0% found this document useful (0 votes)
31 views6 pages

AC Centrifugal Fan D4E225-CC01-39

Uploaded by

bjhengrui939
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views6 pages

AC Centrifugal Fan D4E225-CC01-39

Uploaded by

bjhengrui939
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

D4E225-CC01-39 AC centrifugal fan

forward curved, dual inlet


with housing (large flange)

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
[email protected]
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


County court Stuttgart · HRB 590142

Nominal data

Type D4E225-CC01-39
Motor M4E074-LA

Phase 1~ 1~
Nominal voltage VAC 230 230
Frequency Hz 50 60

Type of data definition ml ml


Valid for approval / standard CE CE
Speed min-1 1210 1300
Power input W 540 625
Current draw A 2.4 2.75
Motor capacitor µF 16 16
Capacitor voltage VDB 400 400
Capacitor standard P2 (CE) P2 (CE)
Min. back pressure Pa 250 300
Min. ambient temperature °C -25 -25
Max. ambient temperature °C 30 30
ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit
Subject to alterations

Data according to ErP directive


Actual Request 2013 Request 2015

Installation category B Overall efficiency ηe 36.5 33.9 40.9


Efficiency category Total Efficiency grade N 44.6 42 49
Variable speed drive No Power input Pe kW 0.53
Specific ratio* 1.00 Air flow qv m³/h 1965
* Specific ratio = 1 + pf / 100 000 Pa Pressure increase pf Pa 361
Speed n min-1 1335
Data definition with optimum efficiency.

Item no. 11122-5-9980 · Revision 79640 · Release 2013-03-06 · Page 1 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D4E225-CC01-39 AC centrifugal fan
forward curved, dual inlet
with housing (large flange)

Technical features

Mass 13.4 kg
Size 225 mm
Surface of rotor Coated in black
Material of impeller Sheet steel, galvanised
Housing material Sheet steel, galvanised
Material of guard grille Steel, galvanised and plastic-coated in white aluminium (RAL 9006)
Motor suspension Motor anti-vibration mounted on both sides
Direction of rotation Counter-clockwise, seen on rotor
Type of protection IP 22
Insulation class "B"
Humidity class F2-1
Max. permissible ambient motor + 80 °C
temp. (transp./ storage)
Min. permissible ambient motor - 40 °C
temp. (transp./storage)
Mounting position Any
Condensate discharge holes None
Operation mode S1
Motor bearing Ball bearing
Touch current acc. IEC 60990 < 0.75 mA
(measuring network Fig. 4, TN
system)
Motor protection Thermal overload protector (TOP) brought out
Protection class I (if protective earth is connected by customer)
Product conforming to standard EN 60335-1; CE
Approval CSA C22.2 Nr.100; UL 1004-1; CCC

Item no. 11122-5-9980 · Revision 79640 · Release 2013-03-06 · Page 2 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D4E225-CC01-39 AC centrifugal fan
forward curved, dual inlet
with housing (large flange)

Product drawing

1 Connection line with connector housing WAGO 231-608/019-000


1.1 Capacitor
1.2 Z
1.3 U1
1.4 TOP
1.5 PE
1.6 TOP
1.7 Capacitor
1.8 U2

Item no. 11122-5-9980 · Revision 79640 · Release 2013-03-06 · Page 3 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D4E225-CC01-39 AC centrifugal fan
forward curved, dual inlet
with housing (large flange)

Connection screen

TOP 2 x grey U1 blue Z brown


U2 black PE green / yellow

Item no. 11122-5-9980 · Revision 79640 · Release 2013-03-06 · Page 4 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D4E225-CC01-39 AC centrifugal fan
forward curved, dual inlet
with housing (large flange)

Charts: Air flow 50 Hz


Druck p f s[Pa]für Rho=1,2kg/m^3

qv[cfm]
0 200 400 600 800 1.000 1.200 1.400 1.600 1.800 2.000

400 1,6
1,55
380
1,5
4 1,45
360
Measurement: LU-35314
1,4
340
1,35 Air performance measured as per ISO 5801
320
1,3 Installation category A. For detailed
1,25 information on the measuring set-up, please
3 contact ebm-papst. Suction-side noise
300 1,2 levels: LwA measured as per ISO 13347 /
1,15 LpA measured with 1m distance to fan axis.
280 The values given are valid under the
1,1
measuring conditions mentioned above and
260 1,05 may vary according to the actual installation
1 situation. With any deviation from the
240 0,95
standard set-up, the specific values have to
be checked and reviewed with the unit

p fs_E[IN H2O]
0,9 installed.
220
0,85
pf s[Pa]

2
200 0,8
0,75
180
0,7
160 0,65
0,6
140 0,55
0,5
120
0,45
1
100 0,4
0,35
80
0,3

60 0,25
0,2
40
pf s[Pa]

0,15
0,1
20
0,05
0 0
0 500 1.000 1.500 2.000 2.500 3.000 3.500
qv[m^3/h]

Measured values
U f n Pe I qv pfs
V Hz min-1 W A m3/h Pa
1 230 50 1150 783 3.42 2975 100
2 230 50 1195 689 3.05 2700 200
3 230 50 1300 581 2.65 2215 300
4 230 50 1395 445 2.15 1300 360
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase

Item no. 11122-5-9980 · Revision 79640 · Release 2013-03-06 · Page 5 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
D4E225-CC01-39 AC centrifugal fan
forward curved, dual inlet
with housing (large flange)

Charts: Air flow 60 Hz


Druck p f s[Pa]für Rho=1,2kg/m^3

qv[cfm]
0 200 400 600 800 1.000 1.200 1.400
560
2,2
540
520 2,1

500 4 2
480 Measurement: LU-35316
1,9
460 3 Air performance measured as per ISO 5801
1,8
440 Installation category A. For detailed
information on the measuring set-up, please
420 1,7
contact ebm-papst. Suction-side noise
2 levels: LwA measured as per ISO 13347 /
400 1,6
LpA measured with 1m distance to fan axis.
380
1,5
The values given are valid under the
measuring conditions mentioned above and
360
1,4
may vary according to the actual installation
340 situation. With any deviation from the
1,3
standard set-up, the specific values have to
320 be checked and reviewed with the unit
1

p fs_E[IN H2O]
300 1,2 installed.
pf s[Pa]

280
1,1
260
1
240
220 0,9

200 0,8
180
0,7
160
0,6
140
120 0,5

100 0,4
80 0,3
60
pf s[Pa]

0,2
40
20 0,1

0 0
0 200 400 600 800 1.000 1.200 1.400 1.600 1.800 2.000 2.200 2.400 2.600
qv[m^3/h]

Measured values
U f n Pe I qv pfs
V Hz min-1 W A m3/h Pa
1 230 60 1300 646 2.81 1995 300
2 230 60 1465 553 2.43 1700 400
3 230 60 1565 474 2.13 1340 450
4 230 60 1645 390 1.83 800 490
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase

Item no. 11122-5-9980 · Revision 79640 · Release 2013-03-06 · Page 6 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com