0% found this document useful (0 votes)
45 views1 page

Oilon Burners Brochure8

Uploaded by

Abbas Amirifard
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views1 page

Oilon Burners Brochure8

Uploaded by

Abbas Amirifard
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CONTROL SYSTEMS WD100 WD200 WD1000 WD2000

OPERATIONAL PRINCIPLE Electronic fuel/air Electronic fuel/air Electronic fuel/air Electronic fuel/air
CONTROL UNIT Siemens LMV51 Siemens LMV52 Lamtec control unit Siemens PLC
AVAILABLE FOR FUELS LFO LFO LFO LFO
HFO HFO HFO HFO
GAS GAS GAS GAS
LFO/GAS LFO/GAS LFO/GAS LFO/GAS
HFO/GAS HFO/GAS HFO/GAS HFO/GAS
ATOMIZING TYPE Pressure atomizing Pressure atomizing Air/steam atomizing Air/steam atomizing
O2 CONTROL Not available Optional Included Included
CO CONTROL Not available Not available Optional Not available
VSD CONTROL Not available Optional Included Included
CONTROL PANEL INTERFACE Text display Text display Text display Touch panel
(Touch panel, option)
EXTERNAL COMMUNICATION Hardwired+Modbus Hardwired+Modbus Hardwired Hardwired+Profibus
Profibus (optional) Profibus (optional) (+ optional fieldbus) (or optional fieldbus)
CAPACITY CONTROL Built in. Built in. Built in. Built in.
Pressure/Temperature Pressure/Temperature Pressure/Temperature or Pressure/Temperature or
external reference external reference
FGR Not available Optional Optional Optional
CONTROL PRINCIPLE Position control Position control Position control Position control / Flow control
SIMULTANEOUS FIRING Not available Not available Optional Included
SUPPLY VOLTAGE TO BMS 110 or 240 VAC 110 or 240 VAC 110 or 240 VAC 110 or 240 VAC
HAZARDOUS AREA CLASSIFICATION FOR Not available Not available Optional * Optional *
THE SYSTEM
* BMS cabinet itself isn’t classified

14

WiseDrive (WD), Electronic burner management system


– an energy-efficient and environmentally friendly solution
Oilon WiseDrive system brings the benefits of lower flue gas emissions, decreased consumption of energy and
improved technical features of the burner, such as more precise regulation. WiseDrive includes electrical control
sequences, fuel/air ratio and capacity control as well as all the needed functions for safe and reliable operation. The
right safety level and the need for redundant system will be taken into account to meet the requirements of the
process. Oilon WiseDrive systems are factory tested (FAT) to guarantee smooth and fast start-up of the combustion
equipment in the plant.
.