© ABB Power Technologies AB

-0

PCM 600 Version 1.1


Connectivity Package for an IED or IED family

Data signal description


Parameters description
Protocol addresses
Documentation
IED interface modules, e.g. for
disturbance file handling
IED description according to IEC
61850
© ABB Power Technologies AB
-0
PCM 600 – Connectivity Package Manager

This program can be used for


integrating the Connectivity Packages
with PCM 600
It is launched from a shortcut that is
created in the desktop by installation
© ABB Power Technologies AB

of the PCM 600


-0
© ABB Power Technologies AB
-0
PCM 600 – Supported topologies/protocols

PCM 600 can be connected to IED670 in the following ways:

To single IED via front connector of the IED (IEC 61850)

To multiple IEDs via fixed station bus (IEC 61850, ethernet)


To multiple IEDs by using RAS (Remote Access Service) dial-up. (IEC 61850)
To multiple IEDs by using VPN connection (IEC 61850)
© ABB Power Technologies AB
-0
Tools – PCM 600 in the SA environment
© ABB Power Technologies AB
-0
Communication PC – IED – Front Connection
© ABB Power Technologies AB
-0
Communication PC - IEDs - Ethernet (LAB)
© ABB Power Technologies AB
-0
Communication PC - IEDs - ETHERNET
© ABB Power Technologies AB
-0
Communication setting

Easy set-up of IP address for


each IED from PCM600.
Standard Windows Control Panel
for set-up of PC ethernet card
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

Engineering Flow
Engineering Flow – PCM600/Navigator

Define the project structure


in a very easy and intuitive
way.
© ABB Power Technologies AB
-0
Engineering Flow – PCM600/Navigator
Define the IEDs

In order to define the IEDs you will


use the WIZARD.
It can happen that:

YOU HAVE :
- Order Specific File
- Pre Config File

YOU DO NOT HAVE :


- Order Specific File
© ABB Power Technologies AB

- Pre Config File


-0
Engineering Flow – PCM600/Navigator
Define the IEDs YOU DO NOT HAVE :
- Order Specific File
- Pre Config File

Hardware Configuration can be manually entered in


CAP531 by using “FUNCTION SELECTOR”
Software configuration will be entered in CAP531 by an on-
line process called “UPLOAD OPTIONS”.
(also HW configuration can be entered by an on-line
process)
© ABB Power Technologies AB
-0
Navigator – Adding Object : The Wizard

No order specific file available….


© ABB Power Technologies AB

DO NOT PRESS CANCEL!!


-0
Navigator – Adding Object : The Wizard

No PreConfig file available…..


© ABB Power Technologies AB

THEY DO NOT WORK FOR IED670


VERSION 1.0 !!!!!
-0
Navigator – Adding Object : The Wizard
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

The FIRST Way…..


© ABB Power Technologies AB
-0

Engineering Flow
Application Configuration tool CAP531
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

Insert a work sheet


© ABB Power Technologies AB
-0

Insert function block


© ABB Power Technologies AB
-0

Insert function block


© ABB Power Technologies AB
-0

Connect function blocks


© ABB Power Technologies AB
-0

Variables
Variables: Cross referenced vs not cross referenced
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

Useful graphic buttons


© ABB Power Technologies AB
-0

CAD FEATURES
CAP 531 / Defining Hardware (Function Selector)
© ABB Power Technologies AB
-0
CAP 531 / Compiling the configuration
© ABB Power Technologies AB
-0
CAP 531 / Downloading the configuration
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0
Downloading phase
© ABB Power Technologies AB
-0
Downloading phase
© ABB Power Technologies AB
-0
Downloading phase
CAP 531 / Exit CAP531 and go back to PCM600
© ABB Power Technologies AB
-0
Inputs/Outputs in CAP531 are Hardware Independent
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

Signal Matrix Tool (SMT)


SMT: Virtual and Real Binary Inputs
HARDWARE: Binary Input Card
© ABB Power Technologies AB
-0
SMT: How it works in practice
© ABB Power Technologies AB
-0
SMT: How it works in practice
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

The result of SMT settings:


The result of different SMT settings:
© ABB Power Technologies AB
-0
SMT: Virtual and Real Binary Outputs
© ABB Power Technologies AB
-0
SMT for Binary Outputs
THIS IS WHAT YOU DO IN SIGNAL MATRIX TOOL:
© ABB Power Technologies AB
-0
The result of Output Configuration:
© ABB Power Technologies AB
-0
Configuration of Analog Inputs in CAP531
© ABB Power Technologies AB
-0
Analog Input Configuration with SMT
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

HMI LED Configuration


© ABB Power Technologies AB
-0

HMI LED Configuration


© ABB Power Technologies AB
-0

Parameter Setting Tool


Settings

Settings for different


IEDs
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

Basic or Advanced Settings


Easy and intuitive download/upload
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

The SECOND Way…..


Navigator – Adding Object : The Wizard
© ABB Power Technologies AB
-0
Navigator – Adding Object : The Wizard
© ABB Power Technologies AB
-0
Navigator – Adding Object : The Wizard
© ABB Power Technologies AB
-0
Navigator – Adding Object : The Wizard
© ABB Power Technologies AB
-0
Engineering Flow – PCM600/Navigator
YOU DO HAVE : YOU DO NOT HAVE :
Define the IEDs - Pre Config File
- Order Specific File

Hardware Configuration is automatically entered in CAP531


by the WIZARD
Software library is automatically entered in CAP531 by the
WIZARD
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0

Engineering Flow – Summary


© ABB Power Technologies AB
-0

The 3rd Way (s)…..


PCM600 – Importing a project (decompression)
© ABB Power Technologies AB
-0
PCM600 – Importing a project (decompression)
© ABB Power Technologies AB
-0
PCM600 – Exporting a project (compression)
© ABB Power Technologies AB
-0
PCM600 – Exporting a project (compression)
© ABB Power Technologies AB
-0
PCM600 – Exporting a project (compression)
© ABB Power Technologies AB
-0
© ABB Power Technologies AB
-0
Engineering Flow – Upload all
© ABB Power Technologies AB
-0
Engineering Flow – Upload all
© ABB Power Technologies AB
-0
Engineering Flow – Upload all
© ABB Power Technologies AB
-0
Engineering Flow – Upload CAP531 configuration
© ABB Power Technologies AB
-0
Engineering Flow – Upload CAP531 configuration
© ABB Power Technologies AB
-0
Engineering Flow – Upload CAP531 configuration
© ABB Power Technologies AB
-0
Engineering Flow – Upload SMT information
© ABB Power Technologies AB
-0
Engineering Flow – Upload SMT information
© ABB Power Technologies AB
-0
Engineering Flow – Upload SMT information
© ABB Power Technologies AB
-0
Engineering Flow – Upload PST Settings
© ABB Power Technologies AB
-0
Engineering Flow – Upload PST Settings
© ABB Power Technologies AB
-0
Engineering Flow – Upload PST Settings
© ABB Power Technologies AB
-0
Engineering Flow – Upload PST Settings
© ABB Power Technologies AB
-0
Engineering Flow – Upload PST Settings
© ABB Power Technologies AB

Save and Exit from Parameter Setting.


-0
© ABB Power Technologies AB
-0

Changes/Update