Lighting

MASTER LEDtube EM/


Mains T8
MAS LEDtube 1200mm UO 14.7W 840 T8
The Philips MASTER LEDtube integrates a LED light source into a traditional
fluorescent form factor. Its unique design creates a perfectly uniform visual
appearance which cannot be distinguished from traditional fluorescent. This product
is the ideal solution for up lamping in general lighting applications.

Warnings and Safety


•-
•-

Product data

General Information Flickering value (PstLM) - Flickering value as per 0.5

Cap-Base G13 ROT EN 61000-3-3

Nominal lifetime 75,000 hour(s) Stroboscopic effect visibility measure (SVM) 0.2

Switching Cycle 200,000 Photobiological safety according to EN 62471 RG0

Lighting Technology LED

Flux measurement reference Sphere Operating and Electrical


Line Frequency 50 to 60 Hz

Light Technical Input Frequency 50 to 60 Hz

Color Code 840 [CCT of 4000K] Power Consumption 14.7 W

Beam Angle (Nom) 160 degree(s) Lamp Current (Max) 74 mA

Luminous Flux 2,500 lm Lamp Current (Min) 61 mA

Luminous Efficacy (rated) (Nom) 170 lm/W Starting Time (Nom) 0.5 s

Color Designation Cool White (CW) Warm-up time to 60% light 0.5 s

Correlated Color Temperature (Nom) 4000 K Power Factor (Fraction) 0.9

Color Consistency <6 Voltage (Nom) 220-240 V

Color rendering index (CRI) 80 LED alternative to fluorescent lamp power 36 W

LLMF At End Of Nominal Lifetime (Nom) 70 % Inrush current at mains 8.4

Datasheet, 2023, April 15 data subject to change


MASTER LEDtube EM/Mains T8

Max. lamp no. on MCB B type 10A - Mains 90 Energy Saving Product Yes

Max. lamp no. on MCB B type 10A – EM ballast 100 Approval Marks RoHS compliance CE marking

without Compensation Capacitor. KEMA Keur certificate ENEC

Max. lamp no. on MCB B type 10A – EM ballast 15 certificate

with Compensation Capacitor. Energy Consumption kWh/1000 h 15 kWh

Max. lamp no. on MCB B type 16A - Mains 140 EPREL Registration Number 1206974

Max. lamp no. on MCB B type 16A – EM ballast 160 CE mark Yes
without Compensation Capacitor. EU RoHS compliant Yes
Max. lamp no. on MCB B type 16A – EM ballast 25

with Compensation Capacitor. Product Data


Ballast Compatibility EM/Mains Order product name MAS LEDtube 1200mm UO 14.7W

840 T8
Temperature Full product name MAS LEDtube 1200mm UO 14.7W
Ambient temperature range -20 °C to 45 °C 840 T8

T-Case Maximum (Nom) 55 °C Full product code 871951431658400

Order code 929002998302

Controls and Dimming Material Nr. (12NC) 929002998302

Dimmable No Numerator - Quantity Per Pack 1

Net Weight (Piece) 0.230 kg

Mechanical and Housing EAN/UPC - Product/Case 8719514316584

Bulb Finish Frosted Numerator - Packs per outer box 10

Bulb Material Plastic EAN/UPC - Case 8719514316591

Product Length 1,200 mm

Bulb Shape T8

Approval and Application


Energy Efficiency Class C

Dimensional drawing

A3 Product D1 D2 A1 A2 A3

MAS LEDtube 1200mm UO 14.7W 25.8 mm 28 mm 1,198.2 mm 1,205.3 mm 1,212.4 mm

A2 840 T8

A1
D1
D2

Datasheet, 2023, April 15 2 data subject to change


MASTER LEDtube EM/Mains T8

Photometric data

General uniform lighting - MAS LEDtube 1200mm UO 14.7W 840 T8 Light Distribution Diagram - MAS LEDtube 1200mm UO 14.7W 840 T8

100
Intensity (%)

80

60

40

20

0
200 300 400 500 600 700 800
[nm]

Spectral Power Distribution Colour - MAS LEDtube 1200mm UO 14.7W 840


T8

Lifetime

100 100%
Lumen in %

90
98%
Lumen (%)

80
96%
70

60 94%

50
0 20000 40000 60000 80000 100000 92%
55 60 65 70 75
Burning hours
Tc(°C)

Lumen Maintenance Diagram - MAS LEDtube 1200mm UO 14.7W 840 T8 Lumen Maintenance Diagram - MAS LEDtube 1200mm UO 14.7W 840 T8

Datasheet, 2023, April 15 3 data subject to change


MASTER LEDtube EM/Mains T8

Lifetime

100 100
Failure rate in %

Failure rate in %
80 80
75
60 60
65
40 40
55
20 20

0 0
0 20000 40000 60000 80000 100000 0 20000 40000 60000 80000 100000
Time (hours)
Time (hours)

FailureRate Life Expectancy Diagram

100000

80000
Life time (Hours)

60000 B10L70

40000
B50L70
20000

0
55 65 75
Tc(°C)

LifetimeVsTc

© 2023 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or

completeness of the information included herein and shall not be liable for any action in reliance thereon. The

information presented in this document is not intended as any commercial offer and does not form part of any

quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered www.lighting.philips.com

trademarks of Koninklijke Philips N.V. 2023, April 15 - data subject to change

You might also like