Model ATC-106N 2.

9 Connection Diagram
RS-232 to RS-485 Interface Converter
2.4 Sending Control 3.0 ATC-106N connecting other RS-485 device
User's Manual
ATC-106N does not need RTS to control the RS-485 driver. ATC-106N RS-485 device
The RS-485 driver is automatically enabled during each DB-9 Male
spacing state of SD line (also called TD) on the RS-232 side. PIN1(485-)----------------------- 485-
The ATC-106N has an internal connection to prevent data PIN2(485+)-----------------------485+
transmitted from the RS-232 port from being echoed back to PIN3(GND)-----------------------GND
the RS-232 port. The ATC-106N is used as a two wire (half
duplex) RS-485 Converter.

2.5 Operating Distance


1.0 General Description
Data Rate (KBPS): 19.2 9.6 4.8 2.4
The ATC-106N is a 2 channel non-power SD Control
Maximum Distance (feet): 4,000 6,000 8,000 10,000
RS-232 to RS-485 interface converter.ATC-106N can
(using 24 AWG wire)
convert the TD and RD signals of RS-232 into balanced
half-duplex RS-485 signals.
2.6 Power
2.0 Specifications
ATC-106N is powered from the RS-232 data TD or handsh-
2.1 Interface
ake lines. It will try to get its power from RTS or DTR (at
Conforms to EIA RS-232 and RS-485 standards
least +5.5V or -5.5V in the quiescent state). If there are no
2.2 Connectors and signals
RS-232 control signals (DTR or RTS) available. ATC-106N
The ATC-106N has a DB-9 female connector on the RS-232
will get power from the data input TD pin (at least -5.5V in
side and DB-9 male connector or a terminal block connector
the quiescent state). For this kind of power stealing devices ,
on the RS-485 side.
the sufficient power is needed to operate the device. In
RS-232 Side:
some case maybe no handshake lines are available and the
Connector: DB-9 Female.
TD can not drive ATC-106N, then an external 5VDC/40mA
Signals: Use Pins 3 (TD also called SD) and 2 (RD) Pins 7
power supply can be connected to two terminals on the
(RTS) and 8 (CTS) are tied together Pins 4 (DTR), 6 (DSR),
RS-485 connector between terminals +5VDC and GND .
and 1 (CD) are tied together.
RS-485 Side: Connector: DB-9 male connector or
2.7 Dimensions : 88mmx33mmx17mm
6 position terminal block -- 485+.485-.+5V.GND .

2.8 Environment : -20° to 70° C, 5% to 95% relative


2.3 Data Rate : 300 to 115.2 KBPS, up to 4,000 feet at
humidity
19,200 BPS.