over 200 different network combinations (master, scanner,
CANopen slave, adapter, I/O device, server) The configuration of the X-gateway is
CC-Link made using the “Anybus Configuration
CC-Link IE Field • Connects different PLC systems (Siemens, Rockwell,
Manager X-gateway” which is
ControlNet Schneider, Mitsubishi, Omron, Beckhoff etc)
included in the price (Windows™
DeviceNet • I/O data transfer with average throughput between networks Tool). You install this on your PC, and
EtherCAT of 10 - 15 ms
EtherNet/IP connect the included USB cable to the
FIPIO • Additional parameter data supported (depending on network configuration port of the X-gateway.
Interbus RS485 + Fiber Optic combination) The Anybus Configuration Manager
J1939* • Optional control and status information added to the I/O data X-gateway is available at
LonWorks for diagnostic purposes www.anybus.com
Modbus Plus
Modbus RTU • Included Anybus OPC server for extended functionality with
The easy-to-use Anybus Configuration
Modbus-TCP Ethernet versions
Manager X-gateway allows you to
PROFIBUS • Anybus master configuration tool included free of charge with a define the I/O data sizes on each
PROFINET IO Profibus, DeviceNet or EtherNet/IP Master/Scanner network side and to define the data
PROFINET IRT Copper + Fibre Optic
• Robust stand-alone housing with CE and UL certifications mapping and separation between
Accessories: • Global free technical support and consultancy cyclic I/O data and parameter data.
Extra Wide DIN-clip for flat mounting
- order number SP1784 • See www.anybus.com for application notes and instruction
videos on how to configure the X-gateways
*available in a different formfactor housing

HMS provides a
full 3 year product
guarantee

Industrial networking made easy! www.anybus.com


TECHNICAL SPECIFICATIONS
Technical Details Standard NETWORK SPECIFIC FEATURES
Weight 400 g, 0,880 lb 1 = Network connector, 2 = Baud rate,
Dimensions (L•W•H) 114•44•127 mm, 4,49•1,73•5,00” 3 = I/O data, 4 = Other, 5 = Amount of slaves / adapters
Protection class IP20, NEMA rating 1
MASTER
Enclosure material Aluminium and plastic
ASI 1 = 2*2p; 5,08 Phoenix Plug 2 = 167 kbit/s 3 = 248/186 (digital input/output)
Installation position Vertical position 4 = ASI version 3.0 5 = 62
Mounting DIN rail (35•7,5/15) EN 50022
DeviceNet 1 = 5*5p; 5.08 Phoenix Plug 2 = 125-500 kbit/s
Certifications 3 = 512 byte IN/OUT 4 = DeviceNet 2.0 scanner 5 = 63
UL File number: E214107 UL 508 Ind. Cont. Eq. EtherNet/IP 1 = RJ45 2 = 10/100 Mbit/s 3 = 509/505 byte IN/OUT
Hazardous Locations CLASS 1, DIVISION 2, GROUPS A, B, C AND D, T4 ANSI/ISA-12.12.01-2000 4 = FTP Server, Web Server, SMTP Client 5 = 64
ATEX Zone 2, Cat 2 EN 60079-15 PROFIBUS 1 = DSUB9F 2 = Up to 12 Mb
EN 60079-11 3 = 512 byte IN/OUT 4 = Profibus DP (IEC 61158) 5 = 125
CE 2004/108/EC EN61000-6-4
EN61000-6-2 SLAVE
Electrical Characteristics CANopen 1 = DSUB9M 2 = Up to 1 Mbit/s
3 = 512 byte IN/OUT 4 = Supports profile CIA DS301 V4.02
Power 24 VDC +/- 20 %
Current consumption Max 400mA at 24VDC, Typical 200 mA at 24VDC CC-Link 1 = 1*5p; 5.08 Phoenix Plug 2 = Up to 10 Mbit/s
3 = 896 IO points, 128 word IN/OUT 4 = Up to 4 occupied stations
Hardware Characteristics
CC-Link IE 1 = 2*RJ45 2 = Up to 1 Gbp/s
Reverse voltage protection Yes
Field 3 = 512 byte IN/OUT 4 = CC-Link IE Field Network intelligent device station
Short circuit protection Yes
ControlNet 1 = 2*BNC Coax + RJ45 (NAP) 2 = 5 Mbit/s
Environmental Characteristics
3 = 450 byte IN/OUT 4 = Communications adapter, profile n. 12
Operating temp -25 to 65 C, -13 to 149 F (for all other networks)
o o
IEC 68-2-1, IEC 68-2-2
-25 to 50 oC, -13 to 122 oF (only for Profinet IRT Fibre Optic) DeviceNet 1 = 1*5p; 5.08 Phoenix Plug 2 = 125-500 kbit/s
3 = 512 byte IN/OUT 4 = Communications adapter, profile n. 12
Storage temp -40 to 85 oC, -40 to 185 oF IEC 68-2-1, IEC 68-2-2
Relative Humidity 5-95 % non condensing IEC 68-2-30 EtherCAT 1 = 2*RJ45 2 = 100 Mbit/s
3 = 512 byte IN/OUT 4 = DS301 V4.02 compliant, 4 FMMU Channels
Installation altitude Up to 2 000 m
EtherNet/IP 1 = 2*RJ45 2 = 10/100 Mbit/s 3 = 509/505 byte IN/OUT
Immunity and Emission for Industrial Environment
4 = EtherNet/IP group 2 and 3 server. Modbus TCP slave functionality
Electrostatic discharge +/- 4 kV EN 61000-4-2
FIPIO 1 = DSUB9M 2 = 1 Mbit/s 3 = 32 words IN/OUT
Electromagnetic RF fields 10 V/m 80 MHz - 1 GHz EN 61000-4-3 4 = Data exchange according to FIPIO Extended Device Profile, Class 0
3 V/m 1,4 GHz - 2,0 GHz
1 V/m 2,0 GHz - 2,7 GHz Interbus 1 = DSUB9F + DSUB9M 2 = 500 kbit/s, 2 Mbit/s
Fast Transients +/- 1 kV EN 61000-4-4 RS485 3 = 20 byte IN/OUT (process data), 512 bytes IN/OUT (with PCP)
4 = PCP V.2.0 (0 or 1 word)
Surge protection +/- 1 kV EN 61000-4-5
Interbus Fibre 1 = HFBR-2505C, HFBR-1505C 2 = 500 kbit/s, 2 Mbit/s
RF conducted interference 10 V/rms EN 61000-4-6
Optic 3 = 20 byte IN/OUT (process data), 512 bytes IN/OUT (with PCP)
Emission (at 3 m) 50 dB 30 MHz - 230 MHz EN 55016-2-3 4 = IEC874-2 and DIN47258
57 dB 30 MHz - 1 GHz
J1939 1 = 1*5p; 5.08 Phoenix Plug (Profibus / EtherNet/IP / Modbus-TCP) DSUB15M
Single Pack Accessories
(Modbus RTU) 2 = - 3 = 2048 bytes IN/OUT (Modbus RTU), 248-500
• Configuration Cable (USB) • Installation sheet 24 VDC power supply (EtherNet/IP), Modbus TCP 499/495 bytes Profibus 4 = SAEJ1939
Network connector 1
2-pole Phoenix plug 1 = 1*5p; 5.08 Phoenix Plug 2 = 78 kbit/s 3 = 256 network variables in/out
LonWorks
4 = Lonmark objects handling
Plastic ends
Modbus Plus 1 = DSUB9F 2 = 1 Mbit/s 3 = 32 words IN/OUT (global data)
4 = Modbus Plus Host Firmware Rev. 77

Modbus RTU 1 = DSUB9F 2 = 1,2-57,6 kbit/s 3 = 256 registers in each direction


4 = RS232 and RS485
DIN-rail mounting
LED indicators Modbus TCP 1 = 2*RJ45 2 = 10/100 Mbit/s 3 = 512 byte IN/OUT
4 = Supports EtherNet/IP

PROFIBUS 1 = DSUB9F 2 = Up to 12 Mbit/s


Rugged aluminium housing 3 = Up to 244 bytes data using DP / Up to 512 bytes using DPV1 (Max 344 bytes
in+out) 4 = Profibus DP (IEC 61158)

PROFINET-IO 1 = RJ45 2 = 10/100 Mbit/s 3 = 512 byte IN/OUT


USB Type B 4 = RT Communication and Cyclic data exchange
configuration port
PROFINET IRT 1 = 2*RJ45 2 = 100 Mbit/s 3 = 220 byte IN/OUT
Network connector 2
Plastic ends 4 = RT Communication and integrated IRT switch functionality

PROFINET IRT 1 = 2*SC-RJ FO connectors 2 = 100 Mbit/s 3 = 220 byte IN/OUT


Fibre Optics 4 = RT Communication and integrated IRT switch functionality

HMS Industrial Networks - Worldwide


HMS - Sweden (HQ) HMS - France HMS - Italy HMS - United States
Tel : +46 (0)35 17 29 00 (Halmstad HQ) Tel: +33 (0)368 368 034 Tel : +39 039 59662 27 Tel: +1 312 829 0601
Tel: + 46 (0)35 17 29 24 (Västerås office) E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
E-mail: [email protected]
HMS - China HMS - Germany HMS - Japan
Tel : +86 10 8532 1188 Tel: +49 721 989777-000 Tel: +81 (0)45 478 5340
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
HMS - Denmark HMS - India HMS - UK
Tel: +45 35 38 29 00 Tel: +91 20 2563 0211 Tel: +44 (0) 1926 405599
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]

Anybus® is a registered trademark of HMS Industrial Networks AB, Sweden, USA, Germany and other countries. Other marks and words belong to their respective companies.
All other product or service names mentioned in this document are trademarks of their respective companies.
Part No: MMA201 Version 4 04/2014 - © HMS Industrial Networks - All rights reserved - HMS reserves the right to make modifications without prior notice.

Industrial networking made easy! www.anybus.com


www.anybus.com
Anybus X-gateway INTERFACE #2
Anybus X-gateway Ethernet PROFINET-IO EtherCAT CC-Link IE Field PROFIBUS Modbus RTU ControlNet Interbus Slave Interbus Slave Modbus Plus PROFINET IRT PROFINET IRT
Part number and price Ethernet/IP slave DeviceNet Slave CANopen Slave CC Link J1939*** LONWorks FIP Slave
MBTCP slave slave slave slave** Slave slave Slave Cu Fo Slave slave Cu slave Fo
group Selection Matrix
PROFIBUS Master AB7800 B AB7629 B AB7646 B AB7696 B AB7953 B AB7801 B AB7802 B AB7807 B AB7808 B AB7810 B n.a. - n.a. - AB7803 C AB7804 C AB7805 C AB7806 C AB7809 C n.a. - n.a. -
AB7916


DeviceNet Master AB7607*** B C AB7630 B AB7647 B AB7697 B AB7955 B AB7663 B AB7811 B AB7816 B AB7817 B AB7819 B n.a. - n.a. - AB7812 C AB7813 C AB7814 C AB7815 C AB7818 C n.a. - n.a. -
ASI Master AB7820 B AB7631 B AB7648 B AB7698 B n.a. - AB7821 B AB7822 B AB7827 B AB7828 B AB7830 B n.a. - n.a. - AB7823 C AB7824 C AB7825 C AB7826 C AB7829 C n.a. - n.a. -
Ethernet/IP Master AB7668 B AB7669 B AB7670 B AB7699 B AB7957 B AB7671 B AB7672 B AB7677 B AB7678 B AB7680 B n.a. - n.a. - AB7673 C AB7674 C AB7675 C AB7676 C AB7679 C n.a. - n.a. -
Anybus X-gateway INTERFACE #1

CANopen Master AB7306 * AB7308 * AB7307 * AB7300 * n.a. - AB7301 * AB7302 * AB7304 * AB7305 * n.a. - n.a. - n.a. - AB7303 * n.a. - n.a. - n.a. - n.a. - AB7309 * n.a. -
Modbus MBTCP Master AB9006 * AB9008 * AB9007 * AB9000 * n.a. - AB9001 * AB9002 * AB9004 * AB9005 * AB9009 * n.a. - n.a. - AB9003 * n.a. - n.a. - n.a. - n.a. - n.a. - n.a. -
Ethernet/IP slave AB7831 A AB7632 A AB7649 A AB7682 A AB7956 A AB7832 A AB7833 A AB7838 A AB7839 A AB7841 A AB7665 A AB7842 C AB7834 C AB7835 C AB7836 C AB7837 C AB7840 C AB7942 C n.a. -
Ethernet MBTCP slave AB7632 A AB7633 A AB7650 A AB7901 A AB7958 A AB7634 A AB7635 A AB7640 A AB7641 A AB7643 A AB7665 A AB7644 C AB7636 C AB7637 C AB7638 C AB7639 C AB7642 C n.a. - n.a. -
PROFINET IO slave AB7649 A AB7650 A AB7651 A AB7684 A AB7954 A AB7652 A AB7653 A AB7658 A AB7659 A AB7661 A n.a. - AB7662 C AB7654 C AB7655 C AB7656 C AB7657 C AB7660 C n.a. - n.a. -
EtherCAT slave AB7682 A AB7901 A AB7684 A AB7900 A AB7961 A AB7685 A AB7686 A AB7691 A AB7692 A AB7694 A n.a. - AB7695 C AB7687 C AB7688 C AB7689 C AB7690 C AB7693 C n.a. - n.a. -
CC-Link IE Field slave** AB7956 A AB7958 A AB7954 A AB7961 A n.a. - AB7959 A AB7960 A AB7963 A AB7964 A n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. -
PROFIBUS Slave AB7832 A AB7634 A AB7652 A AB7685 A AB7959 A AB7843 A AB7844 A AB7849 A AB7850 A AB7852 A AB7615 A AB7853 C AB7845 C AB7846 C AB7847 C AB7848 C AB7851 C AB7913 C AB7944 C
DeviceNet Slave AB7833 A AB7635 A AB7653 A AB7686 A AB7960 A AB7844 A AB7854 A AB7859 A AB7860 A AB7862 A n.a. - AB7863 C AB7855 C AB7856 C AB7857 C AB7858 C AB7861 C AB7940 C n.a. -
CANopen Slave AB7838 A AB7640 A AB7658 A AB7691 A AB7963 A AB7849 A AB7859 A AB7894 A AB7895 A AB7897 A n.a. - AB7898 C AB7868 C AB7876 C AB7883 C AB7889 C AB7896 C AB7915 C AB7943 C
Modbus RTU slave AB7839 A AB7641 A AB7659 A AB7692 A AB7964 A AB7850 A AB7860 A AB7895 A AB7899 A AB7621 A AB7612 A See AB7009 - AB7869 C AB7877 C AB7884 C AB7890 C AB7620 C n.a. - n.a. -
CC Link slave AB7841 A AB7643 A AB7661 A AB7694 A n.a. - AB7852 A AB7862 A AB7897 A AB7621 A AB7626 A n.a. - AB7627 C AB7871 C AB7879 C AB7886 C AB7892 C AB7624 C n.a. - n.a. -
J1939*** AB7665 A AB7665 A n.a. - n.a. - n.a. - AB7615 A n.a. - n.a. - AB7612 A n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. -
LONWorks AB7842 C AB7644 C AB7662 C AB7695 C n.a. - AB7853 C AB7863 C AB7898 C See AB7009 - AB7627 C n.a. - AB7628 C AB7872 C AB7880 C AB7887 C AB7893 C AB7625 C n.a. - n.a. -
n.a. n.a.

Industrial networking made easy!


ControlNet Slave AB7834 C AB7636 C AB7654 C AB7687 C - AB7845 C AB7855 C AB7868 C AB7869 C AB7871 C - AB7872 C AB7864 C AB7865 C AB7866 C AB7867 C AB7870 C AB7941 C n.a. -
FIP Slave AB7835 C AB7637 C AB7655 C AB7688 C n.a. - AB7846 C AB7856 C AB7876 C AB7877 C AB7879 C n.a. - AB7880 C AB7865 C AB7873 C AB7874 C AB7875 C AB7878 C n.a. - n.a. -
Interbus Slave Cu AB7836 C AB7638 C AB7656 C AB7689 C n.a. - AB7847 C AB7857 C AB7883 C AB7884 C AB7886 C n.a. - AB7887 C AB7866 C AB7874 C AB7881 C AB7882 C AB7885 C AB7914 C n.a. -
Interbus Slave Fo AB7837 C AB7639 C AB7657 C AB7690 C n.a. - AB7848 C AB7858 C AB7889 C AB7890 C AB7892 C n.a. - AB7893 C AB7867 C AB7875 C AB7882 C AB7888 C AB7891 C n.a. - n.a. -
Modbus plus AB7840 C AB7642 C AB7660 C AB7693 C n.a. - AB7851 C AB7861 C AB7896 C AB7620 C AB7624 C n.a. - AB7625 C AB7870 C AB7878 C AB7885 C AB7891 C AB7623 C n.a. - n.a. -
PROFINET IRT slave Cu AB7942 C n.a. - n.a. - n.a. - n.a. - AB7913 C AB7940 C AB7915 C n.a. - n.a. - n.a. - n.a. - AB7941 C n.a. - AB7914 C n.a. - n.a. - AB7962** C n.a. -
PROFINET IRT slave Fo n.a - n.a. - n.a. - n.a. - n.a. - AB7944 C n.a. n.a. AB7943 C n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. - n.a. -
Please note: There are three price groups for Anybus X-gateways. The correct price group is indicated to the right of each part number (price group A, B and C). Go to the Networking Products Pricelist to get the prices A, B and C.
The abbreviation "n.a." indicates that the product is currently not available in the standard Anybus product offer from HMS.
* X-gateway CANopen and Modbus TCP have a dfferent pricelist.
** X-gateway CC-Link IE Field and other new combinations are only available in the new X-gateway release with revision -F from Q2-2014.
*** X-gateway J1939 and AB7607 are not included in the new X-gateway release and will remain unchanged.