Explosion-Proof/Flameproof Field-Mount

BH
Enclosure for Hockey-Puck Instruments
March 2021

For Explosion-Proof/Flameproof
and General Locations
The BH housing provides superior explosion-proof/
flameproof protection for field-mounted units and meets
standards for enclosing indoor and outdoor electronic
instruments approved for use in explosion-proof, flameproof,
Clear Glass dust-ignition proof and intrinsically-safe locations.
Cover Safeguards Expensive Instruments
Meeting NEMA 4X and IP66 ratings, the BH housing is
resistant to ultraviolet rays and chemicals. Its high-impact
structure protects instruments even in harsh field conditions.
Durable, Secure Glass or Metal Cover
Instrument indicators, such as process displays and alarm
LEDs, can be easily viewed without removing the clear glass
cover (G cover). Both the glass and metal covers include a
locking screw for security.
Variety of Hub Configurations
Moore Industries provides a variety of conduit entry ports for
the BH housing. Choose from 2- or 3-hub configurations that
include combinations of M20 ports, ½-inch and ¾-inch NPT
ports.
Surface or Pipe-Mount Installation
Lightweight and easy to install, the BH housing installs
conveniently on any surface using the standard mounting
bracket, or on a 2-inch pipe using our pipe mount hardware
Solid Metal
(P option).
Cover
Retrofit Hardware Available
Upgrade your existing transmitters, displays, isolators, or
converters to the newest Moore Industries' technology, or
use the BH housing with your in-place units. Installation kits
for mounting the BH on existing Rosemount ® brackets are
available.
Handles a Wide Array of Instrumentation
The versatile construction of the BH housing makes it ideal
for use with any manufacturer’s hockey-puck units. It
protects any Moore Industries’ hockey-puck instrument,
including the following products:

Temperature Transmitters RIY, STZ, TDZ3, TDY,


TIY
ACX, ALX, ITX, SCX,
Isolators / Converters/ Transmitters SDY, MVX, TFZ, TPZ

Displays DSX, DVX, FDY, PSD

Demand Moore Reliability


©2021 Moore Industries-International, Inc.
700-710-99G
BH
Explosion-Proof/Flameproof Field-Mount
Enclosure for Hockey-Puck Instruments

Specifications
Body and Low Copper aluminum with a chromatic Hardware 2" pipe mount Mounting Low Copper aluminum with black
Cover conversion seal undercoat and a TGIC Bracket sulfuric acid anodized finish
Tag Anodized aluminum
Polyester powdercoat
Weight 1.23 kg (2 lbs., 12 oz)

Ordering Information
Enclosure # of Hubs Conduit Entry Port Cover Options

BH 2 Two hubs M M20 x 1.5 metric conduit G Glass A TestSafe-ANZEx (Australia) Flameproof with sensor assemblies†
explosion- 3 Three hubs side entry ports S Solid E ISSeP-ATEX (Europe) Flameproof with sensor assemblies†
proof/ N ½-inch NPT conduit side P Steel hardware for mounting the BH housing on a standard
flameproof entry ports 2-inch pipe
field-mount T ¾-inch NPT conduit side
enclosure for entry ports NOTE: For additional retrofit hardware for installing the BH onto existing Rosemount®
brackets, order part number 205-231-10.
hockey-puck †
NOTE: For all enclosures, the Units with A or E option come equipped as standard with 2-inch pipe mount hardware.
instruments
third hub will only be ½-inch NPT

When ordering the BH housing without instrumentation or as part of a line item order, specify:
Enclosure / Number of Hubs / Conduit Entry Port / Cover [Options]
Model number example:
BH / 2 / N / G [P]
When ordering the BH housing as part of a transmitter order (such as a TDZ3), place this condensed model number (with brackets or
strokes removed) within brackets at the end of the transmitter model number or refer to the transmitter data sheet:
Model number example:
TDZ3 / TPRG / 4-20MA / 12-42DC [BH2NGP]

Certifications (BH housing only)


CSA International
Explosion-Proof*
Class I, Division 1, Groups A*, B, C, D
C US
Class II, Division 1, Groups E, F, G
Class III, Division 1
Type 4X, IP66

ANZEx Test Safe - ANZEx (Australia) Flameproof


Ex d IIC T6 (Tamb 60°C)
ANZEx 07.3027

Factory Mutual Approvals


Explosion-Proof*
Class I, Division 1, Groups A*, B, C, D
Dust-Ignition Proof
Class II & III, Division 1, Groups E, F, G
NEMA 4X; IP66; T6 @ 60°CMax. Amb.

ATEX Directive 2014/34/EU (ISSeP): Flameproof


II 2 G Ex d IIC
II 2 D Ex tD A21 IP66

CE Conformant:
RoHS Directive 2011/65/EU - EN 50581
*Group A only: Seal all conduits within 18".
BH
Explosion-Proof/Flameproof Field-Mount
Enclosure for Hockey-Puck Instruments
Figure 1. BH enclosure dimensions with pipe mounting for BH2.
65 mm Top View Mounting Hardware
(n 2.55 in)
(4.00 in)

(3.31 in)

(2.69 in)

(4.90 in)

(5.08 in)
102 mm

124 mm

129 mm

(3.38 in)

(2.69 in)
84 mm

68 mm

86 mm

68 mm
ADDR

91 mm
9.7 mm
(3.58 in)
(0.38 in)
25 mm
128 mm
(1.00 in)
(5.03 in) Front View Side View

(2.25 in)
57 mm
(1.00 in)
25 mm
Figure 2. BH enclosure dimensions with three hubs and pipe mounting for BH3.
Top View Back View Mounting Hardware
(Showing Mounting Bracket)
65 mm
(n 2.55 in)
(4.90 in)

(5.10 in)
125 mm

130 mm

(5.25 in)
133 mm
(3.5 in)
89 mm

ADDR
R
(2.25 in)
(2.75 in)
57 mm
70 mm

(0.51 in)
13 mm

116 mm 57 mm Optional Third 1/2


(4.56 in) (2.25 in) NPT Port
70 mm
8 m
(0 7 m

(2.75 in)
in

Isometric View Side View


9.
.3

(2.25 in)
57 mm
(1.00 in)
(0.26 in)
6.6 mm

25 mm

Specifications and information subject to change without notice. Printed in U.S.A.