FRAMING product catalog

STRONGER
T H A N S T E E L. SM

INTERIOR FRAMING • EXTERIOR FRAMING • FLOOR FRAMING


THE INDUSTRY’S MOST
COMPLETE
P R O D U C T L I N E U P.
A I M E D AT C H A N G I N G T HE
B U I L D I N G L A N D S C A PE .
Comprehensive is the word. On the We can reinforce your efforts to design and build
following pages, you’ll find framing for drywall, more intelligently with a versatile engineering
curtain wall, doors, windows and floors. services team and smarter installation and
Connectors, bridging, bracing and backing. The design techniques. Furthermore, we offer the
list of our products goes on, but there’s much efficiencies of a single supplier with unmatched
more to it than that. reach through 13 plants and 4 engineering
offices—as well as nationwide product availability.
We refer to ourselves as ClarkDietrich for a
reason. The future of building will be shaped by Regardless of your project’s size or complexity,
the inter-relationships of various products and the ClarkDietrich has the resources to help you
thinking behind them. Because of this, we create achieve your vision. And this comprehensive
cold-formed steel building products that compose catalog is a great start. Here you’ll find select
systems—systems backed by intelligent design details about products in our portfolio, including
tools and fully capable engineering services. key advantages and technical information, to
guide your specifications.
This systems approach means our products work
better together in achieving strength, fire and At the end of the day, a product line is only as
sound ratings. It’s also an approach that leads strong as the company that stands behind it.
to enhanced performance on the job—during You can count on the expertise, service and full
installation and long after. support of ClarkDietrich now, and far into the
future.

Need help with product selection, ordering, scheduling, delivery, or anything else?
Call us at 800-543-7140, or on the West Coast at 800-365-5284.

Need Product Submittals? Use SubmittalPro® at clarkdietrich.com.


4

Overview 5-8
Engineering Services 5
Clip Express℠ 5
Contact Information & Locations 6
How To Use This Catalog 7-8
Drywall Framing 9-23
Sound Rated Systems 24-28
Head-of-Wall Systems 29-32
BlazeFrame Tracks 33-36
TABLE OF CONTENTS
Door and Window Framing 37-39
Bridging, Bracing and Backing 40-47
Shaftwall 48-49
Area Separation Wall 50-51
Curtain Wall Framing 52-54
Floor Framing 55-60
Index 61-62
Patents/Trademarks/Warranty 62
Code Approvals 63

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
OVERVIEW 5

SUPPORT AND SERVICES

CLARKDIETRICH ENGINEERING SERVICES CLIP EXPRESSSM

Smarter engineering and technical expertise. Connections you can count on.
It’s support that extends beyond the structure itself.
We know that having the right products, at the right
From the initial design phase to jobsite installation, we time, and at the right price, is absolutely essential to
are all about providing inventive, yet practical and hands- getting the job done. ClarkDietrich Clip Express is your
on know-how to help you think outside the box—or to single source for the widest and most cost-effective
help you just get it done. array of rigid, deflection, bridging and general-purpose
clips, connectors, supports and framing hardware for
ClarkDietrich Engineering Services is a full-service commercial and residential cold-formed steel framing.
consulting firm that believes strongly in value
engineering and customer input. Our engineering fees With Clip Express, you get fully engineered, rigorously
and lead times are competitive, and our customer service tested and precision-formed connectors each and
exceeds the industry standard with consistent point-of- every time. Many of our connectors were developed
contact through our regional project managers. by, or in conjunction with, framing installers in order
to deliver high-performance products for significant
We offer Building Information Modeling (BIM) services installed savings.
that include specialty engineering collaborative design.
We support the BIM movement by offering add-on While you may find a cheaper price than ClarkDietrich,
tools that allow our products, and the rich data attached you won’t find a lower overall cost or better value. We
to them, to quickly be imported into digital designs. offer unmatched reach through numerous plants and
Our team is also comprised of LEED®-accredited engineering offices—and nationwide product availability.
professionals to consult on sustainable building design.
And because staying on schedule is crucial, we ship
• Electronically sealed shop drawings and calculations
most orders the same day they are received. We’ll get it
• Preliminary sizing and pre-bid engineering pricing
• Reference plan on large projects there when, how and where you need it. Our nationwide
• Detailed wall sections, full elevation opening manufacturing and service facilities see to that.
design and C-stud truss design
• Industry’s widest product selection available from one source
Our technical services team provides immediate • Fast delivery options meet your deadlines
response to questions ranging from general installation • Backed by the largest cold-formed steel framing
and engineering company in the world
to detailed specification requirements, and can deliver • Expert field representatives for comprehensive
one-day turnaround on technical sizing. We are experts product, installation and sales training
on industry standards such as AISI and ASTM, and a
proud member of SFIA. Our team also supports our
online product submittal system, SubmittalPro,® and
our design/engineering software is available as a free Throughout this catalog, when you see this icon next
download from www.clarkdietrich.com. to a product entry, you know the product is part of our
• Product support and typical member sizing Clip Express program.
• Framing detail recommendations
• Compliance and industry standards, such as AISI, ASTM and SFIA
• Engineering software and product submittal support
• LEED requirements support

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
6 OVERVIEW

C O N TAC T I N F O R M AT I O N

Our nationwide presence means we’re there for you.


On any project.

With 13 manufacturing plants and 4 engineering offices


strategically located throughout the U.S., ClarkDietrich
is always nearby. You can be assured that your product
will be delivered on time, and that you can call on us for
support any and every step of the way.

ClarkDietrich Manufacturing
and Sales Locations:
CALIFORNIA Riverside MARYLAND Baltimore
P 951.360.3500 P 410.477.4000

CALIFORNIA Sacramento MISSOURI O'Fallon


P 951.360.3500 P 636.300.1411

• CONNECTICUT Bristol OHIO Vienna


• •• •• P 866.921.0023 P 330.372.4014
★ •
• FLORIDA Dade City OHIO Warren-East
P 352.518.4400 P 330.372.5564
••
FLORIDA Miami TEXAS Dallas
• P 305.477.6464 P 214.350.1716

GEORGIA McDonough TEXAS Pasadena
• P 678.304.5500 P 281.383.1617

• ILLINOIS Rochelle
P 800.659.0745

Carlsbad, CA Merrillville, IN ClarkDietrich Engineering Services


Riverside, CA Baltimore, MD Toll-Free Phone: 877.832.3206
Sacramento, CA O'Fallon, MO Toll-Free Fax: 877.832.3208
Email: [email protected]
Bristol, CT Vienna, OH Technical Services: 888.437.3244
Dade City, FL Warren, OH
CENTRAL Merrillville, IN SOUTHEAST McDonough, GA
Miami, FL Dallas, TX
NORTHEAST Bristol, CT WEST Carlsbad, CA
McDonough, GA Pasadena, TX
Rochelle, IL West Chester, OH

• Manufacturing, engineering and technical services


★ Corporate office

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
OVERVIEW 7

H OW TO U S E T H I S C ATA LO G

This catalog is designed to help you select the right PROTEC TIVE COATINGS
products or systems for your construction applications. ClarkDietrich offers a wide variety of protective coatings
For your convenience, a comprehensive index containing to meet the specific requirements of a project.
our product and system offering is also located at the back
of the catalog. Search by common names and product Non-structural products are coated to meet the
names to help you quickly find exactly what you’re requirements of AISI S220/ASTM C645, with G40 or a
looking for. protective coating with an equivalent corrosion resistance.
Equivalent coatings meet the metallic equivalency
Structural properties and load tables are available on requirement of C645 by outperforming G40 in an
our website at clarkdietrich.com. ASTM B117 salt spray test. Non-structural products
may also be ordered with enhanced coatings, such as
HOW TO IDENTIF Y OUR PRODUC T S CP60 for use in special applications. The buyer is solely
ClarkDietrich has adopted standard nomenclature responsible to assure that product is ordered to properly
established by the American Iron and Steel Institute satisfy the applicable code or specification.
(AISI) for identifying each of its products. Coding
of each member consists of four parts, in this order: Structural framing products are available with a variety
of protective coatings that meet the CP60 coating
• A number which identifies the web depth of the
member to two decimal places: 600 = 6.00," 1000 protection level requirements of AISI S200, S240 and
= 10.00," 550 = 5.50," 362 = 3.625," etc. ASTM C955. These coatings may include G60, A60,
• A letter that identifies the type of member, such as S = Stud/ AZ50 or GF30, all of which satisfy the above referenced
Joist, T = Track, U = U-channel, and F = Furring channel.
standards. CP90 coatings are an enhanced option that
• A number that defines the flange dimension in inches to two
decimal places: 162 = 1.625," 200 = 2.00," 125 = 1.25," etc.
can be requested for highly corrosive environments.
• A number following a hyphen that denotes the minimum delivered ClarkDietrich can supply a specific or enhanced coating
thickness in mils (33mils = 33/1000 inches which is approximately to meet specific project requirements when requested.
0.0329"). Minimum delivered thickness is 95% of design thickness. The buyer is solely responsible to assure that product
is ordered to properly satisfy the applicable code or
NOTE REG ARDING PRODUC T SUBS TITUTION
specification.
Care should be taken when substituting materials in
place of ClarkDietrich building materials. There is a DiamondPlus® High-Performance Coating—the next
misconception within the construction industry regarding generation of high-performance, code-compliant steel
the substitution of one manufacturer’s products or materials framing systems. ClarkDietrich offers ProSTUD® with
for those of another manufacturer. The assumption is that DiamondPlus coating. This corrosion-resistant coating
all studs of a given size and steel thickness are interchangeable. not only meets the performance level of standard G40
It may be possible that the substitution can safely be made, steel—it far surpasses it. In fact, in ASTM B117 Salt Spray
but the decision should not be made until the structural Testing, samples coated with DiamondPlus didn’t climb
properties of the products or materials involved are compared above 3% surface rust even after 240 hours of testing. G40
by a qualified engineer. with an additional passivation coating, variations all
commonly known as "chem treat", reached the 10% failure
Y IELD S TRENG TH (F Y/P SI OR KSI)
threshold at 192 hours on average. For the highest corrosion
ClarkDietrich products are manufactured with steel having
resistance, request ProSTUD with DiamondPlus coating.
a yield point of 33ksi for 18 and 20 gauge material. A yield
point of 50ksi is standard for 16 gauge and heavier material.
KSI = kips/square inch; kip = 1,000 lbs.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
8 OVERVIEW

H OW TO U S E T H I S C ATA LO G

S TEEL THICKNESS S TANDARDS & SPECIFIC ATIONS


The steel thickness of a product or component is All structural properties are developed in accordance with
referenced in terms of decimal or mils. The mil thickness the American Iron and Steel Institute's "Specification for
measures the uncoated base steel material, and is a key the Design of Cold-Formed Steel Structural Members."
contributor to the strength of the product.
G ENER AL NOTES
Note: All products comply with ASTM and AISI standards and federal The data contained in this catalog is intended to be used as
specifications as shown in the Code Approvals and Performance
Standards in the back of this catalog. Minimum thickness is 95% of
a general guideline only and does not replace the judgments
the design thickness, per AISI code. One mil is equivalent to 1/1000 and designs of a qualified architect and/or engineer. This
(0.001) of an inch. So, a 20 gauge stud measuring the minimum catalog does not provide load data necessary for building
uncoated base steel at 0.0296 inches is 30mils thick.
design. Load capacities, limiting heights, physical and
structural properties and span data for ClarkDietrich
ClarkDietrich ProSTUD® Drywall framing system thickness structural framing can be found at www.clarkdietrich.com.
Member Design Min. Color
gauge Mils ksi thickness thickness code

ProSTUD 25 15 50 0.0158 0.0150 None Product, application renderings and photographs are
ProSTUD 20 18 70 0.0190 0.0181 Brown
ProSTUD 30 30 33 0.0312 0.0296 Pink
provided as a tool to show the general intent of the
ProSTUD 33MIL
ProTRAK 25 and 20 = 50ksi
33 33 0.0346
ProTRAK 30mil and 33mil = 33ksi
0.0329 White framing or finishing application only. These renderings
or photographs may or may not be applicable to a specific
project. They do not replace or supersede the architect
ClarkDietrich structural thickness identification by color coding
Member Thickness Design Min. Color or engineer of record, ASTM guidelines, national or local
mils gauge thickness thickness code
building codes or approved industry standards.
33 20 0.0346" 0.0329" White
43 18 0.0451" 0.0428" Yellow
54 16 0.0566" 0.0538" Green ClarkDietrich reserves the right to change or modify the
68 14 0.0713" 0.0677" Orange
97 12 0.1017" 0.0966" Red information contained in this catalog without prior notice
118 10 0.1242" 0.1180" Blue
or obligation. The information in this catalog supersedes all
previously published data. Products and systems may be
improved and/or changed after this catalog is printed.
PRODUC T L ABELING
Skids are easily identified with master skid labels that display
PRODUC T AVAIL ABILIT Y
product, mil thickness, size, length, piece count, yield
Most products manufactured by ClarkDietrich are readily
strength and any special skid markings specified at the
available in all markets, but there can be exceptions. Please
time of order. Individual inkjet labeling (including company
contact your ClarkDietrich Sales Representative to make
name, product, size, length, mil thickness, coating and
sure the product you need is available in your market area.
yield strength) or embossing is also provided on many of
our structural framing members. UPC bar coding is also
available for certain products.

ClarkDietrich is a proud member of the Steel Framing


Industry Association (SFIA).

NOTE: This catalog does not provide load data (load capacities, limiting heights, physical and structural properties and span data) necessary for
building design. Contact ClarkDietrich at 888-437-3244 for technical assistance.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 9

ProSTUD® DRY WALL FRAMING SYSTEM

Developed, tested, and approved by pros—in the field. SOUND PERFORM ANCE
The ProSTUD® Drywall Framing System with Smart ProSTUD also has exceptional sound performance in
Edge™ Technology can be called many things. Strong. over 50 tested sound assemblies—more testing than any
Versatile. Fast. And without a doubt—revolutionary. But other manufacturer in the industry.
it was also developed, tested and approved by pros in the
field who demanded nothing less than achieving absolute ProSTUD Drywall Studs and ProTRAK® Drywall Track
ease of use. Its performance has also been proven by the were created specifically to work as a system. This means
most extensive laboratory evaluations available. they work better together for you in achieving strength,
fire and sound ratings. It’s also an approach that leads to
THE INDUS TRY ’ S PRODUC T OF CHOICE enhanced performance on the job—during installation
Gauge equivalent (EQ) drywall framing must meet the and long after.
minimum performance requirements of conventional
• High-strength steel combined with low-profile flange stiffening
drywall framing as defined by the Steel Framing
grooves and double offset web planking increases strength and
Industry Association (SFIA) and the Steel Stud provides greater limiting heights
Manufacturers Association (SSMA). For interior • Diamond embossed web creates stiffness, reducing flange
drywall framing members, bending strength (or fade and screw spinout during drywall installation
allowable moment) is the criteria most important to • Strong, lightweight stud and track cuts and handles easier
the strength of a wall or ceiling. ProSTUD employs than conventional flat steel studs
• Flange grooves provide sight line for drywall alignment
modern roll-forming and steel-making technology
and aid in positioning screws at drywall joints to maintain the
that enhances the shape and strength with greater 3/8"edge requirement
efficiency. ProSTUD—the product of choice—exceeds • Web and leg enhancements in ProTRAK provide straight
the performance of conventional drywall framing for and rigid legs, making it the best choice for framing walls,
allowable moment and screw connection strength. headers, soffits, and bulkheads
• Smart Edge™ Technology is an enhancement for producing
LIFE S AFE T Y easier-to-handle steel that reduces the risk of cuts and
scrapes.
Life Safety is the primary concern and duty of all
• Nationwide availability
construction and design professionals. ProSTUD
features a number of technological advances to enhance
its stiffness and strength, contributing to its allowable
moment performance. When it comes to fire-rated
systems, ProSTUD is UL-approved for the most common
UL design assemblies including V450, U419, V438 and
chase wall assemblies.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
10 DRY WALL FRA MING

ProSTUD® DRY WALL FRAMING SYSTEM

ProSTUD® Thickness
Web width Flange
Product code Product name Design ksi
Gauge Mils (in) (in)
thickness (in)
ProSTUD 25 25 15 0.0158 50
1-5/8, 2-1/2,
ProSTUD 20 20 18 0.0190 70
PDS 3-5/8, 1-1/4
ProSTUD 30MIL 20 DW 30 0.0312 33
4, 6
ProSTUD 33MIL 20 STR 33 0.0346 33

Coatings: G40 EQ, G40 (CP60 available as special order)


G40 EQ DiamondPlus® available for 15mil and 18mil only.
See other ProSTUD product options at clarkdietrich.com.

ProTRAK® Thickness
Web
Leg
Product code Product name Design ksi width
Gauge Mils (in)
thickness (in) (in)

ProTRAK 25 25 15 0.0158 50 1-1/4,


1-5/8,
ProTRAK 20 20 18 0.0190 50 1-1/2,
2-1/2,
PDT 2,
ProTRAK 30MIL 20 DW 30 0.0312 33 3-5/8,
2-1/2,
4, 6
ProTRAK 33MIL 20 STR 33 0.0346 33 3

Coatings: G40 EQ, G40 (CP60 available as special order)


G40 EQ DiamondPlus® available for 15mil and 18mil only.
See other ProSTUD product options at clarkdietrich.com.

Allowable Bending Capacity, 3-5/8" Stud #6 Screw Pullout Values


4
60
52
Allowable Moment (Ma, in-k)

3.103.08
Allowable Pullout (lbs)

3 45
40

30 31
20 Gauge (Drywall)

2 24
1.69
ProSTUD 20
ProSTUD 25

1.48
20 Gauge (Drywall)

15
25 Gauge

1
ProSTUD 20
ProSTUD 25

0
25 Gauge

0
#6 Screw Shear (Bearing) Values
iProSTUD.com 120

Going mobile? With your smartphone 95 95


in hand, you can perform a fast, easy 90
Allowable Shear (lbs)

search, view ProSTUD limiting heights


and even email submittal documents. 60
20 Gauge (Drywall)

52
44
ProSTUD 20
ProSTUD 25

30
25 Gauge

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 11

INTERIOR 360TRAK™

A high-performance solution for intricate, HING ED TR ACK BR ACKE T S


dramatic architecture. The 360TRAK provides hinged track brackets
with pivot points every 3", allowing for smooth,
ClarkDietrich 360TRAK™ flexible framing products curved framing assemblies with tight and varying
are low-cost, high-performance framing solutions radii. Pre-drilled holes are located on each side
for non load-bearing curves, bends, variable radii and of the track brackets for securing the stud to the
arches for dramatic and distinctive ceilings, walls and bracket.
bulkheads.
ADJ US TABLE LEG S TR AP S
Today’s customers want elaborate and complex 360TRAK flexible framing products feature
architecture including sweeping bulkheads, curved adjustable leg straps that slide through the
walls, wavy ceilings, and elliptical curves. pivoting track brackets allowing the track
to contour to your desired curve, bend or
• Easily hand bends or forms to the desired
curve or bend with varying radii radius. The adjustable leg straps create curvable
• One product for both curves and arches flexability, while maintaining or holding its shape
• Use with wood or steel studs during installation.

360TR AK™
Thickness
Product Length Size
code Design (ft) (in)
Gauge (mils) Yield Strength
thickness (in)
2-1/2
20ga DW 3-5/8
360FT 0.0312 33ksi 10'
(30mils) 4
6
NOTE: G40 coating. Use only in nonload-bearing applications.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
12 DRY WALL FRA MING

TRAKLOC® DRY WALL FRAMING SYSTEM

TRAKLOC® Steel Framing is a revolutionary development FEATURES AND BENEFITS


in cold-formed steel framing systems. Unlike traditional
• Available in 24mil (20EQ) 57ksi, 30mil (20gaDW) 33ksi
steel studs, which are cut to length for varying jobsite
conditions, TRAKLOC allows you to order one length and 33mil (20ga) 33ksi.
member and "adjust" the length accordingly for variances • Available in 2-1/2", 3-5/8", 4" and 6".
in the slab. The stud consists of a traditional-style framing • For use in non-load-bearing interior walls.
• Twists and locks into place. Studs can be installed from
member combined with an interlocking adjustable
the ground, greatly reducing time spent climbing ladders
component. The adjustable portion allows for telescopic
and scaffolding.
length adjustments and can accommodate variances in the
slab, and minor wall height differences. • Installation of TRAKLOC is ICC-ES approved without the
use of fasteners to attach the studs to the top or bottom
TRAKLOC’s ICC-ES Report # ESR-1464 track. ICC-ES Report # ESR-1464.
is in compliance with: • Significant productivity gains are possible versus
• 2015 and 2012 International Building Code® (IBC) conventional stud and track framing. This results in
• 2016 California Building Code (CBC) substantial installed cost savings!
• 2017 Florida Building Code (FBC) • Safer Framing System™ reduces jobsite hazards. Less
time spent climbing scaffolds, ladders, lifts and bending
over to install screws results in fewer job related injuries
TRAKLOC non-load bearing interior wall system is and reduced workers' compensation costs. Less cutting of
Intertek Warnock Hersey Design Listed and approved studs with noisy chop saws.
for use in both one and two-hour fire-rated head-of-wall • Allows for seismic and live-load vertical inter-floor
assemblies requiring deflection in accordance with ASTM deflection in the stud, not the track. This feature
E119 and ASTM E1966. eliminates the need for deflection tracks in fire-rated
head-of-wall assemblies.

The TRAKLOC product line provided by ClarkDietrich is licensed under the following U.S. and Foreign Patents:

U.S. Patent No. 7,223,043


U.S. Patent No. 7,594,311
U.S. Patent No. 8,061,099
U.S. Patent No. 8,074,416
Japan Patent No. 4934868
Japan Patent No. 5156889
Australia Patent No. 2006201344
Australia Patent No. 2005332657

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 13

TRAKLOC® STUDS

TRAKLOC studs are available in two configurations:


• TRAKLOC Deflection Stud (TLD)
• TRAKLOC Elevator Stud (TLE)

The Deflection (TLD) and Elevator (TLE) are two-piece components which
allow for the telescoping feature unique to TRAKLOC. The two-piece
components arrive pre-assembled to help speed assembly. The installer simply
inserts the top end of the stud in the top track and then extends the stud
(telescoping) to the proper length to engage the bottom end of the stud in the Y

bottom track. The unique swage at the end of each stud allows for quick, tight
installation eliminating the need for framing screws or a lift/ladder to install
the framing screws.

WEB DEPTH
Storage Requirements: TRAKLOC is a dynamic system consisting of
two moving parts. To maintain the telescoping feature of this system, it is X X

important to store TRAKLOC studs indoors, free of excessive dust and


airborne particulates.

LIP
5/16"
Y
FLANGE
WIDTH
1-1/4"

TRAKLOC Drywall Stud


TR AKLOC® TR ACK

TRAKLOC track has two unique features. The most obvious feature of
the TRAKLOC track is the V-groove rolled into the flanges of the track
to match the swaged ends of the TRAKLOC stud. Next, are the dimples
pressed into the center of the web. Together, the V-groove and the dimples
provide a positive connection between stud and track without the need for
mechanical fasteners.

TRAKLOC track standard length is 10'-0".

INSIDE WEB
DEPTH
X
WIDTH
1-3/8"
LEG

Y Y

TRAKLOC Drywall Track


clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
14 DRY WALL FRA MING

GROMMETS

Grommets snap easily into stud Product code Size (in) Description Pcs./Carton
knockouts and are used to protect
3/4 For 1-5/8" and 2-1/2" studs
electrical wiring and plumbing lines GROM
1-1/2 For 3-1/2" and wider studs
100
from contacting metal. Grommets
are commonly used in construction
when metal conduit is not required
2-Piece Grommet by building code.

Snap-In Bushing

CORNER ANGLE

Corner angle is a multipurpose 90˚ Thickness


or 120˚/135˚ galvanized angle used Length
Product code Design Size (in)
Gauge Mils (ft)
in dozens of framing applications. thickness (in)
Some of the most common 5/8 x 2
applications include lapped framing 7/8 x 1-3/8
CAN 90˚ 25 18 0.0188 1-1/2 x 1-1/2 10
conditions, soffit framing, floor
2x2
and ceiling runner, chase wall 3x3
construction and laminated gypsum 1-1/2 x 1-1/2
Corner Angle (90º) CANW 135˚ 25 18 0.0188 10
drywall partitions. Custom sizes, 2x2
beads, and lengths are available. HCN (Hemmed) 90˚ 25 18 0.0188 2x2 10
5/8 x 2
7/8 x 1-3/8
CAE 90˚ 20 30 0.0312 1-1/2 x 1-1/2 10
2x2
3x3
1-1/2 x 1-1/2
CAEW 135˚ 20 30 0.0312 10
2x2

Splayed Corner Angle


(120º/135º)

FURRING CHANNEL CLIP

In a ceiling assembly, furring Product code Pcs./Carton


channel clips can be used to MFCC 500
suspend U-channel from the
overhead structure. Drywall furring
channel is commonly clipped or
wire-tied perpendicular to the
underside of the U-channel at
appropriate intervals for screw-
attaching drywall.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 15

Z- F U R R I N G

ClarkDietrich Z-furring is used Thickness


to furr out interior masonry or Product Design Size Length
code Gauge Mils thickness (in) (ft)
poured concrete wall substrates (in)
and to support rigid polystyrene, ZFN1 1
mineral, or fiberglass batt insulation ZFN2
25 18 0.0188
1-1/2
8' 6", 10', 12'
while providing a uniform plane for ZFN3 2
ZFN4 2-1/2
gypsum panel attachment. Z-furring ZFE1 1
should be installed vertically with ZFE2 1-1/2
20 30 0.0312 8' 6", 10', 12'
the 3/4" flange against the substrate. ZFE3 2
The type of fastener and spacing ZFE4 2-1/2
will vary based on application. NOTE: Heavier gauge available upon request.
Install gypsum wallboard parallel or Alternative Product (See page 54):
perpendicular to Z-furring. Z-Girt for Rainscreen Framing (Structural) - Used as a primary rainscreen framing
component providing a uniform plane for cladding attachment. Stocked in galvanized steel.

FURRING CHANNEL

ClarkDietrich furring channel is Thickness


a hat-shaped corrosion-resistant Product
Design thickness
Size Length
code Gauge Mils (in) (ft)
framing component used to furr (in)
out masonry walls and ceiling FCN 25 18 0.0188
assemblies. In concrete wall FCE 20 30 0.0312
7/8 10', 12'
applications, furring channel is FCM 18 43 0.0451
FCM 16 54 0.0566
installed vertically to the wall
FCND 25 18 0.0188
surface using concrete nails FCED 20 30 0.0312
1-1/2 10', 12'
or powder-actuated fasteners. FCMD 18 43 0.0451
7/8" Furring Channel*
Gypsum panels are then screw- FCMD 16 54 0.0566
attached to the furring channels. NOTE: Hemmed leg furring channel (as shown) is only available in 25 gauge.
In ceiling applications, furring
channels can be attached directly
to the underside of the building
structure using tie wire, screws or
powder-actuated fasteners.

1-1/2" Furring Channel*

B A R R I E R M E S H™ & B A R R I E R M E S H ™ C L I P

This tough, rigid heavy-gauge Product


Thickness
Size
SWD LWD C-C
Percent of
Overall Width Length of bond
security mesh is used behind code Gauge
thickness (in)
(in)
(in) (in) (SWD x LWD)
open area
common-wall substrates to protect 18 .038 .500" x 1.26" 61
against break-ins and break-outs. BM50 16 .048 1/2 96 48 .500" x 1.26" 61
Tough to smash or cut, it safeguards 13 .072 .500" x 1.26" 57
16 .048 .923" x 2.10" 76
walls and ceilings in homes,
BM75 13 .072 3/4 96 48 .923" x 2.10" 77
apartments, offices, stores, vaults, 9 .108 .923" x 2.10" 64
storage areas and correctional BM10 16 .048 1 96 48 1.00" x 2.52" 80
facilities. Also fire-resistant, barrier 16 .048 1.33" x 3.15" 82
BM15 13 .072 1-1/2 96 48 1.33" x 3.15" 83
mesh is a cost-effective, time- 9 .108 1.33" x 3.15" 76
saving alternative to reinforced
concrete or concrete block. Product comes standard as carbon steel mesh, complying to ASTM F1267 & ASTM A1011.
Custom designed Barrier Mesh Barrier Mesh Clips (BM-Clips):
Clip to be used when installing Dimensions: 2.75" long, 1.50" wide
Barrier Mesh into walls and ceilings. Packaging: 300 clips/carton, 4 lbs/carton

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
16 DRY WALL FRA MING

P O N Y WA L L H E AV Y (12G A )

Partial wall framing connection to the floor INSTALLATION


The ClarkDietrich Pony Wall Heavy is intended to Install the Pony Wall inside the track or directly to the
support out-of-plane loading of cantilevered partial wall floor structure. Anchor to the floor as designed by
systems that are unsupported at the top track. Out-of- EOR. Attach the studs to both flanges of the Pony
plane loads are transferred to the floor system through Wall. A minimum of 3-1/2" stud member can be used.
the base-plate, which is welded to the Pony Wall Heavy
stud member.

PRODUCT DIMENSIONS
PW24 = 23-3/4" tall with 3-3/8" wide x 8" long plate
PW36 = 35-3/4" tall with 3-3/8" wide x 8" long plate
PW48 = 47-3/4" tall with 3-3/8" wide x 8" long plate

MATERIAL SPECIFICATIONS
ASTM A36 1/2" thick hot rolled steel
Plate Material:

PW48 = 47-3/4”
PW36 = 35-3/4”
PW24 = 23-3/4”
Stud Material:ASTM A1011 SS Grade 50, 50ksi (340 MPa)
12ga (97mil), 0.1017" Design thickness, 0.0966" Min. thickness
Packaging: Individually
ASTM: A36, A1011

Pony Wall Heavy (PW)


Product Thickness
Size (in) Packaging
code Mils (Gauge) Design thickness (in)
PW24 23-3/4" Individually

3-
PW36 97mil (12ga) 0.1017 35-3/4" Individually

3/
PW48 47-3/4" Individually

8”
8”

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 17

Pony Wall Heavy (PW) Allowable Loads CONCENTRATED LOAD AT FREE END

MATERIAL SPECIFICATION
PONY WALL HEAVY STUD
Po
Material Thickness: 12ga (97mil), 0.1017" design thickness in
tL
Material Strength: Structural grade 50, 5
 0ksi minimum yield strength oa
d
ASTM: A1011

PONY WALL HEAVY BASE PLATE


Material Thickness: 1/2" minimum thickness
Material Strength: 36ksi minimum yield strength
ASTM: A36

Pony Wall Heavy (PW) Allowable Loads CONCENTRATED LOAD AT FREE END
Max point load @ cantilever end, lbs Moment (ASD) due to point load, in-lbs
Member Pony Wall
designation Length (in) L/720 L/360 L/240 L/180 Max L/720 L/360 L/240 L/180 Max
M
24 165 330 495 661 763 3,964 7,927 11,891 15,854 18,316
Pony Wall
36 73 147 220 294 509 2,642 5,285 7,927 10,569 18,316
Heavy
48 41 83 124 165 382 1,982 3,964 5,945 7,927 18,316
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Heavy member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between ClarkDietrich Pony Wall Heavy and support structure are designed by others.
6 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
7 Listed maximum point load at cantilever end calculated using maximum allowable moment. When both point load and uniform loads are applied,
combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.

Pony Wall Heavy (PW) Allowable Loads w/Anchors CONCENTRATED LOAD AT FREE END
Max point load @ cantilever end, lbs Allowable base moment, in-lbs
Pony Wall
Member Anchors No. of
length,
designation to structure Anchors L/720 L/360 L/240 L/180 Max L/720 L/360 L/240 L/180 Max
in

1 142 142 142 142 142 3,403 3,403 3,403 3,403 3,403
PW24 24
4 165 330 452 452 452 3,964 7,927 10,840 10,840 10,840
1/2" ɸ Hilti Kwik Bolt-3
(3-1/2" Nominal 1 73 95 95 95 95 2,642 3,403 3,403 3,403 3,403
PW36 36
Embedment, 3000psi 4 73 147 220 294 301 2,642 5,285 7,927 10,569 10,840 (1) Anchor to structure
Uncracked concrete)
1 41 71 71 71 71 1,982 3,403 3,403 3,403 3,403
PW48 48
4 41 83 124 165 226 1,982 3,964 5,945 7,927 10,840

Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4. (4) Anchors to structure
6 Above listed capacities w/anchors shall be used only when using 1/2" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Heavy capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
18 DRY WALL FRA MING

P O N Y WA L L H E AV Y (12G A )

Pony Wall Heavy (PW) Allowable Loads MAXIMUM ALLOWABLE LOADS

MATERIAL SPECIFICATION
PONY WALL HEAVY STUD
Material Thickness: 12ga (97mil), 0.1017" design thickness Po
Material Strength: Structural grade 50, 5
 0ksi minimum yield strength in
tL
ASTM: A1011
oa
d
PONY WALL HEAVY BASE PLATE
Material Thickness: 1/2" minimum thickness
Material Strength: 36ksi minimum yield strength

Uniformly Distributed Load (UDL)


ASTM: A36

Pony Wall Heavy (PW) Allowable Loads


Strength based capacity (ASD)
Member Pony Wall Anchors
designation Length (in) to structure Allowable moment, Max point load @ Max uniform live
in-lbs cantilever end, lbs (UDL) load, lbs/ft
24 763 763
Pony Wall 36 Designed by others 18,316 509 339
48 382 191 M
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported
at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Heavy member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between ClarkDietrich Pony Wall Heavy and support structure are designed by others.
6 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
7 Listed maximum point load at cantilever end calculated using maximum allowable moment. Similarly, listed maximum uniformly
distributed load calculated using maximum allowable moment. When both point load and uniform loads are applied, combined loads
should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.

Uniformly distributed loads are


based on framing members placed
on each side of the Pony Wall
Pony Wall Heavy (PW) Allowable Loads w/Anchors
Strength based capacity (ASD)
Member Anchors Allowable base
designation to structure No. of Anchors
moment,
to Structure
in-lbs
1/2" ɸ Hilti Kwik Bolt-3 1 3,403
PW24 / PW36 /PW48
(3-1/2" Nominal Embedment, 3000psi Uncracked concrete) 4 10,840

Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported
at the top track. (1) Anchor to structure
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Heavy member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
6 Above listed capacities w/anchors shall be used only when using 1/2" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Heavy capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation. (4) Anchors to structure
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 19

Pony Wall Heavy (PW) Allowable Loads UNIFORMLY DISTRIBUTED LOAD

MATERIAL SPECIFICATION
PONY WALL HEAVY STUD
Material Thickness: 12ga (97mil), 0.1017" design thickness
Material Strength: Structural grade 50, 5
 0ksi minimum yield strength
ASTM: A1011

PONY WALL HEAVY BASE PLATE


Material Thickness: 1/2" minimum thickness
Material Strength: 36ksi minimum yield strength

Uniformly Distributed Load (UDL)


ASTM: A36

Pony Wall Heavy (PW) Allowable Loads UNIFORMLY DISTRIBUTED LOAD


Uniformly distributed load, lbs/ft Moment (ASD) due to uniform load, in-lbs
Member Pony Wall
designation Length (in) L/720 L/360 L/240 L/180 Max L/720 L/360 L/240 L/180 Max

24 220 440 661 763 763 5,285 10,569 15,854 18,316 18,316
Pony Wall
36 65 130 196 261 339 3,523 7,046 10,569 14,093 18,316
Heavy
48 28 55 83 110 191 2,642 5,285 7,927 10,569 18,316 M
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported
at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between ClarkDietrich Pony Wall Heavy and support structure are designed by others.
6 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
7 Listed maximum point load at cantilever end calculated using maximum allowable moment. When both point load and uniform
loads are applied, combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.

Uniformly distributed loads are


Pony Wall Heavy (PW) Allowable Loads w/Anchors UNIFORMLY DISTRIBUTED LOAD
based on framing members placed
on each side of the Pony Wall
Uniformly distributed loads, lbs/ft Allowable base moment, in-lbs
Pony Wall
Member Anchors No. of
length,
designation to structure Anchors L/720 L/360 L/240 L/180 Max L/720 L/360 L/240 L/180 Max
in

1 142 142 142 142 142 3,403 3,403 3,403 3,403 3,403
PW24 24
4 165 330 452 452 452 3,964 7,927 10,840 10,840 10,840
1/2" ɸ Hilti Kwik Bolt-3
(3-1/2" Nominal 1 73 95 95 95 95 2,642 3,403 3,403 3,403 3,403
PW36 36
Embedment, 3000psi 4 73 147 220 294 301 2,642 5,285 7,927 10,569 10,840
Uncracked concrete)
1 41 71 71 71 71 1,982 3,403 3,403 3,403 3,403
PW48 48
4 41 83 124 165 226 1,982 3,964 5,945 7,927 10,840
(1) Anchor to structure
Notes:
1 ClarkDietrich Pony Wall Heavy is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Heavy member.
3 ClarkDietrich Pony Wall Heavy is used in conjunction with structural or non-structural studs to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of ClarkDietrich Pony Wall Heavy, use effective moment of inertia = 0.7739 in4.
6 Above listed capacities w/anchors shall be used only when using 1/2" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors. (4) Anchors to structure
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
20 D R Y W A L L F R A M I N G

PONY WALL LITE (16GA)

Partial wall framing connection to the floor INSTALLATION


The ClarkDietrich Pony Wall Lite is intended to support Install the Pony Wall Lite inside the track or directly to
out-of-plane loading of cantilevered partial wall systems the floor structure. Anchor to the floor as designed by
that are unsupported at the top track. Out-of-plane EOR. Attach the studs to both flanges of the Pony Wall
loads are transferred to the floor system through the Lite. A minimum of 2-1/2" stud member can be used.
base-plate, which is welded to the Pony Wall Lite stud
member.
PRODUCT DIMENSIONS
LGPW24 = 23-5/8" tall with 2-3/8" wide x 5-1/2" long plate
LGPW36 = 35-5/8" tall with 2-3/8" wide x 5-1/2" long plate
LGPW48 = 47-5/8" tall with 2-3/8" wide x 5-1/2" long plate
LGPW60 = 59-5/8" tall with 2-3/8" wide x 5-1/2" long plate

LGPW-60 = 59-5/8”
LGPW-48 = 47-5/8”
LGPW-36 = 35-5/8”
LGPW-24 = 23-5/8”
MATERIAL SPECIFICATIONS
Plate Material:ASTM A36 thick hot rolled steel
Stud Material: ASTM A1011 SS Grade 50, 50ksi (340 MPa)
16ga (54mil), 0.0566" Design thickness, 0.0538" Min. thickness
Packaging: Individually
ASTM: A36, A1011

2-
Pony Wall Lite (LGPW)

3/
8”
Product Thickness
Size (in) Packaging
code Mils (Gauge) Design thickness (in)
2”
5 1/
LGPW24 23-5/8"
LGPW36 35-5/8"
54mil (16ga) 0.0566 Individually
LGPW48 47-5/8"
LGPW60 59-5/8"

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
DRY WALL FRA MING 21

Pony Wall Lite (LGPW) Allowable Loads CONCENTRATED LOAD AT FREE END

MATERIAL SPECIFICATION
PONY WALL LITE STUD
Material Thickness: 16ga (54mil), 0.0566" design thickness
Material Strength: Structural grade 50, 5
 0ksi minimum yield strength
ASTM: A1011

PONY WALL LITE BASE PLATE


Material Thickness: 3/8" minimum thickness
Material Strength: 36ksi minimum yield strength
ASTM: A36

Pony Wall Lite (LGPW) Allowable Loads CONCENTRATED LOAD AT FREE END
Max point load @ cantilever end, lbs Moment (ASD) due to point load, in-lbs
Member Pony Wall
designation Length (in) L/240 L/180 Max L/240 L/180 Max

24 86 115 177 2074 2766 4253


Pony Wall 36 38 51 118 1383 1844 4253
Lite 48 22 29 89 1037 1383 4253
60 14 18 71 830 1106 4253

Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between Pony Wall Lite and support structure are designed by others.
6 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
7 Listed maximum point load at cantilever end calculated using maximum allowable moment. When both point load and uniform loads are applied,
combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.

Pony Wall Lite (LGPW) Allowable Loads w/Anchors CONCENTRATED LOAD AT FREE END
Pony Wall Max point load
Member Anchors No. of Allowable base moment, in-lbs
length, @ cantilever end, lbs
designation to structure Anchors
in L/240 L/180 Max L/240 L/180 Max
LGPW24 24 83 83 83 1984 1984 1984
LGPW36 36 3/8" ɸ Hilti Kwik Bolt-3 38 51 55 1383 1844 1984
(2-3/8" Nominal Embedment, 2
LGPW48 48 3000psi Uncracked concrete) 22 29 41 1037 1383 1984
LGPW60 60 14 18 33 830 1106 1984

Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
6 Above listed capacities w/anchors shall be used only when using 3/8" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Lite capacity, but must be designed separately. (2) Anchors to structure
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
22 DRY WALL FRA MING

PONY WALL LITE (16GA)

Pony Wall Lite (LGPW) Allowable Loads MAXIMUM ALLOWABLE LOADS

MATERIAL SPECIFICATION
PONY WALL LITE STUD
Material Thickness: 16ga (54mil), 0.0566" design thickness
Material Strength: Structural grade 50, 5
 0ksi minimum yield strength
ASTM: A1011

PONY WALL LITE BASE PLATE


Material Thickness: 3/8" minimum thickness
Material Strength: 36ksi minimum yield strength
ASTM: A36

Pony Wall Lite (LGPW) Allowable Loads


Strength based capacity (ASD)
Member Pony Wall Anchors Allowable
designation Length (in) to structure Max point load Max uniform live
moment,
@ cantilever end, lbs (UDL) load, lbs/ft
in-lbs
24 177 177
Pony Wall 36 118 79
Designed by others 4253
Lite 48 89 44
60 71 28
Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between Pony Wall Lite and support structure are designed by others.
6 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
7 Listed maximum point load @ cantilever end calculated using maximum allowable moment. Similarly, listed maximum uniformly
distributed load calculated using maximum allowable moment. When both point load and uniform loads are applied, combined loads
should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.

Uniformly distributed loads are


based on framing members placed
on each side of the Pony Wall
Pony Wall Lite (LGPW) Allowable Loads w/Anchors
Strength based capacity (ASD)
Member designation Anchors to structure No. of Anchors Allowable base
to Structure moment, in-lbs

3/8" ɸ Hilti Kwik Bolt-3


LGPW24, LGPW36, LGPW48, LGPW60 (2-3/8" Nominal Embedment, 2 1984
3000psi Uncracked concrete)

Notes: (2) Anchors to structure


1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
6 Above listed capacities w/anchors shall be used only when using 3/8" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Lite capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
D R Y W A L L F R A M I N G 23

Pony Wall Lite (LGPW) Allowable Loads UNIFORMLY DISTRIBUTED LOAD

MATERIAL SPECIFICATION
PONY WALL LITE STUD
Material Thickness: 16ga (54mil), 0.0566" design thickness
Material Strength: Structural grade 50, 5
 0ksi minimum yield strength
ASTM: A1011

PONY WALL LITE BASE PLATE


Material Thickness: 3/8" minimum thickness
Material Strength: 36ksi minimum yield strength
ASTM: A36

Pony Wall Lite (LGPW) Allowable Loads UNIFORMLY DISTRIBUTED LOAD

Member Pony Wall Uniformly distributed load, lbs/ft Moment (ASD) due to uniform load, in-lbs
designation Length (in) L/240 L/180 Max L/240 L/180 Max
24 115 154 177 2766 3688 4253
Pony Wall 36 34 46 79 1844 2458 4253
Lite 48 14 19 44 1383 1844 4253
60 7 10 28 1106 1475 4253

Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through the base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 Base connection between Pony Wall Lite and support structure are designed by others.
6 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
7 Listed maximum uniformly distributed load calculated using maximum allowable moment. When both point load and uniform loads are
applied, combined loads should be limited to maximum allowable moment.
8 It is the responsibility of the designer to properly detail connections on the contract drawings.

Uniformly distributed loads are


based on framing members placed
Pony Wall Lite (LGPW) Allowable Loads w/Anchors UNIFORMLY DISTRIBUTED LOAD on each side of the Pony Wall

Pony Wall
Member Anchors No. of Uniformly distributed loads, lbs/ft Allowable base moment, in-lbs
length,
designation to structure Anchors
in L/240 L/180 Max L/240 L/180 Max
LGPW24 24 83 83 83 1984 1984 1984
LGPW36 36 3/8" ɸ Hilti Kwik Bolt-3 34 37 37 1844 1984 1984
(2-3/8" Nominal Embedment, 2
LGPW48 48 3000psi Uncracked concrete) 14 19 21 1383 1844 1984
LGPW60 60 7 10 13 1106 1475 1984

(2) Anchors to structure


Notes:
1 Pony Wall Lite is intended to support out-of-plane loading of cantilevered partial wall systems that are unsupported at the top track.
2 Out-of-plane loads are transferred to the floor system through base-plate, which is welded to Pony Wall Lite member.
3 Pony Wall Lite may be used in place of standard framing members, or in conjunction with them to frame the wall.
4 Listed allowable loads are based on Allowable Stress Design (ASD).
5 For serviceability/deflection calculations of Pony Wall Lite, use effective moment of inertia = 0.1350 in4 (54mil), 0.1626in4 (68mil)
6 Above listed capacities w/anchors shall be used only when using 3/8" ɸ Hilti Kwik Bolt-3 anchors to concrete.
7 Other anchors may be used to achieve full Pony Wall Lite capacity, but must be designed separately.
8 Above listed capacities have not been increased for wind, seismic, or other factors.
9 Hilti is a registered trademark of Hilti Aktiengeseilschaft Corporation.
10 It is the designer’s responsibility to check for minimum concrete edge distance and minimum concrete thickness when using anchors.
11 It is the responsibility of the designer to properly detail connections on the contract drawings.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
24 S O U N D - R A T E D S Y S T E M S

P r o S T U D® 3 - 5 / 8 " S O U N D A S S E M B L I E S
STC Rating / Test Report
Partition type Assembly description ProSTUD 25 ProSTUD 20
ProSTUD 30mil ProSTUD 33mil
(15mil) (18mil)

3-5/8" ProSTUD
@ 24" o.c.
43 40 37 36
1 layer 5/8" Type X GWB on each side TL09-539 TL19-091 TL20-412 TL13-197

3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation @ 24" o.c.
48 47 40 37
1 layer 5/8" Type X GWB on each side TL09-540 TL19-094 TL20-413 TL13-196

3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation
@ 24" o.c.
49 51 40 42
1 layer 5/8" Type X GWB on one side TL13-167 TL19-092 TL13-202 TL13-195
2 layers 5/8" Type X GWB on the other side

3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation @ 24" o.c.
54 52 42 45
2 layers 5/8" Type X GWB on each side TL09-538 TL19-093 TL13-201 TL13-194

3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation
@ 24" o.c.
54 53 48 50
RC-Deluxe w/ 1 layer 5/8" Type X GWB on one side TL18-302 TL19-097 TL20-414 TL16-369
1 layer 5/8" Type X GWB on the other side

3-5/8" ProSTUD
3-1/2" R-13 unfaced insulation
@ 24" o.c.
59 58 55 56
RC-Deluxe w/ 2 layers 5/8" Type X GWB on one side TL09-543 TL19-096 TL20-415 TL16-370
1 layer 5/8" Type X GWB on the other side

3-5/8" ProSTUD .
3-1/2" R-13 unfaced insulation
@ 24" o.c.
62 60 58 58
RC-Deluxe w/ 2 layers 5/8" Type X GWB on one side TL13-181 TL19-095 TL20-416 TL13-200
2 layers 5/8" Type X GWB on the other side

Notes:
– Sound assemblies are certified by Western Electro-Acoustic Laboratories.
– NVLAP accredited for ASTM E90 & E413, ISO Certified.
– See STC test reports at www.clarkdietrich.com/ProSTUD for detailed requirements of construction of wall assembly.
Contact ClarkDietrich Technical Services at 888-437-3244 for questions about ProSTUD sound assemblies.

Visit itools.clarkdietrich.com for a complete list of sound ratings.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
S O U N D - R A T E D S Y S T E M S 25

Resilient Channels for Walls and Ceilings


ClarkDietrich resilient channel is one of the most efficient low- • Lab-certified STC-rated up to 62
cost methods developed to reduce transmission of airborne sound • Single- and double-leg channels
through partition and ceiling assemblies. The resilient channel
• Choose from five channels; RC Deluxe® has extra-
dampens sound waves effectively, dissipating the energy and
wide screw surface for easy attachment
reducing sound transmission by suspending gypsum wallboard
1/2" from the stud or joist. Sound absorption can be maximized by • Available in 12' lengths
utilizing sound attenuation blankets within the wall or floor cavity. • Possible LEED® benefits listed under IEQ-Acoustic Performance
due to increased STC values. For more information on our
STC assemblies, visit our website at clarkdietrich.com

RC Deluxe® RESILIENT CHANNEL

Made of 22mil steel, RC Deluxe is one of the most Resilient channel should be installed perpendicular
effective, low-cost methods of improving sound to the framing members with the attachment flange
transmission loss through wood and steel frame of the RC Deluxe installed along the bottom edge.
partitions. It is the preferred resilient channel in Channel is prepunched for screw attachments
many applications because of its extra-wide 1-1/2" to wood or steel framing members. Nails are not
screw flange. recommended.

Thickness
Product Design Size Length
code Mils thickness (in) (ft)
(in)
RCSD 22 0.0232 1-1/2 12
Sound assemblies are certified by Western Electro-Acoustic Laboratories.
NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
**Visit iProSTUD.com for current STC ratings.

R C-1 P R O ™ R E S I L I E N T C H A N N E L

Made of 25 gauge steel, RC-1 Pro is used as a cross- Resilient channel should be installed perpendicular
furring member for resilient attachment of gypsum. to the framing members with the attachment flange
Knurled face makes wallboard application easier. of the RC-1 Pro installed along the bottom edge.
Channel is prepunched for screw attachments
to wood or steel framing members. Nails are not
recommended.

Thickness
Product Design Length
Size (in)
code Mils thickness (ft)
(in)
RCUR 18 0.0188 1-1/4 12

Sound assemblies are certified by Western Electro-Acoustic Laboratories.


NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
**Contact our technical services department for current STC information.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
26 S O U N D - R A T E D S Y S T E M S

R C - 1 P r o P l u s™ H E A V Y - D U T Y R E S I L I E N T C H A N N E L

Made of 22mil steel, RC-1 ProPlus is used as a cross- gypsum board. Resilient channel should be installed
furring member for resilient attachment of gypsum. perpendicular to the framing members with the
Knurled face makes wallboard application easier. attachment flange of the RC-1 ProPlus installed
along the bottom edge. Channel is prepunched
RC-1 ProPlus single-leg resilient channel is typically for screw attachments to wood or steel framing
used for applications with multiple layers of members. Nails are not recommended.

Thickness
Product Length
Design Size (in)
code Mils (ft)
thickness (in)

RCUR 22 0.0232 1-1/4 12


Sound assemblies are certified by Western Electro-Acoustic Laboratories.
NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
**Contact our technical services department for current STC information.

R C -2 P r o ™ D O U B L E - L E G R E S I L I E N T C H A N N E L

Made of 25 gauge steel, RC-2 Pro double-leg Resilient channel should be installed
resilient channel is typically used for ceiling perpendicular to the framing members.
applications. It is used as a cross-furring member Channel is prepunched for screw attachments
for resilient attachment of gypsum. Knurled to wood or steel framing members.
face makes wallboard application easier.

Thickness
Product Size Length
code Design (in) (ft)
Mils
thickness (in)

RCDN 18 0.0188 1-1/4 12

Sound assemblies are certified by Western Electro-Acoustic Laboratories.


NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
**Contact our technical services department for current STC information.

R C -2 P r o P l u s™ H E A V Y - D U T Y D O U B L E - L E G R E S I L I E N T C H A N N E L

Made of 22mil steel to provide a stiffer resilient Resilient channel should be installed perpendicular
channel, RC-2 ProPlus heavy-duty double- to the framing members. Channel is prepunched for
leg resilient channel is typically used for ceiling screw attachments to wood or steel framing members.
applications with multiple layers of gypsum board.
It is used as a cross-furring member for resilient
attachment of gypsum. Knurled face makes wallboard
application easier.

Thickness
Product Size Length
code Design (in) (ft)
Mils
thickness (in)

RCDE 22 0.0232 1-1/4 12

Sound assemblies are certified by Western Electro-Acoustic Laboratories.


NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
**Contact our technical services department for current STC information.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
SOUND-R ATED SYSTEMS 27

Installation of Resilient Furring Channel to Steel or Wood Framing Members

Note: These guidelines are for ClarkDietrich's single leg RC Deluxe® and Note 2: Two-legged resilient furring channels may be attached to the wall
RC-1 Pro, and double leg RC-2 Pro. Details of construction for a specific and ceiling framing members using both legs. Alternately attach the legs
assembly to achieve the required fire or sound or acoustic rating shall of the resilient furring channel to the framing members. This method of
be obtained from fire test reports, sound, or acoustic tests, engineering attachment may reduce the sound rating performance of the assembly.
evaluations, or listings from recognized sound or acoustic laboratories. Verify acceptability with the approving authority prior to installation.

Install resilient furring channels at right angles (perpendicular) to the For walls, install the first (lowest) row of resilient furring channel no more
framing members. The resilient furring channel shall be positioned with than 2 in. (51mm) off of the floor and the last (highest) row of resilient
the slotted hole(s) directly over the framing member. The resilient furring furring channel not more than 6 in. (152mm) from the ceiling. For ceilings,
channel shall be attached to the framing member using the screw hole the first row and last row of resilient furring channel shall be located not
provided in the mounting flange. If no screw hole is provided or located at more than 6 in. (152mm) from the adjacent wall. (Measurements are to
the framing member, attach through the mounting flange. the center of the face of the resilient furring channel.)

No more than two layers of up to 5/8 in. (16mm) gypsum panel products Attach resilient furring channel to framing members with screws only. For
should be installed to resilient furring channel. steel framing, Type-S x 3/8 in. (9.5mm) pan-head framing screws may be
used. For wood framing members, Type-W or Type-S screws (minimum
Resilient furring channels should not be spaced greater than 24 in. 1-1/4 in. (32mm) long) may be used. It is not recommended that nails
(610mm) on-center when installed on wall framing members. For ceiling be used. Install the screws in the holes provided in the mounting flange
framing members spaced 24 in. (610mm) on-center, install resilient (whenever possible).
furring channels at 16 in. on-center maximum. For ceiling framing
members spaced 16 in. (406mm) on-center, install resilient furring Splicing of resilient furring channel members shall be done by "nesting"
channels at 24 in. (610mm) on-center maximum. the ends of the resilient furring channel members directly over the
framing member and screwing through the mounting flanges into the
In the case of wall framing members, resilient furring channels should be framing member. (An acceptable alternative would be to butt the resilient
installed with the mounting flange of the resilient furring channel down, furring channel members over the framing member leaving a minimum
except at the floor or starter row where the mounting flange may be 1/16 in. (1.6mm) gap between resilient furring channels.)
installed with the flange up, to accommodate fastening to the framing
members. In the case of two-legged resilient furring channel, attach only Gypsum panel products shall be attached to the resilient furring channel
the lower mounting flange to the wall framing members, except as noted. using a screw length to ensure that the screw point does not make
contact with the framing member. (This will minimize the potential of the
Note 1: By keeping the mounting flange down, the weight of the gypsum screws hitting the wall studs and "short-circuiting" the sound resistance
panel products will pull the resilient channel away from the stud improving effectiveness of the resilient furring channels.)
the sound rating.

CL ARKDIETRICH SOUND CLIP

The ClarkDietrich Sound Clip is


Product weight
used in conjunction with 18mil Product code Gauge (mils) Dimension Pcs./Carton
(lb/piece)
(25ga) 7/8" deep drywall furring 3" x 1-1/4"
CDSC 18ga (43mil) 0.13 100
channel. It is used to fasten gypsum (Clip only)
wallboard to various wall and ASTM, UL and Code Standards can be found at clarkdietrich.com.
floor-ceiling applications, while UL and UL Classified are registered trademarks of Underwriters Laboratories, Inc.
simultaneously providing acoustical
separation. This significantly • Fasteners for Wood:
reduces the amount of impact and #8 x 2-1/2" min size coarse thread screw only-no nails
airborne sound filtering from room • Fasteners for Steel:
to room. The ClarkDietrich Sound #8 x 1-5/8" min size fine thread screws-no nails
Clip adds notable STC points to
most assemblies, while reducing
sound transfer. Please refer to
clarkdietrich.com/support-tools/
support-docs for STC points.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
28 S O U N D - R A T E D S Y S T E M S

BlazeFrame PERIME TER L-BE AD

BlazeFrame® Perimeter L-Bead Width Length Wt./Carton Packaging


Profile
creates an easy attachment that is (in) (ft) (lbs) Pcs./Carton
Perimeter L-Bead 1/2" 8' 24 40
attained with staples through the Perimeter L-Bead with Rip Bead® 1/2" 8 18 30
bead flange. Multiple perforations
When used in conjunction with BlazeFrame Fire Stop Deflection Track Systems,
along the 1-1/8" flange enhance BlazeFrame Perimeter L-Bead is UL 2079-fifth edition compliant. Provides joint
strong compound adhesion and protection for up to 1" with UL 2079 Class II or III Movement Capabilities at 80%
compression.
the raised shoulder provides for a
flush finish. Rigid vinyl is rust proof,
dent resistant and easy to field cut
without distorting profile or leaving
sharp edges and burrs.

Composite Firestop/Framing for


use in fire-resistant joint systems
in or between fire-resistance-rated
walls and floor/ceiling or roof/ceiling
assemblies. Many assemblies can
also be used in smoke barriers with
tested air leakage (L ratings) well
below the code defined maximum of
5 cfm per linear foot.

UltraBEAD

Vinyl L-Bead with compressible Product Width Length Wt./Carton Packaging


foam. UltraBEAD, when used code (in) (ft) (lbs) Pcs./Carton
UltraBEAD 1/2" 8' 24 40
in conjunction with UltraTRAK
slotted deflection track or Deep
Leg deflection tracks, provides joint
protection up to ¾" for a 1 or 2 HR
concrete deck Head of Wall Joint
System at 60% compression.

UltraBEAD with Rip Bead®

Vinyl L-Bead with compressible Product Width Length Wt./Carton Packaging


foam. UltraBEAD, when used code (in) (ft) (lbs) Pcs./Carton
UltraBEAD with Rip Bead® 1/2" 8' 18 30
in conjunction with UltraTRAK
slotted deflection track or Deep
Leg deflection tracks, provides joint
protection up to ¾" for a 1 or 2 HR
concrete deck Head of Wall Joint
System at 60% compression.

UltraBEAD with Rip Bead® creates


a crisp finished edge. Composite
Firestop/Framing for use in
fire-resistant joint systems in or
between fire-resistance-rated walls
and floor/ceiling or roof/ceiling
assemblies.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
H E A D - O F - W A L L S Y S T E M S 29

HE A D - O F-WA LL (H- O -W ) DE FLEC TIO N S YS TEMS

It’s a real challenge these days meeting head-of-wall codes for fire stop and life safety issues while maintaining the ability to
absorb vertical movement in low-, mid- and high-rise buildings. ClarkDietrich has the head-of-wall deflection products and
systems you need for interior wall assemblies subjected to movement—including seismic disturbances.

M a xT r a k ® S L O T T E D D E F L E C T I O N T R A C K

MaxTrak® is a head-of-wall Thickness


Web Leg Standard
deflection track that is used for Product Design width length length
code
framing exterior curtain walls and Gauge Mils thickness (in) (in) (ft)
(in)
nonload-bearing interior walls 2-1/2
where vertical deflection occurs— 3-5/8
and serves as a connecting member MAX 20 33 0.0346 4 2-1/2 10
that isolates the cold-formed steel 6
8
framing system from the movement
2-1/2
of the primary structure. 3-5/8
MAX 18 43 0.0451 4 2-1/2 10
6
8

• Positive attachment with total allowable vertical movement of 1-1/2" (±3/4")


• One-piece system reduces cost of materials and labor
• UL Classified R26034
• Intertek CCRR-0205

M a xT r a k 2 D S L O T T E D D E F L E C T I O N & D R I F T T R A C K

MaxTrak 2D is a head-of-wall Thickness Standard


Product code Web width (in) Leg length (in)
Gauge Mils length (ft)
deflection track that is used for 18 43
framing exterior curtain walls and 16 54 2-1/2 2-1/2 10
nonload-bearing interior walls where 14 68
18 43
vertical deflection and horizontal
16 54 3-5/8 2-1/2 10
drift occurs—and serves as a 14 68
connecting member that isolates 18 43
the cold-formed steel framing SLT/H 16 54 4 2-1/2 10
14 68
system from the movement of the 18 43
primary structure. 16 54 6 2-1/2 10
14 68
18 43
16 54 8 2-1/2 10
14 68

• Total allowable vertical movement of 1-1/2" (±3/4")


• Total allowable horizontal movement (drift) of 4" (±2")
• Slots in web (for seismic design) are 4" long, spaced at 8" o.c.

UL and UL Classified are registered trademarks of Underwriters Laboratories, Inc.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
30 H E A D - O F - W A L L S Y S T E M S

DEEP LEG DEFLEC TION TRACK

This traditional assembly Thickness Web Leg Standard


Product
accommodates the deflection of Design width length length
code Gauge Mils
thickness (in) (in) (in) (ft)
floor beams or floor decks at the 20 33 .0346 3-5/8
head-of-wall. The single long leg 20 33 .0346 6
track assembly requires 1-1/2" 18 43 .0451 3-5/8
cold-rolled channel and 1-1/2" x 18 43 .0451 6
16 54 .0566 3-5/8
1-1/2" 16 gauge EasyClip™ clip TSC
16 54 .0566 6
2 10
angles (U-Series™) installed 14 68 .0713 3-5/8
continuously throughout the 14 68 .0713 6
upper-most punchouts to align 12 97 .1017 3-5/8
12 97 .1017 6
the studs vertically within the 20 33 .0346 3-5/8
plane of the wall. Deflection track 20 33 .0346 6
details must be designed for the 18 43 .0451 3-5/8
18 43 .0451 6
specific conditions of a building 16 54 .0566 3-5/8
to accommodate the required TSE 3 10
16 54 .0566 6
deflection and end reactions of the 14 68 .0713 3-5/8
studs. Deflection tracks cannot 14 68 .0713 6
12 97 .1017 3-5/8
be used in axial load-bearing stud 12 97 .1017 6
conditions or above continuous
NOTE: Custom sizes available upon request.
window spandrels.

D o u b l eTr a c k™ (O V E R T R A C K ) S Y S T E M

ClarkDietrich DoubleTrack™ Thickness


Product Web width Leg length Standard
system is a two-piece assembly code* Gauge Mils
Design (in) (in) length (ft)
that accommodates deflection of thickness (in)
3-3/4
exterior curtain walls. A custom- OTSB 20 30 0.0312
6-1/8
1-1/4 10
made deep leg outer track is 3-3/4
20 30 0.0312
installed to the underside of the 6-1/8
floor deck. A wall assembly is 3-3/4
20 33 0.0346
6-1/8
constructed on the floor and slid 3-3/4
into place, with a "gap" at the top for 18 43 0.0451
6-1/8
OTSC 2 10
deflection. DoubleTrack deflection 16 54 0.0566
3-7/8
assemblies cannot be used in axial 6-1/4
3-7/8
load-bearing stud conditions or 14 68 0.0713
6-1/4
above continuous window spandrels. 3-7/8
12 97 0.1017
6-1/4
3-3/4
20 30 0.0312
6-1/8
3-3/4
20 33 0.0346
6-1/8
3-3/4
18 43 0.0451
6-1/8
OTSE 3 10
3-7/8
16 54 0.0566
6-1/4
3-7/8
14 68 0.0713
6-1/4
3-7/8
12 97 0.1017
6-1/4
NOTE: Custom sizes available upon request.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
HE AD-OF-WALL SYSTEMS 31

F a s t T o p™ C L I P

ClarkDietrich Fast Top™ clips are Thickness


Web Leg Standard
used in head-of-wall deflection Product Design width length length
Packaging
code Gauge Mils thickness Pcs./Carton
conditions for in-fill curtain wall (in)
(in) (in) (ft)
assemblies to provide for vertical FTC3 14 68 0.0713 4 1-1/2 3-1/4 25
movement. These clips are used FTC5 14 68 0.0713 4 1-1/2 4-3/4 30
FTC8 14 68 0.0713 4 1-1/2 7-3/4 25
in place of, or in combination FTC10 14 68 0.0713 4 1-1/2 9-3/4 25
FTC3
with, deflection track. They also FTC12 14 68 0.0713 4 1-1/2 11-3/4 25
make a positive attachment and
FTC3 includes 55 FastClip™ deflection screws per box.
eliminate the need to install bridging
FTC5, FTC8, FTC10 and FTC12 includes 110 FastClip deflection screws per box.
continuously throughout the upper-
U.S. Patent No. 6,688,069
most punchouts. Attach to the
underside of structural members,
concrete decks or floor assemblies.
Studs must be cut less than full
height to enable vertical movement
up to 2-1/2" (1-1/4" up and down).
FTC5

YURCLIP

The YurClip is used in combination Stud size Clip size Packaging


Product code
with deep leg deflection track. (in) (in) Pcs./Carton
YDC2.5 2-1/2 1-1/4 x 2-1/2 x 1 100
Saving labor time, they do not YDC3.625 3-5/8 1-1/4 x 3-5/8 x 1 100
require screws in the stud or
U.S. Patent No. 8,590,257 B2
bridging installed continuously
throughout the upper most
punchouts. YurClips can be installed
on the deflection track or on the
stud first. Adjustable for layout
errors or changes. Wall studs work
in clip either way.

U l t r aT R A K S L OT T E D S Y S T E M

The UltraTRAK slotted system Slot location


Profile Leg length Slot height Joint protection
utilizes a UltraTRAK slotted down from web
UltraTRAK 3.00" 1.50" 1.00" Up to 3/4"
deflection track in conjunction with
the UltraBEAD providing a 1 or 2 Deflection track details must be designed for the specific conditions of a building to accommodate
the required deflection and end reactions of the studs. Deflection tracks cannot be used in axial
HR rated assembly for a ¾” max load-bearing stud conditions or above continuous window spandrels.
joint and is UL 2079-Fifth Edition
Thicknesses: 3 0mil (20ga DW), 33mil (20ga STR), 43mil (18ga) and 54mil (16ga)
compliant. UltraBEAD creates an
Web sizes (W): 2-1/2", 3 -5/8," 4," 6", and 8"
easy attachment that is attained
Vertical slots: 0.22" wide and spaced every 1" o.c.
with staples through the bead flange.
Track Length: 10'-0"
Multiple perforations along the 1-1/8"
flange enhance strong compound
adhesion and the raised shoulder
provides for a flush finish.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
32 H E A D - O F - W A L L S Y S T E M S

UltraBEAD

Vinyl L-Bead with compressible Product Width Length Wt./Carton Packaging


foam. UltraBEAD, when used code (in) (ft) (lbs) Pcs./Carton
UltraBEAD 1/2" 8' 24 40
in conjunction with UltraTRAK
slotted deflection track or Deep
Leg deflection tracks, provides joint
protection up to ¾" for a 1 or 2 HR
concrete deck Head of Wall Joint
System at 60% compression.

UltraBEAD with Rip Bead®

Vinyl L-Bead with compressible Product Width Length Wt./Carton Packaging


foam. UltraBEAD, when used code (in) (ft) (lbs) Pcs./Carton
UltraBEAD with Rip Bead® 1/2" 8' 18 30
in conjunction with UltraTRAK
slotted deflection track or Deep
Leg deflection tracks, provides joint
protection up to ¾" for a 1 or 2 HR
concrete deck Head of Wall Joint
System at 60% compression.

UltraBEAD with Rip Bead® creates


a crisp finished edge. Composite
Firestop/Framing for use in
fire-resistant joint systems in or
between fire-resistance-rated walls
and floor/ceiling or roof/ceiling
assemblies.

UltraBE AD with DEEP LEG DEFLEC TION TR ACK

The UltraBEAD with Deep Leg Product Web Widths


Dimensions
Deflection Track system utilizes code (in)
a deep leg deflection track in UltraBEAD with Deep Leg 2" legs with an
2-1/2", 3-5/8", 4", 6" and 8"
Deflection Track inside depth of the stud
conjunction with the UltraBEAD
providing a 1 or 2 HR rated
assembly for a ¾” max joint and is
UL 2079-Fifth Edition compliant.
UltraBEAD creates an easy
attachment that is attained with
staples through the bead flange.
Multiple perforations along the
1-1/8" flange enhance strong
compound adhesion and the
raised shoulder provides for a flush
finish. Rigid vinyl is rust proof,
dent resistant and easy to field cut
without distorting profile or leaving
sharp edges and burrs. Deflection
track details must be designed for
the specific conditions of a building
to accommodate the required
deflection and end reactions of
the studs. UL Classified and Listed
Joint Systems.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B L A Z E F R A M E T R A C K S 33

DS L 2 (D E E P LEG—S LOT TE D BOTH S ID ES)

Profile with two slotted legs with fire Profile


Leg Tape Slot Joint
length (L) width (I) height (S) protection
stop on both sides. Composite fire DSLE 2 2.50" 0.75" 1.50" 0.50"
stop/framing for use in fire-rated wall DSL 2 3.00" 1.00" 1.50" 0.75"
assemblies. Provides joint protection DSLW 2 3.00" 1.25" 1.50" 1.00"
for up to 1" overall movement with Widths: 2-1/2," 3-5/8," 4," 6" and 8"
UL 2079 Class II or III Movement Thicknesses: 3 3mil (20ga), 43mil (18ga) and 54mil (16ga)
Capabilities. Minimum CP60
coating. Legs with slots spaced 1" o.c.
for positive attachment of studs
per listed assemblies in UL Fire Width
Resistance Directory.
(I) (I)
(L) (L)
(L)
(S)

1.00" .22"
Fastener mid-height of
exposed slot

S L 1 (D E E P LEG—S LOT TE D O NE S ID E)

Profile with one slotted leg and one Profile


Slotted leg Solid leg Tape Slot Joint
length (L1) length (L2) width (I) height (S) protection
solid leg with fire stop on slotted side. SL 1 3.00" 2.00" 1.00" 1.50" 0.75"
Composite fire stop/framing for use SLW 1 3.00" 2.00" 1.25" 1.50" 1.00"
in fire-rated wall assemblies. Provides Widths: 2-1/2," 3-5/8," 4," 6" and 8"
joint protection for up to 1" overall Thicknesses: 3 3mil (20ga), 43mil (18ga) and 54mil (16ga)
movement with UL 2079 Class II or
III Movement Capabilities. Minimum Width
CP60 coating. One leg with slots
spaced 1" o.c. for positive attachment (I)
(L2)
of studs per listed assemblies in UL (L1)
Fire Resistance Directory.

JR (J-RUNNER)

Profile with two solid legs with fire Profile


Front leg Back leg Tape Joint
length (FL) length (BL) width (I) protection
stop on one side. Composite fire stop/ JR 1 2.00" 3.00" 1.00" 0.75"
framing for use in up to three-hour JRW 1 2.00" 3.00" 1.25" 1.00"
fire-rated shaft wall assemblies. Widths: 2-1/2," 4," and 6"
Provides joint protection for up to Thicknesses: 3 3mil (20ga), 43mil (18ga) and 54mil (16ga)
1" overall movement with UL 2079
Class II or III Movement Capabilities.
Width
Minimum CP60 coating. One leg
(front) having intumescent per listed (I)
assemblies in UL Fire Resistance (BL)
(FL)
Directory.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
34 B L A Z E F R A M E T R A C K S

D L (D E E P LEG—SO LID)

Composite fire stop/framing for Profile


Leg Tape Joint
length (L) width (I) protection
use in fire-rated wall assemblies. DLE 2.00" 0.75" 0.50"
Provides joint protection for up to DL 2.00" 1.00" 0.75"
1" overall movement with UL 2079 DLW 2.00" 1.25" 1.00"
Class II or III Movement Capabilities. Widths: 2-1/2," 3-5/8," 4," 6" and 8"
(DL 1 Series) Minimum CP60 coating. Two solid legs Thicknesses: 3 3mil (20ga), 43mil (18ga) and 54mil (16ga) DLE 30mil
supporting “free floating” studs
per listed assemblies in UL Fire
Resistance Directory. Width

(DL 1 Series) Profile with two solid (I) (I)


legs with fire stop on one side (L) (L)
(DL 2 Series) Profile with two solid
(DL 2 Series) legs with fire stop on both sides

BlazeFrame PERIME TER L-BE AD

BlazeFrame® Perimeter L-Bead Width Length Wt./Carton Packaging


Profile
creates an easy attachment that is (in) (ft) (lbs) Pcs./Carton
Perimeter L-Bead 1/2" 8' 24 40
attained with staples through the Perimeter L-Bead with Rip Bead® 1/2" 8 18 30
bead flange. Multiple perforations
When used in conjunction with BlazeFrame Fire Stop Deflection Track Systems,
along the 1-1/8" flange enhance BlazeFrame Perimeter L-Bead is UL 2079-fifth edition compliant. Provides joint
strong compound adhesion and protection for up to 1" with UL 2079 Class II or III Movement Capabilities at 80%
compression.
the raised shoulder provides for a
flush finish. Rigid vinyl is rust proof,
dent resistant and easy to field cut
without distorting profile or leaving
sharp edges and burrs.

Composite Firestop/Framing for


use in fire-resistant joint systems
in or between fire-resistance-rated
walls and floor/ceiling or roof/ceiling
assemblies. Many assemblies can
also be used in smoke barriers with
tested air leakage (L ratings) well
below the code defined maximum of
5 cfm per linear foot.

BlazeFrame® FLUTE COVER

Corrugated strap for horizontal use Design


Profile Gauge Mils Width Length
to span fluted areas of unprotected or thickness
Flute Cover 20ga DW 33 0.0312" 425 (4-1/4"), 675 (6-3/4"), 725 (7-1/4") 10'
protected metal decks in up to 2 hr
rated assemblies. Profile attached to
fluted deck max 16" o.c. on both sides.

Profiles provide a surface area for


attachment of head of wall partition
track profiles centered or offset
underneath and parallel to deck fluted
areas per listed assemblies in UL Fire
Resistance Directory.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B L A Z E F R A M E T R A C K S 35

ODL 2 (OFFSE T DEEP LEG)

Profile with two solid legs with firestop Lower leg length
Profile Tape width (I) Joint protection
on both sides. Composite Firestop (L)
ODL 2 2.00" 1.00" 0.75"
Deflection Track System with "offset ODLW 2 2.00" 1.25" 1.00"
step" accommodates fireproofing up to
When used in conjunction with BlazeFrame Perimeter L-Bead, ODL 2 is UL
1-1/2" thick in head of wall and wall to 2079-fifth edition compliant. Provides joint protection for up to 1" with UL 2079
wall (column) assemblies. Class II or III Movement Capabilities.

Widths: 3-5/8," 4," 6", and 8"


Thicknesses: 3
 3mil (20ga), 43mil (18ga) and 54mil (16ga)

ODSL 2 (OFFSE T DEEP LEG)

Profile with two slotted lower legs Leg length Tape width Slot height
Profile Joint protection
with firestop on both sides. Composite (L) (I) (S)
ODSL 2 3.00" 1.00" 1.50" 0.75"
Firestop Deflection Track System ODSLW 2 3.00" 1.25" 1.50" 1.00"
with "offset step" accommodates
When used in conjunction with BlazeFrame Perimeter L-Bead, ODSL 2 is UL
fireproofing up to 1-1/2" thick in 2079-fifth edition compliant. Provides joint protection for up to 1" with UL 2079
head of wall and wall to wall (column) Class II or III Movement Capabilities.
assemblies. Two legs with slots spaced Widths: 3-5/8," 4," 6", and 8"
1" o.c. for positive attachment of studs. Thicknesses: 3 3mil (20ga), 43mil (18ga) and 54mil (16ga)
Vertical slots: 0.22" wide and spaced every 1" o.c.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
36 B L A Z E F R A M E T R A C K S

B l a z e Fr a m e ® R i pT R A K ™

The BlazeFrame RipTRAK is the Product


Thickness
Lengths Width
only UL tested fire-rated head of code Design Min.
Gauge Mils (ft) (in)
thickness (in) thickness (in)
wall joint system that offers an 20 STR 33 0.0346 0.0329 10
alternate listing by eliminating BlazeFrame 18 43 0.0451 0.0428 10 2-1/2, 3-5/8,
castle cuts and sealant. Meets UL RipTRAK 16 54 0.0566 0.0538 10 4, 6, 8
2079, 5th edition; HW-D-1125 and 14 68 0.0713 0.0677 10
HW-D-0823. For alternate details,
please refer to configuration A,
items 3A1 and 3B1. This is good for
both roof and wall assemblies.

BlazeFrame RipTRAK is a deflection


track with an offset shoulder that
represents the thickness of the
gypsum board (5/8" or 1-1/4”). A
second piece of gypsum board (wall
cladding strips) is fit flush to the
underside of the slab (w/sealant) or
to a fluted deck (without castle cuts
& sealant), and is then fastened to
the shoulder. This allows the roof/
floor assembly and the BlazeFrame
RipTRAK to move in relation to the
wall assembly. This also allows the
wall cladding strips (the rip board)
that is attached to the BlazeFrame
RipTRAK to slide over the primary
wall assembly.

B l a z e Fr a m e ® R i pT R A K ™ S H A F T WA L L

BlazeFrame RipTRAK Shaftwall Product


Thickness
Lengths Width
is a ceiling runner with an offset code Design Min.
Gauge Mils (ft) (in)
thickness (in) thickness (in)
shoulder that represents the 20 STR 33 0.0346 0.0329 10
thickness of the wall material (5/8" BlazeFrame 18 43 0.0451 0.0428 10
2-1/2, 4, 6
or 1-1/4"). A second piece of board/ RipTRAK 16 54 0.0566 0.0538 10
wall material is fit flush to the fluted 14 68 0.0713 0.0677 10
deck or slab and is then attached
to the shoulder. The BlazeFrame
RipTRAK Shaftwall is a UL tested
fire-rated head-of-wall joint system
for up to 4" Total Deflection
Movement.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
D O O R A N D W I N D O W F R A M I N G 37

RedHeader PRO™

Rough openings made easy.


Interior and exterior door and window framing is a whole lot easier with RedHeader PRO™.
RedHeader PRO can cut your labor time in half. It’s designed to replace conventional boxed
headers and built-up jambs and provide better results in half the time. One-piece headers and
jambs eliminate the additional studs, track and screws required to frame conventional rough
openings. Headers and jambs are also pre-cut to specified lengths to eliminate field cutting.

RedHeader PRO HE ADER

Headers are pre-cut to the length Thickness Yield


specified on your order. Header Strength
Depth Flange Return
Design thickness (in) (in) (in)
lengths should be ordered 1/2" Mils (Gauge)
(in) (ksi)
shorter to fit inside clips. All 33 (20) 0.0346 3-5/8, 4 or 6
material CP60. 33 3
43 (18) 0.0451 3-5/8, 4, 6 or 8
54 (16) 0.0566 1
68 (14) 0.0713 50 3-5/8, 4, 6 or 8 3 or 3-1/2
97 (12) 0.1017
Refer to ClarkDietrich.com for additional product information.

RedHeader PRO JA MB

As part of the RedHeader PRO Thickness Yield


system, the jamb eliminates capped Strength Depth (in) Flange (in)
Return
Design thickness (in)
members, allowing drywall screws Mils (Gauge) (ksi)
(in)
to drive through only one thickness 33 (20) 0.0346 3-5/8, 4, 6
33 3
of material. Plus, the open jamb 43 (18) 0.0451 3-5/8, 4, 6, 8
does not require pre-insulating. All 54 (16) 0.0566 1
68 (14) 0.0713 50 3-5/8, 4, 6, 8 3 or 3-1/2
material CP60. 97 (12) 0.1017
Refer to ClarkDietrich.com for additional product information.

HDSC HE ADER BRACKET

The HDSC header bracket is the Thickness


perfect complement to the HDS Yield Strength
Size (in)
Mils (Gauge) Design thickness (in) (ksi)
Framing System. This simple, yet
innovative header bracket turns 3-1/2 x 3-1/16 x 2
a two-person curtain wall header 3-1/2 x 3-9/16 x 2
installation into a one-person job. 3-7/8 x 3-1/16 x 2
This unique, prepunched clip also 3-7/8 x 3-9/16 x 2
33 (20) 0.0346 33
5-7/8 x 3-1/16 x 2
eliminates surface head fastener 5-7/8 x 3-9/16 x 2
buildup that can create finishing 7-7/8 x 3-1/16 x 2
challenges. 7-7/8 x 3-9/16 x 2
3-1/2 x 3-1/16 x 2
3-1/2 x 3-9/16 x 2
3-7/8 x 3-1/16 x 2
3-7/8 x 3-9/16 x 2
68 (14) 0.0713 50
5-7/8 x 3-1/16 x 2
5-7/8 x 3-9/16 x 2
7-7/8 x 3-1/16 x 2
7-7/8 x 3-9/16 x 2
3-1/2 x 3-1/16 x 2
3-1/2 x 3-9/16 x 2
3-7/8 x 3-1/16 x 2
3-7/8 x 3-9/16 x 2
97 (12) 0.1017 50
5-7/8 x 3-1/16 x 2
5-7/8 x 3-9/16 x 2
7-7/8 x 3-1/16 x 2
7-7/8 x 3-9/16 x 2
Refer to ClarkDietrich.com for additional product information.
clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
38 D O O R A N D W I N D O W F R A M I N G

H E A V Y - D U T Y S T U D ( H D S ®) F R A M I N G S Y S T E M

Ultimate load capacity for headers and jambs.


The ClarkDietrich HDS® Framing System provides outstanding bending strength in two
directions and superior axial strength. Plus, it reduces material, labor costs and installation
time by up to 50%. The superior strength and carrying capacity of the HDS means higher
performance with fewer members, like eliminating box beam headers, nesting track and stud
for posts and jambs. It also means improved finish quality by eliminating excessive material
and screw head buildup around doors and windows. The HDSC header bracket is a unique,
prepunched clip that turns a two-person curtain wall header installation into a one-person job.
• Use for curtain wall headers, jambs and sills; drywall headers and jambs; load-bearing jambs, and more.
• Openings up to 20' wide
• Eliminates multi-member built-up truss chords and webs
• Improves drywall finishing around doors and windows

HDS HEADER

This HDS header stud is precut Thickness


Yield
to the length specified length on Design
Strength
Depth Flange Return
Mils (Gauge) thickness (in) (in) (in)
your order. The system provides (in)
(ksi)
cost-effective, member-reducing 3-5/8, 4 3 1-1/16
33 (20), 43 (18) 0.0346, 0.0451 33
framing solutions. Header lengths 6, 8 3 2-1/4
should be ordered 1/2" shorter to fit 3-5/8, 4 3 1-1/16
54 (16), 68 (14), 97 (12) 0.0566, 0.0713, 0.1017 50
inside clips. All material CP60. 6, 8 3 2-1/4

Refer to ClarkDietrich.com for additional product information.

HDS JAMB

As part of the HDS Framing Thickness


Yield
System, the jamb stud eliminates Design
Strength
Depth Flange Return
Mils (Gauge) thickness (in) (in) (in)
capped members, allowing drywall (in)
(ksi)
screws to drive through only one 3-5/8, 4 3 1-1/16
33 (20), 43 (18) 0.0346, 0.0451 33
thickness of material. All material 6, 8 3 2-1/4
is CP60. 3-5/8, 4 3 1-1/16
54 (16), 68 (14), 97 (12) 0.0566, 0.0713, 0.1017 50
6, 8 3 2-1/4

Refer to ClarkDietrich.com for additional product information.

HDSC HE ADER BRACKET

The HDSC header bracket is the Thickness


perfect complement to the HDS Yield Strength
Size (in)
Mils (Gauge) Design thickness (in) (ksi)
Framing System. This simple, yet
innovative header bracket turns 3-1/2 x 3-1/16 x 2
a two-person curtain wall header 3-7/8 x 3-1/16 x 2
installation into a one-person job. 33 (20) 0.0346 33
5-7/8 x 3-1/16 x 2
This unique, prepunched clip also 7-7/8 x 3-1/16 x 2
eliminates surface head fastener 3-1/2 x 3-1/16 x 2
buildup that can create finishing 3-7/8 x 3-1/16 x 2
challenges. 68 (14) 0.0713 50
5-7/8 x 3-1/16 x 2
7-7/8 x 3-1/16 x 2
3-1/2 x 3-1/16 x 2
3-7/8 x 3-1/16 x 2
97 (12) 0.1017 50
5-7/8 x 3-1/16 x 2
7-7/8 x 3-1/16 x 2
Refer to ClarkDietrich.com for additional product information.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
D O O R A N D W I N D O W F R A M I N G 39

L- H E A D E R

ClarkDietrich L-headers are Thickness


Product Leg length
prefabricated, cold-formed 90˚ code Gauge Mils
Design thickness (in)
(in)
L-sections that are used in load-
bearing wall framing. They slide 18 43 0.0451
16 54 0.0566 1-1/2 x 6
easily into place and eliminate 14 68 0.0713
the labor-intensive process of 18 43 0.0451
built-up field-assembled headers. LHDR 16 54 0.0566 1-1/2 x 8
Install as single, one header one 14 68 0.0713
18 43 0.0451
side, or double, two headers, one 16 54 0.0566 1-1/2 x 10
on both sides. 14 68 0.0713
NOTE: Custom lengths available upon request.

UNIVERSAL HE ADER HANG ER (H-SERIES)

The H-Series™ Universal Header Thickness


Product Clip size
Hanger is used to connect box code Gauge Mils
Design thickness (in)
(in)
headers to jambs or beams to columns
and transfer large vertical loads. H436 18 43 0.0451 6 x 8-1/2
H546 16 54 0.0566 6 x 8-1/2
H686 14 68 0.0713 6 x 8-1/2
This universal hanger is designed so
one part can be used for either side
of the connection. The hanger also
features a support tab for proper
alignment and easy installation. The
hanger is also prepunched with a
series of round, square and triangle
holes to ensure proper fastener
placement for specified loads.

HEADER CRIPPLE STUD CLIP

Used with RedHeader PRO™ or Thickness


Product Clip size For header
HDS® Framing System, it eliminates code Gauge Mils
Design thickness (in) size
Clip size
(in)
the header track material and is a
more economical alternative. 1-1/2 x 1-1/2 x 3-3/8 3-5/8" Web 400
1-1/2 x 1-1/2 x 3-3/4 4" Web 200
RCSC-54 16 54 0.0566
1-1/2 x 1-1/2 x 5-3/4 6" Web 100
Extra long return legs on RedHeader 1-1/2 x 1-1/2 x 7-3/4 8" Web 100
PRO and HDS allows for ease 1-1/2 x 1-1/2 x 3-3/8 3-5/8" Web 200
of attachment, Top of header is RCSC-68 14 68 0.0713
1-1/2 x 1-1/2 x 3-3/4 4" Web 200
open, allowing for easy install of the 1-1/2 x 1-1/2 x 5-3/4 6" Web 100
1-1/2 x 1-1/2 x 7-3/4 8" Web 100
insulation. No need to "pre-insulate"
headers prior to installation.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
40 BRIDGING, BRACING AND BACKING

S pazzer ® 9200 S PAC E R A N D B R I D G I N G B A R

The TradeReady® Spazzer® 9200 Product


Thickness
Size
Packaging
bar is a pre-notched, 20 gauge, code Design thickness (in)
Gauge Mils Pcs./Carton Pcs./Skid
(in)
galvanized steel spacer and bridging SPZD 20 33 0.0346 7/8 x 7/8 x 50 25 1350
bar. It facilitates rapid erection of
• Eliminates stud spacing layout at deck
studs into a rigid, accurately laid out
gridwork that has excellent resistance • Improves drywall installation speed
to stud rotation and displacement.
• Automatically positions and rigidly holds studs on 16" or 24" centers
Hanging drywall is also faster and without fasteners
easier because the Spazzer 9200 bar
eliminates the bow that often occurs • Eliminates clip angles and the labor required to install them
in tall interior studs.

U-CHANNEL

ClarkDietrich U-Channel or Cold Thickness


Product code Member Design thickness Size (in)
Rolled Channel (CRC), attached Gauge Mils
(in)
to the studs with clips or weld, are CHN1 075U50-54 16 54 0.0566 3/4
one of the most common bridging CHN2 150U50-54 16 54 0.0566 1-1/2
methods used to provide resistance NOTE: Available in 10', 16' and 20' lengths.
to stud rotation and minor axis Caution:
bending under wind and axial loads. • Clip Angles must be used with screws to brace cold-formed framing properly. U-Channel
1-1/2" U-Channel is passed through does not provide proper bracing if it is not adequately attached to the framing member.
the stud knockout and secured with • Extreme care should be taken in the quality of the weld. If the weld burns through or does
ClarkDietrich's FastBridge Clip, not penetrate, the U-channel will not be effective.
SwiftClip™ (L-Series) or EasyClip™
(U-Series™) Clip Angles and
screws. Lateral bracing is typically
installed at a maximum of 48" O.C.
Consult ClarkDietrich’s Technical
Services for proper spacing. Welding
U-Channel to the stud is acceptable
but should not be used in studs wider
than 6".

S w i f t C l i p™ L S - S e r i e s™ S U P P O R T C L I P

SwiftClip LS-Series™ support clips Thickness


Product Size Packaging
are used in multiple construction code Gauge Mils
Design (in) Pcs./Bucket
thickness (in)
projects, specifically in conjunction
with studs and track. The L-shaped LS543 1-1/2 x 1-1/2 x 3-1/4 300
LS545 1-1/2 x 1-1/2 x 5-1/2 200
clips fit between the stud flanges, so LS547 16 54 0.0566 1-1/2 x 1-1/2 x 7-1/4 150
that shorter length clips do not need LS549 1-1/2 x 1-1/2 x 9-1/4 100
to be ordered. These labor time- LS541 1-1/2 x 1-1/2 x 11-1/4 100
savers include prepunched holes LS683 1-1/2 x 1-1/2 x 3-1/4 300
LS685 1-1/2 x 1-1/2 x 5-1/2 200
for quicker screw attachments,
LS687 14 68 0.0713 1-1/2 x 1-1/2 x 7-1/4 100
and are punched to accommodate LS689 1-1/2 x 1-1/2 x 9-1/4 100
for U-channel lateral bracing LS681 1-1/2 x 1-1/2 x 11-1/4 50
connections. LS973 1-1/2 x 1-1/2 x 3-1/4 200
LS975 1-1/2 x 1-1/2 x 5-1/2 100
LS977 12 97 0.1017 1-1/2 x 1-1/2 x 7-1/4 100
LS979 1-1/2 x 1-1/2 x 9-1/4 50
LS971 1-1/2 x 1-1/2 x 11-1/4 50

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
BRIDGING, BRACING AND BACKING 41

Fa s t B r i d g e™ C L I P

The ClarkDietrich FastBridge™ Clip Thickness


is used to secure 1-1/2" U-channel Product
Design
Packaging
code Gauge Mils Pcs./Bucket
(or Cold Rolled Channel-(CRC)) thickness (in)
to structural wall studs when used
in load-bearing or curtain wall FB33 20 STR 33 0.0346 200
applications. The wall stud friction
fit design allows for as little as one FB43 18 43 0.0451 200
screw for the connection to the
U-channel. Do not use in studs over FB68 14 68 0.0713 200
8" wide.

CC 33 3/4 " C H A N N E L C L I P

Used to secure 3/4" U-Channel Product


Thickness
Weight/Piece Packaging
or Cold Rolled Channel (CRC) code Design (lbs.) Pcs./Bucket
Gauge Mils
thickness (in)
to non-structural wall studs. The CC33 20 33 0.0346 0.12 200
wall stud friction fit design allows
for as little as one screw for the
connection to the U-Channel.

B R I D G I N G T E R M I N AT I O N C L I P

Used to secure U-Channel or Cold Product Stud


Thickness
Packaging
Rolled Channel (CRC) to structural code size Design Min. pcs./bucket
Gauge Mils
thickness (in) thickness (in)
wall studs when used in load- BTC3-43 18 43 0.0451 0.0428 100
bearing or curtain wall applications. BTC3-54 3-5/8" 16 54 0.0566 0.0538 100
The unique design allows for BTC3-68 14 68 0.0713 0.0677 100
BTC4-43 18 43 0.0451 0.0428 100
quicker installation in end-of-wall BTC4-54 4" 16 54 0.0566 0.0538 100
conditions. BTC4-68 14 68 0.0713 0.0677 100
BTC6-43 18 43 0.0451 0.0428 50
BTC6-54 6" 16 54 0.0566 0.0538 50
BTC6-68 14 68 0.0713 0.0677 50

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
42 BRIDGING, BRACING AND BACKING

E a s y C l i p™ U - S e r i e s™ C L I P A N G L E

ClarkDietrich EasyClip U-Series Product


Thickness
Size Packaging
Design thickness
clip angles are used to secure code Gauge Mils
(in)
(in) Pcs./Bucket
U-channel to wall studs for lateral U543 1-1/2 x 1-1/2 x 3-3/8 400
bridging or for miscellaneous rigid U545
16 54 0.0566
1-1/2 x 1-1/2 x 5-3/4 200
connections. U-channel is passed U547 1-1/2 x 1-1/2 x 7-3/4 100
U549 1-1/2 x 1-1/2 x 9-3/4 100
through the stud knockout and an U683 1-1/2 x 1-1/2 x 3-3/8 200
EasyClip U-Series clip is screw- U685 1-1/2 x 1-1/2 x 5-3/4 170
14 68 0.0713
attached or welded to provide U687 1-1/2 x 1-1/2 x 7-3/4 100
U689 1-1/2 x 1-1/2 x 9-3/4 100
a rigid connection. These clips
U973 1-1/2 x 1-1/2 x 3-3/8 200
are prepunched for faster, more U975 1-1/2 x 1-1/2 x 5-3/4 130
12 97 0.1017
accurate fastener placement. Do U977 1-1/2 x 1-1/2 x 7-3/4 100
not use in bridging applications U979 1-1/2 x 1-1/2 x 9-3/4 80
when the stud width exceeds 6."

E a s y C l i p™ X - S e r i e s™ C L I P A N G L E

ClarkDietrich EasyClip X-Series™ Thickness


Product Packaging
Design Size (in)
clip angles are used to secure code Gauge Mils
thickness (in)
Pcs./Bucket
U-channel to wall studs for lateral X543 2 x 2 x 3-3/8 200
bridging. U-Channel is passed X545 2 x 2 x 5-3/4 170
16 54 0.0566
X547 2 x 2 x 7-3/4 100
through the stud knockout and X549 2 x 2 x 9-3/4 100
an EasyClip X-Series clip is screw- X683 2 x 2 x 3-3/8 200
attached or welded to provide a rigid X685
14 68 0.0713
2 x 2 x 5-3/4 100
connection. X-Series clip angles X687 2 x 2 x 7-3/4 100
X689 2 x 2 x 9-3/4 80
and U-channel should not be used X973 2 x 2 x 3-3/8 100
in lateral bridging when stud width X975 2 x 2 x 5-3/4 100
12 97 0.1017
exceeds 6." X977 2 x 2 x 7-3/4 60
X979 2 x 2 x 9-3/4 60

Danback® WO O D B ACKI N G PL AT E

Just snap, flex and screw. It’s that fast. Product Width Length Packaging
code (in) (in) Pcs./Skid
Danback® is a heavy-duty, D16F*
D24F*
flexible wood backing system D16C**
5-1/8 48 250
used to support cabinets, shelves, D24C**
handrails, wall-mounted sinks
• Reduces steel stud backing labor costs by up to 75%
and counters, and all other wall-
mounted fixtures. Danback provides • Available for 16" and 24" o.c. framing
superior connection shear and • Eliminates cutting, notching, ripping and routing
pullout strength to support and • Made with Dricon® fire-retardant treated wood
meet even some of the heaviest
loading conditions. The patented
• Complies with all national building codes
hinge design actually flexes around Dricon® is a registered trademark of Arch Wood Protection, Inc.
the stud and snaps into place for a Danback® is a registered trademark of Daniel W. Tollenaar.
perfect fit—every time. U.S. Patent No. 6,705,056 of Daniel W. Tollenaar.
*F = fire-treated plywood. D16 = 16" o.c. spacing. D24 = 24" o.c. spacing.
Trimmables available for off-module spacing in bulk quantity.
**FSC-certified lumber available upon request, which can contribute to LEED® points on
your project. Contact ClarkDietrich LEED professionals at 888-437-3244 for more
information. FSC chain-of-custody # BV-COC-008121.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B R I D G I N G , B R A C I N G A N D B A C K I N G 43

FastB ack® B AC K I N G C L I P

The FastBack® backing system Product Width Length Packaging


code (in) (in) Pcs./Bucket
features a universal design
FBBC 1-1/4 5-1/8
that works with studs in either FBBC 1-1/4 10-1/4
100
direction—concealing fasteners on
the face of the product. The system U.S. Patent No. 7,882,676 is owned by Jeffery Thomas Ellis.
creates an interlocked design
between the stud and track for
baseboard backing installations; and
a cutaway design allows backing and
bracing to be installed all the way to
the floor.

B ACKI N G PL AT E

ClarkDietrich backing plate is a Thickness


Product Size Length
general multipurpose flat stock code Gauge Mils
Design thickness (in) (ft)
(in)
that is used for backer plate to
support shelves, cabinets, fixtures 2
3
or handrails when applied to metal
4
framing. Backing plate should BPN 25 18 0.0188 6 10
not be used as tension strapping 8
or cross bracing. Commercial 10
Strapping should be used in those 12
2
applications. 3
4
BPE 20 30 0.0312 6 10
8
10
12

K at z™ B L O C K I N G

Katz™ bridging maintains accurate Thickness


Product Size Length
member spacing to prevent code Gauge Mils
Design thickness (in) (in)
(in)
bowing or flexing of nonload-
bearing framing. It can also be KATZ 25 18 0.0188 3-5/8 x 1
16
24
used as backing between studs in
areas where cabinets or fixtures NOTE: 16" available by special order.
are to be attached. Use standard
24" o.c. frame spacing.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
44 BRIDGING, BRACING AND BACKING

BL A ZEFRAME® SHIELD

BlazeFrame Shield is specifically Product


Thickness
Width Horizontal Leg
designed to meet the requirement code Design (in) (in)
Gauge Mils
thickness (in)
of horizontal fire blocking inside 20 STR 33 0.0346
BlazeFrame
the wall system and between floors Shield
18 43 0.0451 3-5/8", 4" or 6" 1"
levels. Pre-notched for use on 16 54 0.0566
structural studs. Lengths: for 16" o.c. and 24" o.c. stud spacing.
Connection Tabs: Top: 2", Bottom: 1-1/2"

NOTCHED TRACK

Notched track is used for bracing Product


Thickness
Width Leg
and bridging of joists and exterior code Design (in) (in)
Gauge Mils
thickness (in)
walls. It's also ideal for use in 4
18 43 0.0451
hospitals and schools as mechanical NOTC
6
1, 1-1/4, 1-1/2
backing to support equipment. 4
16 54 0.0566
6

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B R I D G I N G , B R A C I N G A N D B A C K I N G 45

Spazzer® 5400

ClarkDietrich TradeReady ® Thickness


Product Design Size
Spazzer ® 5400 spacer bar is a code Gauge Mils thickness (in)
Pcs./Carton Pcs./Skid
galvanized steel spacer and bridging (in)
bar, engineered to facilitate the SPZS-54 16 54 0.0566 1-1/4 x 1-1/4 x 50 20 680
SPZS-43 18 43 0.0451 1-1/4 x 1-1/4 x 50 20 680
rapid erection of exterior curtain
wall framing, load-bearing walls and • Fast, easy and efficient
high interior partitions constructed
• Reduces labor up to 40%
of structural studs. Proprietary
prepunched slots provide excellent • Eliminates clip angles, bridging clips and welding
torsional and lateral stud restraint. • Pre-notched at 12," 16" and 24" intervals so no layout is required
U.S. Patent No. 6,708,460 and other patents pending.

S p a z z e r B A R F LY C L I P

The Spazzer fly clip is a secure, Product code Size (in) Packaging Pcs./Carton
SFLY 1 x 1-1/4 x 1 100
fast and efficient way to finish a
wall section. This prepunched clip
eliminates the need for cutting and
bending when using the Spazzer
5400 spacer bar.

Spazzer Bar Guard™

Used to secure the Spazzer 5400 Product Size


Packaging Pcs./Carton
code (in)
spacer bar when used in load- SPBG 3-1/4 x 1-5/8 100
bearing applications.

Spazzer SNAP-IN GROMMET

Used to secure the Spazzer 5400 Product Size


Packaging Pcs./Carton
code (in)
spacer bar when used in curtain SPGR 1-1/2 x 4 100
wall applications.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
46 BRIDGING, BRACING AND BACKING

S w i f t C l i p™ L - S e r i e s™ S U P P O R T C L I P

SwiftClip™ L-Series™ support clips Thickness


Product Design Size Common Packaging
are used in multiple construction code Gauge Mils thickness (in) application Pcs./Bucket
projects, specifically in conjunction (in)
with structural studs and track. LS543 16 54 0.0566 CRC/Openings 300
LS683 14 68 0.0713 1-1/2 x 1-1/2 x 3-1/4 Openings 300
The L-shaped clips fit between the LS973 12 97 0.1017 Openings 200
stud flanges, so that shorter length LS545 16 54 0.0566 CRC/Openings/Joists 200
clips do not need to be ordered. LS685 14 68 0.0713 1-1/2 x 1-1/2 x 5-1/2 Openings/Joists 200
LS975 12 97 0.1017 Openings/Joists 100
LS-Series Support Clip These labor time-savers include
LS547 16 54 0.0566 CRC/Openings/Joists 150
prepunched holes for quicker screw LS687 14 68 0.0713 1-1/2 x 1-1/2 x 7-1/4 Openings/Joists 100
attachments, and are punched LS977 12 97 0.1017 Openings/Joists 100
to accommodate for CRC lateral LS549 16 54 0.0566 Joists 100
LS689 14 68 0.0713 1-1/2 x 1-1/2 x 9-1/4 Joists 100
bracing connections. LS979 12 97 0.1017 Joists 50
LS541 16 54 0.0566 Joists 100
LS681 14 68 0.0713 1-1/2 x 1-1/2 x 11-1/4 Joists 50
LS971 12 97 0.1017 Joists 50
LS5413 16 54 0.0566 Joists 50
LS6813 14 68 0.0713 1-1/2 x 1-1/2 x 13-1/4 Joists 50
LS9713 12 97 0.1017 Joists 25
LE543 16 54 0.0566 Fixed/Joists/Trusses 100
LE683 14 68 0.0713 1-1/2 x 3 x 3-1/4 Fixed/Joists/Trusses 100
LE973 12 97 0.1017 Fixed/Joists/Trusses 50
LE-Series Support Clip LE545 16 54 0.0566 Fixed/Joists/Trusses 100
LE685 14 68 0.0713 1-1/2 x 3 x 5-1/2 Fixed/Joists/Trusses 100
LE975 12 97 0.1017 Fixed/Joists/Trusses 50
LE547 16 54 0.0566 Fixed/Joists/Trusses 100
LE687 14 68 0.0713 1-1/2 x 3 x 7-1/4 Fixed/Joists/Trusses 50
LE977 12 97 0.1017 Fixed/Joists/Trusses 50
LA543 16 54 0.0566 Joists/Trusses 100
LA683 14 68 0.0713 3 x 3 x 3-1/4 Joists/Trusses 100
LA973 12 97 0.1017 Joists/Trusses 50
LA545 16 54 0.0566 Joists/Trusses 100
LA685 14 68 0.0713 3 x 3 x 5-1/2 Joists/Trusses 50
LA975 12 97 0.1017 Joists/Trusses 50
LA547 16 54 0.0566 Joists/Trusses 50
LA-Series Support Clip LA687 14 68 0.0713 3 x 3 x 7-1/4 Joists/Trusses 50
LA977 12 97 0.1017 Joists/Trusses 50

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
B R I D G I N G , B R A C I N G A N D B A C K I N G 47

FL AT S T R A PPI N G

Properly spaced horizontal steel Thickness Size Available


Product Design Length
bracing provides resistance to stud code Gauge Mils thickness
Min. width Max. width (ft)
(in) (in)
rotation and minor axis buckling (in)
under wind and axial loads. Block 20 33 0.0346
DTN3 2 12 10
18 43 0.0451
and strapping is typically used 16 54 0.0566
when wall studs exceed 6." Field cut, DTN5 14 68 0.0713 2 12 10
blocking is used if knockouts do not 12 97 0.1017
align. It’s also used as bridging when DTN3 has a yield strength of 33,000psi.
framing members are unpunched. DTN5 has a yield strength of 50,000psi.

COMMERCIAL STRAPPING

Coil strapping is made in a variety Thickness Size Available


Product
of widths, each with a unique layout code Gauge Mils Width Coil length
of prepunched holes for a variety of
fastening options to meet different CS1-250-33 20 33 1" 250'
application requirements. CS1-250-43 18 43 1" 250'
CS1.5-200-33 20 33 1.5" 200'
CS1.5-200-43 18 43 1.5" 200'
CS2-150-33 20 33 2" 150'
CS2-150-43 18 43 2" 150'
CS2.5-150-33 20 33 2.5" 150'
CS2.5-100-43 18 43 2.5" 100'
CS3-100-33 20 33 3" 100'
CS3-100-43 18 43 3" 100'

BACKER BAR

The ClarkDietrich Backer Bar was Product


Thickness
Lengths Leg Width
specifically designed to meet the code Design Min.
Gauge Mils (in) (in) (in)
thickness (in) thickness (in)
demand for the attachment of BB12 12
multiple items and heavier items to BB16 20 33 0.0346 0.0329 16 1-1/4 5
interior partitions. Provides superior BB24 24
connection shear and pullout
strength for handrails, shelves
and other wall fixtures. Designed,
tested and patented by Bailey®.
Manufactured and distributed in the
USA by ClarkDietrich®.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
48 S H A F T W A L L

ClarkDietrich SHAFTWALL SYSTEM

Tested, approved assemblies with unprecedented flexibility. important wall assemblies in a building. Vertical chases
What makes the ClarkDietrich shaftwall construction and mechanical enclosures keep vital communication,
system unique is that it has been tested with almost every power, water, fresh air and exhaust systems intact when a
gypsum board and shaftliner manufacturer in the country. fire occurs.
Other systems are only tested with one type of gypsum
board and shaftliner. Unlike competing systems, the CONS TRUC TION ME THODS

ClarkDietrich C-T stud and J-tabbed track system provide Cavity shaftwalls are constructed utilizing one of two
maximum flexibility, allowing you to choose from a variety methods: masonry/CMU or cold-formed steel and
of board manufacturers. This unprecedented flexibility gypsum. Gypsum drywall shaftwall construction has
means quick availability of product at economical costs. become the preferred and most widely used shaftwall
assembly. These shaftwalls are lightweight, install faster,
Shaftwall System consists of 1" shaftliner panels and provide lower in-place costs. They also significantly
supported by 2-1/2," 4" or 6" C-T studs and faced on one reduce structural framing and foundation costs, and are
side with varying layers of fire code board. easy, quick and clean to install.

Stairwall Systems are designed to enclose stairwalls, Masonry shaftwalls in high-rise buildings historically
and are finished on both sides with varying layers of fire weigh between 20 and 45 lbs. per square foot,
code board. compared to gypsum assemblies that weigh between
10 and 13 lbs. per square foot. In addition to substantial
LIFE S AFE T Y & FIRE-RESIS TANT PROTEC TION weight reduction, gypsum shaftwall assemblies can be
Shaftwall systems are nonload-bearing, fire-rated wall installed from the exterior of the shaft at each floor,
assemblies that provide critical, life safety, fire-resistant eliminating the need for scaffolding.
protection for elevator shafts, stairwells, vertical chases
and mechanical enclosures. Shaftwalls in elevators and
stairwells provide the only means of evacuation from the
building in an emergency—making them one of the most

Stairwall

Shaftwall

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
S H A F T W A L L 49

C-T S H A F T WA L L / S TA I R W E L L S T U D

Engineered to maintain shaftwall Thickness


Stud
integrity, ClarkDietrich C-T cavity Product
Design depth
code Gauge Mils
shaftwall studs are punched with thickness (in) (in)
1" circular knockouts at 12" o.c. for 250CT-22 25 22 0.0231
easy installation of conduit or other 250CT-33 20 33 0.0346 2-1/2
mechanical service lines. 250CT-43 18 43 0.0451
400CT-22 25 22 0.0231
400CT-33 20 33 0.0346 4
Independent laboratory tests have 400CT-43 18 43 0.0451
demonstrated that the slotting in 600CT-33 20 33 0.0346
6
the web improves resistance to 600CT-43 18 43 0.0451
thermal and noise transmissions
NOTE: 18ga only available in select markets and for interior systems only.
effectively.

J -TA B B E D T R A C K /J - R U N N E R

ClarkDietrich J-tabbed track is Thickness Size


used at the floor and ceiling in Product Design
Width Leg
code Gauge Mils thickness
shaftwall assemblies. C-T studs (in)
(in) (in)
and gypsum shaftliner panels are 250JR-22 2-1/4
2-1/2
friction fit between the top and 250JR3-22 3
25 22 0.0230
bottom J-tabbed track. J-tabbed 400JR-22
4
2-1/4
tracks have unequal legs with the 400JR3-22 3
250JR-33 2-1/4
longer leg (available in 2-1/4" and 250JR3-33
2-1/2
3
3") installed against the shaft. The 400JR-33 2-1/4
20 33 0.0346 4
leg provides a backstop for easy 400JR3-33 3
installation of the shaftliner. Three- 600JR-33 2-1/4
6
600JR3-33 3
inch leg track is typically used as
250JR-43 2-1/4
jamb struts around closure details, 250JR3-43
2-1/2
3
including duct and door openings, 400JR-43 2-1/4
18 43 0.0451 4
abutments and intersections. 400JR3-43 3
600JR-43 2-1/4
6
ClarkDietrich J-tabbed track is 600JR3-43 3

punched with fold-up tabs every *2 designates 2-1/4" leg; 3 designates 3" leg
12," permitting faster, more efficient PEI Evaluation Report AER-12061
installation. NOTE: 18ga only available in select markets and for interior systems only.

B l a z e Fr a m e ® R i pT R A K ™ S H A F T WA L L

BlazeFrame RipTRAK Shaftwall Product


Thickness
Lengths Width
is a ceiling runner with an offset code Design Min.
Gauge Mils (ft) (in)
thickness (in) thickness (in)
shoulder that represents the 20 STR 33 0.0346 0.0329 10
thickness of the wall material (5/8" BlazeFrame 18 43 0.0451 0.0428 10
2-1/2, 4, 6
or 1-1/4"). A second piece of board/ RipTRAK 16 54 0.0566 0.0538 10
wall material is fit flush to the fluted 14 68 0.0713 0.0677 10
deck or slab and is then attached
to the shoulder. The BlazeFrame
RipTRAK Shaftwall is a UL tested
fire-rated head-of-wall joint system
for up to 4" Total Deflection
Movement.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
50 A R E A S E P A R A T I O N W A L L

Cl a r kDi e t r i c h A R E A S E PA R AT I O N WA L L S Y S T E M

Fire-resistance protects lives and property. installed between 2" H-studs spaced 24" o.c. At the top
Area separation walls are nonload-bearing, 2-hour and and bottom of the walls, C-runners (or H-tracks) are
3-hour rated vertical wall assemblies that provide fire- installed back-to-back between vertically stacked panels.
resistant protection between adjacent living units in Overall stacked area separation wall assemblies cannot
apartment buildings, condominiums and townhouses. They exceed 50 feet or the limits of the applicable UL Fire
are also referred to as party walls, firewalls, multi-family Assembly.
walls and H-stud assemblies.
A photo of an area separation wall system after a fire is
Assembled between two independent walls, area separation shown below. Although this was a tragic event, it clearly
walls form a commonly shared party wall that extends proves the effectiveness of the system. It performed
from the foundation through the roof line. The walls are as designed by maintaining the integrity of the firewall,
assembled with two 1"-thick gypsum panel liners vertically protecting the lives and property of the adjacent units.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
ARE A SEPAR ATION WALL 51

H-S TUD

ClarkDietrich H-studs are 2" wide Thickness Size


vertical members used to secure two Product
code Design thickness Width Length
1" thick pieces of gypsum shaftliner Gauge Mils
(in) (in) (ft)
in area separation wall assemblies. 8
H-studs are inserted into C-runners HSN 25 18 0.0188 2-1/16 10
and slid over gypsum panel liner 12
edges, repeating until the desired NOTE: Two- or three-hour fire-rated assembly.
wall length is achieved. Once the
wall is plumbed, it is secured with
aluminum burn clips.

C- R U N N E R

ClarkDietrich C-runner (or Thickness Size


H-track) is used to secure H-stud Product
code Design thickness Length
and gypsum shaftliner panels in Gauge Mils
(in)
Width (in)
(ft)
area separation wall assemblies.
8
Attached to the foundation HRN1 25 18 0.0188 2-1/8
10
with powder-actuated fasteners,
NOTE: Two- or three-hour fire rated assembly.
C-runner is also used as top track
to cap the H-stud and gypsum
shaftliner panels, with a second
track screwed back-to-back to
the lower runner, to hold the next
assembly level.

ALUMINUM BURN CLIP

ClarkDietrich aluminum burn clips


Product code Thickness (in) Size (in) Packaging Pcs./Bucket
are used as part of the H-stud area
separation wall assembly and are AB 0.050 2 x 2 x 2-1/2 500
AB63 0.063 2 x 2 x 2-1/2 500
designed to melt when exposed
AB30 0.063 2x2x3 250
to fire. The clips hold the area AB35 0.063 2 x 2 x 3-1/2 250
separation wall assemblies in place AB40* 0.063 2x2x4 250
at the floor, roof and truss line AB45 0.063 2 x 2 x 4-1/2 250
between adjacent units. In a fire,
*For use with 3-hour Design Assembly based on GA file No. ASW 2600. Other custom
the aluminum burn clips on the
breakaway clip lengths available.
fire-ridden side of the wall will melt,
NOTE: Check listed fire assembly for details of construction, thickness and length of
allowing the wall structure for that
required burn clips.
side to collapse.
All burn clips are manufactured using 5052 H32 aluminum.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
52 C U R T A I N W A L L F R A M I N G

C-S T U D S

C-Studs (C-Series™) Two of the key differences between the various


Cold-formed C-shaped framing members for axial load- C-stud/Joist framing members are the flange and return
bearing walls, curtain walls, tall interior partitions, floor dimensions. The flange is typically the bearing surface
joists and roof truss assemblies. for cladding materials and a key contributor to the load-
bearing capacity of the member.

ClarkDietrich CWN™ 1-3/8" Flange Product Thickness Depth Flange Return


Member gauge
Curtain wall studs have a 1-3/8" flange and code* (mils) (in) (in) (in)
3/8" return and are used to support the 250S137-x 2-1/2
362S137-x 20 (33), 3-5/8
exterior skin or cladding material (metal, CWN3 (20 & 18 gauge) 18 (43), 16
400S137-x 4 1-3/8 3/8
stone, tile, glass, etc.) and the wind loads CWN5 (16 & 14 gauge) (54), 14
600S137-x (68) 6
they are subjected to. 800S137-x 8

ClarkDietrich CSJ™ 1-5/8" Flange Product Thickness Depth Flange Return


Member gauge
Studs/joist have a 1-5/8" flange and a 1/2" code*
(mils) (in) (in) (in)
return and are considered the industry 250S162-x 2-1/2
standard. CSJ members are the most widely 350S162-x 3-1/2
362S162-x 3-5/8
used and specified framing members. They 20 (33),
400S162-x 4
provide the vertical strength necessary CSJ3 (20 & 18 gauge) 550S162-x
18 (43),
5-1/2
for demanding load-bearing structural 16 (54), 1-5/8 1/2
CSJ5 (16, 14 & 12 gauge) 600S162-x 6
14 (68), 12
applications and sufficient strength for many 800S162-x (97) 8
joist applications. 1000S162-x 10
1200S162-x 12
1400S162-x 14

ClarkDietrich CSW™ 2" Flange Product Thickness Depth Flange Return


Member gauge
Wide studs/joist have a 2" wide flange code*
(mils) (in) (in) (in)
and a 5/8" return that provides a 362S200-x 3-5/8
larger bearing surface for attaching 400S200-x 20 (33), 4
600S200-x 18 (43), 6
sub-flooring or sheathing materials. CSW3 (20 & 18 gauge)
800S200-x 16 (54), 8 2 5/8
This framing member is also used in CSW5 (16, 14 & 12 gauge)
1000S200-x 14 (68), 12 10
axial load-bearing wall assemblies. 1200S200-x (97) 12
1400S200-x 14

ClarkDietrich CSE™ 2-1/2" Flange Product Thickness Depth


gauge Flange Return
Member
Extra-wide studs/joist have a 2-1/2" wide code* (mils) (in) (in) (in)
flange and a 5/8" return and are used in floor 362S250-x 3-5/8
joist assemblies and heavy loading conditions. 400S250-x 20 (33), 4
600S250-x 18 (43), 6
CSE3 (20 & 18 gauge)
800S250-x 16 (54), 8 2-1/2 5/8
CSE5 (16, 14 & 12 gauge)
1000S250-x 14 (68), 12 10
1200S250-x (97) 12
1400S250-x 14

ClarkDietrich CSS™ 3" Flange Product Thickness Depth Flange Return


Member gauge
Super-wide studs/joist have a 3" flange and code*
(mils) (in) (in) (in)
a 5/8" return and are used in very heavy 600S300-x 6
18 (43),
loading and long spanning conditions. CSS3 (18 gauge)
800S300-x
16 (54),
8
1000S300-x 10 3 5/8
CSS5 (16, 14 & 12 gauge) 14 (68), 12
1200S300-x (97) 12
1400S300-x 14

*20 and 18 gauge are standard as 33ksi yield strength. 16, 14 and 12 gauge are standard as 50ksi yield strength.
x = mil thickness identifier

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
C U R T A I N W A L L F R A M I N G 53

K N O C KO U T S /K N O C KO U T PAT T E R N

ClarkDietrich cold-formed C-studs for axial load- Knockouts are punched 12" o.c. from the lead edge
bearing and curtain wall framing are prepunched with with additional knockouts every 24" o.c. (on the
knockouts at regular intervals. These punchouts are West Coast, the first knockout is punched 24" o.c.
specifically designed to allow for rapid installation of from the lead edge). Caution must be exercised when
pipes, electrical conduit and wall bridging. installing studs so knockouts align for bridging. Based
on stud length, the distance the knockout falls from
Standard knockout sizing is 1-1/2" x 4" in members the tail end of the stud may not be the same from the
3-1/2" and wider. Members smaller than 3-1/2" are lead end. To align punchouts, make sure to use the
unpunched unless otherwise specified at time of same end in the same direction consistently.
order. If specified, members will be punched with a
3/4" x 4" knockout.

2-1/2" 3-1/2" and


wide studs wider studs

GROMMETS

Grommets snap easily into stud Product code Size (in) Description Pcs./Carton
knockouts and are used to protect
3/4 For 1-5/8" and 2-1/2" studs
electrical wiring and plumbing GROM
1-1/2 For 3-1/2" and wider studs
100
lines from contacting metal.
Grommets are commonly used
when metal conduit is not required
2-Piece Grommet by building code.

Snap-In Bushing

STRUC TURAL TRACK

ClarkDietrich structural track is a Thickness


Leg
Product code Member Design
U-shaped framing component used Gauge Mils length (in)
thickness (in)
as top and bottom runners to secure TSA x-T100-y 1
wall studs. Structural track is also TSB x-T125-y 1-1/4
used as end support closures for TSF x-T150-y 20, 18, 33, 43,
2-1/2, 3-1/2, 1-1/2
3-5/8, 4, 5-1/2, 6, 8,
joists at exterior or foundation walls, TSC x-T200-y 16, 14, 12 54, 68, 97
10, 12, 14 2
head and sill plates of wall openings TSD x-T250-y 2-1/2
and solid blocking. Track is normally TSE x-T300-y 3
ordered in corresponding size and x = Part depth. Tracks are available to match all stud and joist depths.
gauge to the wall studs. y = Mil thickness of steel.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
54 C U R T A I N W A L L F R A M I N G

CORNER ANGLE

ClarkDietrich heavy-gauge corner Product


Thickness
Size* Length*
Design
or utility angle is commonly used for code Gauge Mils
thickness (in)
(in) (ft)
a variety of applications including: CAE 20 33 0.0346
concrete pour stop, connection 18 43 0.0451
16 54 0.0566 2x2 10
strut or angle, roof ridge angles and CAM
14 68 0.0713
corner reinforcement. 12 97 0.1017
CAE 20 33 0.0346
18 43 0.0451
16 54 0.0566 3x3 10
CAM
14 68 0.0713
12 97 0.1017

NOTE: Other sizes available upon request.

H E AV Y- D U T Y F U R R I N G C H A N N E L

ClarkDietrich heavy-duty furring Thickness


Product Size Length
Member Design
channel is a high-performance code Gauge Mils
thickness (in)
(in) (ft)
framing component used in 087F125-43 18 43 0.0451
FCM 7/8 10, 12
ceiling, exterior wall and roof 087F125-54 16 54 0.0566
applications. With two standard FCMD
150F125-43 18 43 0.0451
1-1/2 10, 12
150F125-54 16 54 0.0566
depths—7/8" and 1-1/2"—heavy-
duty furring channel provides
greater resistance to deflection
and bending. In roof applications,
heavy-duty furring is used as purlins
to provide connection points for
roof sheathing.

Z- G I R T F O R R A I N S C R E E N F R A M I N G

ClarkDietrich Z-Girt is used as Thickness


Product code Material Size Design Length
a primary rainscreen framing Gauge Mils
thickness (in)
component with depths matching 150ZG-33 1-1/2"
common exterior insulation 200ZG-33 2"
thicknesses while providing 250ZG-33 2-1/2"
33ksi, G90 20ga 33mils 0.0346" 12'-2"
a uniform plane for cladding 300ZG-33 3"
attachment. It can be installed in a 350ZG-33 3-1/2"
horizontal or vertical orientation. 400ZG-33 4"
The type of fastener and spacing 150ZG-43 1-1/2"
will vary based on application. 200ZG-43 2"
250ZG-43 2-1/2"
33ksi, G90 18ga 43mils 0.0451" 12'-2"
300ZG-43 3"
350ZG-43 3-1/2"
400ZG-43 4"
150ZG-54 1-1/2"
200ZG-54 2"
250ZG-54 2-1/2"
50ksi, G90 16ga 54mils 0.0566" 12'-2"
300ZG-54 3"
350ZG-54 3-1/2"
400ZG-54 4"

NOTE: 14ga available upon request.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
F L O O R F R A M I N G 55

FLOOR FRAMING

You can have confidence in the strength of steel For all of these reasons, steel floor framing has
under your feet. become the standard for low- and mid-rise commercial
Floor framing made from cold-formed steel is stronger and structures such as hotels, apartments, condominiums
more versatile. Its high strength-to-weight ratio provides and assisted living, as well as residential homes.
strong loading capacity and maximum spanning capability.
• Available in a variety of web sizes, flanges, thicknesses and
It can be used with all traditional flooring materials such as yield strengths
plywood, OSB, concrete-filled steel deck or one of the many • Pre-spaced joist tabs
varieties of fiber-reinforced cement board. It doesn’t squeak • Greater spanning capabilities
when you walk across it. • Prepunched openings
• Full system of joist components, accessories,
What’s more is that ClarkDietrich’s exclusive TradeReady® hangers and connectors

Floor System is designed with large extruded openings in the


joists to accommodate electrical, mechanical, plumbing and
technology lines. These prepunched openings also eliminate
drilling and soffit framing during installation.

THE ClarkDietrich TradeReady FLO OR S YS TEM

The revolutionary TradeReady Steel Joist System features a tabbed rim track to strengthen the joist against web crippling
loads, and to provide greater versatility and strength for ledger applications. In conjunction with other floor sheathing
products, this system provides one of the most cost-effective systems for non-combustible low- and mid-rise structures.

• Prepunched openings eliminate drilling/cutting joist webs, and soffit framing

• Sustainable alternative to wood joists, offering long-term price stability

• Pre-spaced joist tabs eliminate layout, and joist hangers

• Greater spanning capabilities for design flexibility

- Wider o.c. spacing for fewer joists

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information Pub. No. CD-Framing 9/24
56 F L O O R F R A M I N G

Tr a d e Re a d y ® S T E E L J O I S T

ClarkDietrich TradeReady® steel Thickness


joists meets the requirements of Product Depth Flange Return
ksi
code (in) (in) (in)
most typical building layout and Mils (gauge) Design thickness
floor/roof loads. Large extruded
43mil = 33ksi 43mil (18ga) 0.0451 design thickness, 7-1/4, 8,
holes (spaced at 24" o.c.) TDJ 54mil (16ga) 0.0566 design thickness, 9-1/4, 1-3/4
accommodate HVAC, mechanical, 5/8
54, 68, 97mil = 68mil (14ga) 0.0713 design thickness, 11-1/4
plumbing, electrical and sprinkler 50ksi 97mil (12ga) 0.1017 design thickness
TDW 10, 12, 14 2
runs. The joist also features a series
UL and UL Classified are trademarks of Underwriters Laboratories, Inc.
of smaller holes for electrical and
UL listed assemblies: G535, G536, G551, G553, G578, G579, G591, H516,
technology lines. Hole sizes range
from 4-1/4" oval to 10" round, based L564, M564, P546, P561 and P562.
on member depth. *Note: 7-1/4" and 8" deep members are not included in UL listings.

They offer consistent quality,


predictable performance and high TradeReady Joist
strength-to-weight ratio. . Extruded hole size
Hole shape
Web width
(in) (in)

4-1/4 x 7 7-1/4 TDJ, 8 TDJ

9-1/4 TDJ, 10 TDW,


6-1/4 x 9
11-1/4 TDJ

8 Diam. 12 TDW

10 Diam. 14 TDW

Tr a d e R e a d y R I M

Another major component of the Thickness Flange Length Tab


Depth
TradeReady floor system, the Product code Top Bottom spacing
Mils (gauge) Design thickness (in)
(in) (in) (in)
standard 12'-long rim drastically
reduces framing time and effort. TD12, 43mil (18ga) 0.0451 design thickness,
7-1/4, 8,
Rims have pre-formed, prepunched TD16, 54mil (16ga) 0.0566 design thickness,
9-1/4, 10, 2 2
12, 16,
attachment tabs at 12", 16", 19.2" TD19, 68mil (14ga) 0.0713 design thickness, 19.2, 24
11-1/4, 12, 14
TD24 97mil (12ga) 0.1017 design thickness
or 24" o.c. spacing to eliminate
layout time—and ensure fast,
proper fastener placement.
Embossed stiffening ribs on each
side of the tabs provide additional
reinforcement, for a significant
reduction of web stiffeners (squash
blocks) and support clips in a
majority of applications.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
F L O O R F R A M I N G 57

Tr a d e R e a d y ® S T R U C T U R A L B R I D G I N G

The third component of the Thickness


TradeReady® Floor System, Effective
Design Depth Packaging
Product code length
TradeReady Structural Bridging Gauge Mils thickness (in) Pcs./Bundle
(in)
(in)
is pre-cut to fit securely between
the underside of the floor joists to TDSB 12
TDSB 16
prevent joist rotation. Prepunched TDSB
18 43 0.0451 2-1/2
19.2
10
for quick attachment, it's an TDSB 24
economical alternative to cross NOTE: TDSB bridging is not required if sheathing is applied to the joists top and bottom.
bracing, X-bracing or strapping. For
easy attachment, install continuous Caution: To prevent joist rolling, TDSB bridging must be tied into the structure or
row of blocking every 8' o.c. otherwise braced against lateral movement.
maximum, and staggered.

Tr a d e R e a d y ® F L O O R J O I S T B L O C K I N G

TradeReady Floor Joist Blocking Thickness Packaging


Product code Joist size (in) Hole size (in)
Gauge Mils Pcs./Carton
features a large extruded hole to
725JB 7-1/4" 4-1/2" x 7"
accommodate HVAC, mechanical, 800JB 8" 4-1/2" x 7"
plumbing and sprinkler runs. 925JB 9-1/4" 6-1/2" x 9"
1000JB 16 54 10" 6-1/2" x 9" 10
TradeReady Blocking is pre-cut and 1125JB 11-1/4" 6-1/2" x 9"
formed to fit securely between the 1200JB 12" 6-1/2" x 9"
floor joists to prevent joist rotation. 1400JB 14" 6-1/2" x 9"
Prepunched holes in the connection
legs are added for quick attachment to
each floor joist.

E a s y C l i p™ Q u i c kTw i s t ™ W E B S T I F F E N E R

Thickness
EasyClip™ QuickTwist™ web Product
Size (in)
Height*
Packaging
code Design (in)
stiffeners are used to provide Gauge Mils
thickness (in)
reinforcement of joist webs 7-1/4
to prevent crippling. Web 8
9-1/4
reinforcement is often required QTWS 3-1/2 12 97 0.1017 10
Dependent on
by design to enhance the load order quantity
11-1/4
capacity of joists. The unique 12
design of QuickTwist allows the 14
7-1/4
installer to insert the stiffener 8
on the inside of the joist after the 9-1/4
Dependent on
joist is installed. This stiffener QTWS 6 12 97 0.1017 10
order quantity
11-1/4
eliminates the need to pre-insert
12
traditional web stiffeners prior to 14
joist installation. The one-piece
assembly is easily rotated in NOTE: Dimension is nominal size. Actual product is shorter to fit inside joist.
place for a tight fit.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information Pub. No. CD-Framing 9/24
58 F L O O R F R A M I N G

STRUC TURAL RIM TRACK

Structural track, usually in the same Thickness


gauge as the joist, is used as rim or Product
Member Design
Depth Flange
code (in) (in)
band enclosures. Gauge Mils thickness
(in)
800T125-x 18 43 0.0451 8
1000T125-x 16 54 0.0566 10
TSB 1-1/4
1200T125-x 14 68 0.0713 12
1400T125-x 12 97 0.1017 14
NOTE: 18 gauge is standard as 33ksi yield strength. 16, 14, and 12 gauge are standard as
50ksi yield strength.
Depth of TSB is measured to the inside of the flanges.

L I G H T- G AU G E C-J O I S T F R A M I N G

ClarkDietrich C-joist components Thickness


Product Depth Flange Return
provide an economical, lightweight code*
Member
Design (in) (in) (in)
Gauge Mils
alternative to open web trusses, thickness (in)
bar joists, engineered lumber, 800S162-x 18 43 0.0451 8
cast-in-place or hollow core floor 1000S162-x 16 54 0.0566 10
CSJ 1-5/8 1/2
1200S162-x 14 68 0.0713 12
assemblies. Plus, they’re pre-cut to 1400S162-x 12 97 0.1017 14
save time. Depending on loads and 800S200-x 18 43 0.0451 8
spans, C-joists are typically spaced CSW
1000S200-x 16 54 0.0566 10
2 5/8
1200S200-x 14 68 0.0713 12
at 12," 16," 19.2" or 24" o.c. Joist-to-
1400S200-x 12 97 0.1017 14
girder attachments are normally 800S250-x 18 43 0.0451 8
supported with joist hangers, CSE
1000S250-x 16 54 0.0566 10
2-1/2 5/8
EasyClip E-Series™ or S-Series™ 1200S250-x 14 68 0.0713 12
1400S250-x 12 97 0.1017 14
support clips. Web stiffeners may 800S300-x 18 43 0.0451 8
be required at supports and other 1000S300-x 16 54 0.0566 10
CSS 3 1
point loads. 1200S300-x 14 68 0.0713 12
1400S300-x 12 97 0.1017 14
NOTE: 18 gauge is standard as 33ksi yield strength. 16, 14, and 12 gauge are standard as
50ksi yield strength.

COMMERCIAL STRAPPING

Coil Strapping is made in a variety Thickness Size Available


of widths, each with a unique layout Product code
Gauge Mils Width Coil Length
of prepunched holes for a variety of CS1-250-33 20 33 1" 250'
fastening options to meet different CS1-250-43 18 43 1" 250'
application requirements. CS1.5-200-33 20 33 1.5" 200'
CS1.5-200-43 18 43 1.5" 200'
CS2-150-33 20 33 2" 150'
CS2-150-43 18 43 2" 150'
CS2.5-150-33 20 33 2.5" 150'
CS2.5-100-43 18 43 2.5" 100'
CS3-100-33 20 33 3" 100'
CS3-100-43 18 43 3" 100'

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
F L O O R F R A M I N G 59

E a s y C l i p™ E - S e r i e s™ S U P P O R T C L I P

ClarkDietrich EasyClip™ E-Series™ Product


Thickness
Size Packaging
Design thickness
support clips are used for rigid code Gauge Mils
(in)
(in) Pcs./Bucket
standoff connections. The 4" wide E543 4 x 1-1/2 x 3 100
leg provides extra length to achieve E545 4 x 1-1/2 x 5 100
standoff connections up to 3." E547 16 54 0.0566 4 x 1-1/2 x 7 100
E549 4 x 1-1/2 x 9 50
These support clips are commonly E541 4 x 1-1/2 x 11 50
used in bypass wall conditions, a E683 4 x 1-1/2 x 3 100
variety of floor framing applications E685 4 x 1-1/2 x 5 100
E687 14 68 0.0713 4 x 1-1/2 x 7 80
including solid and ladder blocking E689 4 x 1-1/2 x 9 50
attachments and joist-to-joist E681 4 x 1-1/2 x 11 50
connections, and to secure rafter E973 4 x 1-1/2 x 3 50
framing to the primary structure. E975 4 x 1-1/2 x 5 50
E977 12 97 0.1017 4 x 1-1/2 x 7 50
EasyClip E-Series support clips are E979 4 x 1-1/2 x 9 50
prepunched for faster and more E971 4 x 1-1/2 x 11 40
accurate fastener placement.

E a s y C l i p S - S e r i e s™ S U P P O R T C L I P

ClarkDietrich EasyClip S-Series™ Product


Thickness
Size Packaging
Design thickness
support clips are commonly used code Gauge Mils
(in)
(in) Pcs./Bucket
for rigid connections in window and S543 1-1/2 x 1-1/2 x 3 400
door framing, joist, bypass or other S545 1-1/2 x 1-1/2 x 5 200
miscellaneous connections to secure S547 16 54 0.0566 1-1/2 x 1-1/2 x 7 100
S549 1-1/2 x 1-1/2 x 9 100
one framing member to another, S541 1-1/2 x 1-1/2 x 11 100
or to secure framing members to S683 1-1/2 x 1-1/2 x 3 200
the structural frame. This high- S685 1-1/2 x 1-1/2 x 5 200
S687 14 68 0.0713 1-1/2 x 1-1/2 x 7 100
performance multi-use utility clip
S689 1-1/2 x 1-1/2 x 9 100
is ideal for corner reinforcements, S681 1-1/2 x 1-1/2 x 11 100
stair openings and numerous S973 1-1/2 x 1-1/2 x 3 200
support applications. EasyClip S975 1-1/2 x 1-1/2 x 5 150
S977 12 97 0.1017 1-1/2 x 1-1/2 x 7 100
S-Series clips are prepunched for S979 1-1/2 x 1-1/2 x 9 80
faster and more accurate fastener S971 1-1/2 x 1-1/2 x 11 70
placement.

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information Pub. No. CD-Framing 9/24
60 F L O O R F R A M I N G

BRIDLE HANGER

Bridle hangers are commonly Thickness


used to attach cold-formed Product Design Width (W) Depth (H) Packaging
code Gauge Mils thickness (in) (in) Pcs./Carton
C-joists to structural steel (in)
beams, wood ledgers or masonry CDBV 1-5/8 x 6 1-5/8 6 25
block. Connections can be made CDBV 1-5/8 x 8
14 68 0.0713
1-5/8 8 25
CDBV 1-5/8 x 10 1-5/8 10 25
with screws, powder-actuated
CDBV 1-5/8 x 12 1-5/8 12 25
fasteners, drill-in concrete CDBV 2 x 6 2 6 25
anchors or welding. Single- and CDBV 2 x 8
14 68 0.0713
2 8 25
double-wide hangers are also CDBV 2 x 10 2 10 25
CDBV 2 x 12 2 12 25
available in other widths and CDBV 4 x 6 4 6 25
depths. The MB hanger can also CDBV 4 x 8 4 8 25
14 68 0.0713
be sloped to a maximum of 45.̊ CDBV 4 x 10 4 10 25
Skew only: MB series can be CDBV 4 x 12 4 12 25
CDMB 2 x 8 2 8 25
skewed to a maximum of 45˚— CDMB 2 x 10 2 10 25
maximum allowable download is CDMB 2 x 12 12 97 0.1017 2 12 25
62% of table load. CDMB 4 x 8 4 8 25
CDMB 4 x 10 4 10 25
MB: Slope 0˚ to 30,̊ maximum allowable download is 100% of table load.
Slope 31˚ to 45,̊ maximum allowable download is 80% of table load.

UNIVERSAL JOIST HANGER

The Universal Joist Hanger Product


Thickness
Packaging
code Yield Design Min. pcs./bucket
is used to connect joists to Gauge Mils
strength thickness (in) thickness (in)
UJH-68 14 68 50 ksi 0.0713 0.0677 50
CFS headers (with screws, UJH-97 12 97 50 ksi 0.1017 0.0966 50
welds or PAF fasteners) and
steel I-beams (with welds or
PAF fasteners). The UJH is
sized to fit joist sizes from 8"
to 14" deep.

S KE WA B LE A NG LE

ClarkDietrich Skewable Thickness


Size Packaging
Product code Design (in) pcs./bucket
Angles are used to make Gauge Mils
thickness (in)
SA3 3
rigid attachments of joist- SA4 4
to- joist or joist-to-other- SA5
SA6
18 43 0.0451
5
6
100

miscellaneous framing. This SA7 7


SA9 9
clip is ideal for making off-
angle connections. It is easily
field bent from 0° to 135°.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
INDEX 61

Product Name Index


360TRAK™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Heavy-Duty Furring Channel . . . . . . . . . . . . . . . . . 54 SwiftClip Support Clip . . . . . . . . . . . . . . . . . . . . 40, 46
Heavy-Duty Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
A How to Use This Catalog . . . . . . . . . . . . . . . . . . . . . . 7-8 T
Area Separation Wall Systems . . . . . . . . . . . . . . . 50-51 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Aluminum Burn Clip . . . . . . . . . . . . . . . . . . . . . . . . . . 51 J TRAKLOC Drywall Framing . . . . . . . . . . . . . . . . 12-13
J-Runner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 TradeReady Floor Joist Blocking . . . . . . . . . . . . . . . . 57
B J-Tabbed Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 TradeReady Floor System . . . . . . . . . . . . . . . . . . 55-57
Backer Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 TradeReady Rim Track . . . . . . . . . . . . . . . . . . . . . . . . 56
Backing Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 K TradeReady Steel Joist . . . . . . . . . . . . . . . . . . . . . . . 56
Backing Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Katz Blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 TradeReady Structural Bridging . . . . . . . . . . . . . . . . 57
Barrier Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Barrier Mesh Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 ksi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 U
BlazeFrame Flute Cover . . . . . . . . . . . . . . . . . . . . . . 34 U-Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
BlazeFrame Tracks . . . . . . . . . . . . . . . . . . . . . . . . 33-36 L U-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
BlazeFrame Perimeter L-Bead . . . . . . . . . . . . . . 28,34 L-Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 UltraBEAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28, 32
BlazeFrame Perimeter L-Bead w/Rip Bead® . . 28,34 L-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 UltraBEAD w/Deep Leg Deflection Track . . . . . . 32
BlazeFrame RipTRAK . . . . . . . . . . . . . . . . . . . . . . . . 36 LS-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40, 46 UltraBEAD w/Rip Bead® . . . . . . . . . . . . . . . . . . 28, 32
BlazeFrame RipTRAK Shaftwall . . . . . . . . . . . . 36,49 LEED Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 UltraTRAK Slotted System . . . . . . . . . . . . . . . . . . . . 31
BlazeFrame Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6, 63 Universal Header Hanger . . . . . . . . . . . . . . . . . . . . . 39
Bridging Termination Clip . . . . . . . . . . . . . . . . . . . . . . 41 Universal Joist Hanger . . . . . . . . . . . . . . . . . . . . . . . 60
Bridle Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
M
MaxTrak Slotted Deflection Track . . . . . . . . . . . . . . 29 W
C Miscellaneous Angles . . . . . . . . . . . . . . . . . . . . . . . . 54 Web Stiffener . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
C-Joist Framing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
C-Runner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
N X
C-Studs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Notched Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 X-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
CC33 Channel Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 O Y
C-T Shaftwall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Offset Deep Leg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Channel Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Yield Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ClarkDietrich Sound Clip . . . . . . . . . . . . . . . . . . . . . . 27 P YurClip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Clip Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42, 54 Plastic Grommets . . . . . . . . . . . . . . . . . . . . . 14, 45, 53
Pony Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-23
Z
Clip Express . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Z-Furring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Commercial Strapping . . . . . . . . . . . . . . . . . . . . 47, 58
Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Z-Girt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Contact Information . . . . . . . . . . . . . . . . . . . . . . . 6, 63
Product Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Corner Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14, 54 Product Code Index
Curtain Wall Framing . . . . . . . . . . . . . . . . . . . . . 52-54 Product Substitution . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ProSTUD Drywall Framing System . . . . . . . . . . . 9-10 360FT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
D ProSTUD Sound Assemblies . . . . . . . . . . . . . . . . . . 24
Danback Wood Backing Plate . . . . . . . . . . . . . . . . . 42 ProTRAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
A
Deep Leg Deflection Track . . . . . . . . . . . . . . . . . . . . 30 Protective Coatings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 AB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Deep Leg-Slotted . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 B
Deep Leg-Solid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Q
QuickTwist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 BB12/16/24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Deflection Track . . . . . . . . . . . . . . . . . . . . . . . . . . 29, 30
BM10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Door and Window Framing . . . . . . . . . . . . . . . . . 37-39 R
Double Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 BM15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RC-1 Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
BM50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RC-1 ProPlus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
E RC-2 Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
BM75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
E-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 BM-Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RC-2 ProPlus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
EasyClip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42, 57, 59 BPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
RC-Deluxe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Engineering Services . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 BPN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
RedHeader PRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
F Resilient Channel . . . . . . . . . . . . . . . . . . . . . . . . . 25-26
BTC3/4/6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Fast Top Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Resilient Channel Installation . . . . . . . . . . . . . . . . . . 27 C
FastBack Backing Clip . . . . . . . . . . . . . . . . . . . . . . . . 43 Rough Openings . . . . . . . . . . . . . . . . . . . . . . . . . . 37-38
FastBridge Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 CAE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Fire Stop Tracks . . . . . . . . . . . . . . . . . . . . . . . . . . 33-36 S CAE 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Flat Strapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 S-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 CAEW 135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Floor Framing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55-60 SFIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Flute Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Shaftwall Systems . . . . . . . . . . . . . . . . . . . . . . . . 48-49 CAN 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Furring Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Skewable Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 CANW 135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Furring Channel Clip . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Slotted Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CC33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Sound Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 CDBV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
G Sound-Rated Systems . . . . . . . . . . . . . . . . . . . . . 24-28 CDMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
General Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Spazzer Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40, 45 CDSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Grommets . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14, 45, 53 Spazzer Bar Fly Clip . . . . . . . . . . . . . . . . . . . . . . . . . . 45 CHN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Spazzer Bar Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 CSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52, 58
H Spazzer Snap-In Grommet . . . . . . . . . . . . . . . . . . . . 45 CSJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52, 58
H-Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Standards & Specifications . . . . . . . . . . . . . . . . . . 8, 63 CSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52, 58
INDEX

HDS Framing System . . . . . . . . . . . . . . . . . . . . . . . . 38 Steel Thickness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52, 58


HDSC Header Bracket . . . . . . . . . . . . . . . . . . . 37, 38 Structural Rim Track . . . . . . . . . . . . . . . . . . . . . . . . . 58 CT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Head-of-Wall Systems . . . . . . . . . . . . . . . . . . . . 29-32 Structural Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 CWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Header Cripple Stud Clip . . . . . . . . . . . . . . . . . . . . . 39 Support and Services . . . . . . . . . . . . . . . . . . . . . . . . . . 5

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
62 I N D E X

Product Code Index


D K S
D16, D24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 KATZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 S-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
SA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
DL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 L SFLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
DLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 L-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
DLW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 SL 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
LGPW24/36/48/60 . . . . . . . . . . . . . . . . . . . . . . 20-23
DSL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SLT/H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
LHDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DSLE 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SLW 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
LS-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40, 46
DSLW 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SPBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
DTN3/5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 M SPGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
MAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 SPZD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
E MFCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 SPZS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
E-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
N T
F NOTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 TD12, 16, 19, 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
FB33/43/68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
O TDJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
FBBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 TDSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
ODL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
FCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 TDW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
ODLW 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
FCED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 TLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13
ODSL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
FCM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15, 54 TLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13
ODSLW 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
FCMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15, 54 TSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
OTSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
FCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 TSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53, 58
OTSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
FCND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 TSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30, 53
OTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
FTC3/5/8/10/12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 TSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
P
G PDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30, 53
GROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14, 53 TSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
PDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
H PRO HEADER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 U
H436/546/686 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 PRO JAMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 U-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
HCN90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 PW24/36/48 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-19 UJH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
HDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Q X
HDSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37, 38 QTWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 X-Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
HRN1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
HSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 R Y
RCDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 YDC2.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
J RCDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 YDC3.625 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
JB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 RCSC-54/-68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
RCSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Z
JR 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 ZFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RCUR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26
JRW 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 ZFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

PATENTS/TRADEMARKS/WARRANT Y

Patents Trademarks
U.S. Patent Nos. 5
 ,689,922; 5,816,002; ClarkDietrich is a registered trademark of ClarkDietrich Building Systems. ProSTUD®, ProTRAK®, TRAKLOC®,
6,070,374; 6,301,854; TradeReady®, Spazzer ®, FastClip™, EasyClip™, Fast Top™, Fast Strut™, FastBridge™, Uni-Clip™, Clip ExpressSM ,
6,418,694; 6,688,069; Stronger Than SteelSM , FastBack™, HDS®, RedHeader PRO™, QuickTwist™, Slide Clip™, SubmittalPro®,
6,691,478; 6,691,487; SwiftClip™, A-Series™, B-Series™, D-Series™, E-Series™, G-Series™, GP-Series™, H-Series™, L-Series™,
6,708,460; 6,761,005; LS-Series™, LE-Series™, LA-Series™, S-Series™, T-Series™, U-Series™, X-Series™, MaxTrak®, Bar Guard™,
7,240,459 DoubleTrack™ QC-Series™, Katz™, BackerBead®, E-Flange™, DiamondPlus®, ClarkDietrich Sound Clip™, RC
Canadian Patent No. 2319346 Deluxe® Resilient Channel and 360TRAK™ are owned by ClarkDietrich.
Barrier Mesh,™.
Mexican Patent No. 243294
U.S. Patent No. 6,705,056 is owned by Daniel DriCon® is a registered trademark of Arch Wood Protection, Inc.
W. Tollenaar LEED® is a registered trademark of the U.S. Green Building Council.
Danback® is a registered trademark of Daniel W. Tollenaar.
U.S. Patent No. 7,882,676 is owned by Jeffery
UL® and UL Design® are trademarks of Underwriters Laboratories, Inc.
Thomas Ellis

Warranty
Our products are manufactured in accordance with company standards and/or industry standards, as applicable. All ClarkDietrich products are covered by our standard
warranty which is contained in our Standard Terms and Conditions of Sale and which will be provided upon request. Generally, we warrant our products will be free from
defects in material and workmanship at the time of shipment, subject to the limitations stated in the warranty. Unless specifically agreed in writing by us with respect to
specific orders, we do not make any warranty of merchantability or fitness for a particular purpose. The buyer is responsible to assure that buyer orders the appropriate
product for any applicable code or specification requirements.

NOTICE: Our liability is expressly limited to replacement of defective products. We shall not be liable for incidental and consequential damages, nor for any loss caused
by misuse or misapplication of our products. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from the date it was or reasonably
should have been discovered.

Pub. No. CD-Framing 9/24 The technical content of this literature is effective 09/30/24 and supersedes all previous information. clarkdietrich.com
63

C O D E A P P R O VA L S A N D P E R F O R M A N C E S TA N D A R D S
ClarkDietrich products meet or exceed these applicable performance standards.

ProSTUD® Drywall Framing Standards LEED® Services


AISI S100-16 (2020) w/S2-20 - North American Specification for the Design of CFS Structural Members BUILD GREEN with ClarkDietrich
AISI S220-20 - North American Standard for Cold-Formed Steel Framing Nonstructural Members
ClarkDietrich is an active member of the U.S. Green Building Council and
(Compliant to ASTM C645, but IBC replaced with AISI S220 in IBC 2015)
is committed to supplying quality products that are environmentally
Section A3 Material - Chemical & mechanical requirements (Referencing ASTM A1003/A1003M)
responsible. We are continually working to develop greener building
Section A4 Corrosion Protection (Referencing ASTM A653/A653M)
Section A5 Products - Thickness, shapes, tolerances, identification products and sustainable business practices. ClarkDietrich steel
Section C Installation (Referencing ASTM C754) framing helps contribute points toward LEED ® certification. For
more details contact Technical Services at 888-437-3244 or visit
ClarkDietrich Nonstructural Framing comply with: www.clarkdietrich.com/LEED.
IBC-2024 - International Building Code
Intertek CCRR-0207 SustainabilityPro
LA RR #26019 - City of Los Angeles ProSTUD Research Report
SFIA (Steel Framing Industry Association) Code Compliance Certification Program Quickly access the product-specific information and certifications
UL 263 "Fire Tests of Building Construction and Materials" needed to calculate contributions to LEED ® and other green building
ASTM E119 - Standard Test Methods for Fire Tests of Building Construction and Materials certification and rating systems - all in one platform.
ASTM E72 - Standard Test Methods of Conducting Strength Tests of Panels for Building Construction Find out more at www.clarkdietrich.com/LEED.
ASTM E90 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building
Partitions and Elements ClarkDietrich has prepared this literature with the utmost diligence
Multiple UL® design listings for ProSTUD: and care for accuracy and conformance to standards.
Over 50 UL Designs. See UL file number R26512 for additional information.
UL® and UL® Design are service marks of Underwriters Laboratories, Inc. ClarkDietrich intends this information to be accurate, informative,
U.S. Patent No. 9,010,070 and helpful as a selection guide for choosing ClarkDietrich products.
However, this information is only to be used for guidance and is
Structural Framing Standards not intended to replace the design, drawings, specifications, and
decisions of a professional architect or engineer.
AISI S100-16 (2020) w/S2-20- North American Specification for the Design of CFS Structural Members
AISI S240-20 - North American Standard for Cold-Formed Steel Structural Framing ClarkDietrich or its affiliates shall not be responsible for incidental or
(Compliant to ASTM C955, but IBC replaced with AISI S200 in IBC 2014, AISI S240 in IBC 2018) consequential damages, directly or indirectly sustained, nor for loss
Section A3 Material - Chemical & mechanical requirements (Referencing ASTM A1003/A1003M) caused by application of our products for other than their intended
Section A4 Corrosion Protection (Referencing ASTM A653/A653M) uses. Our liability is limited to replacement of defective products.
Section A5 Products - Thickness, shapes, tolerances, identification Claims shall be deemed waived unless they are made to us in writing
Section C Installation (Referencing ASTM C1007) within thirty (30) days of the date a problem was or reasonably should
have been discovered.
ClarkDietrich Structural Framing comply with:
IBC-2024 - International Building Code ClarkDietrich reserves the right to modify
Intertek CCRR-0206 - Structural Studs and Track or change any information contained in
SFIA (Steel Framing Industry Association) Code Compliance Certification Program this literature without notification.
ICC-ES ESR-1166P
For the most up to date version of all
ClarkDietrich literature, scan the QR code.

Structural Framing and Drywall Framing Standards


AISI S202-20 - Code of Standard Practice for Cold-Formed Steel Structural Framing
Section F3 Delivery, handling and storage of materials USGBC and related logo is a
trademark owned by the
U.S. Green Building Council
and is used by permission.

ClarkDietrich is a proud member of the Steel Framing Industry Association (SFIA). Check the
updated list of Certified Production Facilities at Intertek's website at www.intertek.com.
LOCATIONS

ClarkDietrich Manufacturing and Sales Locations: ClarkDietrich Engineering Services.


CALIFORNIA Riverside CALIFORNIA Sacramento CONNECTICUT Bristol FLORIDA Dade City A full spectrum of solutions.
P 951.360.3500 P 951.360.3500 P 866.921.0023 P 352.518.4400
Toll-Free Phone: 877.832.3206
Toll-Free Fax: 877.832.3208
FLORIDA Miami GEORGIA McDonough ILLINOIS Rochelle MARYLAND Baltimore Technical Services: 888.437.3244
P 305.477.6464 P 678.304.5500 P 800.659.0745 P 410.477.4000 Email: [email protected]

MISSOURI O'Fallon OHIO Warren—East OHIO Vienna OKLAHOMA Oklahoma City CENTRAL Merrillville, IN SOUTHEAST McDonough, GA
P 636.300.1411 P 330.372.5564 P 330.372.4014 P 405.896.2563
NORTHEAST Bristol, CT WEST Carlsbad, CA

TEXAS Dallas TEXAS Pasadena CLIP EXPRESS ℠ —East


P 214.350.1716 P 281.383.1617 P 866.638.1908

clarkdietrich.com The technical content of this literature is effective 09/30/24 and supersedes all previous information. Pub. No. CD-Framing 9/24
Online Revision: pgs. 16-23 Pony Wall product images
6/23/2022 - pg. 60 - Universal Joist Hanger product image
6/23/2022 - pg. 19 - Pony Wall Chart update
7/27/2022 - pg. 15 - Z-Furring Chart update
12/9/2022 - pg. 43 - Updated FastBack™ chart and image
6/27/2023 - pg. 48 - Updated Shaftwall chart
9/5/2023 - pg. 51 - AB clip material note
9/15/2023 - pg. 63 - Structural Code Approvals
10/01/2023 - pg. 63 - Structural Code Approvals
11/3/2023 - pgs. 37-38 - HDS® and RedHeader PRO™ image and chart changes
9/30/2024 - pg. 63 - Structural Code Approvals

Turn to ClarkDietrich for a complete lineup of steel construction products and services nationwide:

Interior Framing ∙ Exterior Framing ∙ Interior Finishing ∙ Exterior Finishing∙ Clips/Connectors ∙ Engineering

9050 Centre Pointe Dr. Suite 400 P 513.870.1100 clarkdietrich.com


West Chester, OH 45069 F 513.870.1300 Clarkwestern Dietrich Building Systems LLC

CD-Framing 9/24 © ClarkDietrich Building Systems. The technical content of this literature is effective 09/30/24 and supersedes all previous information.

You might also like