2022 12 09 - Framing
2022 12 09 - Framing
STRONGER
T H A N S T E E L. SM
Need help with product selection, ordering, scheduling, delivery, or anything else?
Call us at 800-543-7140, or on the West Coast at 800-365-5284.
Overview 5-8
Engineering Services 5
Clip Express℠ 5
Contact Information & Locations 6
How To Use This Catalog 7-8
Drywall Framing 9-23
Sound Rated Systems 24-28
Head-of-Wall Systems 29-32
BlazeFrame Tracks 33-36
TABLE OF CONTENTS
Door and Window Framing 37-39
Bridging, Bracing and Backing 40-47
Shaftwall 48-49
Area Separation Wall 50-51
Curtain Wall Framing 52-54
Floor Framing 55-60
Index 61-62
Patents/Trademarks/Warranty 62
Code Approvals 63
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
OVERVIEW 5
Smarter engineering and technical expertise. Connections you can count on.
It’s support that extends beyond the structure itself.
We know that having the right products, at the right
From the initial design phase to jobsite installation, we time, and at the right price, is absolutely essential to
are all about providing inventive, yet practical and hands- getting the job done. ClarkDietrich Clip Express is your
on know-how to help you think outside the box—or to single source for the widest and most cost-effective
help you just get it done. array of rigid, deflection, bridging and general-purpose
clips, connectors, supports and framing hardware for
ClarkDietrich Engineering Services is a full-service commercial and residential cold-formed steel framing.
consulting firm that believes strongly in value
engineering and customer input. Our engineering fees With Clip Express, you get fully engineered, rigorously
and lead times are competitive, and our customer service tested and precision-formed connectors each and
exceeds the industry standard with consistent point-of- every time. Many of our connectors were developed
contact through our regional project managers. by, or in conjunction with, framing installers in order
to deliver high-performance products for significant
We offer Building Information Modeling (BIM) services installed savings.
that include specialty engineering collaborative design.
We support the BIM movement by offering add-on While you may find a cheaper price than ClarkDietrich,
tools that allow our products, and the rich data attached you won’t find a lower overall cost or better value. We
to them, to quickly be imported into digital designs. offer unmatched reach through numerous plants and
Our team is also comprised of LEED®-accredited engineering offices—and nationwide product availability.
professionals to consult on sustainable building design.
And because staying on schedule is crucial, we ship
• Electronically sealed shop drawings and calculations
most orders the same day they are received. We’ll get it
• Preliminary sizing and pre-bid engineering pricing
• Reference plan on large projects there when, how and where you need it. Our nationwide
• Detailed wall sections, full elevation opening manufacturing and service facilities see to that.
design and C-stud truss design
• Industry’s widest product selection available from one source
Our technical services team provides immediate • Fast delivery options meet your deadlines
response to questions ranging from general installation • Backed by the largest cold-formed steel framing
and engineering company in the world
to detailed specification requirements, and can deliver • Expert field representatives for comprehensive
one-day turnaround on technical sizing. We are experts product, installation and sales training
on industry standards such as AISI and ASTM, and a
proud member of SFIA. Our team also supports our
online product submittal system, SubmittalPro,® and
our design/engineering software is available as a free Throughout this catalog, when you see this icon next
download from www.clarkdietrich.com. to a product entry, you know the product is part of our
• Product support and typical member sizing Clip Express program.
• Framing detail recommendations
• Compliance and industry standards, such as AISI, ASTM and SFIA
• Engineering software and product submittal support
• LEED requirements support
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
6 OVERVIEW
C O N TAC T I N F O R M AT I O N
ClarkDietrich Manufacturing
and Sales Locations:
CALIFORNIA Riverside MARYLAND Baltimore
P 951.360.3500 P 410.477.4000
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
OVERVIEW 7
H OW TO U S E T H I S C ATA LO G
This catalog is designed to help you select the right PROTEC TIVE COATINGS
products or systems for your construction applications. ClarkDietrich offers a wide variety of protective coatings
For your convenience, a comprehensive index containing to meet the specific requirements of a project.
our product and system offering is also located at the back
of the catalog. Search by common names and product Non-structural products are coated to meet the
names to help you quickly find exactly what you’re requirements of AISI S220/ASTM C645, with G40 or a
looking for. protective coating with an equivalent corrosion resistance.
Equivalent coatings meet the metallic equivalency
Structural properties and load tables are available on requirement of C645 by outperforming G40 in an
our website at clarkdietrich.com. ASTM B117 salt spray test. Non-structural products
may also be ordered with enhanced coatings, such as
HOW TO IDENTIF Y OUR PRODUC T S CP60 for use in special applications. The buyer is solely
ClarkDietrich has adopted standard nomenclature responsible to assure that product is ordered to properly
established by the American Iron and Steel Institute satisfy the applicable code or specification.
(AISI) for identifying each of its products. Coding
of each member consists of four parts, in this order: Structural framing products are available with a variety
of protective coatings that meet the CP60 coating
• A number which identifies the web depth of the
member to two decimal places: 600 = 6.00," 1000 protection level requirements of AISI S200, S240 and
= 10.00," 550 = 5.50," 362 = 3.625," etc. ASTM C955. These coatings may include G60, A60,
• A letter that identifies the type of member, such as S = Stud/ AZ50 or GF30, all of which satisfy the above referenced
Joist, T = Track, U = U-channel, and F = Furring channel.
standards. CP90 coatings are an enhanced option that
• A number that defines the flange dimension in inches to two
decimal places: 162 = 1.625," 200 = 2.00," 125 = 1.25," etc.
can be requested for highly corrosive environments.
• A number following a hyphen that denotes the minimum delivered ClarkDietrich can supply a specific or enhanced coating
thickness in mils (33mils = 33/1000 inches which is approximately to meet specific project requirements when requested.
0.0329"). Minimum delivered thickness is 95% of design thickness. The buyer is solely responsible to assure that product
is ordered to properly satisfy the applicable code or
NOTE REG ARDING PRODUC T SUBS TITUTION
specification.
Care should be taken when substituting materials in
place of ClarkDietrich building materials. There is a DiamondPlus® High-Performance Coating—the next
misconception within the construction industry regarding generation of high-performance, code-compliant steel
the substitution of one manufacturer’s products or materials framing systems. ClarkDietrich offers ProSTUD® with
for those of another manufacturer. The assumption is that DiamondPlus coating. This corrosion-resistant coating
all studs of a given size and steel thickness are interchangeable. not only meets the performance level of standard G40
It may be possible that the substitution can safely be made, steel—it far surpasses it. In fact, in ASTM B117 Salt Spray
but the decision should not be made until the structural Testing, samples coated with DiamondPlus didn’t climb
properties of the products or materials involved are compared above 3% surface rust even after 240 hours of testing. G40
by a qualified engineer. with an additional passivation coating, variations all
commonly known as "chem treat", reached the 10% failure
Y IELD S TRENG TH (F Y/P SI OR KSI)
threshold at 192 hours on average. For the highest corrosion
ClarkDietrich products are manufactured with steel having
resistance, request ProSTUD with DiamondPlus coating.
a yield point of 33ksi for 18 and 20 gauge material. A yield
point of 50ksi is standard for 16 gauge and heavier material.
KSI = kips/square inch; kip = 1,000 lbs.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
8 OVERVIEW
H OW TO U S E T H I S C ATA LO G
ProSTUD 25 15 50 0.0158 0.0150 None Product, application renderings and photographs are
ProSTUD 20 18 70 0.0190 0.0181 Brown
ProSTUD 30 30 33 0.0312 0.0296 Pink
provided as a tool to show the general intent of the
ProSTUD 33MIL
ProTRAK 25 and 20 = 50ksi
33 33 0.0346
ProTRAK 30mil and 33mil = 33ksi
0.0329 White framing or finishing application only. These renderings
or photographs may or may not be applicable to a specific
project. They do not replace or supersede the architect
ClarkDietrich structural thickness identification by color coding
Member Thickness Design Min. Color or engineer of record, ASTM guidelines, national or local
mils gauge thickness thickness code
building codes or approved industry standards.
33 20 0.0346" 0.0329" White
43 18 0.0451" 0.0428" Yellow
54 16 0.0566" 0.0538" Green ClarkDietrich reserves the right to change or modify the
68 14 0.0713" 0.0677" Orange
97 12 0.1017" 0.0966" Red information contained in this catalog without prior notice
118 10 0.1242" 0.1180" Blue
or obligation. The information in this catalog supersedes all
previously published data. Products and systems may be
improved and/or changed after this catalog is printed.
PRODUC T L ABELING
Skids are easily identified with master skid labels that display
PRODUC T AVAIL ABILIT Y
product, mil thickness, size, length, piece count, yield
Most products manufactured by ClarkDietrich are readily
strength and any special skid markings specified at the
available in all markets, but there can be exceptions. Please
time of order. Individual inkjet labeling (including company
contact your ClarkDietrich Sales Representative to make
name, product, size, length, mil thickness, coating and
sure the product you need is available in your market area.
yield strength) or embossing is also provided on many of
our structural framing members. UPC bar coding is also
available for certain products.
NOTE: This catalog does not provide load data (load capacities, limiting heights, physical and structural properties and span data) necessary for
building design. Contact ClarkDietrich at 888-437-3244 for technical assistance.
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 9
Developed, tested, and approved by pros—in the field. SOUND PERFORM ANCE
The ProSTUD® Drywall Framing System with Smart ProSTUD also has exceptional sound performance in
Edge™ Technology can be called many things. Strong. over 50 tested sound assemblies—more testing than any
Versatile. Fast. And without a doubt—revolutionary. But other manufacturer in the industry.
it was also developed, tested and approved by pros in the
field who demanded nothing less than achieving absolute ProSTUD Drywall Studs and ProTRAK® Drywall Track
ease of use. Its performance has also been proven by the were created specifically to work as a system. This means
most extensive laboratory evaluations available. they work better together for you in achieving strength,
fire and sound ratings. It’s also an approach that leads to
THE INDUS TRY ’ S PRODUC T OF CHOICE enhanced performance on the job—during installation
Gauge equivalent (EQ) drywall framing must meet the and long after.
minimum performance requirements of conventional
• High-strength steel combined with low-profile flange stiffening
drywall framing as defined by the Steel Framing
grooves and double offset web planking increases strength and
Industry Association (SFIA) and the Steel Stud provides greater limiting heights
Manufacturers Association (SSMA). For interior • Diamond embossed web creates stiffness, reducing flange
drywall framing members, bending strength (or fade and screw spinout during drywall installation
allowable moment) is the criteria most important to • Strong, lightweight stud and track cuts and handles easier
the strength of a wall or ceiling. ProSTUD employs than conventional flat steel studs
• Flange grooves provide sight line for drywall alignment
modern roll-forming and steel-making technology
and aid in positioning screws at drywall joints to maintain the
that enhances the shape and strength with greater 3/8"edge requirement
efficiency. ProSTUD—the product of choice—exceeds • Web and leg enhancements in ProTRAK provide straight
the performance of conventional drywall framing for and rigid legs, making it the best choice for framing walls,
allowable moment and screw connection strength. headers, soffits, and bulkheads
• Smart Edge™ Technology is an enhancement for producing
LIFE S AFE T Y easier-to-handle steel that reduces the risk of cuts and
scrapes.
Life Safety is the primary concern and duty of all
• Nationwide availability
construction and design professionals. ProSTUD
features a number of technological advances to enhance
its stiffness and strength, contributing to its allowable
moment performance. When it comes to fire-rated
systems, ProSTUD is UL-approved for the most common
UL design assemblies including V450, U419, V438 and
chase wall assemblies.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
10 DRY WALL FRA MING
ProSTUD® Thickness
Web width Flange
Product code Product name Design ksi
Gauge Mils (in) (in)
thickness (in)
ProSTUD 25 25 15 0.0158 50
1-5/8, 2-1/2,
ProSTUD 20 20 18 0.0190 70
PDS 3-5/8, 1-1/4
ProSTUD 30MIL 20 DW 30 0.0312 33
4, 6
ProSTUD 33MIL 20 STR 33 0.0346 33
ProTRAK® Thickness
Web
Leg
Product code Product name Design ksi width
Gauge Mils (in)
thickness (in) (in)
3.103.08
Allowable Pullout (lbs)
3 45
40
30 31
20 Gauge (Drywall)
2 24
1.69
ProSTUD 20
ProSTUD 25
1.48
20 Gauge (Drywall)
15
25 Gauge
1
ProSTUD 20
ProSTUD 25
0
25 Gauge
0
#6 Screw Shear (Bearing) Values
iProSTUD.com 120
52
44
ProSTUD 20
ProSTUD 25
30
25 Gauge
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 11
INTERIOR 360TRAK™
360TR AK™
Thickness
Product Length Size
code Design (ft) (in)
Gauge (mils) Yield Strength
thickness (in)
2-1/2
20ga DW 3-5/8
360FT 0.0312 33ksi 10'
(30mils) 4
6
NOTE: G40 coating. Use only in nonload-bearing applications.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
12 DRY WALL FRA MING
The TRAKLOC product line provided by ClarkDietrich is licensed under the following U.S. and Foreign Patents:
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 13
TRAKLOC® STUDS
The Deflection (TLD) and Elevator (TLE) are two-piece components which
allow for the telescoping feature unique to TRAKLOC. The two-piece
components arrive pre-assembled to help speed assembly. The installer simply
inserts the top end of the stud in the top track and then extends the stud
(telescoping) to the proper length to engage the bottom end of the stud in the Y
bottom track. The unique swage at the end of each stud allows for quick, tight
installation eliminating the need for framing screws or a lift/ladder to install
the framing screws.
WEB DEPTH
Storage Requirements: TRAKLOC is a dynamic system consisting of
two moving parts. To maintain the telescoping feature of this system, it is X X
LIP
5/16"
Y
FLANGE
WIDTH
1-1/4"
TRAKLOC track has two unique features. The most obvious feature of
the TRAKLOC track is the V-groove rolled into the flanges of the track
to match the swaged ends of the TRAKLOC stud. Next, are the dimples
pressed into the center of the web. Together, the V-groove and the dimples
provide a positive connection between stud and track without the need for
mechanical fasteners.
INSIDE WEB
DEPTH
X
WIDTH
1-3/8"
LEG
Y Y
GROMMETS
Grommets snap easily into stud Product code Size (in) Description Pcs./Carton
knockouts and are used to protect
3/4 For 1-5/8" and 2-1/2" studs
electrical wiring and plumbing lines GROM
1-1/2 For 3-1/2" and wider studs
100
from contacting metal. Grommets
are commonly used in construction
when metal conduit is not required
2-Piece Grommet by building code.
Snap-In Bushing
CORNER ANGLE
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 15
Z- F U R R I N G
FURRING CHANNEL
B A R R I E R M E S H™ & B A R R I E R M E S H ™ C L I P
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
16 DRY WALL FRA MING
P O N Y WA L L H E AV Y (12G A )
PRODUCT DIMENSIONS
PW24 = 23-3/4" tall with 3-3/8" wide x 8" long plate
PW36 = 35-3/4" tall with 3-3/8" wide x 8" long plate
PW48 = 47-3/4" tall with 3-3/8" wide x 8" long plate
MATERIAL SPECIFICATIONS
ASTM A36 1/2" thick hot rolled steel
Plate Material:
PW48 = 47-3/4”
PW36 = 35-3/4”
PW24 = 23-3/4”
Stud Material:ASTM A1011 SS Grade 50, 50ksi (340 MPa)
12ga (97mil), 0.1017" Design thickness, 0.0966" Min. thickness
Packaging: Individually
ASTM: A36, A1011
3-
PW36 97mil (12ga) 0.1017 35-3/4" Individually
3/
PW48 47-3/4" Individually
8”
8”
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 17
Pony Wall Heavy (PW) Allowable Loads CONCENTRATED LOAD AT FREE END
MATERIAL SPECIFICATION
PONY WALL HEAVY STUD
Po
Material Thickness: 12ga (97mil), 0.1017" design thickness in
tL
Material Strength: Structural grade 50, 5
0ksi minimum yield strength oa
d
ASTM: A1011
Pony Wall Heavy (PW) Allowable Loads CONCENTRATED LOAD AT FREE END
Max point load @ cantilever end, lbs Moment (ASD) due to point load, in-lbs
Member Pony Wall
designation Length (in) L/720 L/360 L/240 L/180 Max L/720 L/360 L/240 L/180 Max
M
24 165 330 495 661 763 3,964 7,927 11,891 15,854 18,316
Pony Wall
36 73 147 220 294 509 2,642 5,285 7,927 10,569 18,316
Heavy
48 41 83 124 165 382 1,982 3,964 5,945 7,927 18,316
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Heavy member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between ClarkDietrich Pony Wall Heavy and support structure are designed by others.
6 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
7 Listed maximum point load at cantilever end calculated using maximum allowable moment. When both point load and uniform loads are applied,
combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.
Pony Wall Heavy (PW) Allowable Loads w/Anchors CONCENTRATED LOAD AT FREE END
Max point load @ cantilever end, lbs Allowable base moment, in-lbs
Pony Wall
Member Anchors No. of
length,
designation to structure Anchors L/720 L/360 L/240 L/180 Max L/720 L/360 L/240 L/180 Max
in
1 142 142 142 142 142 3,403 3,403 3,403 3,403 3,403
PW24 24
4 165 330 452 452 452 3,964 7,927 10,840 10,840 10,840
1/2" ɸ Hilti Kwik Bolt-3
(3-1/2" Nominal 1 73 95 95 95 95 2,642 3,403 3,403 3,403 3,403
PW36 36
Embedment, 3000psi 4 73 147 220 294 301 2,642 5,285 7,927 10,569 10,840 (1) Anchor to structure
Uncracked concrete)
1 41 71 71 71 71 1,982 3,403 3,403 3,403 3,403
PW48 48
4 41 83 124 165 226 1,982 3,964 5,945 7,927 10,840
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4. (4) Anchors to structure
6 Above listed capacities w/anchors shall be used only when using 1/2" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Heavy capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
18 DRY WALL FRA MING
P O N Y WA L L H E AV Y (12G A )
MATERIAL SPECIFICATION
PONY WALL HEAVY STUD
Material Thickness: 12ga (97mil), 0.1017" design thickness Po
Material Strength: Structural grade 50, 5
0ksi minimum yield strength in
tL
ASTM: A1011
oa
d
PONY WALL HEAVY BASE PLATE
Material Thickness: 1/2" minimum thickness
Material Strength: 36ksi minimum yield strength
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported
at the top track. (1) Anchor to structure
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Heavy member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
6 Above listed capacities w/anchors shall be used only when using 1/2" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Heavy capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation. (4) Anchors to structure
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 19
MATERIAL SPECIFICATION
PONY WALL HEAVY STUD
Material Thickness: 12ga (97mil), 0.1017" design thickness
Material Strength: Structural grade 50, 5
0ksi minimum yield strength
ASTM: A1011
24 220 440 661 763 763 5,285 10,569 15,854 18,316 18,316
Pony Wall
36 65 130 196 261 339 3,523 7,046 10,569 14,093 18,316
Heavy
48 28 55 83 110 191 2,642 5,285 7,927 10,569 18,316 M
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported
at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between ClarkDietrich Pony Wall Heavy and support structure are designed by others.
6 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
7 Listed maximum point load at cantilever end calculated using maximum allowable moment. When both point load and uniform
loads are applied, combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.
1 142 142 142 142 142 3,403 3,403 3,403 3,403 3,403
PW24 24
4 165 330 452 452 452 3,964 7,927 10,840 10,840 10,840
1/2" ɸ Hilti Kwik Bolt-3
(3-1/2" Nominal 1 73 95 95 95 95 2,642 3,403 3,403 3,403 3,403
PW36 36
Embedment, 3000psi 4 73 147 220 294 301 2,642 5,285 7,927 10,569 10,840
Uncracked concrete)
1 41 71 71 71 71 1,982 3,403 3,403 3,403 3,403
PW48 48
4 41 83 124 165 226 1,982 3,964 5,945 7,927 10,840
(1) Anchor to structure
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Heavy member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
6 Above listed capacities w/anchors shall be used only when using 1/2" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors. (4) Anchors to structure
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
20 D R Y W A L L F R A M I N G
LGPW-60 = 59-5/8”
LGPW-48 = 47-5/8”
LGPW-36 = 35-5/8”
LGPW-24 = 23-5/8”
MATERIAL SPECIFICATIONS
Plate Material:ASTM A36 thick hot rolled steel
Stud Material: ASTM A1011 SS Grade 50, 50ksi (340 MPa)
16ga (54mil), 0.0566" Design thickness, 0.0538" Min. thickness
Packaging: Individually
ASTM: A36, A1011
2-
Pony Wall Lite (LGPW)
3/
8”
Product Thickness
Size (in) Packaging
code Mils (Gauge) Design thickness (in)
2”
5 1/
LGPW24 23-5/8"
LGPW36 35-5/8"
54mil (16ga) 0.0566 Individually
LGPW48 47-5/8"
LGPW60 59-5/8"
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 21
Pony Wall Lite (LGPW) Allowable Loads CONCENTRATED LOAD AT FREE END
MATERIAL SPECIFICATION
PONY WALL LITE STUD
Material Thickness: 16ga (54mil), 0.0566" design thickness
Material Strength: Structural grade 50, 5
0ksi minimum yield strength
ASTM: A1011
Pony Wall Lite (LGPW) Allowable Loads CONCENTRATED LOAD AT FREE END
Max point load @ cantilever end, lbs Moment (ASD) due to point load, in-lbs
Member Pony Wall
designation Length (in) L/240 L/180 Max L/240 L/180 Max
Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between Pony Wall Lite and support structure are designed by others.
6 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
7 Listed maximum point load at cantilever end calculated using maximum allowable moment. When both point load and uniform loads are applied,
combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.
Pony Wall Lite (LGPW) Allowable Loads w/Anchors CONCENTRATED LOAD AT FREE END
Pony Wall Max point load
Member Anchors No. of Allowable base moment, in-lbs
length, @ cantilever end, lbs
designation to structure Anchors
in L/240 L/180 Max L/240 L/180 Max
LGPW24 24 83 83 83 1984 1984 1984
LGPW36 36 3/8" ɸ Hilti Kwik Bolt-3 38 51 55 1383 1844 1984
(2-3/8" Nominal Embedment, 2
LGPW48 48 3000psi Uncracked concrete) 22 29 41 1037 1383 1984
LGPW60 60 14 18 33 830 1106 1984
Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
6 Above listed capacities w/anchors shall be used only when using 3/8" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Lite capacity, but must be designed separately. (2) Anchors to structure
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
22 DRY WALL FRA MING
MATERIAL SPECIFICATION
PONY WALL LITE STUD
Material Thickness: 16ga (54mil), 0.0566" design thickness
Material Strength: Structural grade 50, 5
0ksi minimum yield strength
ASTM: A1011
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
D R Y W A L L F R A M I N G 23
MATERIAL SPECIFICATION
PONY WALL LITE STUD
Material Thickness: 16ga (54mil), 0.0566" design thickness
Material Strength: Structural grade 50, 5
0ksi minimum yield strength
ASTM: A1011
Member Pony Wall Uniformly distributed load, lbs/ft Moment (ASD) due to uniform load, in-lbs
designation Length (in) L/240 L/180 Max L/240 L/180 Max
24 115 154 177 2766 3688 4253
Pony Wall 36 34 46 79 1844 2458 4253
Lite 48 14 19 44 1383 1844 4253
60 7 10 28 1106 1475 4253
Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between Pony Wall Lite and support structure are designed by others.
6 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
7 Listed maximum uniformly distributed load calculated using maximum allowable moment. When both point load and uniform loads are
applied, combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.
Pony Wall
Member Anchors No. of Uniformly distributed loads, lbs/ft Allowable base moment, in-lbs
length,
designation to structure Anchors
in L/240 L/180 Max L/240 L/180 Max
LGPW24 24 83 83 83 1984 1984 1984
LGPW36 36 3/8" ɸ Hilti Kwik Bolt-3 34 37 37 1844 1984 1984
(2-3/8" Nominal Embedment, 2
LGPW48 48 3000psi Uncracked concrete) 14 19 21 1383 1844 1984
LGPW60 60 7 10 13 1106 1475 1984
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
24 S O U N D - R A T E D S Y S T E M S
P r o S T U D® 3 - 5 / 8 " S O U N D A S S E M B L I E S
STC Rating / Test Report
Partition type Assembly description ProSTUD 25 ProSTUD 20
ProSTUD 30mil ProSTUD 33mil
(15mil) (18mil)
3-5/8" ProSTUD
@ 24" o.c.
43 40 37 36
1 layer 5/8" Type X GWB on each side TL09-539 TL19-091 TL20-412 TL13-197
3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation @ 24" o.c.
48 47 40 37
1 layer 5/8" Type X GWB on each side TL09-540 TL19-094 TL20-413 TL13-196
3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation
@ 24" o.c.
49 51 40 42
1 layer 5/8" Type X GWB on one side TL13-167 TL19-092 TL13-202 TL13-195
2 layers 5/8" Type X GWB on the other side
3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation @ 24" o.c.
54 52 42 45
2 layers 5/8" Type X GWB on each side TL09-538 TL19-093 TL13-201 TL13-194
3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation
@ 24" o.c.
54 53 48 50
RC-Deluxe w/ 1 layer 5/8" Type X GWB on one side TL18-302 TL19-097 TL20-414 TL16-369
1 layer 5/8" Type X GWB on the other side
3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation
@ 24" o.c.
59 58 55 56
RC-Deluxe w/ 2 layers 5/8" Type X GWB on one side TL09-543 TL19-096 TL20-415 TL16-370
1 layer 5/8" Type X GWB on the other side
3-5/8" ProSTUD .
3-1/2" R-13 unfaced insulation
@ 24" o.c.
62 60 58 58
RC-Deluxe w/ 2 layers 5/8" Type X GWB on one side TL13-181 TL19-095 TL20-416 TL13-200
2 layers 5/8" Type X GWB on the other side
Notes:
– Sound assemblies are certified by Western Electro-Acoustic Laboratories.
– NVLAP accredited for ASTM E90 & E413, ISO Certified.
– See STC test reports at www.clarkdietrich.com/ProSTUD for detailed requirements of construction of wall assembly.
Contact ClarkDietrich Technical Services at 888-437-3244 for questions about ProSTUD sound assemblies.
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
S O U N D - R A T E D S Y S T E M S 25
Made of 22mil steel, RC Deluxe is one of the most Resilient channel should be installed perpendicular
effective, low-cost methods of improving sound to the framing members with the attachment flange
transmission loss through wood and steel frame of the RC Deluxe installed along the bottom edge.
partitions. It is the preferred resilient channel in Channel is prepunched for screw attachments
many applications because of its extra-wide 1-1/2" to wood or steel framing members. Nails are not
screw flange. recommended.
Thickness
Product Design Size Length
code Mils thickness (in) (ft)
(in)
RCSD 22 0.0232 1-1/2 12
Sound assemblies are certified by Western Electro-Acoustic Laboratories.
NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
**Visit iProSTUD.com for current STC ratings.
R C-1 P R O ™ R E S I L I E N T C H A N N E L
Made of 25 gauge steel, RC-1 Pro is used as a cross- Resilient channel should be installed perpendicular
furring member for resilient attachment of gypsum. to the framing members with the attachment flange
Knurled face makes wallboard application easier. of the RC-1 Pro installed along the bottom edge.
Channel is prepunched for screw attachments
to wood or steel framing members. Nails are not
recommended.
Thickness
Product Design Length
Size (in)
code Mils thickness (ft)
(in)
RCUR 18 0.0188 1-1/4 12
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
26 S O U N D - R A T E D S Y S T E M S
R C - 1 P r o P l u s™ H E A V Y - D U T Y R E S I L I E N T C H A N N E L
Made of 22mil steel, RC-1 ProPlus is used as a cross- gypsum board. Resilient channel should be installed
furring member for resilient attachment of gypsum. perpendicular to the framing members with the
Knurled face makes wallboard application easier. attachment flange of the RC-1 ProPlus installed
along the bottom edge. Channel is prepunched
RC-1 ProPlus single-leg resilient channel is typically for screw attachments to wood or steel framing
used for applications with multiple layers of members. Nails are not recommended.
Thickness
Product Length
Design Size (in)
code Mils (ft)
thickness (in)
R C -2 P r o ™ D O U B L E - L E G R E S I L I E N T C H A N N E L
Made of 25 gauge steel, RC-2 Pro double-leg Resilient channel should be installed
resilient channel is typically used for ceiling perpendicular to the framing members.
applications. It is used as a cross-furring member Channel is prepunched for screw attachments
for resilient attachment of gypsum. Knurled to wood or steel framing members.
face makes wallboard application easier.
Thickness
Product Size Length
code Design (in) (ft)
Mils
thickness (in)
R C -2 P r o P l u s™ H E A V Y - D U T Y D O U B L E - L E G R E S I L I E N T C H A N N E L
Made of 22mil steel to provide a stiffer resilient Resilient channel should be installed perpendicular
channel, RC-2 ProPlus heavy-duty double- to the framing members. Channel is prepunched for
leg resilient channel is typically used for ceiling screw attachments to wood or steel framing members.
applications with multiple layers of gypsum board.
It is used as a cross-furring member for resilient
attachment of gypsum. Knurled face makes wallboard
application easier.
Thickness
Product Size Length
code Design (in) (ft)
Mils
thickness (in)
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
SOUND-R ATED SYSTEMS 27
Note: These guidelines are for ClarkDietrich's single leg RC Deluxe® and Note 2: Two-legged resilient furring channels may be attached to the wall
RC-1 Pro, and double leg RC-2 Pro. Details of construction for a specific and ceiling framing members using both legs. Alternately attach the legs
assembly to achieve the required fire or sound or acoustic rating shall of the resilient furring channel to the framing members. This method of
be obtained from fire test reports, sound, or acoustic tests, engineering attachment may reduce the sound rating performance of the assembly.
evaluations, or listings from recognized sound or acoustic laboratories. Verify acceptability with the approving authority prior to installation.
Install resilient furring channels at right angles (perpendicular) to the For walls, install the first (lowest) row of resilient furring channel no more
framing members. The resilient furring channel shall be positioned with than 2 in. (51mm) off of the floor and the last (highest) row of resilient
the slotted hole(s) directly over the framing member. The resilient furring furring channel not more than 6 in. (152mm) from the ceiling. For ceilings,
channel shall be attached to the framing member using the screw hole the first row and last row of resilient furring channel shall be located not
provided in the mounting flange. If no screw hole is provided or located at more than 6 in. (152mm) from the adjacent wall. (Measurements are to
the framing member, attach through the mounting flange. the center of the face of the resilient furring channel.)
No more than two layers of up to 5/8 in. (16mm) gypsum panel products Attach resilient furring channel to framing members with screws only. For
should be installed to resilient furring channel. steel framing, Type-S x 3/8 in. (9.5mm) pan-head framing screws may be
used. For wood framing members, Type-W or Type-S screws (minimum
Resilient furring channels should not be spaced greater than 24 in. 1-1/4 in. (32mm) long) may be used. It is not recommended that nails
(610mm) on-center when installed on wall framing members. For ceiling be used. Install the screws in the holes provided in the mounting flange
framing members spaced 24 in. (610mm) on-center, install resilient (whenever possible).
furring channels at 16 in. on-center maximum. For ceiling framing
members spaced 16 in. (406mm) on-center, install resilient furring Splicing of resilient furring channel members shall be done by "nesting"
channels at 24 in. (610mm) on-center maximum. the ends of the resilient furring channel members directly over the
framing member and screwing through the mounting flanges into the
In the case of wall framing members, resilient furring channels should be framing member. (An acceptable alternative would be to butt the resilient
installed with the mounting flange of the resilient furring channel down, furring channel members over the framing member leaving a minimum
except at the floor or starter row where the mounting flange may be 1/16 in. (1.6mm) gap between resilient furring channels.)
installed with the flange up, to accommodate fastening to the framing
members. In the case of two-legged resilient furring channel, attach only Gypsum panel products shall be attached to the resilient furring channel
the lower mounting flange to the wall framing members, except as noted. using a screw length to ensure that the screw point does not make
contact with the framing member. (This will minimize the potential of the
Note 1: By keeping the mounting flange down, the weight of the gypsum screws hitting the wall studs and "short-circuiting" the sound resistance
panel products will pull the resilient channel away from the stud improving effectiveness of the resilient furring channels.)
the sound rating.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
28 S O U N D - R A T E D S Y S T E M S
UltraBEAD
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
H E A D - O F - W A L L S Y S T E M S 29
It’s a real challenge these days meeting head-of-wall codes for fire stop and life safety issues while maintaining the ability to
absorb vertical movement in low-, mid- and high-rise buildings. ClarkDietrich has the head-of-wall deflection products and
systems you need for interior wall assemblies subjected to movement—including seismic disturbances.
M a xT r a k ® S L O T T E D D E F L E C T I O N T R A C K
M a xT r a k 2 D S L O T T E D D E F L E C T I O N & D R I F T T R A C K
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
30 H E A D - O F - W A L L S Y S T E M S
D o u b l eTr a c k™ (O V E R T R A C K ) S Y S T E M
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
HE AD-OF-WALL SYSTEMS 31
F a s t T o p™ C L I P
YURCLIP
U l t r aT R A K S L OT T E D S Y S T E M
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
32 H E A D - O F - W A L L S Y S T E M S
UltraBEAD
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B L A Z E F R A M E T R A C K S 33
1.00" .22"
Fastener mid-height of
exposed slot
S L 1 (D E E P LEG—S LOT TE D O NE S ID E)
JR (J-RUNNER)
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
34 B L A Z E F R A M E T R A C K S
D L (D E E P LEG—SO LID)
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B L A Z E F R A M E T R A C K S 35
Profile with two solid legs with firestop Lower leg length
Profile Tape width (I) Joint protection
on both sides. Composite Firestop (L)
ODL 2 2.00" 1.00" 0.75"
Deflection Track System with "offset ODLW 2 2.00" 1.25" 1.00"
step" accommodates fireproofing up to
When used in conjunction with BlazeFrame Perimeter L-Bead, ODL 2 is UL
1-1/2" thick in head of wall and wall to 2079-fifth edition compliant. Provides joint protection for up to 1" with UL 2079
wall (column) assemblies. Class II or III Movement Capabilities.
Profile with two slotted lower legs Leg length Tape width Slot height
Profile Joint protection
with firestop on both sides. Composite (L) (I) (S)
ODSL 2 3.00" 1.00" 1.50" 0.75"
Firestop Deflection Track System ODSLW 2 3.00" 1.25" 1.50" 1.00"
with "offset step" accommodates
When used in conjunction with BlazeFrame Perimeter L-Bead, ODSL 2 is UL
fireproofing up to 1-1/2" thick in 2079-fifth edition compliant. Provides joint protection for up to 1" with UL 2079
head of wall and wall to wall (column) Class II or III Movement Capabilities.
assemblies. Two legs with slots spaced Widths: 3-5/8," 4," 6", and 8"
1" o.c. for positive attachment of studs. Thicknesses: 3 3mil (20ga), 43mil (18ga) and 54mil (16ga)
Vertical slots: 0.22" wide and spaced every 1" o.c.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
36 B L A Z E F R A M E T R A C K S
B l a z e Fr a m e ® R i pT R A K ™
B l a z e Fr a m e ® R i pT R A K ™ S H A F T WA L L
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
D O O R A N D W I N D O W F R A M I N G 37
RedHeader PRO™
RedHeader PRO JA MB
H E A V Y - D U T Y S T U D ( H D S ®) F R A M I N G S Y S T E M
HDS HEADER
HDS JAMB
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
D O O R A N D W I N D O W F R A M I N G 39
L- H E A D E R
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
40 BRIDGING, BRACING AND BACKING
U-CHANNEL
S w i f t C l i p™ L S - S e r i e s™ S U P P O R T C L I P
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
BRIDGING, BRACING AND BACKING 41
Fa s t B r i d g e™ C L I P
CC 33 3/4 " C H A N N E L C L I P
B R I D G I N G T E R M I N AT I O N C L I P
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
42 BRIDGING, BRACING AND BACKING
E a s y C l i p™ U - S e r i e s™ C L I P A N G L E
E a s y C l i p™ X - S e r i e s™ C L I P A N G L E
Danback® WO O D B ACKI N G PL AT E
Just snap, flex and screw. It’s that fast. Product Width Length Packaging
code (in) (in) Pcs./Skid
Danback® is a heavy-duty, D16F*
D24F*
flexible wood backing system D16C**
5-1/8 48 250
used to support cabinets, shelves, D24C**
handrails, wall-mounted sinks
• Reduces steel stud backing labor costs by up to 75%
and counters, and all other wall-
mounted fixtures. Danback provides • Available for 16" and 24" o.c. framing
superior connection shear and • Eliminates cutting, notching, ripping and routing
pullout strength to support and • Made with Dricon® fire-retardant treated wood
meet even some of the heaviest
loading conditions. The patented
• Complies with all national building codes
hinge design actually flexes around Dricon® is a registered trademark of Arch Wood Protection, Inc.
the stud and snaps into place for a Danback® is a registered trademark of Daniel W. Tollenaar.
perfect fit—every time. U.S. Patent No. 6,705,056 of Daniel W. Tollenaar.
*F = fire-treated plywood. D16 = 16" o.c. spacing. D24 = 24" o.c. spacing.
Trimmables available for off-module spacing in bulk quantity.
**FSC-certified lumber available upon request, which can contribute to LEED® points on
your project. Contact ClarkDietrich LEED professionals at 888-437-3244 for more
information. FSC chain-of-custody # BV-COC-008121.
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B R I D G I N G , B R A C I N G A N D B A C K I N G 43
FastB ack® B AC K I N G C L I P
B ACKI N G PL AT E
K at z™ B L O C K I N G
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
44 BRIDGING, BRACING AND BACKING
BL A ZEFRAME® SHIELD
NOTCHED TRACK
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B R I D G I N G , B R A C I N G A N D B A C K I N G 45
Spazzer® 5400
S p a z z e r B A R F LY C L I P
The Spazzer fly clip is a secure, Product code Size (in) Packaging Pcs./Carton
SFLY 1 x 1-1/4 x 1 100
fast and efficient way to finish a
wall section. This prepunched clip
eliminates the need for cutting and
bending when using the Spazzer
5400 spacer bar.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
46 BRIDGING, BRACING AND BACKING
S w i f t C l i p™ L - S e r i e s™ S U P P O R T C L I P
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B R I D G I N G , B R A C I N G A N D B A C K I N G 47
FL AT S T R A PPI N G
COMMERCIAL STRAPPING
BACKER BAR
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
48 S H A F T W A L L
Tested, approved assemblies with unprecedented flexibility. important wall assemblies in a building. Vertical chases
What makes the ClarkDietrich shaftwall construction and mechanical enclosures keep vital communication,
system unique is that it has been tested with almost every power, water, fresh air and exhaust systems intact when a
gypsum board and shaftliner manufacturer in the country. fire occurs.
Other systems are only tested with one type of gypsum
board and shaftliner. Unlike competing systems, the CONS TRUC TION ME THODS
ClarkDietrich C-T stud and J-tabbed track system provide Cavity shaftwalls are constructed utilizing one of two
maximum flexibility, allowing you to choose from a variety methods: masonry/CMU or cold-formed steel and
of board manufacturers. This unprecedented flexibility gypsum. Gypsum drywall shaftwall construction has
means quick availability of product at economical costs. become the preferred and most widely used shaftwall
assembly. These shaftwalls are lightweight, install faster,
Shaftwall System consists of 1" shaftliner panels and provide lower in-place costs. They also significantly
supported by 2-1/2," 4" or 6" C-T studs and faced on one reduce structural framing and foundation costs, and are
side with varying layers of fire code board. easy, quick and clean to install.
Stairwall Systems are designed to enclose stairwalls, Masonry shaftwalls in high-rise buildings historically
and are finished on both sides with varying layers of fire weigh between 20 and 45 lbs. per square foot,
code board. compared to gypsum assemblies that weigh between
10 and 13 lbs. per square foot. In addition to substantial
LIFE S AFE T Y & FIRE-RESIS TANT PROTEC TION weight reduction, gypsum shaftwall assemblies can be
Shaftwall systems are nonload-bearing, fire-rated wall installed from the exterior of the shaft at each floor,
assemblies that provide critical, life safety, fire-resistant eliminating the need for scaffolding.
protection for elevator shafts, stairwells, vertical chases
and mechanical enclosures. Shaftwalls in elevators and
stairwells provide the only means of evacuation from the
building in an emergency—making them one of the most
Stairwall
Shaftwall
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
S H A F T W A L L 49
C-T S H A F T WA L L / S TA I R W E L L S T U D
J -TA B B E D T R A C K /J - R U N N E R
punched with fold-up tabs every *2 designates 2-1/4" leg; 3 designates 3" leg
12," permitting faster, more efficient PEI Evaluation Report AER-12061
installation. NOTE: 18ga only available in select markets and for interior systems only.
B l a z e Fr a m e ® R i pT R A K ™ S H A F T WA L L
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
50 A R E A S E P A R A T I O N W A L L
Cl a r kDi e t r i c h A R E A S E PA R AT I O N WA L L S Y S T E M
Fire-resistance protects lives and property. installed between 2" H-studs spaced 24" o.c. At the top
Area separation walls are nonload-bearing, 2-hour and and bottom of the walls, C-runners (or H-tracks) are
3-hour rated vertical wall assemblies that provide fire- installed back-to-back between vertically stacked panels.
resistant protection between adjacent living units in Overall stacked area separation wall assemblies cannot
apartment buildings, condominiums and townhouses. They exceed 50 feet or the limits of the applicable UL Fire
are also referred to as party walls, firewalls, multi-family Assembly.
walls and H-stud assemblies.
A photo of an area separation wall system after a fire is
Assembled between two independent walls, area separation shown below. Although this was a tragic event, it clearly
walls form a commonly shared party wall that extends proves the effectiveness of the system. It performed
from the foundation through the roof line. The walls are as designed by maintaining the integrity of the firewall,
assembled with two 1"-thick gypsum panel liners vertically protecting the lives and property of the adjacent units.
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
ARE A SEPAR ATION WALL 51
H-S TUD
C- R U N N E R
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
52 C U R T A I N W A L L F R A M I N G
C-S T U D S
*20 and 18 gauge are standard as 33ksi yield strength. 16, 14 and 12 gauge are standard as 50ksi yield strength.
x = mil thickness identifier
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
C U R T A I N W A L L F R A M I N G 53
K N O C KO U T S /K N O C KO U T PAT T E R N
ClarkDietrich cold-formed C-studs for axial load- Knockouts are punched 12" o.c. from the lead edge
bearing and curtain wall framing are prepunched with with additional knockouts every 24" o.c. (on the
knockouts at regular intervals. These punchouts are West Coast, the first knockout is punched 24" o.c.
specifically designed to allow for rapid installation of from the lead edge). Caution must be exercised when
pipes, electrical conduit and wall bridging. installing studs so knockouts align for bridging. Based
on stud length, the distance the knockout falls from
Standard knockout sizing is 1-1/2" x 4" in members the tail end of the stud may not be the same from the
3-1/2" and wider. Members smaller than 3-1/2" are lead end. To align punchouts, make sure to use the
unpunched unless otherwise specified at time of same end in the same direction consistently.
order. If specified, members will be punched with a
3/4" x 4" knockout.
GROMMETS
Grommets snap easily into stud Product code Size (in) Description Pcs./Carton
knockouts and are used to protect
3/4 For 1-5/8" and 2-1/2" studs
electrical wiring and plumbing GROM
1-1/2 For 3-1/2" and wider studs
100
lines from contacting metal.
Grommets are commonly used
when metal conduit is not required
2-Piece Grommet by building code.
Snap-In Bushing
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
54 C U R T A I N W A L L F R A M I N G
CORNER ANGLE
H E AV Y- D U T Y F U R R I N G C H A N N E L
Z- G I R T F O R R A I N S C R E E N F R A M I N G
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
F L O O R F R A M I N G 55
FLOOR FRAMING
You can have confidence in the strength of steel For all of these reasons, steel floor framing has
under your feet. become the standard for low- and mid-rise commercial
Floor framing made from cold-formed steel is stronger and structures such as hotels, apartments, condominiums
more versatile. Its high strength-to-weight ratio provides and assisted living, as well as residential homes.
strong loading capacity and maximum spanning capability.
• Available in a variety of web sizes, flanges, thicknesses and
It can be used with all traditional flooring materials such as yield strengths
plywood, OSB, concrete-filled steel deck or one of the many • Pre-spaced joist tabs
varieties of fiber-reinforced cement board. It doesn’t squeak • Greater spanning capabilities
when you walk across it. • Prepunched openings
• Full system of joist components, accessories,
What’s more is that ClarkDietrich’s exclusive TradeReady® hangers and connectors
The revolutionary TradeReady Steel Joist System features a tabbed rim track to strengthen the joist against web crippling
loads, and to provide greater versatility and strength for ledger applications. In conjunction with other floor sheathing
products, this system provides one of the most cost-effective systems for non-combustible low- and mid-rise structures.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information Pub. No. CD-Framing 9/24
56 F L O O R F R A M I N G
Tr a d e Re a d y ® S T E E L J O I S T
8 Diam. 12 TDW
10 Diam. 14 TDW
Tr a d e R e a d y R I M
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
F L O O R F R A M I N G 57
Tr a d e R e a d y ® S T R U C T U R A L B R I D G I N G
Tr a d e R e a d y ® F L O O R J O I S T B L O C K I N G
E a s y C l i p™ Q u i c kTw i s t ™ W E B S T I F F E N E R
Thickness
EasyClip™ QuickTwist™ web Product
Size (in)
Height*
Packaging
code Design (in)
stiffeners are used to provide Gauge Mils
thickness (in)
reinforcement of joist webs 7-1/4
to prevent crippling. Web 8
9-1/4
reinforcement is often required QTWS 3-1/2 12 97 0.1017 10
Dependent on
by design to enhance the load order quantity
11-1/4
capacity of joists. The unique 12
design of QuickTwist allows the 14
7-1/4
installer to insert the stiffener 8
on the inside of the joist after the 9-1/4
Dependent on
joist is installed. This stiffener QTWS 6 12 97 0.1017 10
order quantity
11-1/4
eliminates the need to pre-insert
12
traditional web stiffeners prior to 14
joist installation. The one-piece
assembly is easily rotated in NOTE: Dimension is nominal size. Actual product is shorter to fit inside joist.
place for a tight fit.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information Pub. No. CD-Framing 9/24
58 F L O O R F R A M I N G
L I G H T- G AU G E C-J O I S T F R A M I N G
COMMERCIAL STRAPPING
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
F L O O R F R A M I N G 59
E a s y C l i p™ E - S e r i e s™ S U P P O R T C L I P
E a s y C l i p S - S e r i e s™ S U P P O R T C L I P
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information Pub. No. CD-Framing 9/24
60 F L O O R F R A M I N G
BRIDLE HANGER
S KE WA B LE A NG LE
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
INDEX 61
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
62 I N D E X
PATENTS/TRADEMARKS/WARRANT Y
Patents Trademarks
U.S. Patent Nos. 5
,689,922; 5,816,002; ClarkDietrich is a registered trademark of ClarkDietrich Building Systems. ProSTUD®, ProTRAK®, TRAKLOC®,
6,070,374; 6,301,854; TradeReady®, Spazzer ®, FastClip™, EasyClip™, Fast Top™, Fast Strut™, FastBridge™, Uni-Clip™, Clip ExpressSM ,
6,418,694; 6,688,069; Stronger Than SteelSM , FastBack™, HDS®, RedHeader PRO™, QuickTwist™, Slide Clip™, SubmittalPro®,
6,691,478; 6,691,487; SwiftClip™, A-Series™, B-Series™, D-Series™, E-Series™, G-Series™, GP-Series™, H-Series™, L-Series™,
6,708,460; 6,761,005; LS-Series™, LE-Series™, LA-Series™, S-Series™, T-Series™, U-Series™, X-Series™, MaxTrak®, Bar Guard™,
7,240,459 DoubleTrack™ QC-Series™, Katz™, BackerBead®, E-Flange™, DiamondPlus®, ClarkDietrich Sound Clip™, RC
Canadian Patent No. 2319346 Deluxe® Resilient Channel and 360TRAK™ are owned by ClarkDietrich.
Barrier Mesh,™.
Mexican Patent No. 243294
U.S. Patent No. 6,705,056 is owned by Daniel DriCon® is a registered trademark of Arch Wood Protection, Inc.
W. Tollenaar LEED® is a registered trademark of the U.S. Green Building Council.
Danback® is a registered trademark of Daniel W. Tollenaar.
U.S. Patent No. 7,882,676 is owned by Jeffery
UL® and UL Design® are trademarks of Underwriters Laboratories, Inc.
Thomas Ellis
Warranty
Our products are manufactured in accordance with company standards and/or industry standards, as applicable. All ClarkDietrich products are covered by our standard
warranty which is contained in our Standard Terms and Conditions of Sale and which will be provided upon request. Generally, we warrant our products will be free from
defects in material and workmanship at the time of shipment, subject to the limitations stated in the warranty. Unless specifically agreed in writing by us with respect to
specific orders, we do not make any warranty of merchantability or fitness for a particular purpose. The buyer is responsible to assure that buyer orders the appropriate
product for any applicable code or specification requirements.
NOTICE: Our liability is expressly limited to replacement of defective products. We shall not be liable for incidental and consequential damages, nor for any loss caused
by misuse or misapplication of our products. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from the date it was or reasonably
should have been discovered.
Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
63
C O D E A P P R O VA L S A N D P E R F O R M A N C E S TA N D A R D S
ClarkDietrich products meet or exceed these applicable performance standards.
ClarkDietrich is a proud member of the Steel Framing Industry Association (SFIA). Check the
updated list of Certified Production Facilities at Intertek's website at www.intertek.com.
LOCATIONS
MISSOURI O'Fallon OHIO Warren—East OHIO Vienna OKLAHOMA Oklahoma City CENTRAL Merrillville, IN SOUTHEAST McDonough, GA
P 636.300.1411 P 330.372.5564 P 330.372.4014 P 405.896.2563
NORTHEAST Bristol, CT WEST Carlsbad, CA
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
Online Revision: pgs. 16-23 Pony Wall product images
6/23/2022 - pg. 60 - Universal Joist Hanger product image
6/23/2022 - pg. 19 - Pony Wall Chart update
7/27/2022 - pg. 15 - Z-Furring Chart update
12/9/2022 - pg. 43 - Updated FastBack™ chart and image
6/27/2023 - pg. 48 - Updated Shaftwall chart
9/5/2023 - pg. 51 - AB clip material note
9/15/2023 - pg. 63 - Structural Code Approvals
10/01/2023 - pg. 63 - Structural Code Approvals
11/3/2023 - pgs. 37-38 - HDS® and RedHeader PRO™ image and chart changes
9/30/2024 - pg. 63 - Structural Code Approvals
Turn to ClarkDietrich for a complete lineup of steel construction products and services nationwide:
Interior Framing ∙ Exterior Framing ∙ Interior Finishing ∙ Exterior Finishing∙ Clips/Connectors ∙ Engineering
CD-Framing 9/24 © ClarkDietrich Building Systems. The technical content of this literature is effective 09/30/24 and supersedes all previous information.