Date: 8/29/2016
PSI 4.3L (4X) Rev: A
Units 4.3L
EMERGENCY STANDBY Std Metric 1500 1800
General Engine Data
Type N/A V-Type 4 Cycle
Number of cylinders N/A 6
Aspiration N/A Naturally Aspirated
Bore in mm 4 101.6 4 101.6
Stroke in mm 3.48 88 3.48 88
Displacement in^3 L 262 4.3 262 4.3
Compression Ratio N/A 9.8:1
RPM Range (Min-Max) RPM 1500-1800
Rotation Viewed from Flywheel
N/A Counter Clockwise
Firing Order
N/A 1-6-5-4-3-2
Dry Weight (long Block) lb kg 430 195 430 195
1,2,3 HP KW HP KW
Gross Standby Power Rating Per ISO 3046 at the Flywheel
LPG 68.04 50.74 82.16 61.27
NG 64.69 48.24 78.02 58.18
Please ask a PSI sales representative for information regarding prime power operation
Exhaust System
Type Air Cooled Manifold
Emergency Standby Rating Catalyst Configuration for US Certified Product No Catalyst No Catalyst
Maximum allowable Back pressure in HG kPa 3 10.2 3 10.2
Exhaust Volumetric Flow at Rated Power @ 1350 F cfm m^3/min 301.6 8.54 361.9 10.25
Air Induction System
Maximum allowable Intake Air Restriction with Air Cleaner
Clean inH2O kPa 3 1.49 3 1.49
Dirty inH2O kPa 13 3.24 13 3.24
Combustion Air required (volume) cfm m^3/min 93.40 2.64 112.10 3.17
Cooling System
Coolant Capacity
Engine only qts L 7.75 7.3 7.75 7.3
Heat rejected to Cooling water at rated Load btu/min kcal/sec 2050 8.61 2300 9.66
Cracking Temperature F C 160 71 160 71
Full Open Temperature F C 185 85 185 85
Lubrication System
Oil Specification SAE 5W-30 API Rating of SM or Newer
Maximum Allowable Oil Temperature F C 250 121 250 121
Engine Oil Capacity
Min Qts L 4.5 4.25 4.5 4.25
Max Qts L 4.5 4.25 4.5 4.25
Fuel System
Fuel Consumption @ Rated Load
NG lb/hr kg/hr N/A N/A N/A N/A
LPG lb/hr kg/hr 24.29 11.02 28.93 13.12
Maximum EPR Rated Pressure psi kPa 1.0 6.9 1.0 6.9
Recommended Maximum Running pressure to Electronic Pressure Regulator (EPR) inH2O kPa 11.0 2.7 11.0 2.7
Recommended Minimum Running pressure to EPR inH2O kPa 7.0 1.7 7.0 1.7
Minimum NG Supply Pipe Size 1-1/4" NPT
Minimum LPG Supply Pipe Size4
3/4"
1
Standby and overload ratings based on ISO 3046. See PSI technical standard 3630000A for additional duty cycle and engine rating information
2 o
All ratings are gross flywheel horsepower corrected to 77 F at an altitude of 328feet with no cooling fan or alternator losses using
heating value for NG of 1015 BTU/SCF.
3
Production tolerances in engines and installed components can account for power variations of +/- 5%. Altitude, temperature and
excessive exhaust and intake restrictions should be applied to power calculations.
4
The preceeding pipe sizes are only suggestions and piping sizes may vary with temperature, pressure, distance from supply and
application of local codes. Gas must be available at adequate volume and pressure for engine at the EPR.
For information not listed in this document, please contact you PSI sales representative
Date: 1/16/2017
PSI 4.3L (4X) Rev: A
Units 4.3L
NON-EMERGENCY "PRIME" Std Metric 1500 1800
General Engine Data
Type N/A V-Type 4 Cycle
Number of cylinders N/A 6
Aspiration N/A Naturally Aspirated
Bore in mm 4 101.6 4 101.6
Stroke in mm 3.48 88 3.48 88
Displacement in^3 L 262 4.3 262 4.3
Compression Ratio N/A 9.8:1
RPM Range (Min-Max) RPM 1500-1800
Rotation Viewed from Flywheel
N/A Counter Clockwise
Firing Order
N/A 1-6-5-4-3-2
Dry Weight (long Block) lb kg 430 195 430 195
1,2,3 HP KW HP KW
Gross Prime Power Rating Per ISO 3046 at the Flywheel
LPG 61.24 45.68 73.94 55.16
NG 58.22 43.43 70.22 52.38
Please ask a PSI sales representative for information regarding standby power operation
Exhaust System
Type Air Cooled Manifold
Non-Emergency Prime Rating Catalyst Configuration for US Certified Product Single Substrate Single Substrate
Maximum allowable Back pressure in HG kPa 3 10.2 3 10.2
Exhaust Volumetric Flow at Rated Power @ 1350 F cfm m^3/min 301.6 8.54 361.9 10.25
Air Induction System
Maximum allowable Intake Air Restriction with Air Cleaner
Clean inH2O kPa 3 1.49 3 1.49
Dirty inH2O kPa 13 3.24 13 3.24
Combustion Air required (volume) cfm m^3/min 93.40 2.64 112.10 3.17
Cooling System
Coolant Capacity
Engine only qts L 7.75 7.3 7.75 7.3
Heat rejected to Cooling water at rated Load btu/min kcal/sec 2050 8.61 2300 9.66
Cracking Temperature F C 160 71 160 71
Full Open Temperature F C 185 85 185 85
Lubrication System
Oil Specification SAE 5W-30 API Rating of SM or Newer
Maximum Allowable Oil Temperature F C 250 121 250 121
Engine Oil Capacity
Min Qts L 4.5 4.25 4.5 4.25
Max Qts L 4.5 4.25 4.5 4.25
Fuel System
Fuel Consumption @ Rated Load
NG lb/hr kg/hr N/A N/A N/A N/A
LPG lb/hr kg/hr N/A N/A N/A N/A
Maximum EPR Rated Pressure psi kPa 1.0 6.9 1.0 6.9
Recommended Maximum Running pressure to Electronic Pressure Regulator (EPR) inH2O kPa 11.0 2.7 11.0 2.7
Recommended Minimum Running pressure to EPR inH2O kPa 7.0 1.7 7.0 1.7
Minimum NG Supply Pipe Size 1-1/4" NPT
Minimum LPG Supply Pipe Size4 3/4"
1
Standby and overload ratings based on ISO 3046. See PSI technical standard 3630000A for additional duty cycle and engine rating information
2 o
All ratings are gross flywheel horsepower corrected to 77 F at an altitude of 328feet with no cooling fan or alternator losses using
heating value for NG of 1015 BTU/SCF.
3
Production tolerances in engines and installed components can account for power variations of +/- 5%. Altitude, temperature and
excessive exhaust and intake restrictions should be applied to power calculations.
4
The preceeding pipe sizes are only suggestions and piping sizes may vary with temperature, pressure, distance from supply and
application of local codes. Gas must be available at adequate volume and pressure for engine at the EPR.
For information not listed in this document, please contact you PSI sales representative
Emergency Standby Power Rating: Applicable for supplying emergency power for the duration of utility power outage. There is no overload
capability for the emergency standby rating. Any use of the generator above the emergency standby rating is prohibited. Any unit operating in
parallel with a public utility is not considered emergency standby. Emergency standby engine is applicable to a variable load with a maximum
average load factor of 82% and 200 hours of operation per year. Emergency standby rating should only be applied in emergency power outages.
Prime Power Rating: Applicable for supplying electrical power in lieu of commercially purchased power or providing guaranteed standby power.
The prime power rating is applicable for variable loads with limited number of operating hours per year. The average power output shall not
exceed 75% of the prime power rating. The total time at 100% Prime power shall not exceed 500 hours per year. A 110% overload rating is
available one hour in every twelve hours with the total hours at 110% not to exceed 25 hours per year. Maximum number of hours per year is
2500.
Continuous Power Rating: The continuous power rating is applicable for variable loads with unlimited number of operating hours per year. The
power output shall not exceed 75% of the prime power rating. There is no overload capability.