Site Survey Report
TECHNICAL SITE SURVEY REPORT
SITE NAME: SHELL KAPAR KELANG
LRD: SH7Z
Revision No: 1.1
Survey Date: 7 December 2022
Survey PIC Name: Md. Amar Firdaus
Survey PIC Contact: +601133222270
Region: Central (Selangor)
Client: Maxis
Site Survey Report
Proposed New 15m Monopole Due To Heavy
Blockage
Above picture show 15m monopole height
Below picture show exactly proposed location
Site Survey Report
TABLE OF CONTENTS
1. OBJECTIVE
2. SITE INFORMATION
2.1 CLIENT SITE
2.2 MASTER SITE
2.3 LINK PROFILE
3. SITE SURVEY INFORMATION
3.1 LINE OF SITE
3.2 CABLING
3.3 RACKING SYSTEM
3.4 BRACKET / MOUNTING TYPE
3.5 RADIO INSTALLATION
3.6 POWER SUPPLY
3.7 GROUNDING
3.8 GOOGLE MAP
3.9 NETWORK DIAGRAM / SCHEMATIC DESIGN
4. DEVELOPMENT INFORMATION
4.1 MASTER SITE
4.2 CLIENT SITE
5. PHOTOS
6. ADDIOTIONAL COMMENTS
7. ACCEPTANCE MEMORANDUM
Site Survey Report
1. OBJECTIVE
A site survey was carried out at SHELL KAPAR KELANG. The survey includes
the gathering of information for cabling routes and antenna mounting together
with all other necessary information to ensure a successful wireless installation.
2. SITE INFORMATION
2.1 Client Site
GPS Antenna Height
No Site Name and Address
Coordinates (AGL)
SHELL KAPAR KELANG
LRD: SH7Z
Address: H.S. (D) 135891, Persiaran
3.13698,
1 Hamzah Alang, Taman 15 meter
101.40370
Perindustrian Meru, 40150 Klang,
Selangor
2.2 Master Site
No Site Name and Address GPS Antenna Height
Coordinates (AGL)
1 Maxis_BSKP
Address: Jalan Bukit Kapar, 42200 3.14780, 41 meter
Kapar, Selangor 101.38550
Secondary FE not recommended due to heavy blockage.
Site Survey Report
2.3 Link Profile
Site Survey Report
3. SITE SURVEY INFORMATION
3.1 Line of Sight
Line of Sight
Near Line of Sight
No Line of Sight
3.2 Cabling
Copper Cabling Master Site – BSKP Client Site – SH7Z
Cable Type Outdoor Cat5e Outdoor Cat5e
Outdoor Cat6 Outdoor Cat6
Cable Length 60 Meter 45 Meter
Conduit Type UPVC UPVC
GI Conduit GI Conduit
Existing Cable Tray Existing Cable Tray
3.3 Racking Systems
Location Master Site – BSKP Client Site – SH7Z
Existing Rack Existing Rack
Rack Option
New Rack New Rack
6U 6U
9U 9U
Rack Size 24U 24U
48U 48U
Wall Mount Wall Mount
Rack Mount
Floor Mount Floor Mount
Indoor Indoor
Rack Type
Outdoor Outdoor
Site Survey Report
3.4 Bracket / Mounting Type
Location Master Site – BSKP Client Site – SH7Z
Standard Standard
Bracket/Mounting Type
Customized Customized
Astro Mount Astro Mount
Standard Tower Mount Tower Mount
Bracket/Mounting Floor Mount Floor Mount
Wall Mount Wall Mount
Proposed New 1m Proposed New 0.5m
Details of
Boom With Tower Boom With Tower
Bracket/Mounting
Mounted Bracket Mounted Bracket
Customized
Bracket/Mounting
3.5 Radio Installation
Radio BSKP – SH7Z SH7Z – BSKP
Height (m AGL) 41m 15m
Azimuth (Deg N) 120° 300°
Radio Brand and Type BreezeAir/2x2 BreezeAir/2x2
Location of Antenna Tower Monopole
Antenna Size 0.4 0.4
3.6 Power Supply
Power Supply Master Site – BSKP Client Site – SH7Z
Power Supply Source Rectifier 3 pin socket
AC AC
Power Supply Type
DC DC
Location of Power Tap Inside Cabin Inside Office
DC Breaker Details New - 1x6A N/A
3.7 Grounding
Grounding Master Site – BSKP Client Site – SH7Z
Grounding Tap Existing Point Existing Point
Grounding 16mm 16mm
Grounding Cable Length 10m 10m
Site Survey Report
3.8 Google Map View
Site Survey Report
3.9 Network Design / Schematic Design
BSKP
Master Site
SH7Z
Client Site
SH7Z
Meraki MX67
Site Survey Report
4. DEPLOYMENT INFORMATION
4.1 Master Site
Skylift required? Yes, Height = No
Ladder required? Yes, Height =3m No
Scaffolding required? Yes, Height = No
Other:
Remarks:
4.2 Client Site
Sky lift required? Yes, Height = 30m No
Ladder required? Yes, Height = 3m No
Scaffolding required? Yes, Height = No
Other:
Remarks:
Site Survey Report
5. PHOTOS
5.1 NLOS View
5.1.1 NLOS from Client Site SH7Z-BSKP
NLOS PHOTO
NLOS PHOTO - ZOOM
Site Survey Report
5.1.2 NLOS View from Master Site
NLOS PHOTO
NLOS PHOTO - ZOOM
LRD Structure Type, Ht Latitude Longtitude Azimuth Status
BSKP Tower, 41m 3.1478° 101.3855° 300° Near Line
Of Sight
Site Survey Report
5.2 Client Site
5.2.1 Bracket/Mounting Location
Proposed New 15m Monopole with 0.5m Boom
5.2.3 Cable Route
Cable Route 1
Site Survey Report
Cable Route 2 Cable Route 3
Cable Route 4 Cable Route 5
Site Survey Report
5.2.4 Racking System
Proposed Rack Location
5.2.5 Power Socket Location
Proposed Power Socket Location
Site Survey Report
5.3 Master Site
5.3.1 Master Site View
Proposed to install antenna location at 41 meter height
Site Survey Report
5.3.2 Bracket / Mounting Location
Proposed Bracket/Mounting Location
5.3.3 Cable Route
1. Cable Route 2. Cable Route
Site Survey Report
3. Cable Route 4. Cable Route
5.3.4 Racking System
Proposed Equipment Location
Site Survey Report
5.3.5 Power Supply
Existing Power Existing Equipment
Proposed DC Tap Location Grounding Tap Location
Site Survey Report
5.3.6 Panoramic View
0° View 30° View
60° View 90° View
120° View 150° View
Site Survey Report
180° View 210° View
240° View 270° View
300° View 330° View
Site Survey Report
6. ADDITIONAL COMMENTS
Site Survey Report
7. BILL OF MATERIALS
Description Master Site Client Site
Wireless Model BREEZEAIR BREEZEAIR
PoE Adapter / PIDU DC POE AC POE
Surge Suppressor / LPU BREEZE GUARD BREEZE GUARD
Outdoor Cat6 Length (m) 60m 45m
Conduit Type (GI/PCV) - 5m PVC
Conduit Length (m) - 5m GI Conduit
Fiber No of Core, Length -
Fiber Type (SM/MM) -
Fiber Connector Type -
Rack Size (6U/9U/12U/24U/42U) -
Rack Mount (Wall/Floor) -
Rack Type (Indoor/Outdoor) -
Bracket Type, Length Proposed New 1m Proposed New
Boom With Tower 0.5m Boom With
Mounted Bracket Tower Mounted
Bracket
Power Cable Length -
RJ45 6 6
Patch Cord -
Grounding Cable (16mm2) 10M 10M
Grounding Cable Lug (16mm) 6 6
Power Cable R/B (2.5mm2) 5
DC Breaker 6A 1
Others: -
Others: -
Others: -
Others: - -
Site Survey Report
8. ACCEPTANCE MEMORANDUM
Description:
To be completed by client’s representative(s) and Telefina Partners in all
applicable fields, to certify that all tests in the form were successfully completed
and the supplied equipment and/or system conform to the contractual
specifications.
CONTRACT
INDENT NO
REGION
STATION
DATE
OUTSTANDING ITEMS: YES / NO
(List of outstanding items attached, if any)
VERIFIED BY:
COMPANY
NAME: ____________________________________
DESIGNATION: ____________________________________
SIGNATURE: ____________________________________
DATE: ____________________________________
COMPANY
NAME: ____________________________________
DESIGNATION: ____________________________________
SIGNATURE: ____________________________________
DATE: ____________________________________
COMPANY
NAME: ____________________________________
DESIGNATION: ____________________________________
SIGNATURE: ____________________________________
DATE: ____________________________________
COMPANY
NAME: ____________________________________
DESIGNATION: ____________________________________
SIGNATURE: ____________________________________
DATE: ____________________________________