Powerful performance. Flexible control.

PowerFlex 753 AC Drive Branch circuit


protection supplied
separately
0.37…270 kW/0.5…400 Hp in voltages from 200…690V

Designed for general purpose applications, the PowerFlex 753 AC drive Isolation Transformers and Input
Line Reactors are available.
offers multiple options and features along with the added benefit of See pages 138…148.
simple integration. The PowerFlex 753 offers standard built-in I/O, making
it an ideal solution for OEMs and system integrators looking to reduce
Integral EMC Filter. External
engineering costs, deliver machines to market faster and meet end-user Common Mode Choke is available.
demand for more productive and safer machines. See page 130 and 1321 Power
Conditioning Products Technical
Data, publication 1321-TD001,
for additional information.
PowerFlex 753 Drive at a Glance
Ratings
200…240V 0.37…132 kW/0.5…200 Hp / 2.2…477 A
1
380…480V 0.75…270 kW / 1.0…400 Hp / 2.1…477 A
575…600V 1.0…300 Hp / 1…289 A
690V 7.5…250 kW / 12…263 A
Motor Control • V/Hz Control • Vector Control with FORCE Technology
• Sensorless Vector Control (with and without encoder)
• Interior Permanent Magnet
Enclosures • IP00/IP20, NEMA/UL Type Open • IP54, NEMA/UL Type 12
2
• Flange Mount

Safety • Safe Torque Off SIL3, PLe, CAT 3 • Safe Speed Monitor SIL3, PLe, CAT 4
Additional • DeviceLogix • Pump Jack and Pump Off for oil well 3
Features • Predictive Diagnostics applications
• Adjustable Voltage Control • Pump and Traverse for fibers applications 4
• Three option slots for I/O, feedback, safety, • Conformal Coating
auxiliary control power, communications • DC Link Choke
(1)
• Indexing • Automatic Device Configuration

Certifications • ATEX(2) • RCM


• cULus • RoHS Output Reactors, Terminators
and Reflected Wave Devices
• CE • TÜV FS(3 are optional.
• EAC • WEEE See pages 136…148.
• KCC For a complete list, search PowerFlex Certifications
on literature.rockwellautomation.com
Options See pages 126…148
(1) Requires Dual-port EtherNet/IP Option Module (Cat. No. 20-750-ENETR), firmware version 7, Studio 5000 Logix Designer, and Drive Add-On
Profiles version 4.04 or higher.
(2) Certification requires 11-series I/O and ATEX daughter card options.
(3) Certification applies to 20-750-S and 20-750-S1 Safety Options when installed in drive.

Safety, feedback, and other drive


1 LCD Human Interface Module (HIM) with multi-language support in scrolling text available as options are available.
optional accessory. See page 126 for other options. See pages 129…132.

2 Multiple communication options for industrial networks available. See page 126 for additional
options.

3 Embedded I/O: 3 digital inputs, 1 relay output, 1 transistor output, 1 analog input, 1 analog output,
and 1 PTC input. See page 126 for additional options.

4 Integral brake resistor on Frames 1…5, optional on Frames 6…7. Resistors are available.
See page 136.

66 Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019


PowerFlex 753 AC Drive

380…400V AC, Three-phase Drives


IP00/IP20, NEMA/UL Type Open(1)
Normal Duty Heavy Duty
Output Amps Output Amps
Cont. 1 min 3s kW Cont. 1 min 3s kW Cat. No.(2)(3) Frame Size
2.1 2.3 3.2 0.75 1.3 2.3 3.2 0.37 20F11RC2P1JA0NNNNN 1
3.5 3.9 5.3 1.5 2.1 3.9 5.3 0.75 20F11RC3P5JA0NNNNN
5 5.5 7.5 2.2 3.5 5.5 7.5 1.5 20F11RC5P0JA0NNNNN
8.7 9.6 13.1 4 5 9.6 13.1 2.2 20F11RC8P7JA0NNNNN
11.5 13.1 17.3 5.5 8.7 13.1 17.3 4 20F11RC011JA0NNNNN
15.4 16.9 23.1 7.5 11.5 17.2 23.1 5.5 20F11RC015JA0NNNNN
2.1 3.1 3.7 0.75 2.1 3.1 3.7 0.75 20F11NC2P1JA0NNNNN 2
3.5 5.2 6.3 1.5 3.5 5.2 6.3 1.5 20F11NC3P5JA0NNNNN
5 7.5 9 2.2 5 7.5 9 2.2 20F11NC5P0JA0NNNNN
8.7 13 15.6 4 8.7 13.0 15.6 4 20F11NC8P7JA0NNNNN
11.5 17.2 20.7 5.5 11.5 17.2 20.7 5.5 20F11NC011JA0NNNNN
15.4 16.9 23.1 7.5 11.5 17.2 20.7 5.5 20F11NC015JA0NNNNN
22 24.2 33 11 15.4 24.2 33 7.5 20F11NC022JA0NNNNN
30 33 45 15 22 33 45 11 20F11NC030JA0NNNNN 3
37 40.7 55.5 18.5 30 45 55.5 15 20F11NC037JA0NNNNN
43 47.3 64.5 22 37 55.5 66.6 18.5 20F11NC043JA0NNNNN
60 66 90 30 43 66 90 22 20F11NC060JA0NNNNN 4
72 79.2 108 37 60 90 108 30 20F11NC072JA0NNNNN
85 93.5 128 45 72 108 130 37 20F11NC085JA0NNNNN 5
104 114 156 55 85 128 156 45 20F11NC104JA0NNNNN
140 154 210 75 104 156 210 55 20F1ANC140JN0NNNNN(4) 6
(4)
170 187 255 90 140 210 255 75 20F1ANC170JN0NNNNN
205 226 308 110 170 255 308 90 20F1ANC205JN0NNNNN(4)
260 286 390 132 205 308 390 110 20F1ANC260JN0NNNNN(4)
302 332 453 160 260 390 468 132 20F1ANC302JN0NNNNN(4) 7
(4)
367 404 551 200 302 453 551 160 20F1ANC367JN0NNNNN
456 502 684 250 367 551 684 200 20F1ANC456JN0NNNNN(4)
477 525 716 270 367 551 684 200 20F1ANC477JNONNNNN(4)
(1) Frames 1…5 are IP20, NEMA/UL Type Open. Frames 6…7 are IP00, NEMA/UL Type Open. Frames 1…7 can be converted to IP20, NEMA/UL Type 1 with optional kit (20-750-NEMA1-Fx), where x is the frame size
of the drive.
(2) The 5th character determines Input Type; “1” = AC input with precharge and DC terminals, and “A” = AC input with precharge and no DC terminals. For DC input drives, see DRIVES-SG001, the PowerFlex Common Bus
Configuration Selection Guide.
(3) The 11th character determines default Filtering and Common Mode Cap jumper configuration; “J” = Installed, and “A” = Removed.
(4) The 12th character determines whether an internal dynamic braking IGBT is included; “A” = Internal dynamic braking transistor installed, and “N” = No internal dynamic braking transistor.

70 Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019


PowerFlex 753 AC Drive

380…400V AC, Three-phase Drives (continued)


IP54, NEMA/UL Type 12
Normal Duty Heavy Duty
Output Amps Output Amps
Cont. 1 min 3s kW Cont. 1 min 3s kW Cat. No.(1)(2) Frame Size
2.1 3.1 3.7 0.75 2.1 3.1 3.7 0.75 20F11GC2P1JA0NNNNN 2
3.5 5.2 6.3 1.5 3.5 5.2 6.3 1.5 20F11GC3P5JA0NNNNN
5 7.5 9 2.2 5 7.5 9 2.2 20F11GC5P0JA0NNNNN
8.7 13 15.6 4 8.7 13 15.6 4 20F11GC8P7JA0NNNNN
11.5 17.2 20.7 5.5 11.5 17.2 20.7 5.5 20F11GC011JA0NNNNN
15.4 16.9 23.1 7.5 11.5 17.2 20.7 5.5 20F11GC015JA0NNNNN
22 24.2 33 11 15.4 24.2 33 7.5 20F11GC022JA0NNNNN
30 33 45 15 22 33 45 11 20F11GC030JA0NNNNN 3
37 40.7 55.5 18.5 30 45 55.5 15 20F11GC037JA0NNNNN
43 47.3 64.5 22 37 55.5 66.6 18.5 20F11GC043JA0NNNNN
60 66 90 30 43 66 90 22 20F11GC060JA0NNNNN 4
72 79.2 108 37 60 90 108 30 20F11GC072JA0NNNNN 5
85 93.5 128 45 72 108 130 37 20F11GC085JA0NNNNN
104 114 156 55 85 128 156 45 20F1AGC104JN0NNNNN(3) 6
(3)
140 154 210 75 104 156 210 55 20F1AGC140JN0NNNNN
170 187 255 90 140 210 255 75 20F1AGC170JN0NNNNN(3)
205 226 308 110 170 255 308 90 20F1AGC205JN0NNNNN(3)
260 286 390 132 205 308 390 110 20F1AGC260JN0NNNNN(3) 7
(3)
302 332 453 160 260 390 468 132 20F1AGC302JN0NNNNN
367 404 551 200 302 453 551 160 20F1AGC367JN0NNNNN(3)
456 502 684 250 367 551 684 200 20F1AGC456JN0NNNNN(3)
(1) The 5th character determines Input Type; “1” = AC input with precharge and DC terminals, and “A” = AC input with precharge and no DC terminals. For DC input drives, see DRIVES-SG001, the PowerFlex Common Bus
Configuration Selection Guide.
(2) The 11th character determines default Filtering and Common Mode Cap jumper configuration; “J” = Installed, and “A” = Removed.
(3) The 12th character determines whether an internal dynamic braking IGBT is included; “A” = Internal dynamic braking transistor installed, and “N” = No internal dynamic braking transistor.

Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019 71


PowerFlex 753 AC Drive

380…400V AC, Three-phase Drives (continued)


Flange Mount (Front: IP20, NEMA/UL Type Open; Back/Heatsink: IP66, NEMA/UL Type 4X)
Note: Frame 6…7 IP00, NEMA Type Open drives can be converted to a flange mount drive (back/heatsink: IP66, NEMA/UL
Type 4X) with an optional user installed flange kit (kit 20-750-FLNG4-F6 for Frame 6, and kit 20-750-FLNG4-F7 for Frame 7).
See page 70 for 380…400V, Frame 6…7 IP00, NEMA Type Open drives.

Normal Duty Heavy Duty


Output Amps Output Amps
Cont. 1 min 3s kW Cont. 1 min 3s kW Cat. No.(1)(2) Frame Size
2.1 3.1 3.7 0.75 2.1 3.1 3.7 0.75 20F11FC2P1JA0NNNNN 2
3.5 5.2 6.3 1.5 3.5 5.2 6.3 1.5 20F11FC3P5JA0NNNNN
5 7.5 9 2.2 5 7.5 9 2.2 20F11FC5P0JA0NNNNN
8.7 13 15.6 4 8.7 13 15.6 4 20F11FC8P7JA0NNNNN
11.5 17.2 20.7 5.5 11.5 17.2 20.7 5.5 20F11FC011JA0NNNNN
15.4 16.9 23.1 7.5 11.5 17.2 20.7 5.5 20F11FC015JA0NNNNN
22 24.2 33 11 15.4 24.2 33 7.5 20F11FC022JA0NNNNN
30 33 45 15 22 33 45 11 20F11FC030JA0NNNNN 3
37 40.7 55.5 18.5 30 45 55.5 15 20F11FC037JA0NNNNN
43 47.3 64.5 22 37 55.5 66.6 18.5 20F11FC043JA0NNNNN
60 66 90 30 43 66 90 22 20F11FC060JA0NNNNN 4
72 79.2 108 37 60 90 108 30 20F11FC072JA0NNNNN
85 93.5 128 45 72 108 130 37 20F11FC085JA0NNNNN 5
104 114 156 55 85 128 156 45 20F11FC104JA0NNNNN
(1) The 5th character determines Input Type; “1” = AC input with precharge and DC terminals, and “A” = AC input with precharge and no DC terminals. For DC input drives, see DRIVES-SG001, the PowerFlex Common Bus
Configuration Selection Guide.
(2) The 11th character determines default Filtering and Common Mode Cap jumper configuration; “J” = Installed, and “A” = Removed.

72 Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019


PowerFlex 753 AC Drive

Approximate Dimensions and Weights


Dimensions are in mm (in.) - weights are in kg (lb)

IP00/IP20, NEMA/UL Type Open


Frame H W D Weight(1)
1 400.5 (15.77) 110 (4.33) 211 (8.31) 6 (12.75)
2 424.2 (16.7) 134.5 (5.3) 212 (8.35) 7.8 (17.2)
3 454 (17.87) 190 (7.48) 11.8 (26.1)
4 474 (18.66) 222 (8.74) 13.6 (30)
5 550 (21.65) 270 (10.63) 20.4 (45)
6 665.5 (26.2) 308 (12.13) 346.4 (13.64) 38.6 (85)
7 881.5 (34.7) 430 (16.93) 349.6 (13.76) 72.6…108.9
(160…240)
(1) Weights are approximate. Refer to 750-TD001, the PowerFlex 750-Series Technical Data, for detailed
weight information.

IP54, NEMA/UL Type 12


Frame H W D Weight(1)
2 543.2 (21.39) 215.3 (8.48) 222.2 (8.75) 8 (17)
3 551 (21.69) 268 (10.55) 220.1 (8.67) 12 (26)
4 571 (22.48) 300 (11.81) 14 (30)
5 647 (25.47) 348.0 (13.7) 20 (45)
6 1298.3 (51.11) 609.4 (24) 464.7 (18.3) 91 (200)
7 1614 (63.54) 162 (357)
(1) Weights are approximate. Refer to 750-TD001, the PowerFlex 750-Series Technical Data, for detailed
weight information.

Flange Mount
Frame H W D1 D2 Weight(1)
2 481.8 (18.97) 206.2 (8.12) 148.3 (5.84) 63.7 (2.51) 8 (17)
3 515 (20.28) 260 (10.24) 127.4 (5.02) 84.6 (3.33) 12 (26)
4 535 (21.06) 292 (11.5) 14 (30)
5 611 (24.06) 340 (13.39) 20 (45)
6 665.5 (26.2) 308 (12.13) 208.4 (8.2) 138 (5.43) 38 (84)
7 875 (34.45) 430 (16.93) 96 (212)
(1) Weights are approximate. Refer to 750-TD001, the PowerFlex 750-Series Technical Data, for detailed weight information.

Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019 81


PowerFlex 7-class Options
Human Interface Modules

Used with PowerFlex Drive


Description Cat. No. 70 753/755 755TL/755TR
No HIM (Blank Plate), Handheld/Local (Drive Mount) 20-HIM-A0 ✓ ✓ ✓
LCD Display, Full Numeric Keypad, Handheld/Local (Drive Mount) 20-HIM-A3 ✓ — —
LCD Display, Programmer Only, Handheld/Local (Drive Mount) 20-HIM-A5 ✓
Enhanced, LCD, Full Numeric Keypad, Handheld/Local (Drive Mount) 20-HIM-A6 ✓ ✓ ✓
(1)(2)
Remote (Panel Mount) LCD Display, Full Numeric Keypad 20-HIM-C3S ✓ — —
Remote (Panel Mount) LCD Display, Programmer Only(1)(2) 20-HIM-C5S ✓
Enhanced, LCD, Full Numeric Keypad(1)(2) 20-HIM-C6S ✓ ✓ ✓

(1) IP66, NEMA Type 4X/12−only for indoor use.


(2) Includes a 1202-C30 interface cable (3 m/9.8 ft) for connection to drive.

Human Interface Module (HIM) Accessories


Used with PowerFlex Drive
Description Cat. No. 70 753/755 755TL/755TR
(1)
Bezel Kit for LCD HIMs, NEMA Type 1 20-HIM-B1 ✓ ✓ ✓
PowerFlex HIM Interface Cable, 1 m (3.3 ft)(2) 20-HIM-H10 ✓ ✓ ✓
Comm Option Cable Kit (Male-Male)
0.33 m (1.1 ft) 1202-C03 ✓ ✓ ✓
1 m (3.3 ft) 1202-C10 ✓ ✓ ✓
3 m (9.8 ft) 1202-C30 ✓ ✓ ✓
9 m (29.5 ft) 1202-C90 ✓ ✓ ✓
Cable Kit (Male-Female)(3)
0.33 m (1.1 ft) 1202-H03 ✓ ✓ ✓
1 m (3.3 ft) 1202-H10 ✓ ✓ ✓
3 m (9.8 ft) 1202-H30 ✓ ✓ ✓
9 m (29.5 ft) 1202-H90 ✓ ✓ ✓
DPI™ Cable Kit with Connectors, Tools and 100 m (328 ft) Cable 1202-CBL-KIT-100M ✓ ✓ ✓
DPI Cable Connector Kit 1202-TB-KIT-SET ✓ ✓ ✓
DPI/SCANport™ One to Two Port Splitter Cable 1203-S03 ✓ ✓ ✓

(1) Includes a 1202-C30 interface cable (3 m/9.8 ft) for connection to drive.
(2) Required only when HIM is used as handheld or remote.
(3) Required in addition to 20-HIM-H10 for distances up to a total maximum of 10 m (32.8 ft).

126 Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019


PowerFlex 7-class Options

Communication Option Kits


Used with PowerFlex Drive
Description Cat. No. 70 753/755 755TL/755TR
BACnet/IP Option Module 20-750-BNETIP — ✓ —
BACnet® MS/TP RS485 Communication Adapter 20-COMM-B ✓ —
Coaxial ControlNet™ Option Module 20-750-CNETC — ✓ ✓
(1)
ControlNet™ Communication Adapter (Coax) 20-COMM-C ✓ ✓ —
DeviceNet™ Option Module 20-750-DNET — ✓ ✓
DeviceNet™ Communication Adapter 20-COMM-D ✓ ✓(1) —
Dual-port EtherNet/IP Option Module 20-750-ENETR — ✓ ✓
(1)
EtherNet/IP™ Communication Adapter 20-COMM-E ✓ ✓ —
Dual-port EtherNet/IP™ Communication Adapter 20-COMM-ER ✓ —
HVAC Communication Adapter 20-COMM-H ✓ ✓(1)
CANopen® Communication Adapter 20-COMM-K ✓ ✓(1)
LonWorks® Communication Adapter 20-COMM-L ✓ ✓(1)
Modbus/TCP Communication Adapter 20-COMM-M ✓ ✓(1)
Profibus DPV1 Option Module 20-750-PBUS — ✓ ✓ (3)
Single-port Profinet I/O Option Module 20-750-PNET ✓ ✓ (3)
Dual-port Profinet I/O Option Module 20-750-PNET2P ✓ ✓ (3)
(1)
PROFIBUS™ DP Communication Adapter 20-COMM-P ✓ ✓ ✓ (3)
ControlNet™ Communication Adapter (Fiber) 20-COMM-Q ✓ ✓(1) —
(1)
RS485 DF1 Communication Adapter 20-COMM-S ✓ ✓
External Communications Kit Power Supply 20-XCOMM-AC-PS1 ✓ ✓
DPI External Communications Kit 20-XCOMM-DC-BASE ✓ ✓
(2)
External DPI I/O Option Board 20-XCOMM-IO-OPT1 ✓ ✓
Compact I/O Module (3 Channel) 1769-SM1 ✓ ✓

(1) Requires a Communication Carrier Card (20-750-20COMM or 20-750-20COMM-F1). Refer to the Communication Accessories table on page 128 for details.
(2) For use only with DPI External Communications Kits 20-XCOMM-DC-BASE.
(3) Contact Rockwell Automation sales office for availability.

Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019 127


PowerFlex 7-class Options

PowerFlex 750-Series Drives Legacy Communication Compatibility

Most legacy communication adapters (20-COMM) can be used with the PowerFlex 753/755. However, the restrictions stated
below do apply.
Frame 1 - It is recommended that the 20-750-20COMM-F1 Communication Carrier Card only be installed in Port 4. Port 5 is
not accessible when this module is installed.
Frames 2 and larger - It is recommended that the 20-750-20COMM Communication Carrier Card be installed in Port 6. By
using Port 4 or 5, the adjacent left port becomes inaccessible to other option modules and it can interfere with network
cable connections.

Adapter Accesses Ports 0…6


for I/O Connections Accesses Ports 7 and Supports Drive
(Implicit and Explicit Higher Add-on Supports Asian-
Cat. No. Type Messaging) (I/O, Explicit Messaging) Profiles Languages(2)
20-COMM-B BACnet MS/TP Not Compatible
(2)
20-COMM-C ControlNet (Coax) ✓ v3.001 ✓ v3.001(2) ✓(3) ✓ v3.001(2)
(4)
20-COMM-D DeviceNet ✓ Not Compatible
20-COMM-E EtherNet/IP ✓ v4.001 (4)
✓ v4.001 (2)
✓(3) ✓ v4.001 (2)
20-COMM-H RS-485 HVAC ✓ v2.009(2)(5)
20-COMM-K CANopen ✓ v1.001(2) Not Compatible
20-COMM-L LonWorks ✓ v1.007(2)
20-COMM-M Modbus/TCP ✓ v2.001(2) ✓ v2.001(2) ✓ v2.001(2)
Not Compatible
20-COMM-P ControlNet (Fiber) ✓ v1.006(2) ✓ v1.006(2) Not Compatible
(2)
20-COMM-Q PROFIBUS DP ✓ v3.001 ✓ v3.001(2) ✓(3) ✓ v3.001(2)
20-COMM-S RS-485 DF1 ✓(4) Not Compatible

(1) Chinese, Japanese, and Korean languages are supported at the time of publication.
(2) Requires this adapter firmware version or higher.
(3) Requires firmware version v1.05 or higher of the drive Add-on Profiles for Studio 5000 Logix Designer software.
(4) Controller must be capable of reading/writing 32-bit floating point (REAL) values.
(5) Supports all three modes of operation (RTU, P1, N2).

Communication Accessories
Used with PowerFlex Drive
Description Cat. No. 70 753/755 755TL/TR
Universal Serial Bus™ (USB) Converter includes 2m USB, 20-HIM-H10 and 22-HIM-H10 Cables 1203-USB ✓ ✓ ✓
ControlNet T-tap Straight 1786-TPS — ✓ —
Communication Carrier Card for PowerFlex 750-Series Frame 1 drives 20-750-20COMM-F1 ✓
Communication Carrier Card for PowerFlex 750-Series Frame 2 or higher drives 20-750-20COMM ✓

128 Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019


PowerFlex 7-class Options

I/O Option Kits


Used with PowerFlex Drive
Description Cat. No. 753/755 755TL/755TR
(1)
ATEX Option Module with 1 Thermosensor Input Connection (requires 11-Series I/O Module below) 20-750-ATEX ✓ ✓
24V DC 11-Series I/O Module with 1 Analog In, 1 Analog Out, 3 Digital In and 2 Relay Outputs 20-750-1132C-2R ✓(1) ✓
(1)
24V DC 11-Series I/O Module with 1 Analog In, 1 Analog Out, 3 Digital In, 1 Relay and 2 Transistor Outputs 20-750-1133C-1R2T ✓ ✓
(1)
115V AC 11-Series I/O Module with 1 Analog In, 1 Analog Out, 3 Digital In and 2 Relay Outputs 20-750-1132D-2R ✓ ✓
(1)
24V DC 22-Series I/O Module with 2 Analog In, 2 Analog Out, 6 Digital In and 2 Relay Outputs 20-750-2262C-2R ✓ ✓
115V AC 22-Series I/O Module with 2 Analog In, 2 Analog Out, 6 Digital In and 2 Relay Outputs 20-750-2262D-2R ✓(1) ✓
(1)
24V DC 22-Series I/O Module with 2 Analog In, 2 Analog Out, 6 Digital In, 3 Digital Out, 1 Relay and 2 Transistor Outputs 20-750-2263C-1R2T ✓ ✓

(1) For kits to be used with CIP Motion instructions, the card can only be used in slot 7 of the PowerFlex 755 drive. It also requires PowerFlex 755 firmware version 12 and higher, and Studio 5000 version 28 and higher.

Safety Options(1)
Used with PowerFlex Drive
Description Cat. No. 70 753 755 755TL/755TR
DriveGuard Safe Torque Off 20A-DG01 ✓ — — —
Hardwired Safe Torque Off 20-750-S — ✓ ✓ ✓
(2) (2)
Hardwired Safe Speed Monitor 20-750-S1 ✓ ✓ ✓
(3)(4)
Networked Safe Torque Off 20-750-S3 — ✓ ✓(3)
Networked Integrated Safety Functions 20-750-S4 — ✓(5)(6) ✓(5)

(1) All PowerFlex 7-series drives can accommodate only one safety option.
(2) Requires the Dual Incremental Encoder or Universal Feedback Option. Also requires the 20-750-EMCSSM1-F8 EMC Option Kit with Frame 8…10 drives.
(3) Requires Studio 5000 version 30 and higher.
(4) Requires PowerFlex 755 firmware version 13 and higher. This option is not allowed while controlling a PowerFlex drive in CIP Motion mode.
(5) Requires Studio 5000 version 31 and higher.
(6) Requires PowerFlex 755 firmware version 14.002 and higher.

Feedback Options
Used with PowerFlex Drive
Description Cat. No. 70 753/755 755TL/755TR
5V/12V Encoder(1) 20A-ENC-1 ✓ — —
(2)
Incremental Encoder 20-750-ENC-1 — ✓ ✓
(2)
Dual Incremental Encoder 20-750-DENC-1 ✓ ✓
Universal Feedback (includes Stegmann, Heidenhain, SSI, Biss, 5V Incremental) 20-750-UFB-1 ✓(3) ✓

(1) Works only with PowerFlex 70 Enhanced Control. Drive is not CE EMC certified when the encoder interface option is installed.
(2) Homing and registration functions are not supported when using this device with Studio 5000 Logix Designer embedded motion instructions. To use these functions, the Universal
Feedback Board (20-750-UFB-1) must be used.
(3) Only for PowerFlex 755 drives.

Other Options
Used with PowerFlex Drive
Description Cat. No. 70 753/755 755TL/755TR
115V AC Interface AK-M9-115VAC-1 ✓ — —
Frame E Flange Gasket AK-M9-GASKET1-E4 ✓
Service Connection Board(1) SK-M9-SCB1 ✓

(1) Provides temporary DPI/HIM connection for NEMA/UL Type 1 and Flange drives with cover removed.

Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019 129


PowerFlex 7-class Options

PowerFlex 750-Series Option Kits


Used with PowerFlex Drive
Frame
Description Size Cat. No. 753 755
(1)
Auxiliary Power Supply 24V Aux Power Supply 1…7 20-750-APS ✓ ✓

DC Bus Bar Option Kit DC Bus Bars for240…480V AC drives 6 20-750-DCBB1-F6 ✓ ✓


7 20-750-DCBB1-F7 ✓ ✓
DC Bus Bars for 600…690V AC drives 6 20-750-DCBB2-F6 ✓ ✓
7 20-750-DCBB2-F7 ✓ ✓
8 20-750-BUS1A-F8 ✓ ✓
EMC Option Kit EMC Plate with Core for 380…480V AC drives 1 20-750-EMC1-F1 ✓ ✓
2 20-750-EMC1-F2 ✓ ✓
3 20-750-EMC1-F3 ✓ ✓
EMC Plate with Core for 600V AC drives 20-750-EMC3-F3 ✓ ✓
EMC Plate with Cores for 380…480V AC drives 4 20-750-EMC1-F4 ✓ ✓
5 20-750-EMC1-F5 ✓ ✓
EMC Plate with Cores for 600V AC drives 4 20-750-EMC3-F4 ✓ ✓
5 20-750-EMC3-F5 ✓ ✓
EMC Core for 380…480V AC drives 1 20-750-EMC2-F1 ✓ ✓
2 20-750-EMC2-F2 ✓ ✓
3 20-750-EMC2-F3 ✓ ✓
EMC Core for 600V AC drives 20-750-EMC4-F3 ✓ ✓
EMC Cores for 380…480V AC drives 4…5 20-750-EMC2-F45 ✓ ✓
EMC Cores for 600V AC drives 4 20-750-EMC4-F4 ✓ ✓
5 20-750-EMC4-F5 ✓ ✓
EMC Plate with Cores for 600…690V AC drives 6 20-750-EMC3-F6 ✓ ✓
7 20-750-EMC3-F7 ✓ ✓
EMC Plate with Cores for 600…690V AC drives (IP54 Only) 6 20-750-EMC5-F6 ✓ ✓
7 20-750-EMC5-F7 ✓ ✓
EMC Core – Inverter-mounted output cores, for 380…690V AC input and 8…10 20-750-EMCCM1-F8 — ✓
DC input drives.
One each for Frame 8, two each for Frame 9, and three each for Frame 10.
EMC Cores – Required when using the Safe Speed Monitor option 20-750-EMCSSM1-F8 ✓
20-750-S1 with 380…690V drives.
Door Shielding Kit 10 20-750-EMCDK1-F10 ✓
(2)
Exhaust Hood Exhaust Hood – IP20, NEMA/UL Type 1 drives. 8…10 20-750-HOOD1-F8 ✓

(1) Frame 8 and up drives can be powered from an external 24V DC source, a 20-750-APS is not required.
(2) Exhaust hood is standard on Frames 8…10, IP54-rated cabinets.

(table continues on next page)

130 Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019


PowerFlex 7-class Options

PowerFlex 750-Series Option Kits (continued)


Used with PowerFlex Drive
Frame
Description Size Cat. No. 753 755
Flange Adapter Kit Converts Open Type drive to external heatsink (flange) with 2 20-750-FLNG1-F2 ✓ ✓
NEMA/UL Type 1 integrity backside.
3 20-750-FLNG1-F3 ✓ ✓
This kit is for use with IP20, NEMA/UL Type 0 drives and does
not provide an air-tight or water-tight seal. Where sealing is 4 20-750-FLNG1-F4 ✓ ✓
required (for example, contaminated, dirty or wet environments), a drive
5 20-750-FLNG1-F5 ✓ ✓
with an “F” enclosure option must be used.
Converts Open Type drive to external heatsink (flange) with 6 20-750-FLNG4-F6 ✓ ✓
NEMA/UL Type 4X/12 integrity backside.
7 20-750-FLNG4-F7 ✓ ✓
L Bus Bar Kit Includes three L bus bars(3) 8…10 20-750-LBRKT1 — ✓
NEMA/UL Type 1 Option Kit NEMA/UL Type 1 Kit 1 20-750-NEMA1-F1 ✓ ✓
2 20-750-NEMA1-F2 ✓ ✓
3 20-750-NEMA1-F3 ✓ ✓
4 20-750-NEMA1-F4 ✓ ✓
5 20-750-NEMA1-F5 ✓ ✓
6 20-750-NEMA1-F6 ✓ ✓
7 20-750-NEMA1-F7 ✓ ✓
Power Terminal Extension Allows connection of two parallel leads to the AC terminals. 6 20-750-ACTE1-F6 ✓ ✓
Power Terminal Guard Provides additional protection against contact with the power terminals. 20-750-PTG1-F6 ✓ ✓
7 20-750-PTG1-F7 ✓ ✓
Remote Control POD Hardware, fiber-optic, and power supply cables to remotely mount the 8…10 20-750-RPD1-F8 — ✓
Mounting Kit control POD up to 23 m (75 ft) from the drive.
Roll-out Cart A wheeled roll-out cart that facilitates drive installation and removal. 20-750-CART1-F8 ✓
Recommended for PowerFlex 755 Frame 8…10 drives.

(1) Frame 8 and up drives can be powered from an external 24V DC source, a 20-750-APS is not required.
(2) Exhaust hood is standard on Frames 8…10, IP54-rated cabinets.
(3) Frame 8 drive is factory shipped with two L bus bars per phase as standard, Frame 9 drive is factory shipped with four L bus bars per phase as standard, and Frame 10 drive is factory shipped with six L bus bars per
phase as standard.

Rockwell Automation Publication PFLEX-SG002M-EN-P - July 2019 131