SK TIE4-PE-M12-V2A Part number: 275 274 034

Connection extension
Protective earthing connection SK 200E size 1 - 3

Scope of delivery

1x PE connection bit with O-ring


1x Hexagonal nut M8
1x Serrated lock washer M8
1x Washer M6
1x Spring lock washer A6
1x Hexagonal nut M6

Field of use
Optional protective earthing to meet the requirements for fixed installation according to
DIN EN 61800-5-1 for conductor cross-sections up to 10 mm² (Cu) or as second protective earthing
connection. Among other things, this is mandatory if a NORDA C Flex (SK 2xxE, size 1 to 3) frequency
inverter is wall-mounted in ATE X Zone 22 / 3D. The PE connection bit is screwed into the left or right
side of one of the 3 lower M12 option slots (6L to 8L or 6R to 8R) of the connection unit.

Dimensions

Details in
millimetres

Installation / option locations

Device series Recommended option Option locations


location

SK 200E
Frequency inverter
6R / 6L, 7R / 7L, 8R / 8L
connecting unit
SK TI4-x-2xx-x (-C)

Technical Information / Datasheet SK TIE4-PE-M12-V2A


Connection extension TI 275274034 V 1.0 3517 en
Connection extension – SK TIE 4-PE-M12-V2A

Assembly

1 Remove the M12 blind plug from one of the side option slots
st (right/left) of the frequency inverter.

2 Fasten the PE connection b it into the connection unit with the


n contact serrated lock washer and the M8 hexagon nut (tightening
d torque 6 Nm).

Connection unit - inside view


3. The protective earthing conductor with ring cable lug is fastened
with the washer, the spring lock washer and the M6 hexagon nut to
the outside of the PE-connection b it with a torque of 3 Nm.

Connection unit - outside view


Connection extension SK TIE4-PE-M12-V2A, mounted on the
connection unit of an SK 200E frequency inverter, with the
protective earthing conductor connected.

Further documentation (www.nord.com)

Document Designation

BU 0200 SK 2xxE f requency inv erter manual


TI 80-0019 The dimensioning of the
protectiv e conductor