Enclosed Switches

ZE/ZV/ZV2/XE/XV/XV2 CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_4_4

General-purpose Enclosed
Switches with High Breaking
Capacity and High Durability
• Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
• X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
• Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
• Terminals face the front when the cover is removed for
easy connection.
• Switches with ground terminals have CE marking.
• Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
approved models.)
Be sure to read Safety Precautions on page 8 to 9 and
Safety Precautions for All Limit Switches.

Model Number Structure


Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3) (4)

(1) Built-in Switch (3) Actuator (4) Conduit/Ground Terminal *


Z : SPDT (AC) Q : Plunger None : G 1/2/without ground terminal
X : SPDT (DC) Q22 : Roller plunger G1 : G 1/2/with ground terminal
Q21 : Crossroller plunger G : Pg13.5/with ground terminal
(2) Mounting Direction QA2 : Roller arm lever SG1 : 1/2-14NPSM/with ground terminal
E : Side mounting QA277 : One-way action roller arm lever YG1 : M20/with ground terminal
V : Base mounting N : Sealed plunger S : 1/2-14NPSM/without ground terminal
V2 : Diagonal side mounting N22 : Sealed roller plunger (ZE, ZV, ZV2 only) Y : M20/without ground terminal
N21 : Sealed crossroller plunger (ZE, ZV, ZV2 only)
NA2 : Sealed roller arm lever
NA277 : Sealed one-way action roller arm lever
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.

1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting Base mounting Diagonal side mounting

Mounting

Approved Approved Approved


Actuator Model standards Model standards Model standards
UL CSA UL CSA UL CSA
AC ZE-Q-2   ZV-Q-2   ZV2-Q-2  
Plunger
DC XE-Q-2 XV-Q-2 XV2-Q-2

AC ZE-Q22-2   ZV-Q22-2   ZV2-Q22-2  


Roller plunger
DC XE-Q22-2 XV-Q22-2 XV2-Q22-2

AC ZE-Q21-2   ZV-Q21-2   ZV2-Q21-2  


General
Crossroller plunger
purpose
DC XE-Q21-2 XV-Q21-2 ---

AC ZE-QA2-2   ZV-QA2-2   ZV2-QA2-2  


Roller arm lever
DC XE-QA2-2 XV-QA2-2 XV2-QA2-2

AC ZE-QA277-2   --- ZV2-QA277-2  


One-way action roller
arm lever
DC XE-QA277-2 --- ---

AC ZE-N-2   ZV-N-2   ZV2-N-2  


Sealed plunger
DC XE-N-2 XV-N-2 XV2-N-2

Sealed roller plunger AC ZE-N22-2   ZV-N22-2   ZV2-N22-2  

Sealed crossroller
Sealed AC ZE-N21-2   ZV-N21-2   ZV2-N21-2  
plunger
(Booted)
AC ZE-NA2-2   ZV-NA2-2   ZV2-NA2-2  
Sealed roller arm lever
DC XE-NA2-2 XV-NA2-2 XV2-NA2-2

AC ZE-NA277-2   ZV-NA277-2   ZV2-NA277-2  


One-way action
sealed roller arm lever
DC XE-NA277-2 --- XV2-NA277-2

Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.

Specifications
Approved Standards
Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No.14 LR45746
Contact your OMRON
CCC (CQC) GB/T14048.5
representative for details.
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.

Ratings
Non-inductive load (A) Inductive load (A) Inrush NC 30 A max.
Rated current
Model Resistive load Lamp load Inductive load Motor load NO 15 A max.
voltage
NC NO NC NO NC NO NC NO
125 VAC 15 3 1.5 15 5 2.5
ZE-@ 250 VAC 15 2.5 1.25 15 3 1.5
ZV-@ 480 VAC 10 1.5 0.75 6 1.5 0.75
ZV2-@ 125 VDC 0.5 0.5 0.05 0.05
250 VDC 0.25 0.25 0.03 0.03
8 VDC 10 3 1.5 10 10 5 2.5 Note: 1. The above figures are for standard currents.
XE-@ 14 VDC 10 3 1.5 10 10 5 2.5 2. Inductive loads have a power factor of 0.4 min.
XV-@ 30 VDC 10 3 1.5 10 10 5 2.5 (AC) and a time constant of 7 ms max. (DC).
XV2-@ 125 VDC 10 3 1.5 7.5 6 2 2.5 3. Lamp load has an inrush current of 10 times
250 VDC 3 1.5 0.75 2 1.5 2 1.5 the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.

2
ZE/ZV/ZV2/XE/XV/XV2

Approved Standard Ratings Characteristics


UL/CSA Degree of protection IP65 (EN60947-5-1)*1
Z@: 10,000,000 operations min.
Model Rated voltage Current Horsepower Mechanical
X@: 1,000,000 operations min.
125 VAC 15 A Durability Z@: 500,000 operations min., for 15 A,
1/8HP
250 VAC 15 A *2 250 VAC resistive load
1/4HP Electrical
ZE 480 VAC 15 A X@: 100,000 operations min., for 10 A,
125 VDC 0.5 A 125 VDC resistive load
---
250 VDC 0.25 A Plunger type: 0.01 mm/s to 0.5 m/s
Operating speed
Lever type: 0.02 mm/s to 0.5 m/s
CCC (GB/T14048.5) Operating Mechanical 120 operations/min
frequency Electrical 20 operations/min
Applicable category and ratings Rated frequency 50/60 Hz
AC-12 10 A/250 VAC Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value)
Terminal temperature rise 50°C max.
Between terminals
1,000 VAC, 50/60 Hz for 1 min
of the same polarity
Between current-
Z@: 2,000 VAC, 50/60 Hz for 1 min
carrying metal
Dielectric X@: 1,500 VAC, 50/60 Hz for 1 min
part and ground
strength
Between each
terminal and Z@: 2,000 VAC, 50/60 Hz for 1 min
non-current-car- X@: 1,500 VAC, 50/60 Hz for 1 min
rying metal part
Vibration
Malfunction 10 to 55 Hz, 1.5-mm double amplitude*3
resistance
Shock Destruction 1,000m/s2 max.
resistance 100 m/s2 max.*4
*3 Malfunction
50 m/s2 max.*5
Ambient operating temperature −10°C to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Ambient operating humidity
Sealed type: 35% to 95%RH
Weight Approx. 260 to 280 g
Note: The above figures are initial values.
*1. IP65 for @-N models and IP60 for @-Q models. The degree of protection is
tested using the method specified by the standard (EN60947-5-1). Confirm
that sealing properties are sufficient for the operating conditions and
environment beforehand.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.

Engineering Data
Electrical Durability
ZE (cosφ = 1)
Durability (x 104 operations)

Operating frequency:
20 operations/min
OT: Full stroke

1,000
125 VAC
500
250 VAC

100
480 VAC
50

0 2 4 6 8 10 12 14 16
Switching current (A)

ZE (cosφ = 0.4)
Durability (x 104 operations)

Operating frequency:
20 operations/min
OT: Full stroke

1,000
125 VAC
500
250 VAC
480 VAC

100

50

0 2 4 6 8 10 12 14 16
Switching current (A)

3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure Contact Form
ZE-NA2-2
COM NC

NO
Pin plunger
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
Tightening band
+ terminal.
Case Rubber cap (CR)

Separator
Built-in switch
Terminal

Conduit Cover Seal rubber (NBR)


opening
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.

Dimensions and Operating Characteristics (Unit: mm)

Side Mounting Models

Plunger Roller Plunger


12.7 dia. × 4.8 * PT
ZE-Q-2 12R * JIS B0202 G1/2
Effective thread:
PT ZE-Q22-2 JIS B0202 G1/2
Effective thread:
XE-Q-2 4 threads min.
17
XE-Q22-2 4 threads min.
Two, M4 17
OP Two, M4 OP
(length: 45) (length: 45)
19 19

23 25.5 25.5
23

2.1±0.1 2.1±0.1
25.4±0.3 25.4±0.3
24 24
25.4±0.12 25.4±0.12
86 86
* Stainless steel plunger * Stainless steel roller

Crossroller Plunger Roller Arm Lever 19.1 dia. × 7.9 *1


39.7
*2

ZE-Q21-2 12.7 dia. × 4.8 * PT ZE-QA2-2 (23.1)


XE-Q21-2 JIS B0202 G1/2
Effective thread:
XE-QA2-2 JIS B0202 G1/2
Effective thread:
4 threads min. 4 threads min. PT
17 17
Two, M4 OP
Two, M4 44±0.8
(length: 45) 19.3
(length: 45) 19
19

23 25.5
23 25.5

2.1±0.1
2.1±0.1
25.4±0.3
25.4±0.3 24
24 25.4±0.12
25.4±0.12 86
86
*1. Stainless sintered roller
* Stainless steel roller
*2. Adjustable between 0° and 225°

Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.


2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)

Operating
Model ZE-Q-2 XE-Q-2 ZE-Q22-2 XE-Q22-2 ZE-Q21-2 XE-Q21-2 ZE-QA2-2 XE-QA2-2
characteristics
Operating force OF 2.45 to 3.43 N 5.00 N max. 2.45 to 3.43 N 5.00 N max. 2.45 to 3.43 N 5.00 N max. 5.59 N max. 6.47 N max.
Release force RF min. 1.12 N 1.12 N 1.12 N 1.12 N 1.12 N 1.12 N 1.67 N 1.67 N
Pretravel PT max. 0.4 mm 0.9 mm 0.5 mm 0.9 mm 0.5 mm 0.9 mm 4 mm 6 mm
Over Travel OT min. 5.5 mm 5.5 mm 3.6 mm 3.6 mm 3.6 mm 3.6 mm 6 mm 5.5 mm
Movement Differential MD max. 0.05 mm 0.47 mm 0.05 mm 0.47 mm 0.05 mm 0.47 mm 0.4 mm 0.72 mm
Operating Position OP 38.2±0.8 mm 49.7±1 mm 49.7±1 mm ---

4
ZE/ZV/ZV2/XE/XV/XV2

One-way Action Roller Arm Lever Sealed Plunger


ZE-QA277-2 18.7 dia. × 9 *1
ZE-N-2
XE-QA277-2 Operate in this XE-N-2
direction only

(40) 39.7 *2
17.4R 12R * JIS B0202 G1/2 PT
JIS B0202 G1/2 Effective thread:
Effective thread: 4 threads min.
4 threads min. PT
17 17
Two, M4 44±0.8 Two, M4 OP
(length: 45) (length: 45)
19.3 19
19

23 25.5 23 25.5

2.1±0.1 2.1±0.1
25.4±0.3 25.4±0.3
24 24
25.4±0.12 25.4±0.12
86 86
*1. Stainless sintered alloy roller * Stainless steel plunger
*2. Adjustable between 0° and 225°

Sealed Roller Plunger Sealed Crossroller Plunger


ZE-N22-2 ZE-N21-2
12.7 dia. × 4.8 * PT 12.7 dia. × 4.8 * PT
JIS B0202 G1/2 JIS B0202 G1/2
Effective thread: Effective thread:
4 threads min. 4 threads min.
17 17
Two, M4 OP Two, M4 OP
(length: 45) (length: 45)
19 19

23 25.5 23 25.5

2.1±0.1 2.1±0.1
25.4±0.3 25.4±0.3
24 24
25.4±0.12 25.4±0.12
86 86
* Stainless steel roller * Stainless steel roller

Sealed Roller Arm Lever One-way Action Sealed Roller Arm Lever
ZE-NA2-2 ZE-NA277-2 18.7 dia. × 9 *1
Operate in this
XE-NA2-2 19.1 dia. × 7.9 *1
39.7 *2 XE-NA277-2 direction only
39.7 *2
(40)
17.4R
(23.1)
JIS B0202 G1/2
JIS B0202 G1/2 Effective thread:
Effective thread: PT 4 threads min. PT
4 threads min.
17 53.4±0.8
Two, M4 Two, M4
17 53.4±0.8
(length: 45) 19.3 (length: 45)
19 19.3
19

23 25.5 23 25.5

2.1±0.1 2.1±0.1
25.4±0.3 24 25.4±0.3
24
25.4±0.12 25.4±0.12
86 86
*1. Stainless sintered alloy roller *1. Stainless steel roller
*2. Adjustable between 0° and 225° *2. Adjustable between 0° and 225°

Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.


2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)

ZE-QA277-2 XE-QA277-2 ZE-N-2 XE-N-2 ZE-N22-2


OF max. 5.59 N 6.47 N 7.85 N 10.20 N 4.90 N
RF min. 1.67 N 1.67 N 2.35 N 2.35 N 0.98 N
PT max. 4 mm 6 mm 2 mm 3 mm 1 mm
OT min. 6 mm 5.5 mm 5 mm 4 mm 3.5 mm
MD max. 0.4 mm 0.72 mm 0.1 mm 0.47 mm 0.12 mm
OP --- 45.8±0.8 mm 49.7±0.8 mm

ZE-N21-2 ZE-NA2-2 XE-NA2-2 ZE-NA277-2 XE-NA277-2


OF max. 4.90 N 6.28 N 7.26 N 6.28 N 7.26 N
RF min. 0.98 N 2.26 N 2.26 N 2.26 N 2.26 N
PT max. 1 mm 5 mm 6 mm 5 mm 6 mm
OT min. 3.5 mm 6 mm 5.5 mm 6 mm 5.5 mm
MD max. 0.12 mm 0.4 mm 0.72 mm 0.4 mm 0.72 mm
OP 49.7±0.8 mm --- ---

5
ZE/ZV/ZV2/XE/XV/XV2

Base Mounting/Diagonal Side Mounting Models


The diagrams show the base-mounted model (ZV-@ or XV-@) on top and the diagonal side-mounted model (ZV2-@ or XV2-@) on bottom.
The flange on base-mounted models is shown with dotted lines.

Plunger Roller Plunger


ZV(2)-Q-2 t = 3 (ZV-Q-2/XV-Q-2 flange) ZV(2)-Q22-2 t = 3 (ZV-Q22-2/XV-Q22-2 flange)

XV(2)-Q-2 XV(2)-Q22-2
53R 53R
41.3±0.2 41.3±0.2
54 54

10.5±0.3 10.5±0.3
Two, 4.3±0.2 dia. 36.6 Two, 4.3±0.2 dia. 36.6

JIS B0202 G1/2 12.7 dia. × 4.8 *1 PT


Effective 26.1
12R *1 JIS B0202 G1/2
thread: 4 26.1 PT
Effective
threads min. thread: 4 threads min.
17 17 (see note 2)
(see note 1)
5 5
OP
OP
31±0.2 31±0.2
23 23
3 3
*2 75±0.2 *2
+0.2
Two, 5.4 +0.2 75±0.2
25.4±0.3 Two, 5.4 0 dia. 86
5.5
25.4±0.3
0 dia. 5.5
holes holes 86
*1. Stainless steel plunger *1. Stainless steel roller
*2. Only the ZV2-Q-2 and XV2-Q-2 incorporate *2. Only the ZV2-Q22-2 and XV2-Q22-2
mounting holes. incorporate mounting holes.

Crossroller Plunger Roller Arm Lever


ZV(2)-Q21-2 ZV(2)-QA2-2
XV-Q21-2 XV(2)-QA2-2
t = 3 (ZV-QA2-2/XV-QA2-2 flange)
t = 3 (ZV-Q21-2/XV-Q21-2 flange)

53R
53R
41.3±0.2 41.3±0.2 54
54

10.5±0.3
10.5±0.3 Two, 4.3±0.2 dia. 36.6
Two, 4.3±0.2 dia. 36.6
19.1 dia. × 7.9 *1
39.7 *2
JIS B0202
G1/2
12.7 dia. 4.8 *1 26.1 PT Effective 23.1 max.
JIS B0202 G1/2 thread: 4
Effective threads min.
thread: 4 threads min. PT
17 30±0.8
17 (see note 3) 19.3
5
5
OP 69.5±0.8
31±0.2
31±0.2
23
23
3
3 *3 75±0.2
*2 Two, 5.4 +0.2
0 dia. 5.5
+0.2 75±0.2 25.4±0.3 86
25.4±0.3 Two, 5.4 0 dia. 5.5 holes
holes 86
*1. Stainless sintered roller
*1. Stainless steel roller *2. Adjustment between 0° to 225°.
*2. Only the ZV2-Q21-2 incorporate mounting holes. *3. Only the ZV2-QA2-2 and XV2-QA2-2 incorporate mounting holes.

Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

ZV-Q-2 XV-Q-2 ZV-Q22-2 XV-Q22-2 ZV-Q21-2 ZV-QA2-2 XV-QA2-2


XV-Q21-2
ZV2-Q-2 XV2-Q-2 ZV2-Q22-2 XV2-Q22-2 ZV2-Q21-2 ZV2-QA2-2 XV2-QA2-2
OF 2.45 to 3.43 N 5.00 N max. 2.45 to 3.43 N 5.00 N max. 2.45 to 3.43 N 5.00 N max. 5.59 N max. 6.47 N max.
RF min. 1.12 N 1.12 N 1.12 N 1.12 N 1.12 N 1.12 N 1.67 N 1.67 N
PT max. 0.4 mm 0.9 mm 0.5 mm 0.9 mm 0.5 mm 0.9 mm 4 mm 6 mm
OT min. 5.5 mm 5.5 mm 3.6 mm 3.6 mm 3.6 mm 3.6 mm 6 mm 5.5 mm
MD max. 0.05 mm 0.47 mm 0.05 mm 0.47 mm 0.05 mm 0.47 mm 0.4 mm 0.72 mm
63.7±0.8 mm (see note 1) 75.2±0.8 mm (see note 2) 75.2±0.8 mm (see note 3)
OP ---
(ZV-Q-2, XV-Q-2) (ZV-Q22-2, XV-Q21-2) (ZV-Q22-2, XV-Q21-2)
Note: 1. OP for ZV2-Q-2 and XV2-Q-2 is 24.2 ±0.8 mm.
2. OP for ZV2-Q22-2 and XV2-Q22-2 is 35.7 ±1 mm.
3. OP for ZV2-Q21-2 is 35.7 ±0.8 mm.

6
ZE/ZV/ZV2/XE/XV/XV2

One-way Action Roller Arm Lever Sealed Plunger


ZV2-QA277-2 ZV(2)-N-2
XV(2)-N-2

t=3 (ZV-QA277-2 flanges)


t = 3 (ZV-N-2/XV-N-2 flange)

53R
41.3±0.2 53R
54 41.3±0.2
54

10.6±0.3
10.6±0.3
18.7 dia. 9 *1 Two, 4.3±0.2 dia. holes 36.6
Two, 4.3±0.2 dia. holes 36.6
Operates in this
direction only
(40) 39.7 *2
JIS B0202 G1/2 R17.4
Effective PT
12CR *1 JIS B0202 G1/2 26.1
thread: 4
Effective
threads min.
PT thread: 4 threads min.
17 30±0.8
19.3 17 (see note 1)
5
69.5±0.8 5

31±0.2 OP
31±0.2
23
23
3
*3 3
+0.2 75±0.2
*2 75±0.2
25.4±0.3 Two, 5.4 0 dia. 86
5.5
holes 25.4±0.3 Two, 5.4 0 dia.
+0.2 5.5
holes 86
*1. Stainless steel roller
*2. Adjustment between 0° to 225°. *1. Stainless steel plunger
*3. Only the ZV2-QA277-2 incorporate mounting holes *2. Only the ZV2-N-2 and XV2-N-2 incorporate mounting holes.

Sealed Roller Plunger t = 3 (ZV-N22-2 flange) Sealed Crossroller Plunger t = 3 (ZV-N21-2 flange)
ZV(2)-N22-2 ZV(2)-N21-2

53R 53R
41.3±0.2 41.3±0.2
54 54

10.6±0.3 10.6±0.3
Two, 4.3±0.2 dia. holes 36.6 Two, 4.3±0.2 dia. holes 36.6

12.7 dia. × 4.8 *1 PT 12.7 dia. × 4.8 *1


26.1 26.1 PT
JIS B0202 JIS B0202 G1/2
G1/2 Effective Effective
thread: 4 threads min. thread: 4 threads min.
(see note 2) (see note 3)
17 17
5 5
OP OP
31±0.2 31±0.2
23 23
3 3
*2 75±0.2 *2 75±0.2
25.4±0.3 Two, 5.4 +0.2 dia. 5.5 5.5
0 86 25.4±0.3 Two, 5.4 +0.2
0 dia. 86
holes holes
*1. Stainless steel roller *1. Stainless steel roller
*2. Only the ZV2-N22-2 incorporate mounting holes. *2. Only the ZV2-N21-2 incorporate mounting holes.

Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

ZV-N-2 XV-N-2 ZV-N22-2 ZV-N21-2


ZV2-QA277-2
ZV2-N-2 XV2-N-2 ZV2-N22-2 ZV2-N21-2
OF max. 5.59 N 7.85 N 10.20 N 4.90 N 4.90 N
RF min. 1.67 N 2.35 N 2.35 N 0.98 N 0.98 N
PT max. 4 mm 2 mm 3 mm 1 mm 1 mm
OT min. 6 mm 5 mm 4 mm 3.5 mm 3.5 mm
MD max. 0.4 mm 0.1 mm 0.47 mm 0.12 mm 0.12 mm
75.2±0.8 mm 75.2±0.8 mm
71.4±0.8 mm (see note 1)
OP --- (see note 2) (see note 3)
(ZV-N-2, XV-N-2)
(ZV-N22-2) (ZV-N21-2)
Note: 1. OP for ZV2-N-2 and XV2-N-2 is 31.9 ±0.8 mm.
2. OP for ZV2-N22-2 is 35.7 ±0.8 mm.
3. OP for ZV2-N21-2 is 35.7 ±0.8 mm.

7
ZE/ZV/ZV2/XE/XV/XV2

Sealed Roller Arm Lever One-way Action Sealed Roller Arm Lever
ZV(2)-NA2-2 ZV(2)-NA277-2
XV(2)-NA2-2 XV2-NA277-2

t=3 (ZV-NA277-2 flanges)


t=3 (ZV-NA2-2/XV-NA2-2 flanges)

53R
53R 41.3±0.2
54
41.3±0.2 54

Two, 4.3±0.2 dia. holes


18.7 dia. 9 *1 10.6±0.3
10.6±0.3
36.6
Two, 4.3±0.2 dia. 36.6 Operates in this
19.1 dia. × 9 *1 39.7 direction only
39.7 *2 (40) *2
17.4R
JIS B0202 JIS B0202
G1/2 (23.1) G1/2
Effective Effective
thread: 4 thread: 4 PT
PT threads min.
threads min. 19.3 39.5±0.8
17
17
19.3 39.5±0.8
5
5 79±0.8
79±0.8
31±0.2
31±0.2
23
23 3
3 *3
+0.2
75±0.2
75±0.2 5.5
*3
5.5 25.4±0.3 Two, 5.4 0 dia. 86
25.4±0.3 Two, 5.4 0 dia.
+0.2 holes
86
holes *1. Stainless steel roller
*1. Stainless sintered alloy roller *2. Adjustment between 0° to 225°.
*2. Adjustment between 0° to 225°. *3. Only the ZV2-NA277-2 and XV2-NA277-2 incorporate
*3. Only the ZV2-NA2-2 and XV2-NA2-2 incorporate mounting holes. mounting holes.

Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

ZV-NA2-2 XV-NA2-2 ZV-NA277-2


XV2-NA277-2
ZV2-NA2-2 XV2-NA2-2 ZV2-NA277-2
OF max. 6.28 N 7.26 N 6.28 N 7.26 N
RF min. 2.26 N 2.26 N 2.26 N 2.26 N
PT max. 5 mm 6 mm 5 mm 6 mm
OT min. 6 mm 5.5 mm 6 mm 5.5 mm
MD max. 0.4 mm 0.72 mm 0.4 mm 0.72 mm

Safety Precautions
Refer to Safety Precautions for All Limit Switches.

Precautions for Correct Use


Operating Environment • Install Switches where they will not be directly subject to cutting
• Seal material may deteriorate if a Switch is used outdoor or where chips, dust, or dirt. The Actuator and Switch must also be protected
subject to special cutting oils, solvents, or chemicals. Always from the accumulation of cutting chips or sludge.
appraise performance under actual application conditions and set Not Suitable Suitable
suitable maintenance and replacement periods.
• Be sure to protect part A with grease in order to maintain the
mechanical durability and performance of the Limit Switch. The use
of molybdenum disulfide grease is recommended.

• Constantly subjecting a Switch to vibration or shock can result in


wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.

8
ZE/ZV/ZV2/XE/XV/XV2

Mounting Mounting
• With the Roller Lever-type Enclosed Switches, the roller arm has Mounting Holes
been temporarily tightened prior to shipment, so that its position
may be adjusted later. When mounting the Switch, be sure to re- Side Mounting Bottom Mounting
Two, 4.3 dia. Two, 4.3 dia.
tighten the roller arm so as to prevent it from becoming loose during mounting holes or mounting holes or
operation. M4 screw holes M4 screw holes

• To adequately maintain the seals at the mounting screw section on


the side of the Enclosed Switch, insert each O-ring correctly and 25.4±0.1
secure it with the lock nut. 41.3±0.15
• To provide the Switch with improved sealing property, use of the SC Side Diagonal Mounting
Two, 5.4 dia.
Connector is recommended. Refer to Limit Switch Connectors for mounting holes or
details on SC Connectors. M5 screw holes

• When routing wires into the conduit opening, be sure that cuttings
and other foreign matter do not enter the Switch. 31±0.1

Appropriate Tightening Torque


A loose screw may result in a malfunction. Be sure to tighten each 75±0.1
screw to the proper tightening torque as shown below.
Operation
No. Type Appropriate tightening torque
1 Cover mounting screw 1.18 to 1.37 N·m
• Operating method, shape of cam or dog, operating frequency, and
the overtravel (OT) have significant effect on the service life and
2 Switch mounting screw*1 1.18 to 1.37 N·m
precision of the Limit Switch. Make sure that the shape of the cam
3 Switch mounting screw*2 4.90 to 5.88 N·m
is smooth enough.
Switch terminal screw
4
(M4 screws)
0.78 to 1.18 N·m • Check that OT has a sufficient margin. The actual OT should be
5 Roller arm mounting nut 4.90 to 5.88 N·m
rated OT x 0.7 to 1.
*1. This torque range applies to side mounting or bottom mounting. (M4 screws) Dedicated Wrench
*2. This torque range applies to diagonal side mounting. (M5 Allen-head bolt)
1. The roller arm can be set freely within a range of 225° after
loosening the nut.
2. The roller arm mounting bracket can be set in any direction after
loosening the nut.

• Make sure that the nut is free of foreign substances when the nut is
loosened.
• A dedicated wrench is provided separately.
Model
SUPANA FOR ZE

9
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.


OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.

Errors and Omissions.


Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

2024.3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2024 All Right Reserved.

You might also like