IEC 61850 Certificate Level A1

No. 84000167-OPE/INC 17-2549

Issued to: For the server product:


Efacec Energia, Máquinas e Equipamentos TPU S430 Multifunction protection and control relay
Eléctricos, S.A. Software version: 2.04.000
Rua Eng. Frederico Ulrich · Guardeiras Hardware version (CPU board): MAP8100
Apartado 3078 ASID10000140 Rev. 2.5
4471-907 Moreira da Maia S/N: 937488
Portugal

The server product has not been shown to be non-conforming to:

IEC 61850 Edition 2 Parts 6, 7-1, 7-2, 7-3, 7-4 and 8-1
Communication networks and systems for power utility automation
The conformance test has been performed according to IEC 61850-10 Edition 2, the UCA International Users
Group Edition 2 Server Test Procedures version 1.0 with TPCL2 1.2 with product’s protocol, model and technical
issue implementation conformance statements: “Protocol Implementation Conformance Statement (PICS) for
the IEC 61850 Interface for TPU S430, TPU S22 and TPU M220, AS17027167, Rev. 00, May-2017”, “Model
Implementation Conformance Statement (MICS) for the IEC 61850 Interface for TPU S430, TPU S22 and TPU
M220, AS17027277, Rev. 00, May-2017” and “TISSUES Implementation Conformance Statement (TICS) for the
IEC 61850 Interface for TPU S430, TPU S22 and TPU M220, AS17027278, Rev. 00, May-2017” and the extra
information for testing: “Protocol Implementation Extra Information for Testing (PIXIT) for the IEC 61850
Interface for TPU S430, TPU S22 and TPU M220, AS17027256, Rev. 00, May-2017”.

The following IEC 61850 conformance blocks have been tested with a positive result (number of relevant and
executed test cases / total number of test cases):

1 Basic Exchange (22/26) 9b GOOSE Subscribe (13/14)


2 Data Sets (4/7) 12a Direct Control (8/18)
3 Substitution (3/3) 12b SBO Control (15/27)
4 Setting Group Selection (4/4) 12c Enhanced Direct Control (9/20)
4+ Setting Group Definition (12/13) 12d Enhanced SBO Control (17/28)
5 Unbuffered Reporting (18/21) 13 Time Synchronization (5/7)
6 Buffered Reporting (25/30) 14 File Transfer (5/8)
9a GOOSE Publish (11/13)

This certificate includes a summary of the test results as carried out at Efacec in Portugal with UniGrid SA
v1.2.305 with test suite Ed2 v1.2 and UniCA 61850 Analyzer 5.31.00. This document has been issued for
information purposes only, and the original paper copy of the DNV GL verification report No. 84000167-OPE/INC
17-2550 will prevail.

The test has been carried out on one single specimen of the product as referred above and submitted to DNV GL
by Efacec. The manufacturer’s production process has not been assessed. This certificate does not imply that
DNV GL has approved any product other than the specimen tested.

Arnhem, August 18, 2017

Issued by:

P. Cioci R. Schimmel
Business Director Verification Manager
Intelligent Networks and Communication

1
Level A - Independent test lab with certified ISO 9001 Quality System
2
TPCL - Test procedures change list

Copyright © DNV GL Netherlands B.V. Arnhem, the Netherlands. All rights reserved. It is prohibited to update or
change this certificate in any manner whatsoever, including but not limited to dividing it into parts.

DNV GL Netherlands B.V. Utrechtseweg 310, 6812 AR Arnhem, P.O. Box 9035, 6800 ET Arnhem, the Netherlands
T +31 26 356 9111 F +31 26 351 36 83 [email protected] www.dnvgl.com Page 1/2
IEC 61850 Certificate Level A No. 84000167-OPE/INC 17-2549

Applicable Test Procedures from the UCA International Users Group Edition 2 Server Test Procedures
version 1.0 with TPCL 1.2

Conformance Block Mandatory Conditional

1: Basic Exchange sAss1, sAss2, sAss3, sAssN2, sAssN3, sSrv6, sSrv8, sSrv11, sSrv12, sSrvN1e,
sAssN4, sAssN5, sSrv1, sSrv2, sSrv3, sSrvN1f, sSrvN2, sSrvN3
sSrv4, sSrv5, sSrvN1abcd, sSrvN4
2: Data Sets sDs1, sDs10a, sDsN1ae sDs15
3: Substitution sSub1, sSub2, sSub3
4: Setting Group sSg1, sSg3, sSgN1 sSg11
Selection
4+: Setting Group sSg2, sSg4, sSg7, sSg8, sSg10, sSg12, sSg6, sSg9
Definition sSgN2, sSgN3, sSgN4, sSgN5
5: Unbuffered sRp1, sRp2, sRp3, sRp4, sRp5, sRp9, sRp8, sRp10, sRp11, sRp12, sRpN5
Reporting sRp14, sRp15, sRpN1, sRpN2, sRpN3,
sRpN4, sRpN8
6: Buffered Reporting sBr1, sBr2, sBr3, sBr4, sBr5, sBr9, sBr8, sBr10, sBr11, sBr12
sBr14, sBr15, sBr20, sBr21, sBr22,
sBr25, sBr26, sBr27, sBr28, sBrN1,
sBrN2, sBrN3, sBrN4, sBrN5, sBrN8
9a: GOOSE publish sGop2a, sGop3, sGop4, sGop9, sGop10, sGop1, sGop6, sGop7, sGopN1, sGopN2
sGop11
9b: GOOSE subscribe sGos1, sGos2, sGos3, sGos5, sGos6a, sGos4
sGos7, sGosN1, sGosN2, sGosN3,
sGosN4, sGosN5, sGosN6
12a: Direct control sCtl5, sCtl10, sDOns1, sDOns2 sCtl15, sCtl16, sCtl17, sCtl19
12b: SBO control sCtl5, sCtl8, sCtl9, sCtl10, sCtl11, sCtl4, sCtl6, sCtl15, sCtl16, sCtl17, sCtl19
sCtl25, sSBOns1, sSBOns2, sSBOns6
12c: Enhanced Direct sCtl5, sCtl10, sDOes1, sDOes2 sCtl14, sCtl15, sCtl16, sCtl17, sCtl19
Control
12d: Enhanced SBO sCtl5, sCtl8, sCtl9, sCtl10, sCtl11, sCtl4, sCtl6, sCtl15, sCtl16, sCtl17, sCtl19,
Control sCtl25, sSBOes1, sSBOes2, sSBOes6, sCtl26
sSBOes8
13: Time sync sTm1, sTm2, sTmN1 sTm3, sTmN2
14: File transfer sFt1, sFt2ab, sFt4, sFt5, sFtN1ab

All configuration file and data model tests have been successfully performed for the product variants using
the same communication hardware and software version:
• TPU S220 Compact protection and control relay
• TPU M220 Compact protection and control relay

DNV GL Netherlands B.V. Utrechtseweg 310, 6812 AR Arnhem, P.O. Box 9035, 6800 ET Arnhem, the Netherlands