Subject C Topic I PNS BAFS PABES 305 2020 Slaughterhouse Swine
Subject C Topic I PNS BAFS PABES 305 2020 Slaughterhouse Swine
All rights reserved. The mention of specific organizations or products, does not mean
endorsement or recommendation from the Bureau of Agriculture and Fisheries Standards
(BAFS) in preference to other of similar nature that are not included. The BAFS encourages
the reproduction and dissemination of the materials upon request. Applications for permissions
to reproduce or disseminate these materials and all other queries should be addressed to the
publisher.
Published by:
Bureau of Agriculture and Fisheries Standards
BAFS Building, BPI Compound, Visayas Avenue, Diliman, Quezon City
[email protected] | [email protected]
(+632) 8928 8756 to 65 local 3301 – 3325
www.bafs.da.gov.ph
Contents
Annex A......................................................................................................................... 18
Annex B......................................................................................................................... 19
Annex C ........................................................................................................................ 20
Annex D ........................................................................................................................ 23
Annex E......................................................................................................................... 24
Annex F ........................................................................................................................ 25
Annex G ....................................................................................................................... 27
Bibliography .................................................................................................................. 28
PHILIPPINE NATIONAL STANDARD PNS/BAFS PABES 305:2020
Foreword
This edition includes the following significant changes compared to the previous edition:
iii
PHILIPPINE NATIONAL STANDARD PNS/BAFS PABES 305:2020
This Standard cancels and replaces the provisions recommended by PAES 411:2000 –
Agricultural Structures – Slaughterhouse for Swine, Small and Large Animals.
This document was drafted in accordance with the editorial rules of the ISO/IEC
Directives, Part 2.
iv
PHILIPPINE NATIONAL STANDARD PNS/BAFS PABES 305:2020
Agricultural Structures- Slaughterhouse- Swine
1 Scope
This standard specifies the general and structural requirements of a slaughterhouse for
swine. This standard shall:
1.1 provide the general requirements for site selection, design, and construction;
1.3 provide protection and convenience for the slaughterhouse personnel; and
2 Normative References
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
For the purpose of this standard, the following terms and definitions shall apply.
3.1
bleeding
process of removing as much blood as possible from the slaughtered swine before further
processing
PNS/BAFS PABES 305:2020
3.2
carcass
body of any slaughtered animal after bleeding and dressing
3.3
condemned meat
inspected and judged by a competent person, or otherwise determined by the competent
authority, as being unsafe or unsuitable for human consumption and requiring appropriate
disposal
3.4
dehairing
process of removing the hair from the skin of a swine after scalding
3.5
evisceration
process of removing the internal organs in the abdominal and thoracic cavities
3.6
finished floor line
uppermost surface of a floor once construction has been completed
3.7
meat
edible part of the carcass including edible offal
3.8
red offal
includes heart, liver, kidney, spleen, tongue, lungs, and pancreas
3.9
retained carcass
carcass requiring further examination as declared by a veterinary
3.10
scalding
subjecting swine to hot water (58-60 oC) to prepare skin for dehairing
3.11
slaughter area
area in the slaughterhouse that covers restraining to carcass hanging area
3.12
slaughterhouse
abattoir
premises that are approved and registered by the controlling authority in which food
animals are slaughtered for human consumption
2
PNS/BAFS PABES 305:2020
3.13
stunning
procedure for rendering the swine unconscious and insensible to pain
3.14
swine
general term for hogs, pigs, native pigs, and shoats
3.15
white offal
includes stomach, small intestine, and large intestine
4 Classification
These slaughterhouses are allowed to operate by the respective Local Government Unit
(LGU) wherein the meat inspection is supervised by the Municipal or City Meat Inspection
Office. The distribution and sale of meat and meat products are limited to the
City/Municipality where the meat establishment is located.
These are slaughterhouses with minimum facilities and operational procedures that are
adequate to slaughter food animals for distribution and sale only within the city or
municipality where the slaughterhouse is located.
These are slaughterhouses with fully automated/ mechanized facilities and operational
procedures that are adequate to slaughter food animals or cut and pack carcasses or
primal parts for distribution and sale for domestic and international trade. The competent
3
PNS/BAFS PABES 305:2020
authority shall certify that the meat is fit for human consumption. The application of Hazard
Analysis and Critical Control Point (HACCP) program shall be required for this
classification.
This system utilizes fully automated equipment for elevating and lowering of swine and
carcass. The overhead railing system for this classification is continuous at a constant
speed.
This is a type of slaughterhouse where all slaughtering procedure is done in a single floor.
It is usually applicable for semi and fully mechanized system.
Two-tiered floor slaughterhouse has two floor levels and is applicable for manual
operation. Stunning to scalding process is done in the higher elevation while vertical
dehairing, evisceration, down to the last slaughtering procedure, is done in the lower tier.
Three-tiered floor slaughterhouse has three floor levels and is applicable for manual
operations. Stunning to scalding operation is done in the highest floor, horizontal
dehairing is done in the second floor, and the remaining slaughtering procedures are done
in the lowest floor.
4
PNS/BAFS PABES 305:2020
5 Site Requirements
5.1.1 The Comprehensive Land Use Plan (CLUP) of the Local Government Unit (LGU)
shall be considered in site determination.
5.1.2 The slope, terrain, foundation, and soil conditions on the site shall be suitable for
the construction of substantial and permanent buildings. The previous flood line of the
site shall be checked and used as basis of the design.
5.1.3 The prevailing winds in the area shall be considered to avoid problems caused by
substances from more distant sources carried by wind.
5.1.4 The seismic conditions of the area shall be given consideration such that the
slaughterhouse will not lie on fault lines.
5.1.6 The site shall have continuous supply of potable water to meet the required amount
of water for slaughtering and other related use.
5.1.7 The land acquired for the proposed slaughterhouse should be sufficient to permit
future expansion as overcrowding of facilities may give sanitation problems.
5.2.1 The slaughterhouse shall be located at least 200 m away from any building used
for human habitation, national highway, public or commercial buildings/places, and any
animal production facilities. The location should be free from dust, odor, smoke, and other
contaminants. Likely future commercial and residential developments should be taken
into account.
5.2.2 The slaughterhouse shall be located at least 10 m away from the river bank.
5.3 Accessibility
There shall be a provision for accessible road networks for the transport of swine and
meat/carcass to and from the slaughterhouse. These roads should be paved/compacted
with gravel or similar hard material.
5
PNS/BAFS PABES 305:2020
6 Size
6.1 The minimum size of slaughtering area for new/ extensively altered/ renovated
slaughterhouse shall be 21 m2. Multiple lines are warranted when the number of swine to
be slaughtered is increased.
6.2 The minimum size of the offal cleaning area shall be 10 m2.
7.1.1 Structural design shall conform with the existing National Building Code.
7.1.2 The site shall be elevated above the flood line or to at least 800 mm above the
road level. The fill material shall be compacted thoroughly by rolling or pounding.
7.1.3 The floors shall be made of waterproof, anti-slippery, load-bearing, and easy-to-
clean materials.
7.1.4 The floors shall be sloping towards the drains. The floor slope shall be at least 3°
towards open canal with stainless grating.
7.1.5 All angles between the floors and walls shall be concaved to a height of at least
7.62 cm from the floor.
7.2.1 The walls and partitions inside the slaughtering facility shall be constructed of
impervious materials with a height of at least 2 m from the floor.
7.2.2 As much as possible, the interior walls shall be flat with no protruding columns
inside the facility.
7.2.3 Internal wall and partition surfaces shall be durable and easy to clean. It shall be
smooth-finished and painted with white.
7.2.4 Wall partition shall be at least 2 m high with tops and ledges sloped at 45o.
7.2.5 Walls shall be concaved at wall-to-wall junctions with a minimum radius of 75 mm.
7.3 Windows
7.3.1 Windows at the stunning and bleeding area shall be double-screened and shall be
at least 0.6 m high and 0.40 m from the bottom of the roof beam.
7.3.2 Offal cleaning rooms shall be provided with windows for ventilation purposes
measuring 0.60 m high and located at 1.20 m from the finish floor line.
6
PNS/BAFS PABES 305:2020
7.3.3 Offal channel windows shall measure 0.6 m wide and 0.6 m high. It shall be located
at 0.7 m from finished floor line.
7.3.4 All channel windows shall be provided with plastic curtains of 50-50 overlap or with
stainless steel flap or plate. If stainless steel flap or plate is used, the perimeter edge shall
not be sharp.
7.3.5 Fixed and clear tempered glass window in all offices such as Meat Inspector’s
office and/or Administrative Office shall be provided to allow viewing of the slaughtering
processes.
7.3.6 Windows and other openings shall be provided with no.16 wire mesh screen and/
or other appropriate materials.
7.4.1 Dispatch doorway shall be at least 1.5 m wide. It should be equipped with roll-up
door or other appropriate types of doors.
7.4.4 The juncture between the wall and the jambs shall be sealed with a flexible sealing
compound.
7.4.5 Doors leading inside the slaughtering facility shall have a plastic curtain with 50-
50 overlap.
7.4.6 Yellow plastic curtains shall be used for doors and windows facing exterior while
white plastic curtains shall be used indoor.
7.4.7 Doors opening from areas of the slaughtering facility where meat is handled shall
either be fitted with air screens or self-closing and snug fitting double action doors.
7.4.8 There shall be a separate exit door for meat, offal and manure.
7.4.9 There shall be separate entrance and exit doors for the processing crew and
visitors.
7.4.10 The individual doors of the toilet shall be self-closing and tightly fitted.
7.4.11 There shall be a separate entrance and exit doors for personnel on the processing
area/slaughter area and offal room.
7
PNS/BAFS PABES 305:2020
7.5 Ceiling
7.5.2 Ceilings for offices, eaves, toilets, and entry of personnel should be at least 2.7 m
from the floor.
7.5.4 If an open joist ceiling is used, the joist shall be treated to prevent rusting and
corrosion and shall have a minimum center spacing of 900 mm.
7.5.5 Roof eaves shall be provided with ceiling for insect proofing.
7.6 Roof
7.6.1 The roof structure should be made of painted steel trusses. Roof shall have
a monitor equipped with steel louver and shall be double-screened.
7.6.2 Roofing materials should be made of galvanized steel and other forms of steel
sheeting with corrosion resistant coatings.
7.6.3 Clip edges of roofing onto concrete walls for climate resiliency.
7.6.4 Roof vents and other open spots shall be properly screened.
7.6.5 Over-hangs, gutters, and down spouts shall be provided to divert rainwater away
from the slaughterhouse waste water.
7.7.1 There shall be good ventilation system built/installed in the facility to facilitate entry
of fresh air in all working areas and to allow removal of obnoxious odor, heat, and
moisture.
7.7.2 Openings for ventilation shall be provided with no.16 wire mesh screen and/ or
other appropriate materials.
7.7.3 Ventilation systems shall be designed and constructed to ensure that air flows from
food areas to by-product areas and edible to inedible areas.
7.7.4 Airflow from warm areas to cold areas shall be minimized to avoid condensation
problems.
7.7.5 Airflow pattern should not exit through the restrainer area to the chute as this would
cause balking of the swine.
8
PNS/BAFS PABES 305:2020
7.8.1 There shall be adequate light, both natural and/or artificial, for all rooms and
compartments.
7.8.2 There shall be protective coverings for the lighting fixtures to ensure that broken
glass/ lighting shall not scatter in case of breakage.
NOTE If plastic led lamps were installed, covered fixtures are not necessary.
7.8.3 Light shall not cause alteration on the color of the meat.
8 Slaughterhouse Facility
8.1.1 The stunning area should be provided to confine swine for stunning before
bleeding.
8.1.2 If a restrainer is used, it shall comply with the requirements of PAES 502: 2007
Slaughterhouse Equipment – Hog Restrainer –Specifications.
8.1.3 The entrance chute and gate of the restrainer shall be free from any broken parts
with sharp edges or any protruding parts that may injure or disturb the swine which may
cause backing.
8.1.4 Overhead gates should be counterweighted to prevent back bruises. The bottom
of the gate should be padded with cut tires or conveyor belting.
8.1.5 The flooring material from the chute to the restrainer box shall be of similar color
or material to prevent balking. Non-slip flooring for box-type restrainer and a non-slip,
cleated entrance ramp for conveyor restrainer shall be provided. Non-slip flooring may
be made of stamped pattern of raised and expanded metal into the wet concrete, rubber
mats, or flat steel mats.
9
PNS/BAFS PABES 305:2020
8.1.6 The restrainer shall be properly lighted. There shall be an installed light above the
entrance over the chute. Lighting coming under a conveyor restrainer should be blocked
to prevent balking of swine due to visual cliff effect.
8.1.7 Convenient holder shall be installed for the driving tools and stunning instruments
and shackles shall be provided for hoisting of swine.
8.2.2 A bleeding area shall be provided in front of the stunning box which can be made
of a raised sturdy frame of expanded metal.
8.2.3 The bleeding area should be enclosed by a fence. It should be high and sturdy
enough to prevent escape of improperly stunned swine.
8.2.4 The bleeding trough shall be as specified below:
8.2.4.1The bleeding trough shall have a smooth, impervious surface such as stainless
steel to allow the flow of the blood. It shall be easy to clean and sanitize.
8.2.4.2 Troughs with sufficient width shall be constructed to hold the dripping from
hanging carcasses. It shall be curbed and steeply sloped and directly leads to blood tank/
container.
There shall be a designated area for the scalding and dehairing of swine.
8.4.1 Stationary or elevating type platforms shall be located away from the overhead rail.
It shall be made of rust-resistant material and provided with a protective.
8.4.2 Inspection table with hanger shall be provided for red offal.
8.4.4 Hand-dips utilizing an approved sanitizing agent with rinsing facilities shall be
provided and situated in strategic location.
8.4.5 Offal tray/ receptacle shall be provided for catching of white offal during
evisceration.
10
PNS/BAFS PABES 305:2020
8.5.1 A separate room or fixed area protected from contamination shall be provided for
the emptying and cleaning of stomach and intestines and for the preparation of casings
or edible fat.
8.5.2 The offal room shall be physically separated from the other areas.
8.5.3 The offal room shall have separate channel windows for receiving and dispatching
products.
8.6.1 Retained carcass area/rails shall be located adjacent to the main slaughter hall
inspection points.
8.6.2 From this retained carcass area/rails, an overhead rail that reconnects to the main
slaughter line toward chill rooms or condemned meat receptacle shall be provided.
8.6.5 There shall be provision of platforms for further inspection of retained carcass.
8.7.1 Cold storage facilities shall be provided with thermohygrometers and shall have
adequate capacity to maintain a temperature of 5°C or less at all times. Specifically, the
following are the recommended temperatures:
8.7.2 The cold storage room shall be designed in such a way that there is adequate
circulation of air around the chilled product.
8.7.3 Chill doors shall be sliding, single, or double-hinged. Internal finishing shall be
durable, impervious, and with good insulation and floor drainage.
8.7.4 Areas of walls where carcasses come in contact during loading shall be protected
with stainless steel or galvanized/aluminum sheeting.
11
PNS/BAFS PABES 305:2020
8.7.6 Doors for chiller shall have safety feature that will prevent workers/operators from
being locked inside.
8.8.1 All items shall be stored above the floor. Storage may be a solid or slatted shelves,
pallets, or cabinets.
8.8.2 Shelves shall be constructed approximately 3 cm from the wall and the bottom
shall be approximately 38 cm above the floor.
8.9.1 The dispatch area shall have adequate space and shall allow orderly and efficient
loading of meat into transport vehicles.
9.1.1 The periphery of the slaughterhouse building and all other slaughtering facilities
shall be enclosed with fences. These perimeter fence shall have contact with the ground
at the lower edge.
9.1.2 There shall be separate gates for entrance/exit of live swine and entrance/exit for
carcasses/ meat. Main entrance/exit gates shall be equipped with wheel spray or wheel
bath for disinfection of the whole tire.
9.2 Parking and cleaning area for transport vehicles and surrounding lot
9.2.1 There shall be a designated area for parking of transport vehicles within the
slaughterhouse premises.
9.2.2 An appropriate area away from the production facility shall be designated for the
cleaning and disinfection of the transport vehicles. There shall be a drainage system that
leads towards the waste water treatment facilities.
9.2.3 The cleaning area shall be provided with faucets and pressurized hose.
12
PNS/BAFS PABES 305:2020
Boiler rooms shall be provided for supplying hot water with temperature of 82oC. It should
be equipped with heating facilities and shall conform with applicable provisions from Rule
1163.01 of Occupational Safety and Health Standards (OSHS).
The condemnation pit shall be appropriately designed and shall be located 60 m away
from the production facility. Other approved means of disposal may also be considered.
10 Sanitation Requirements
10.1.1 All water lines inside the slaughterhouse shall be made of non-corrosion material.
10.1.2 All water lines in the slaughter area shall be installed overhead. It shall be
equipped with hose and nozzle and is extended 1 m above the finished floor line.
10.1.3 There shall be an elevated stainless steel/food grade material water tank with a
capacity depending on the requirement of the slaughterhouse facility. The minimum water
supply should be 0.12 cu. M. (30 gal) per swine.
10.1.4 The slaughter floor shall have strategically placed nozzles in the bleeding area,
dehairing area, evisceration area, and final washing area.
10.2 Drainage
10.2.1.1 The spoon-type open drainage located inside the slaughter area should have
provisions for ease of cleaning.
10.2.1.2 Drainage canal outside the slaughterhouse building to the waste water facility
shall be covered with detachable concrete cover.
10.2.1.3 Drainage canal inside the slaughterhouse working area shall have 2% slope
towards the waste water treatment facility and should be concaved.
13
PNS/BAFS PABES 305:2020
10.2.1.4 There shall be means of collecting all solid and fat wastes from the end of the
slaughter floor drain.
10.2.1.5 Floor drainage shall flow from the clean area to the dirty area.
10.2.2.1 Close drainage shall be utilized in comfort rooms. Comfort rooms’ sewer line
shall be separated from the slaughtering drainage line.
10.2.2.2 The drainage piping system installations for toilets inside the buildings and
premises shall conform to the applicable provisions of the National Plumbing Code of the
Philippines.
10.2.2.3 One drain inlet shall be provided for each floor space with an area of 372 m2.
Slope shall be 0.64 centimeter per meter to the drainage inlet.
10.2.2.4 Drain inlets shall be at least 21 cm in diameter. It shall be provided with drain
covers with apertures having a minimum size of 400 mm2.
10.2.2.5 Floor drains shall be provided with a deep seal trap (P, U, S-shape) and rodent
screens.
10.2.2.6 Screw plugs shall be provided where water seal may evaporate in the traps.
10.3.2 The minimum number of toilets and shower for personnel shall be conform to Table
2.
14
PNS/BAFS PABES 305:2020
10.3.3 Toilet or shower floors shall be constructed of non-slip, hard impervious materials
with properly drained floor.
10.4.1 Hand-washing facilities shall be conveniently located in all rooms used for
slaughtering, evisceration, boning, preparation, packing, and other meat handling
practices. Notices shall be posted in prominent places instructing employees to wash their
hands immediately after using toilet facilities.
10.4.2 All faucets for hand washing of workers and guests shall be foot or knee-controlled
or sensor-operated.
10.5.1 Foot bath shall be provided before entering the working area. Foot bath shall be
1 m x 1 m with 6 in depth with plug and drain.
10.5.2 Boots washing facility area shall be provided with faucets at the worker’s entrance.
11 Waste Disposal
11.2 The wastewater treatment facilities and the disposal of the wastewater and solid
waste of the slaughterhouse shall comply with the effluent standards and environmental
standards set by the competent authorities.
11.3 The capacity of the dewatering tank shall be based on the maximum number of
swine to be slaughtered daily at 0.014 m3 per head.
11.4 All solid waste shall be collected daily, treated, and disposed to identified dumpsite.
12 Pest Control
12.1 There shall be provision that will prevent entry of pests in all areas of the
slaughterhouse.
12.2 Expanded metal or wire with a mesh not exceeding 127 mm shall be embedded in
the walls and floor at their junctions.
12.3 All windows and other exterior openings that could permit entry of insects, birds,
bats, etc., shall be equipped with screens. Fly chaser fans or other acceptable equivalent
devices shall be provided outside doorways where screening is not practicable.
15
PNS/BAFS PABES 305:2020
13 Amenities
13.1.1 The changing/locker room should be located where it will not be a potential source
of cross contamination of products. These rooms shall be separated from the toilet area.
13.1.3 Changing/locker room shall be separated but directly accessible from wash rooms.
All lockers shall be made of metal or wood.
13.1.4 Individual lockers shall be provided for employees. It shall have a floor clearance
of not less than 350 mm.
13.1.5 Elevated, concrete lockers with a height of 150 mm properly anchored and sealed
at the base-locker junction can also be used.
13.1.6 Clothes racks with overhead hat racks and suspended boot racks shall be made
of rust resisting metal with 350 – 400 mm floor clearance.
13.1.8 Changing/ locker room may have a separate entrance and exit doors.
13.2.1 The canteen or mess hall shall be separated from the slaughterhouse building.
13.3.1 A meat inspector office shall be provided. It shall be properly located and has
enough office facilities.
13.3.2 The minimum office space requirement shall be 5 m2 for one inspector and 1.4 m2
for each additional inspector.
13.3.3 There shall be a provision for locker cabinet and adjoining toilet.
13.3.4 There shall be a provision for fixed glass window for viewing.
13.4.1 The minimum office space requirement shall be 5 m2 for one office personnel and
1.4 m2 for each additional personnel.
16
PNS/BAFS PABES 305:2020
13.4.2 There shall be provision for locker cabinet and adjoining toilet.
Waiting area for visitors and personnel may be provided. It should be properly located
where it will not be a potential source of contamination.
14 Noise Control
14.1 Noise barriers such as screens around noisy equipment and operations shall be
provided.
14.2 All ventilation and extractor fans shall be fitted with silencers and all ducts shall be
lined with sound-absorbent materials.
14.3 Diesel forklift engines, other noisy vehicles, and air-powered tools shall be fitted
with exhaust mufflers.
14.4 If slaughterhouse is located near the dwelling or noise sensitive place, perimeter
noise barrier walls of 2 m to 4 m high and off-site noise barrier wall of 3 m high should be
provided.
14.5 The noise level should conform with the provisions given in Annex J.
17
PNS/BAFS PABES 305:2020
Annex A
(Informative)
Edible offal
edible viscera (internal organ, glands, and tissues), extremities, and other by-products
suitable for human consumption
Flaying
skinning
process of removing the skin for swine
Gambrelling
suspending the slaughter animal after dehairing
Restraining box/chute
compartment which is suitable for confining swine to facilitate stunning and which is so
constructed as to confine, without discomfort, to prevent any substantial movement of the
swine forward, backward or sideway
Shackling
attaching the shackles to the stunned swine for lifting to the overhead rails
Splitting
dividing carcass into two equal parts along the backbone
18
PNS/BAFS PABES 305:2020
Annex B
(Informative)
Table B.1 Recommended Vertical and Horizontal Distances in the Slaughter Area
19
PNS/BAFS PABES 305:2020
Annex C
(informative)
20
PNS/BAFS PABES 305:2020
21
PNS/BAFS PABES 305:2020
22
PNS/BAFS PABES 305:2020
Annex D
(informative)
Equipment Layout
23
PNS/BAFS PABES 305:2020
Annex E
(informative)
24
PNS/BAFS PABES 305:2020
Annex F
(normative)
The threshold limit values refer to sound pressure that represents conditions under which
it is believed that nearly all workers may be repeatedly exposed without adverse effect on
their ability to hear and understand normal speech.
F.2.1 The values specified in Table D.1 apply to total time of exposure per working day
regardless of whether this is one continuous exposure or a number of short-term
exposures but does not apply to impact or impulsive type of noise.
F.2.2 If the variation in noise level involves maximum intervals of one (1) second or less,
it shall be considered as continuous. If the interval is over one (1) second, it becomes
impulse or impact noise.
F.2.3 When the daily noise exposure is composed of two or more periods noise exposure
of different levels, their combined effect should be considered rather than the effect of
each.
If the sum of Equation A exceeds one (1), then the mixed exposure should be considered
to exceed the threshold limit value. However, the permissible levels found in the table
25
PNS/BAFS PABES 305:2020
shall not be exceeded for the corresponding number of hours per day allowed. Noise
exposures of less than 90 dBA are not covered by the equation below.
𝐶1 𝐶2 𝐶3
𝑋= + +
𝑇1 𝑇2 𝑇3
F.2.4 Exposures to impulsive or impact noise shall not exceed 140 decibels peak sound
pressures level (ceiling value).
26
PNS/BAFS PABES 305:2020
Annex G
(informative)
Slaughtering of Swine
27
PNS/BAFS PABES 305:2020
Bibliography
Abattoirs Designs and Design Concepts for ASEAN. ASEAN Food Handling Bureau.
Malaysia, 1981.
Design and Constructrion of Slaughterhouse (20-50 Heads Hogs and 5-10 Heads Large
Animals Capacity) Guidebook. Department of Agriculture- National Meat Inspection
Service
28
Department of Agriculture
Bureau of Agriculture and Fisheries Standards
Technical Working Group (TWG) for the Revision of Philippine Agricultural
Engineering Standard (PAES) for Slaughterhouse- Swine
Members
7 Jovita Gonzales
DA- Philippine Council for Agriculture
and Fisheries